eqss OverWatch 6253 User manual

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
EQSS Model6253 –OverWatch™
Dingli MVxxx RS Series
I
N
S
T
A
L
L
M
A
N
U
A
L
** Failure to follow this installation manual will void warranty **

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|2 of 23|
AUTHORS:
Kieren Grogan, Bhavani Kacharapu
AUTHORISED BY:
Kieren Grogan
CHECKED BY:
Kieren Grogan
DOCUMENT ABSTRACT:
This Installation Manual details the manufacturer’s installation instructions for installing the Model6253 OverWatch on a Dingli
MVxxxRS Series Vertical Mast Lift.
PRODUCT NAME:
Model6253 OverWatch Operator Detection System
REFERENCE DOCUMENTS:
DO0001195 Model6253 OverWatch User Manual
CURRENT DOCUMENT REVISION:
1.1
REVISION INFORMATION:
•1.0 Initial Document Creation for installation on a Dingli MVxxxRS series
•1.1 Update of model configuration instructions

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|3 of 23|
Important Information
Information contained in this publication regarding this device’s applications and the like, is provided only for your
convenience and may be superseded by updates. It is your responsibility to ensure that the application or our
equipment meets with your specifications.
EQUIPMENT SAFETY SYSTEMS MAKE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, WHETHER EXPRESSED OR
IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING, BUT NOT
LIMITED TO, IT’S CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR PURPOSE.
Equipment Safety Systems disclaims all liability arising from this information and its use. Use of Equipment Safety
Systems’ products as critical components in life support systems is not authorised except with express written
approval by Equipment Safety Systems. No licenses are conveyed, implicitly or otherwise, under any Equipment Safety
Systems intellectual property rights.
This is a class A product certified to AS/NZS CISPR 22:2006. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|4 of 23|
Table of Contents
Preparation.........................................................................................................................................................................5
Required Tools ...............................................................................................................................................................5
Installation Time ............................................................................................................................................................ 5
Installation Instructions......................................................................................................................................................6
Operator Sensor............................................................................................................................................................. 6
Control Module..............................................................................................................................................................9
Post Installation Configuration .........................................................................................................................................16
Overview...................................................................................................................................................................... 16
Minimum system requirements .................................................................................................................................. 16
Wi-Fi Connection & Web Page Access .........................................................................................................................16
Machine Model Selection ............................................................................................................................................17
Installation Test............................................................................................................................................................ 18
Change Model Configuration.......................................................................................................................................19
System Settings.................................................................................................................................................................20
Default Parameters...................................................................................................................................................... 20
Polarity and Input Style................................................................................................................................................ 21
Harness Drawing AS002248..............................................................................................................................................22
Replacement Parts............................................................................................................................................................ 23

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|5 of 23|
Preparation
Required Tools
The OverWatch has been designed to be fitted using basic workshop tools. Shown below is a list of tools required
to complete the installation.
Item
Tool / Description
1
Electric Drill
2
Centre punch
3
Hammer
4
Side Cutters
5
Drill 3.2mm
6
Drill 5.0mm
7
Drill 6.0mm
8
Step Drill (5 –30mm)
9
Metric sockets or spanners
10
Needle nose pliers
11
Screw drivers
Installation Time
The suggested time required to install the OverWatch is as detailed below.
Task
Estimated Time (Minutes)
Open the operator control box
1
Drilling of all mounting holes for the various components
13
Mechanical assembly
10
Electrical assembly
30
Post installation system tests
10
Close the operator control box
1
Total
65

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|6 of 23|
Installation Instructions
Operator Sensor
Step
Description
Diagram
1.
Remove the joystick
controller from its housing.
2.
Drill two 6mm holes to mount
the operator sensor in the
position as shown in the
image.
The sensor should be
mounted at an angle of 45
degrees from the vertical of
the mounted enclosure.
Distance is measured from
the vertical and horizontal
edge of the metal cover.
Hole #1- 18mm from the top
horizontal edge and 38mm
from the vertical edge.
Hole #2- 61mm from the top
horizontal edge and 76mm
from the vertical edge.
The distance between the
two holes is 61mm.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|7 of 23|
3.
Drill two 5mm holes to mount
P-Clips on the metal
enclosure as shown in the
image.
4.
Mount the operator sensor
assembly to the metal
enclosure, using M5 washers
and nuts.
Use the following hardware
from the kit.
1 x AS001910 Operator
Sensor
1 x AS002326 Sensor Guard
Assembly
2 x FA001174 M5 washer
2 x FA001219 M5 Nylock Nut

