19
2096580-16-11/22 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-A-.5
EN
12.1.1. Technical data for safety switch CES-A-.5
Parameter Value Unit
min. typ. max.
Housing material PBT GF30
Dimensions Acc. to EN 60947-5-2 mm
Weight 0.4 kg
Ambient temperature at UB= 24 V DC -20 - +55 °C
Degree of protection IP65/IP67
Degree of contamination 3
Rated insulation voltage Ui- 300 1) - V
Rated impulse withstand voltage Uimp - 1.5 - kV
Rated conditional short-circuit current 100 A
Shock and vibration resistance Acc. to EN 60947-5-3
Installation orientation Any
Connection M12 plug connector, 8-pin; shield can be connected
Operating voltage UB(regulated, residual ripple < 5%) 18 24 27 V DC
The following applies to the approval acc. to UL Operation only with UL Class 2 power supply or equivalent measures
Current consumption 80 mA
Switching load acc. to UL max. DC 24 V, Class 2
External fuse (operating voltage UB) 0.25 - 8 A
Power supply for output load U(+LA)/U(+LB) 18 24 27 V DC
Safety outputs (LA/LB, 2 semiconductor outputs, p-switching,
short circuit-proof, electrically decoupled)
- Output voltage U(LA/U(LB) 2)
HIGH U(LA) U(+LA) - 1.5 - U(+LA)
HIGH U(LB) U(+LB) - 1.5 - U(+LB) V DC
LOW U(LA)/U(LB) 0 - 1
Switching current per safety output 1 - 400 mA
External fuse (U(+LA)/U(+LB), safety circuit 0.4 A medium slow-blow
Utilization category DC-13 24 V 400 mA
Monitoring output (OUT, semiconductor output, p-switching,
short circuit-proof)
- Output voltage 0.8 x UB- UBV DC
- Output current - - 20 mA
Risk time 3) - - 180 ms
Discrepancy time - - 120 ms
Ready delay 4) - - 3 s
Dwell time 5) 0.5 - - s
Switching frequency - - 1 Hz
Repeat accuracy R acc. to EN IEC 60947-5-2 - - 10 %
Mounting distance between 2 read heads or 2 actuators 80 - - mm
EMC protection requirements Acc. to EN 60947-5-3
LED displays STATE LED green: Normal operation
Flashing: Teach-in operation
OUT/ERROR LED yellow: Actuator detected
OUT/ERROR LED red: - EMC interference
- Internal electronics fault
- Invalid teach-in operation
Reliability values acc. to EN ISO 13849-1 6) CES-A-.5E-... CES-A-.5H-...
Category 3 4
Performance Level (PL) PL e PL e
PFHD4.29 x 10-8 / h 3.7 x 10-9 / h
Mission time 20 20 years
Diagnostic coverage DC 90 99 %
1) Tested by employers’ liability insurance association up to 75 V.
2) Values at a switching current of 50 mA without taking into account the cable lengths.
3) Maximum OFF time for the safety outputs following removal of the actuator.
4) After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set LOW during the ready delay.
5) The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).
6) Refer to the declaration of conformity in chapter 16 for the issue date.