manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ETI
  6. •
  7. Measuring Instrument
  8. •
  9. ETI DEC-1 User manual

ETI DEC-1 User manual

This manual suits for next models

1

Other ETI Measuring Instrument manuals

ETI 810-130 User manual

ETI

ETI 810-130 User manual

ETI ETI-8051 User manual

ETI

ETI ETI-8051 User manual

ETI THERMAPEN ONE BLUE User manual

ETI

ETI THERMAPEN ONE BLUE User manual

ETI BLUETHERM ONE User manual

ETI

ETI BLUETHERM ONE User manual

ETI 8000 User manual

ETI

ETI 8000 User manual

ETI 8051 User manual

ETI

ETI 8051 User manual

ETI ETI 7000 User manual

ETI

ETI ETI 7000 User manual

ETI 810-195 User manual

ETI

ETI 810-195 User manual

ETI BlueTherm Probe User manual

ETI

ETI BlueTherm Probe User manual

ETI ENA3D User manual

ETI

ETI ENA3D User manual

ETI 810-130 User manual

ETI

ETI 810-130 User manual

ETI 810-145 User manual

ETI

ETI 810-145 User manual

ETI 9200 Series User manual

ETI

ETI 9200 Series User manual

ETI 8100 User manual

ETI

ETI 8100 User manual

ETI 810-140 User manual

ETI

ETI 810-140 User manual

ETI 7000 User manual

ETI

ETI 7000 User manual

ETI BlueTherm User manual

ETI

ETI BlueTherm User manual

ETI 8100 User manual

ETI

ETI 8100 User manual

ETI 6500 User manual

ETI

ETI 6500 User manual

ETI THERMAQ BLUE User manual

ETI

ETI THERMAQ BLUE User manual

ETI 9035 User manual

ETI

ETI 9035 User manual

ETI DEC-2 User manual

ETI

ETI DEC-2 User manual

ETI 810-130 User manual

ETI

ETI 810-130 User manual

ETI 8000 User manual

ETI

ETI 8000 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Meter front description
El. meter
Merilni instrument
Mjerni instrument
Miernik
Měřící přístroj
Merací prístroj
Fogyasztásmérő
El. Energijos skaitiklis
Измерительный прибор
Elekro enerģijas skaitītājs
Elektriarvesti
Messgerät
DEC-1
004804050
ETI, d.o.o., Obrezija 5, SI-1411 Izlake
www.etigroup.eu/products-services
- 3 - - 4 -
- 1 - - 2 -
Dimensions
Compliance
Purpose
Functioning
A special electronic system under the influence of flowing current
and applied voltage generates pulses proportional to the drawn
energy. Energy consumption is indicated by a flashing LED. The
amount of pulses is converted into energy input, and its value is
displayed by the segment LCD display. The fractional digits repre-
sent the hundredths (.01 kWh = 10 Wh).
MID Directive 2014/32/EU
DEC-1 is a static (electronic) calibrated electricity meter of single-
phase alternating current in a direct system.
Pulse output
The meter is equipped with pulse output SO+ – SO-. This allows you
to connect another pulse device (SO) that reads pulses generated
by the meter.
No additional connected equipment is required for proper opera-
tion of the meter.
Sealing
The meter has sealable input and output terminal covers to pre-
vent any attempts to bypass the meter.
Meter number
The meter is marked with individual serial number allowing its
unambiguous identification. The marking is laser engraved and
cannot be removed.
LCD display
kWh reading LED
terminal
covers
sealing points
4,0
62,8
45
52
116,2
18
3 8 3 8 8 9 5 6 2 0 7 2 3
D190125
Technical data
reference voltage
base current 0.25÷5 A
maximum current 50 A
minimum current 0.02 A
accuracy class B
compliance 2014/32/EU Directive
MID declaration TCM 221/12-4791
own power consumption <8 VA; <0.4 W
indication range 0÷99999.99 kWh
meter constant (1 Wh/pulse) 1000 pulses/kWh
kWh read-out signalling red LED
SO+ SO- pulse output open collector
SO+ SO- connection voltage <12÷27 V DC
SO+ SO- connection current <27 mA
SO+ SO- constant (1 Wh/pulse) 1000 pulses/kWh
SO+ SO- pulse duration 90 ms
SO+ SO- wire length <20 m
working temperature -25÷55°C
terminal 6 mm² screw terminals
housing PC+ABS material
dimnesions 1 module (18 mm)
mounting on the TH-35 rail
protection level IP20
230 V AC, 50 Hz
Connection scheme
- 5 - - 6 -
Assembly
1. Disconnect the power.
2. Mount the indicator on a rail in the distribution box.
3. Connect input phase to terminal 1. Connect wire N to terminal 4.
4. Connect a measured circuit or a single receiver to terminal 3
(output phase L) and to terminal 6 (N).
5. Optionally connect the RS-485 network wires to the 20 (A+) – 21
(B–) terminals.
6. Put the covers on the terminals and optionally seal them.
- 7 -
General safety conditions
* Please read the manual carefully prior to installing the meter.
* The meter should be installed and operated by qualified person-
nel familiar with the construction, operation and any hazards
involved.
* Do not install the meter if it is damaged or incomplete.
* The user is responsible for proper grounding, selection, instal-
lation and functionality of any other devices connected to the
meter, including security devices such as overcurrent protection
breakers, differential switches and surge protectors.
* Before connecting the power supply make sure that all cables are
connected properly.
* Always follow the operational conditions of the meter (voltage,
humidity, temperature).
* In order to avoid electric shock or damage to the meter, discon-
nect the power before each change in connection configuration.
* Do not modify the device on your own, as this may cause damage
or improper operation of the meter and consequently expose
the users to risk. In these cases the manufacturer is not liable for
ensuing events and reserves the right to refuse the warranty
claims on the counter
- 8 -
1000imp/KWh
230V 0,25-5(50)A 50Hz
kWh
DEC-1 MID
21 20
13
46
L L
OUTIN
SO
N