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|8 of 23|
5.
Make sure that the sensor is
on the 7.5-degree angle, such
that it is twisted outwards
from the joystick controller.
The 7.5-degree twist is
achieved by rotating the
sensor inside the assembly
and using the bolt hole as
show in the image.
6.
Route the sensor cable as
shown in the image. Use the
P-Clips to secure it in place.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|9 of 23|
Control Module
Step
Description
Diagram
1. 1
.
Remove the bottom
plastic cover from the
Joystick to expose the
inside wiring and
electronics.
Remove the buzzer and all
connectors to allow access
to the control box circuit
board.
2.
Drill a 20mm hole to run
the operator sensor M20
gland into the plastic
joystick enclosure. The
position of the hole is
detailed as in the image. It
is recommended to use a
step drill for this hole, as it
is running through plastic
material.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|10 of 23|
3. 2
.
Use a fine metal pick to
clean the area shown in
the red circles, on the
adjacent image, to allow
access to the pins. This
process removes the
conformal coating on the
PCB and allows electrical
access to the drive,
elevate and horn
connections on the circuit
joystick board.
4. 3
.
Behind the Drive select
push button, clean, and
expose the highlighted
pins with a pick.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|11 of 23|
5. 4
.
Behind the Elevate select
push button, clean, and
expose the highlighted
pins with a pick.
6. 5
.
Behind the Horn push
button, clean, and expose
the highlighted pins with a
pick.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|12 of 23|
7. 6
.
Use a fine pair of side
cutters to trim down the
signal pins. These
connections must be
trimmed to be as flat as
possible so that the spring
pin from the plug and play
board can make suitable
contact with the terminal.
8. 7
.
Wiring connections are
made by the AS002248
harness.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|13 of 23|
9. 8
.
Mount the daughter
board on top of joystick
circuit board by using the
provided screws and
spacers in the kit. Make
sure that the board is
sitting in the correct
position and the spring
pins are contacting the
joystick circuit board
signal pins.
10.
Joystick connection:
Install the connectors in
between the joystick and
the control box circuit
board.
Visually check that all pins
from original joystick
connector have a
corresponding cable on
the Overwatch harness.
Reconnect the other
connectors, which were
disconnected in step 1 to
the control box circuit
board.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|14 of 23|
11. 1
0
.
Power Connection:
At the back of the E-stop,
install the OverWatch red
power cable to the
terminal 1 of the E-Stop.
Note: This cable might
need to be changed to
terminal 2 if the
Overwatch is powered
with the E-stop pushed in.
12. 1
1
.
Mount the OverWatch
ECU inside the joystick
control box, by using the
adhesive Velcro tape.
Run the operator sensor
cable through the
predrilled 20mm hole and
secure the cable gland.
Connect the 8-pin
connector from the
operator sensor and the
12-pin connector from the
overwatch loom to the
ECU.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|15 of 23|
13.
Re-assemble the joystick
control box and mount to
the metal shroud.
Make sure the operator
sensor cable runs clear to
the joystick enclosure and
tighten the M20 gland to
seal the cable entry point.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|16 of 23|
Post Installation Configuration
Overview
After the system has been installed it must be configured with the parameters to suit the machine. Follow the
instructions below to configure the OverWatch.
Minimum system requirements
Any smart phone, tablet or laptop that meets the following requirements:
•The device can connect to a Wi-Fi access point
•The device has an up to date web browser installed. Firefox, Chrome or Safari are recommended.
Wi-Fi Connection & Web Page Access
To enable the Wi-Fi connection on the OverWatch to complete the configuration follow the steps below.
1. Power down the platform control box with the ESTOP
2. Wait 5 seconds
3. Power up the platform control box with the ESTOP
4. While standing in front of the operator sensor, switch on the OverWatch
5. As the welcome chime starts to play, cover the sensor. The LED will flash white then black to acknowledge.
6. Remove your hand from the sensor. The LED will flash white then black to acknowledge.
7. After covering then uncovering the sensor this way 2 more times, "Wi-Fi On" will be announced
8. On your Wi-Fi enabled device (laptop, tablet, smartphone, etc), show the available wireless networks
9. Select the wireless network (starts with “overwatch”) to connect to the OverWatch
10. When prompted, enter the password 12345678
11. Open your preferred web browser (Chrome, Firefox, Safari)
Enter the following into the address bar http://192.168.4.1 to open the OverWatch main page

