ETC Reference Guide
F-Drive Series Wiring
F-Drive Series Wiring Page 3 of 7 ETC
Constant Current Driver Configuration
CAUTION:
Setting the F-Drive CC-150Card or W1CVDriver to output more
current than the manufacturer recommends for the loads may reduce the lifetime
or cause damage to the load.
The CC-150Card in the F-Drive R12 Driver and the W1CCDriver are set by default to provide the
appropriate current for ArcSystem Navis 100 White luminaires (600 mA), but can output 200–700mA
for compatibility with ArcSystem Pro One-Cell luminaires and third-party loads. Output current can
be configured via RDM. See
ArcSystem Pro Series on the next page
and the
F-Drive R12 Series
Installation Manual
or the
F-Drive W1 Series Installation Manual
for more details.
Category-Type Cable Requirements
ArcSystem Navis Luminaires typically connect to the F-Drive W1Driver or F-Drive R12 output card
via Category-type cable terminated to RJ45 connectors. Up to four luminaires can be daisy-chained
along one run of cable when using the RJ45 output from an output card. ArcSystem Navis luminaires
require:
0.25mm2(23AWG) or larger conductors in Category-type cable
100 m (328 ft) maximum wire run length (including twice the stem length of the pendant
accessory if you are installing a pendant)
2.4 A maximum per cable
Cable Bundling
Note:
Cable bundling limitations apply to F-Drive R12 Class 2 output cables. For
reference on maximum number of four-pair cables in a bundle, see NFPA 70 2020 National
Electrical Code, table 725.144.
The conductors in the category-type cable have a maximum current that they can carry before
exceeding the temperature rating of the cable. This limit restricts the number of cables that can be
bundled together.
Navis Luminaire Current Requirements
1–4 daisy-chained Navis 100 RGBW luminaires require 1 Aacross 3 wire pairs
1–4 daisy-chained Navis 100 White luminaires require 0.7 A per wire pair
1–4 daisy-chained Navis 100 Fade to Warm luminaires require 0.45 A per wire pair
Limits for 75°CRated Cable
The current requirements of each Navis luminaire type limit the number of four-pair cables per
bundle. The limits below are for cable with 0.25mm2(23AWG) conductors rated to 75°C:
19 four-pair cables per bundle if any cables go to Navis 100 RGBWluminaires
91 four-pair cables per bundle if all cables go to Navis 100 White luminaires or a combination
of Navis 100 White and Navis 100 Fade to Warm luminaires
192 four-pair cables per bundle if all cables go to Navis 100 Fade to Warm luminaires
Patching Requirements
If you are using a patch panel between the F-Drive W1Driver or F-Drive R12 output card, pins must
be rated for more than 1A.