Introduction
F-Drive series drivers offer centralized control of ArcSystem Navis luminaires, ArcSystem Pro
luminaires, and third-party fixtures. Output wiring requirements and methods vary depending on the
load and the chosen wire type. This guide covers considerations and recommendations for output
wiring from F-Drive series drivers to different types of load. For full installation instructions, see the
F-Drive Series R12 Installation Manual
or
F-Drive Series W1 Installation Manual
and the installation
manual for the luminaire or load (see
Load Types below
). All ETCdocuments are available for free
download at etcconnect.com.
Load Types
F-Drive R12 has modular output cards that can drive a variety of loads, and F-Drive W1Drivers come
in different models to drive a variety of loads. This document covers the following load types. The
associated installation documents for ETCluminaires are listed below for convenience.
•
ArcSystem Navis on the next page
-
ArcSystem Navis installation guides for luminaires and accessories, see
etcconnect.com/Products/Lighting-Fixtures/ArcSystem-Navis/Documentation.aspx
•
ArcSystem Pro Series on page4
-
ArcSystem Pro D1 and D2 Series Drivers Installation Guide
, see
etcconnect.com/Products/Lighting-Fixtures/Pro-One-Cell/Documentation.aspx
•
Third-Party Loads on page6
•
ArcSystem ArcLamp on page7
-
ArcLamp System Installation Manual
, see etcconnect.com/Products/Lighting-
Fixtures/ArcLamp/Documentation.aspx

ETC Reference Guide
F-Drive Series Wiring
F-Drive Series Wiring Page 2 of 7 ETC
ArcSystem Navis
ArcSystem Navis 100 luminaires can be daisy-chained together using their RJ45 In and Out ports.
See the
Arcsystem Navis 100 Installation Guide
for details. This allows F-Drive series drivers to
provide power and data to up to four ArcSystem Navis 100 luminaires from the RJ45 output on a
single output card using Category-type*cable (*see the note below about minimum conductor
gauge).
1 2 3 4
DMX
IN
DMX
THRU
MAINTAIN
1 2 3 4
DMX
IN
DMX
THRU
MAINTAIN
(cover removed for clarity)
(cover removed for clarity)
F-Drive W1 CC Driver: single RJ45
output, Category-type* cable
Chroma Card: single RJ45 output,
Category-type* cable
FTW-150 Card: single RJ45 output,
Category-type* cable
CC-150 Card: single RJ45 output,
Category-type* cable
F-Drive R12 with output cards (back view)
Four daisy-chained
Navis 100 RGBW luminaires
Four daisy-chained
Navis 100 Fade to Warm
luminaires
Four daisy-chained
Navis 100 White luminaires
Four daisy-chained
Navis 100 White luminaires
F-Drive W1 FTW Driver: single RJ45
output, Category-type* cable
Four daisy-chained
Navis 100 FTW luminaires
120 Ωterminator
(RGBW only)†
Note: *
If you are installing Navis luminaires, you must use 0.25mm2(23AWG) or larger
conductors in Category-type cable. Not all Cat5 or Cat6 cables meet this requirement.
Note: †
Navis 100 RGBW luminaires are not self-terminating. You must terminate the last
luminaire in line with a 120
Ω
resistor.
An RJ45 terminator is included with each F-Drive series Chroma Card. To purchase extra
RJ45 terminators, please contact your ETC customer service representative and request part
number N4086.
Note:
Connect only the same types of luminaires in a wiring run. Do not mix White, Fade
to Warm, and RGBW luminaires in the same wiring run.