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|17 of 23|
Machine Model Selection
Follow the instructions below to configure the OverWatch.
1. Select the Setup option
2. If there is a password field at the bottom of the page, follow the instructions in Change Model Configuration
to obtain the password and enter the password field
3. Select the EWP Model from the drop-down list and click Set
4. Click on Proceed to test to begin the installation test

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|18 of 23|
Installation Test
After the model configuration has been set or updated an Installation Test must be performed. This will ensure the
installation has been correctly performed and the OverWatch is functioning correctly. Follow the instructions on
the web page to complete the Installation Test.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|19 of 23|
Change Model Configuration
To reconfigure the OverWatch for a different model requires an authorisation password. The authorisation
password is generated from the EQSS website. The EQSS website requires a login username and password, contact
EQSS for these details.
Follow the instructions below to obtain an authorisation password. It is important to note that each ECU has a
unique serial number and a unique password.
1. Open your web browser and enter the following into the address bar http://www.eqss.com.au/overwatch to
open the Login page
2. Enter your username and password
3. Enter the EUC serial number which is shown on the setup page or on the ECU serial number sticker, also
enter the owner and model details of the EWP and then click Generate Hash
4. The generated Hash code or password can be used to change the model configuration.

EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Dingli MVxxxRS Series
Installation Manual
REV 1.1
04/12/2023
Model6253 OverWatch™Installation Manual
Document # DO001638
|20 of 23|
System Settings
Default Parameters
The OverWatch is configured with the following default parameters.
Setting Name
Description
Default
max_safe_velocity
This is the velocity threshold for the cutout in cm/s for drive
mode.
97
max_safe_displacement
This is the maximum permitted distance in cm the operator
may be away from the calibration position in drive mode.
50
max_safe_velocity_elevate
This is the velocity threshold for the cutout in cm/s for
elevate mode.
75
max_safe_displacement_elevate
This is the maximum permitted distance in cm the operator
may be away from the calibration position in elevate mode.
50
fwddispadj
The proportion of the calibration distance toward the
sensor permitted to the operator.
0.55
fwdveloadj
The coefficient to apply to the maximum allowable velocity
when the movement of the operator is toward the sensor.
1.0
zone_obstruction
If the lidar sensor reading is below this, the lidar is
considered to be obstructed (with paint or thick coat of
dust) and the system is cutout until the obstruction is
cleared.
5
zone_minimum
The minimum calibration distance. If the operator is closer
to the sensor than this “operator zone” will be announced.
11
zone_maximum
The maximum calibration distance. If the operator is further
from the sensor than this “operator zone” will be
announced.
120
adc_elevate_threshold
Threshold value for the elevate ADC input.
500
adc_drive_threshold
Threshold value for the drive ADC input.
500
adc_trigger_threshold
Threshold value for the trigger ADC input.
100
adc_joystick_fwd_threshold
Forward threshold value for the joystick ADC input.
900
adc_joystick_bwd_threshold
Backward threshold value for the joystick ADC input.
1100
throttle_time
Period after the trigger is pressed (ms) during which initial
velocity reading is computed.
500
driving_state_timeout
Mode selection switch timeout (ms)
7000
Other manuals for OverWatch 6253
11
Table of contents
Other eqss Safety Equipment manuals
Popular Safety Equipment manuals by other brands

Innova
Innova STONE C1 Installer manual

Halkey-Roberts
Halkey-Roberts Pro1F Inflator User Information Booklet

Petzl
Petzl MACCHU quick start guide

Innotech
Innotech LIGHT-FLEX manual

Tractel
Tractel HT Installation, operating and maintenance manual

Eaton
Eaton CEAG 22011 LED CG-S Series Mounting and operating instructions