
Pos: 24 /Busch-Jaeger ( Neustruktur)/Modul-Struktur /Online-Dokumentation/ Überschriften (--> Für alle Dokume nte <--)/1. Ebene/M - O/Montag e / Installation @ 18\mod_13026139 66111_15.docx @ 103373 @ 1 @ 1
7 Mounting / Installation
Pos: 25 /Busch-Jaeger ( Neustruktur)/Modul-Struktur /Online-Dokumentation/Sic herheit (--> Für alle Dokument e <--)/Warnhinweise/Sic herheit - Niederspannun gs-und 230 V-Lei tungen @ 18\mod_130261782149 1_15.docx @ 103465 @ @ 1
Risk of death and fire due to electrical voltage of 230 V.
– Low-voltage and 230 V cables must not be installed together in a flush-mounted socket!
In case of a short-circuit there is the danger of a 230 V load on the low-voltage line.
Pos: 26 /Busch-Jaeger ( Neustruktur)/Modul-Struktur /Online-Dokumentation/Sic herheit (--> Für alle Dokument e <--)/Warnhinweise/Sic herheit - Fachkenntnisse @ 18\m od_1302774384017_15.d ocx @ 103564 @ 2 @ 1
7.1 Requirements for the electrician
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
• Incorrect installation endangers your life and that of the user of the electrical system.
• Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
• Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth;
5. Cover or barricade adjacent live parts.
• Use suitable personal protective clothing.
• Use only suitable tools and measuring devices.
• Check the type supply network (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos: 27 /DinA4 - Anleitungen Onli ne/Inhalt/KNX/DoorEn try/Montage/Montagehin weise - Allgemein @ 19\mod_131056 3670478_15.docx @ 107743 @ 2 @ 1
7.2 General installation instructions
• Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station,
system device).
• Do not install the system controller directly next to the bell transformer and other power supplies (to avoid
interference).
• Do not install the wires of the system bus together with 230 V wires.
• Do not use common cables for the connecting wires of the door openers and wires of the system bus.
• Avoid bridges between different cable types.
• Use only two wires for the system bus in a four-core or multi-core cable.
• When looping, never install the incoming and outgoing bus inside the same cable.
• Never install the internal and external bus inside the same cable.
Pos: 28 /Busch-Jaeger ( Neustruktur)/Modul-Struktur /Online-Dokumentation/Steuer module - Onli ne-Dokumentation (--> Für alle Dokument e <--)/++++++++++++Seitenumbruch++++++++++++@ 9\mod_1268898668093_ 0.docx @ 521 49 @ @ 1