ETC Reference Guide
F-Drive Series Wiring
F-Drive Series Wiring Page 3 of 7 ETC
Constant Current Driver Configuration
CAUTION:
Setting the F-Drive CC-150Card or W1CVDriver to output more
current than the manufacturer recommends for the loads may reduce the lifetime
or cause damage to the load.
The CC-150Card in the F-Drive R12 Driver and the W1CCDriver are set by default to provide the
appropriate current for ArcSystem Navis 100 White luminaires (600 mA), but can output 200–700mA
for compatibility with ArcSystem Pro One-Cell luminaires and third-party loads. Output current can
be configured via RDM. See
ArcSystem Pro Series on the next page
and the
F-Drive R12 Series
Installation Manual
or the
F-Drive W1 Series Installation Manual
for more details.
Category-Type Cable Requirements
ArcSystem Navis Luminaires typically connect to the F-Drive W1Driver or F-Drive R12 output card
via Category-type cable terminated to RJ45 connectors. Up to four luminaires can be daisy-chained
along one run of cable when using the RJ45 output from an output card. ArcSystem Navis luminaires
require:
•
0.25mm2(23AWG) or larger conductors in Category-type cable
•
100 m (328 ft) maximum wire run length (including twice the stem length of the pendant
accessory if you are installing a pendant)
•
2.4 A maximum per cable
Cable Bundling
Note:
Cable bundling limitations apply to F-Drive R12 Class 2 output cables. For
reference on maximum number of four-pair cables in a bundle, see NFPA 70 2020 National
Electrical Code, table 725.144.
The conductors in the category-type cable have a maximum current that they can carry before
exceeding the temperature rating of the cable. This limit restricts the number of cables that can be
bundled together.
Navis Luminaire Current Requirements
•
1–4 daisy-chained Navis 100 RGBW luminaires require 1 Aacross 3 wire pairs
•
1–4 daisy-chained Navis 100 White luminaires require 0.7 A per wire pair
•
1–4 daisy-chained Navis 100 Fade to Warm luminaires require 0.45 A per wire pair
Limits for 75°CRated Cable
The current requirements of each Navis luminaire type limit the number of four-pair cables per
bundle. The limits below are for cable with 0.25mm2(23AWG) conductors rated to 75°C:
•
19 four-pair cables per bundle if any cables go to Navis 100 RGBWluminaires
•
91 four-pair cables per bundle if all cables go to Navis 100 White luminaires or a combination
of Navis 100 White and Navis 100 Fade to Warm luminaires
•
192 four-pair cables per bundle if all cables go to Navis 100 Fade to Warm luminaires
Patching Requirements
If you are using a patch panel between the F-Drive W1Driver or F-Drive R12 output card, pins must
be rated for more than 1A.

ETC Reference Guide
F-Drive Series Wiring
F-Drive Series Wiring Page 4 of 7 ETC
ArcSystem Pro Series
ArcSystem Pro White and FTWluminaires can be wired to the F-Drive Series Constant Current
Drivers using the two-pin outputs. Each luminaire requires its own cable and two-pin output from the
output card. See the
F-Drive R12 Series Installation Manual
or the
F-Drive W1 Series Installation
Manual
for pinout details.
1 2 3 4
DMX
IN
DMX
THRU
MAINTAIN
CC-150 Card: one two-pin terminal output and
0.2–2.5 mm2(26–14 AWG) class 2 wire per luminaire
F-Drive R12 with output cards (back view)
Four ArcSystem Pro
One-Cell White or FTW
luminaires
(Standard, Small, or Micro)
F-Drive W1 CC Driver: one two-pin terminal output and
0.2–2.5 mm2(26–14 AWG) class 2 wire per luminaire
Four ArcSystem Pro
One-Cell White or FTW
luminaires
(Standard, Small, or Micro)
Note:
ArcSystem Pro One-Cell luminaires have different wire color conventions on their
input cables. See the table below for wire colors and see the
F-Drive Series R12 Installation
Manual
or
F-Drive Series W1 Installation Manual
for the pinouts of the four two-pin
terminals on the output card or driver.
Luminaire Wire Color and Polarity
Red Black
ArcSystem Pro One-Cell (standard) negative (-) positive (+)
ArcSystem Pro One-Cell Small negative (-) positive (+)
ArcSystem Pro One-Cell Micro positive (+) negative (-)

ETC Reference Guide
F-Drive Series Wiring
F-Drive Series Wiring Page 5 of 7 ETC
Constant Current Driver Configuration
The CC-150Card in the F-Drive R12 Driver and the W1CCDriver can output 200–700 mA for
compatibility with ArcSystem Pro One-Cell White and FTWluminaires and third-party loads. Output
current can be configured via RDM. See
ArcSystem Navis on page2
and the
F-Drive R12 Series
Installation Manual
or the
F-Drive W1 Series Installation Manual
for more details. ArcSystem
luminaire current requirements are below.
CAUTION:
Setting the F-Drive CC-150Card or W1CVDriver to output more
current than the manufacturer recommends for the loads may reduce the lifetime
or cause damage to the load.
Note:
ArcSystem Pro One-Cell Micro luminaires require 200 mA and should only be run
by a CC-150Card or W1CCDriver output channel configured to 200 mA.
ETCLuminaire Current Requirement
ArcSystem Navis 100 White 600 mA
ArcSystem Pro One-Cell White or FTW 600 mA
ArcSystem Pro One-Cell Small White or FTW 600 mA
ArcSystem Pro One-Cell Micro White or FTW 200 mA

