ERONE GARAGE DOOR RECEIVER
3 - WIRINGS & POWER SELECTION
4 - OPERATING MODES
The operating mode can be Pulse or timed. In Timed mode the
relay release after a programmable time. The min relay activation
time is 1 Sec. During the delay time a pulse of the transmitter
makes the relay to release.
5 - RELAY RELEASE SETTING
Procedure
1) Press and hold the push-button P1 for 4 sec. until the green
led LD makes a flash ( Fig. 3);
At this point it is possible to set the release time: push P1 as
many times as much is the release time, in seconds, desired.
( max 30 Sec.)
Antenna
Receiver type Superheterodyne
Carrier Frequency 433.92 MHz
Local oscillation frequency 6.6128 MHz
Demodulation AM/ASK
Local oscillator type VCO / PLL
Channel width > 25 KHz
Intermediate frequency 10.7 MHz
Input sensitivity -105 dBm
Spurious emissions < -57 dBm
Input load 50 Ohm
Operating voltage 12/24 Vac/dc
Max power on relay contacts 24 VA
Relay number 1
Operating modes Momentary / Delayed
Min relay pulse 1 Sec
Memory 85 TX keys
Security protocol Keeloq Hopping code
64
Code combinations 2
Operating temperature -20°/+70°C
Enclosure IP grade IP2X
Dimensions ( main box) 40 x 22 x 56 mm
2 - TECHNICAL SPECIFICATIONS
1 - INTRODUCTION
The Erone Garage Door Receiver SEL2641R433-GDR is single
conversion superheterodyne receiver operating at 433,92 MHz in
AM/ASK modulation.
It is designed for automatic closing systems and anti-burglar
systems. The antenna is direct connected with 6,5” wire. The relay
K1 available output is only with NO type contact. The operating
mode of K1 is Pulse and or Timed ( see below for its configuration).
The power supply is 12/24Vac/dc with selection jumper. The IP
grade of 2X allows only indoor installations. Hereby, CDVI
Wireless Spa, declares that the radio equipment type
is in compliance with directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address: www.erone.com.
SEL2641R433-GDR
Use and installation manual
Thank you for choosing this product .
You are recommended to read this manual carefully before
installing this product.
Made in
Italy
0 V
NO
C
+12/24 Vac/dc
JP1
JP1 = CLOSED
12 Vac/dc
JP1=OPEN
24 Vac/dc
REMARK : The supply must be provided from a certified power
supply according to Safety Regulations and coming from a SELV
circuit protected against short-circuit.
LD
4s
P1
2 Sec.
Fig. 3
P1
P1
3 Sec.
P1
30 Sec.
1 Sec.