manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eterna
  6. •
  7. Light Fixture
  8. •
  9. Eterna YD630NM Setup guide

Eterna YD630NM Setup guide

Ifyou experience problems:
If your lightisdefectiveor developsafault, pleasereturn ittothe placewhere you boughtit. You can call our Helpline
for advice.The Helpline will gladlygiveadviceonanyaspectofanyEterna Lighting product butmaynotbe able to
givespecificinstructionsregarding individual installations.
Ifindoubt,consultaqualified electrician.
Helpline:
Tel:01933 673 144 Fax: 01933 678 083Email: sales@eterna-lighting.co.uk
For answers tofrequently asked questions (FAQs)and other information visit our web-site
www.eterna-lighting.co.uk
Lampreplacement:
> Switchoff the electricityatthe mains.
> Removethe diffuser.
> Twistand withdraw the tube.
> Insert newtube.
> Restore the power and perform operation check.
> Replacediffuser.
Replacementlamptype:
Wattage:8W
Type:T5fluorescenttube
Replacementbatterytype:
2.4V Ni-Cad
7030-0621
Cleaning:
> Clean this light fitting only withasoft drycloth—Do
not useany chemicalor abrasivecleaners.
Batteryreplacement:
If after routine operation check,the lampdoes not
remain lit for the three hour period, anew battery pack
may be required.
1) Switchoff the electricityatthe mains.
2) Allow batteries tofully discharge then reconnectto
supply and allow tocharge for 24 hours.
3) Test again for 3hours, iflight does not remain lit
change the battery packasfollows:
4) Removethe diffuser.
5) Removethe twoscrews indicated on the gear tray
and open the fitting.
6) Unplug the battery lead fromthe circuit board.
7) Removethe twoscrews in the top ofthe gear tray
beneaththe lampthat secure the batterypack in
placeand lift the battery packout ofthe fitting.
8) Writecurrent dateon the new batterypack.
9) Fit new battery packsecuring in placeusing the
screws removed fromthe old pack.
10)Plug battery pack intocircuitboard.
11)Closeand secure gear tray
12)Replacediffuser.
13)Restore power and allow tocharge for 24 hours.
14)Perform full operation check and updatetest record.
Eventually, you may wanttoreplace thislightfitting:
When your lightfitting and or batterypack cometothe end oftheir lifeor you choosetoupdateor
upgrade the fitting byreplacing it,pleasedo notdisposeofitwithyournormal household waste,please
recycle where facilitiesexist.When youneed todisposeofthisfitting,checkwithyourretailer or local
authority for suitable options. Newregulationswill encourage therecycling ofWastefromElectrical and
Electronic Equipment (European “WEEE Directive”effectiveAugust 2005 ).
PLEASE READ THESE INSTRUCTIONSBEFOREINSTALLING
YOUR NEWFITTING
--
PLEASE RETAINFORFUTUREREFERENCE
Non-maintained emergency
bulkhead light8W
Model(s)
YD630NM
Specification:
Power 8W
Continuous illumination >3hours @45Lm
Battery 2.4V 4.5Ah
Recharge time ~20 hours
Over-discharge protection Yes
BLF
EBLF
30.2%
17.7%
Read thisfirst:
> Thislightfittingmust beinstalledinaccordance
withtheBuilding Regulationsmakingreference
totheWiringRegulationsBS7671. The Building
Regulationsmaybe obtained fromHMSO orviewed
and downloadedfrom www.communities.gov.uk
following the link for Building Regulations.
> Switchoffthe mainsbefore commencing installation
and removethe appropriatecircuit fuse.
> Your emergency fittingsshould havetheir own
separatemainssupplycircuitand should notshare
their supply withother lighting or electrical devices.
> Suitable for indoor or outdoor use.
> Thisproduct issuitable for installation on flammable
surfaces (indicated by the "F"in atriangle )
> Before making fixing hole(s),checkthatthere are no
obstructionshidden beneaththe mounting surface
suchas pipes or cables.
> The chosen location ofyour newfitting should allow
for theproduct tobe securelymounted(e.g.toa
ceiling joist )and safelyconnected tothe mains
supply (lighting circuit).
> Ensure thatthe fitting willbe accessibleafter
installation for maintenance.
> If the location ofyour newfitting requiresthe
provision ofanewelectrical supply, the supplymust
conformwiththe requirements ofthe Building
Regulationsmaking referencetothe Wiring
Regulations (see above).
> Makeconnectionstothe electrical supplyin
accordancewiththe following code:
Live-Brownor Red
Neutral -Blue or Black
Earth-Green and Yellow
> This product must be connected toEarth.
> You are advised ateverystage ofyour installation to
double-check anyelectrical connectionsyou have
made.After you havecompleted your installation
there are electrical tests thatshould be carried out:
thesetestsare specified in the Wiring Regulations
(BS7671 )referred tointhe Building Regulations. If
in doubt, consult aqualified electrician.
Installation:
1) Undo the screws ateachend ofthe diffuser and lift
off.
2) Press the tabsateachend ofthegear traytoopen
the fitting..
3) Gentlyprizeone ofthe hingesoff ofitsplasticpin
and lift offthe gear tray.
4) Makethecable entryand fixing holesasrequired.
Inside thebackofthe fitting,there are markingsto
assistyou.
5) Using thebackofthe fittingasatemplate,markthe
position of the fixing holes on your mounting surface.
6) Makefixing holes and fit plugs asappropriate.
7) Secure the back ofthe fitting tothemounting surface
using suitable fixings (notsupplied ).
8) Applyasiliconsealanttothe fixingsifmoisture- or
weather-proofing is required.
9) Fitting acable gland will alsobe necessaryif
moisture- or weather-proofing is required.
10)Thread the supplycable through the entrypointand
intothe fitting.
11)Press the gear trayback intoposition on the hinge
pinsand allowthe gear traytohang open.Make
connection tothe mainssupplyaccording tothe
colour code opposite.Takecare nottoleaveany
strandsprotruding fromthe terminalsand totighten
all terminalssecurely. Ensure alsothatthe terminals
clampontothe bare wire and not ontothe insulation.
12)Writethe current dateon the batterypack.
13)Connect the batterypacktothe circuitboard.
14)Closethe gear tray and pressbackontothe clips.
15)Replacethe diffuser.
16)Restore the powersupply. The LEDshould lightto
indicatecorrect charging.
Operation checks:
Periodictesting should be carried outmonthlyby
simulating afailure ofsupply, causing the fitting tobe
energised fromit’sbattery.Interruption ofthe supply
should be carriedout by the operation ofalocal keyswitch
or other isolation device.During thisperiodall fittings
should be examinedvisuallytoensure thattheyare
functioning correctly. Atthe end ofthe test period the
supplyshall be restored and all indicatorlampsordevices
checked toensure thatthe normal supplyhasbeen
restored.
Safetymarkings: IP65
The duration of the simulated failure shall be:-
Eachmonth:
Isolatethe power supplyand checkthe lightis
illuminated.Thistestshouldlastforno more than
45 minutes.Endorsethetest recordformsupplied.
Everysixmonths:
Isolatethe power supplyand check thatthe lightis
stillilluminated after 1hour.Endorsethe testrecord
form.
Once eachyear:
Isolatethe power supplyand check thatthe lightis
stillilluminated after 3hours.Endorsethe test
record form.
Pleasekeepthisinstruction bookletand testrecord
inasafeplace.Afire officer or other authorised
person maywanttosee yourrecord ofinspection
and testing.
Importantnotes:
Pleasekeepthisinstruction bookletand testrecord
inasafeplace.Afire officer or other authorised
person maywanttosee yourrecord ofinspection
and testing.
The ballastand controlgearmustbe operatedonly
withinthe enclosure supplied. The gear must not be
operated outside ofthe enclosure.
The batterychargingcircuitandDCballastare
separated fromthe mainsbyatleastbasic(single
layer )insulation.
When energised byaconstantmainssupply,the
batterywillbe constantlycharged.Onfailure ofthe
constantmainssupply,the fitting willswitch
automaticallyusing transistorised switching from
batterycharging tobatterydischarge illuminating
the lamp.Boththe mainsandbatterysupplies
incorporatefuseprotection:seefittingfor location
and rating.
YD630NM Non-maintained emergency bulkhead light 070809PA

