MONTAGE- und BETRIEBSANLEITUNG
FEUCHTE / TEMPERATUR MESSUMFORMER
Type: SERIE EE06
INSTRUCTIONS for SETTING UP and OPERATING
HUMIDITY / TEMPERATURE TRANSMITTER
Type: SERIES EE06
Langwiesen 7
A-4209 Engerwitzdorf
Austria
T: +43-7235-605-0 F: +43-7235-605-8
E: [email protected] I: http://www.epluse.at
TECHNISCHE DATEN
Ausgang entsprechend
0...100%r.F. und -40...60°C 0-1 V
Betriebsspannung SELV 4,5...30 VDC
Stromverbrauch typ. 1,5 mA (max. 2,5 mA) ohne Ausgangsbelastung
Ausgangsbelastung max. 0,2 mA
Temperaturbereich
Betrieb (Elektronik)
Lagerung -40...60°C
-40...65°C
Gehäuse Polycarbonat / IP65 (Modell A) in senkrechter Montage
TECHNICAL DATA
output appropriate
0...100% RH and -40...60°C (-40...140°F) 0-1 V
supply voltage SELV 4.5...30 VDC SELV = Safety Extra Low Voltage
supply current typ. 1.5 mA (max. 2.5 mA) without output load
output load max. 0.2 mA
temperature range
operating (electronics)
storage -40...60 degC (-40...140°F)
-40...65 degC (-40...149°F)
housing Polycarbonat / IP65 (Model A) in vertical mounting
ALLGEMEIN:
Messumformer der Serie EE06 sind für die Erfassung von Feuchte und Temperatur bestimmt.
Ein kapazitiver Sensor wird als Messelement für die Feuchtemessung verwendet.
Anwendung findet die Serie EE06 in Be- und Entfeuchtungsanlagen, bei der Klimatisierung von
Museen, bei der Überwachung von Lagerräumen oder feuchteempfindlichen Geräten, wie z.B.
Fotokopiermaschinen.
Bei Sonderanwendungen wenden Sie sich bitte an den Hersteller oder an Ihren zuständigen
Händler.
ACHTUNG:
Extreme mechanische und unspezifizierte Beanspruchungen sind unbedingt zu vermeiden.
Bei den Typen ohne Gehäuse (EE06-xBx) handelt es sich um ein ESD gefährdetes Teil, d.h.
Berührungen während des Betriebes sind zu vermeiden.
Bei Wartungsarbeiten sind ESD Schutzmaßnahmen erforderlich.
Fehler mögliche Ursache Maßnahme
unrealistische Werte nicht optimale Montage Achten Sie darauf, dass der Fühlerkopf die gleiche
Temperaturwie die zu messende Luft besitzt. Bei
Freilandanwendung - Strahlungsschutz verwenden!
Für die Überprüfung der Ausgangswerte stehen
Test Kits zur Verfügung.
zu lange Ansprechzeit Verschmutzung des Filters
Falsche Filtertype Filtertausch
Filtertype ist auf die Anwendung anzupassen
Ausfall des Gerätes keine Versorgungsspannung Zuleitung und Versorgungsspannung überprüfen
zu hohe Feuchtewerte Betauung im Fühlerkopf Fühlerkopf trocknen; evtl. Filterkappe wechseln.
GENERAL:
The EE06 transmitters are designed to measure humidity and temperature.
They use a capacitive sensor element for the humidity measurement.
Common applications for the series EE06 are in the field of humidifiers and dehumidifiers, climate
controls in museums, monitoring of storage rooms as well as control units such as photostatic
machines.
For special applications do not hesitate to contact the manufacturer or the corresponding distributor.
ATTENTION:
Absolutely avoid extreme mechanical and unspecified strain.
Models without housing (EE06-xBx) are ESD sensitive devices. Please avoid touching the device
during operation.
For maintenance purposes it is recommended, that you observe the valid ESD-safety precautions!
Selbsthilfe bei Fehlern: Self-help in case of errors:
BA_EE06_10 // Technische Änderungen vorbehalten // 302244 BA_EE06_10 // technical data are subject to change
error possible cause remedies
unrealistic values wrong installation Please take care that the ambient temperature of
the transmitter is the same like the measuring
temperature. For outdoor applications use a radi-
ation shield. For rechecking the humidity calibra-
tion we suggest to use our Humidity Test-Kits
long response time pollution of the filter
wrong filter type change filter cap
adjust filter type to application
complete failure of the instrument no supply voltage check supply cable and supply voltage
humidity values too high bedewing of the sensor probe dry the sensor probe and if necessary replace the filter
Feuchte-/Temperatur Messumformer Serie EE06
Humidity-/Temperature Transmitter Series EE06
Abmessungen / Dimensions:
Anschlussbild / Connection Digram:
Ø12
34 82
Ø12
34 60
Ø12
34 80 7
M10x1
Kabellänge Standard = 500mm
cable length standard = 500mm (19.7”) Kabellänge Standard = 500mm
cable length standard = 500mm (19.7”)
Kabellänge Standard = 200mm
cable length standard = 200mm (7.9”)
+
-
V
V
Versorgungsspannung/
power supply
4,5...30 VDC
+V (weiß / white)
GND (braun / brown)
RH (grün / green)
T (gelb / yellow)
Bei Kabellänge > 500mm ist die Anbindung des
Kabelschirms zur Gewährleistung der EMV Kompatibilität
zwingend notwendig!
If the cable length is > 500mm (19.7”) connect the cable
screening to fulfil he EMC requirements!
Typ A Typ B Typ C
1 mm = 0.03937” / 1” = 25.4 mm
USA
FCC notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interferen-
ce in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the installation manual, may cause harmful interference to radio com-
munications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this device.
CANADIAN
ICES-003 notification:
This Device B digital apparatus complies with Canadian ICES-003. / Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Other E+E Elektronik Transmitter manuals