ETC Reference Guide
F-Drive Series Wiring
F-Drive Series Wiring Page 6 of 7 ETC
Third-Party Loads
CAUTION:
Setting the F-Drive CC-150Card or W1CCDriver to output more
current than the manufacturer recommends for the loads may reduce the lifetime
or cause damage to the load.
The F-Drive R12 Driver with CC-150Card and F-Drive W1CCDriver are capable of driving
third-party constant current loads, and the F-Drive R12 Driver with CV-150Card and F-Drive
W1CVDriver are capable of driving third-party constant voltage loads. Each R12 output card or W1
driver provides four output channels with the specifications listed below:
Type of Load Driver Number of Output
Channels Limits Per Channel Limits per Output
Card or Driver
Constant Current F-Drive R12 Driver with
CC-150Card
4 per card 200–700mA*
50 W
150 W
F-Drive W1CCDriver 4
Constant Voltage F-Drive R12 Driver with
CV-150Card
4 per card 24 VDC†
50 W
150 W
F-Drive W1CVDriver 4
*Output current can be configured via RDM. See the
F-Drive Series R12 Installation Manual
or the
F-Drive
Series W1 Installation Manual
for more details.
†See
Voltage Drop on the facing page
.
Note:
The maximum output of the CC-150 Card, CV-150 Card, W1 CC Driver, and W1
CV Driver is 50 W per channel and the combined maximum output for all four channels is
150 W. Do not bus/bridge channels to attempt to exceed the individual channel limits.
Example: A CV-150Card can be used to power one 3.9m (12ft 9in) segment of
24VDC, 9.5W/m LED tape on each channel.
CV-150 Card: one two-pin terminal output and
0.2–2.5 mm2(26–14 AWG) class 2 wire per channel
F-Drive R12 with output cards (back view)
One 3.9 m (12 ft 9 in) segment
of 24 VDC, 9.5 W/m LED tape
on each channel

ETC Reference Guide
F-Drive Series Wiring
F-Drive Series Wiring Page 7 of 7 ETC
ArcSystem ArcLamp
The F-Drive R12 with ArcLamp150Card has four output channels. Each output channel can support
up to eight ArcSystem ArcLamps with a total of up to 32 ArcLamps per card. Fixtures with ArcLamps
can be wired to the two-pin outputs of the ArcLamp150Card.
ArcLamp-150 Card: one two-pin terminal output and
0.2–2.5 mm2(26–14 AWG) class 2 wire per channel
F-Drive R12 with output cards (back view)
Up to eight ArcLamps
per channel
Voltage Drop
Voltage drop along load wiring is an issue for constant voltage loads. Voltage drop calculations vary
by project and are based on the type, length, and gauge of wire. The CV-150Card and the
ArcLamp150Card have an adjustabledial on the front of the driver card to set the 24–28 VDC (+/-
5%) output. Measure the voltage at the load and adjust the dial to achieve 24 VDC at the load.
Contact a qualified electrician and see the
F-Drive Series R12 Installation Manual
or
F-Drive Series
W1 Installation Manual
for additional information.
ArcLamp
Voltage drop is an important factor to consider when determining the installation location of an R12
with an ArcLamp150Card. The installation location determines the maximum wire distance to the
ArcLamp loads. For your convenience, an interactive voltage drop calculator is available at
etcconnect.com/ArcLamp.
Other manuals for F-Drive Series
1
This manual suits for next models
1
Table of contents
Other ETC DC Drive manuals
Popular DC Drive manuals by other brands

Lenze
Lenze L-force 8400 Series Mounting instructions

Santerno
Santerno IRIS BLUE user manual

American Control Electronics
American Control Electronics LGC440 manual

ABB
ABB ACH580 Series Installation, operation and maintenance manual

WEG
WEG WECM-AL80-85A2 Installation, operation and maintenance manual

INVT
INVT Goodrive350-19 Series Operation manual