Other Eterna Light Fixture manuals

Eterna AC44180 User manual

Eterna

Eterna AC44180 User manual

Eterna LEDMIRROR User manual

Eterna

Eterna LEDMIRROR User manual

Eterna vnanobh User manual

Eterna

Eterna vnanobh User manual

Eterna PIR Series Setup guide

Eterna

Eterna PIR Series Setup guide

Popular Light Fixture manuals by other brands

Blizzard StormChaser Supercell manual

Blizzard

Blizzard StormChaser Supercell manual

Chauvet MiN Spot user manual

Chauvet

Chauvet MiN Spot user manual

RSA Lighting Combolight LV Series AR70 LV Specifications

RSA Lighting

RSA Lighting Combolight LV Series AR70 LV Specifications

Rush MH 5 Profile user manual

Rush

Rush MH 5 Profile user manual

nordlux Lotus quick start guide

nordlux

nordlux Lotus quick start guide

tau 800LL installation instructions

tau

tau 800LL installation instructions

Eternal Lighting CUBE4 user manual

Eternal Lighting

Eternal Lighting CUBE4 user manual

USAG 889 L instruction manual

USAG

USAG 889 L instruction manual

Philips Calculite IS-PE instruction sheet

Philips

Philips Calculite IS-PE instruction sheet

XanLite HOME VL01DCCW user manual

XanLite

XanLite HOME VL01DCCW user manual

MOLTO LUCE CONCEPT F Mounting instruction

MOLTO LUCE

MOLTO LUCE CONCEPT F Mounting instruction

RAB Lighting FALCOR 80W installation instructions

RAB Lighting

RAB Lighting FALCOR 80W installation instructions

Chauvet J-Five user manual

Chauvet

Chauvet J-Five user manual

IMG Stage Line LE-302 instruction manual

IMG

IMG Stage Line LE-302 instruction manual

PROEL SG CLSPOT user manual

PROEL

PROEL SG CLSPOT user manual

Halo PR8M Series instructions

Halo

Halo PR8M Series instructions

Chauvet Intimidator COLOR LED user manual

Chauvet

Chauvet Intimidator COLOR LED user manual

Rego T Series user guide

Rego

Rego T Series user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.