E+E Elektronik EE29 Series User manual

E+E Elektronik

E+E Elektronik EE29 Series User manual

E+E Elektronik EE061 Series Instruction manual

E+E Elektronik

E+E Elektronik EE061 Series Instruction manual

E+E Elektronik EE650 User manual

E+E Elektronik

E+E Elektronik EE650 User manual

E+E Elektronik EE99-1 Series User manual

E+E Elektronik

E+E Elektronik EE99-1 Series User manual

E+E Elektronik EE150 User manual

E+E Elektronik

E+E Elektronik EE150 User manual

E+E Elektronik EE650 User manual

E+E Elektronik

E+E Elektronik EE650 User manual

E+E Elektronik EE040 User manual

E+E Elektronik

E+E Elektronik EE040 User manual

E+E Elektronik EE210 User manual

E+E Elektronik

E+E Elektronik EE210 User manual

E+E Elektronik EE355 User manual

E+E Elektronik

E+E Elektronik EE355 User manual

E+E Elektronik EE22 Series User manual

E+E Elektronik

E+E Elektronik EE22 Series User manual

E+E Elektronik EE310 User manual

E+E Elektronik

E+E Elektronik EE310 User manual

E+E Elektronik EE300E Series User manual

E+E Elektronik

E+E Elektronik EE300E Series User manual

E+E Elektronik EE210 User manual

E+E Elektronik

E+E Elektronik EE210 User manual

E+E Elektronik EE04 Series User instructions

E+E Elektronik

E+E Elektronik EE04 Series User instructions

E+E Elektronik EE360 User manual

E+E Elektronik

E+E Elektronik EE360 User manual

E+E Elektronik EE870 User manual

E+E Elektronik

E+E Elektronik EE870 User manual

E+E Elektronik EE31 User manual

E+E Elektronik

E+E Elektronik EE31 User manual

E+E Elektronik EE310 User manual

E+E Elektronik

E+E Elektronik EE310 User manual

E+E Elektronik EE36 Series User manual

E+E Elektronik

E+E Elektronik EE36 Series User manual

E+E Elektronik EE23 series User manual

E+E Elektronik

E+E Elektronik EE23 series User manual

E+E Elektronik EE820 User manual

E+E Elektronik

E+E Elektronik EE820 User manual

E+E Elektronik EE650 User manual

E+E Elektronik

E+E Elektronik EE650 User manual

E+E Elektronik EE65 Series User instructions

E+E Elektronik

E+E Elektronik EE65 Series User instructions

E+E Elektronik EE375 Series User manual

E+E Elektronik

E+E Elektronik EE375 Series User manual

Popular Transmitter manuals by other brands

Vega VEGABAR 86 Quick setup guide

Vega

Vega VEGABAR 86 Quick setup guide

PRAXSYM PST user manual

PRAXSYM

PRAXSYM PST user manual

K-Mate AT1900-1A-MFI user manual

K-Mate

K-Mate AT1900-1A-MFI user manual

Community Controls Monarch 295SEPA2KC manual

Community Controls

Community Controls Monarch 295SEPA2KC manual

CrimeStopper SecurView SV-8100.W installation instructions

CrimeStopper

CrimeStopper SecurView SV-8100.W installation instructions

Questtel L-1SDI-NFE-TX user manual

Questtel

Questtel L-1SDI-NFE-TX user manual

Simplex 4100 Series installation instructions

Simplex

Simplex 4100 Series installation instructions

Azden IRN-20 manual

Azden

Azden IRN-20 manual

Ramsey Electronics FM35 instruction manual

Ramsey Electronics

Ramsey Electronics FM35 instruction manual

PCB Piezotronics IMI SENSORS 682C13 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 682C13 Installation and operating manual

Nautel NX50 troubleshooting manual

Nautel

Nautel NX50 troubleshooting manual

Masibus HT7S Series manual

Masibus

Masibus HT7S Series manual

JUMO dTRANS T05 operating manual

JUMO

JUMO dTRANS T05 operating manual

Becker CentronicPLUS EC548A PLUS Assembly and operating instructions

Becker

Becker CentronicPLUS EC548A PLUS Assembly and operating instructions

Marathon OXYMITH TRANSMITTER F200060 Operator's manual

Marathon

Marathon OXYMITH TRANSMITTER F200060 Operator's manual

catec 7.1414.60.000 Instructions for use

catec

catec 7.1414.60.000 Instructions for use

Bellman & Symfon Bellman Visit BE1023 user manual

Bellman & Symfon

Bellman & Symfon Bellman Visit BE1023 user manual

Nyrius NPCS549 user guide

Nyrius

Nyrius NPCS549 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.