manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ETI
  6. •
  7. Measuring Instrument
  8. •
  9. ETI 810-145 User manual

ETI 810-145 User manual

Other ETI Measuring Instrument manuals

ETI BlueTherm User manual

ETI

ETI BlueTherm User manual

ETI 810-130 User manual

ETI

ETI 810-130 User manual

ETI ENA33LCD Troubleshooting guide

ETI

ETI ENA33LCD Troubleshooting guide

ETI 6500 User manual

ETI

ETI 6500 User manual

ETI 810-130 User manual

ETI

ETI 810-130 User manual

ETI 9035 User manual

ETI

ETI 9035 User manual

ETI SIGNALS User manual

ETI

ETI SIGNALS User manual

ETI 8000 User manual

ETI

ETI 8000 User manual

ETI DEC-1 User manual

ETI

ETI DEC-1 User manual

ETI BLUETHERM ONE User manual

ETI

ETI BLUETHERM ONE User manual

ETI 8100 User manual

ETI

ETI 8100 User manual

ETI BlueTherm Probe User manual

ETI

ETI BlueTherm Probe User manual

ETI ETI 7000 User manual

ETI

ETI ETI 7000 User manual

ETI 810-180 User manual

ETI

ETI 810-180 User manual

ETI 8051 User manual

ETI

ETI 8051 User manual

ETI 810-130 User manual

ETI

ETI 810-130 User manual

ETI 810-180 User manual

ETI

ETI 810-180 User manual

ETI 9200 Series User manual

ETI

ETI 9200 Series User manual

ETI 810-195 User manual

ETI

ETI 810-195 User manual

ETI MOISTURE ALERT User manual

ETI

ETI MOISTURE ALERT User manual

ETI 7000 User manual

ETI

ETI 7000 User manual

ETI ENA3D User manual

ETI

ETI ENA3D User manual

ETI THERMAQ BLUE User manual

ETI

ETI THERMAQ BLUE User manual

ETI 825-505 User manual

ETI

ETI 825-505 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTRUMENT OPERATION - Open the battery compartment and insert battery supplied.
For the most accurate recording of ambient temperatures, the Therma-Hygrometer unit
should be positioned away from direct sunlight and draughts.
MAX/MIN - Press the MAX/MIN button to display the maximum reading ('MAX' symbol
displayed). Press the MAX/MIN button again to display the minimum reading ('MIN' symbol
displayed). Press MAX/MIN button again to return to normal readings. To clear the MAX and
MIN readings press the 'CLEAR' button when viewing the MAX or MIN readings.
Please note: Max/Min readings are not saved
so if the battery is removed or drained the Max/
Min readings will be cleared.
°C/°F - Press the °C/°F button on the back of
the instrument to switch between Centigrade
and Fahrenheit.
COMFORT INDICATORS - This unit displays
comfort icons in the %rh display to show if the
surrounding atmosphere is too dry, just right or
too damp.
BATTERY REPLACEMENT - Replace the battery
when the display dims, using an AAA or 1.5 volt
equivalent. The battery is located under the
battery cover at the rear of the instrument.
EMC/RFI - Instrument performance may be
affected if operated within a high frequency
radio eld, such as near a mobile phone, or if subjected to an electrostatic shock.
GUARANTEE - This instrument carries a one-year guarantee against defects in either
components or workmanship. During this period, products that prove to be defective will, at
the discretion of ETI, be either repaired or replaced without charge. The product guarantee
does not cover damage caused by fair wear and tear, abnormal storage conditions,
incorrect use, accidental misuse, abuse, neglect, misapplication or modication. Full details
of liability are available within ETI’s Terms & Conditions of Sale at etiltd.com/terms. In line
with our policy of continuous development, we reserve the right to amend our product
specication without prior notice.
20 °C 27 °C Temperature
(°C)
NO
COMFORT COMFORT
DRY
NO
COMFORT
DRY DRY
WET
Humidity (%)
70 %
50 %
WETDRY COMFORT
THERMA-HYGROMETER
Operating Instructions
Product code:
810-145
WET WET
Range - temperature 0 to 50 °C
Range - humidity 10 to 99 %rh
Resolution - temperature 0.1 °C/°F
Resolution - humidity 1 %rh
Accuracy - temperature
±1 °C
Accuracy - humidity
±5 %rh (30 %rh - 70 %rh at 25 °C)
Battery 1.5 volt AAA
Battery life 10000 hours
Display Dual custom LCD
Dimensions 20 x 100 x 110 mm
Weight 135 grams
Specication
Supplied by
Electronic Temperature Instruments Ltd
Worthing · West Sussex · BN14 8HQ
01903 202151 · sales@etiltd.com · etiltd.com 810-145/01.10.18