GENERAL SAFETY PRECAUTIONS
2. INTENDED USE AND APPLICATION
Kit contents
2.2 Technical features
3. INSTALLATION
3.1 Preliminary checks
3.2 Tools and materials (not included)
3.3 Wiring
3.4 Installing the operator
Quotes from ground
Pillar brackets
4. MANUAL RELEASE
5. MAINTENANCE
6. PHASING OUT AND DISPOSAL
Outward opening
Pillar bracket T1
2.3 Operator dimensions
......................................................................................................................
.............................................................................................................................
...................................................................................................
...................................................................................................
................................................................................................................... page
.............................................................................................................................
page
page
page
page
page
page
page
.....................................................................................................................
................................................................................................................. page
page
page
page
page
page
page
page
page
Gate bracket S3 (for Stilo only)
............................................................................................... page
Gate bracket S4 (for Stilo S only)
............................................................................................. 08
page
........................................................................................................................................................
.................................................................................................................................................................
...............................................................................................................................

1 11_2016
.
01
02
03
04
05
1
2
3
45
1
23
45
23
45
2
1
3
45
1
01
02
03
04
05
n°2
n°2
n°1
n°2
n°2
n°1
1. GENERAL SAFETY PRECAUTIONS
This manual contains important information for the safety of consumers.
An improper installation can result in serious jury to objects and people.
Carefully read and follow all safety precautions identified with this warning symbol
Save this manual for future consultation.
Always cut the power when installing. Make sure the earth connection is properly connected.
Use and installation of the product must comply with Machinery Directive 2006/42/CE. Verify that the system is
EN 124445 and EN 12453 standard compliant. Installation must be carried out by expert qualified personnel who knows
the potential hazards associated and in full compliance with current regulations.
Use of the product must be restricted to its intended use. Any other use is to be considered dangerous and therefore forbidden.
Do not allow children to play with the fixed command devices, or in the gate’s area of operation.
Keep any remote control devices (i.e. transmitters) away from the children as well.
2. INTENDED USE AND APPLICATION
STILO operator is designed to automate swing gates. The use of this product for purposes other
than those described above and installation executed in a manner other than as instructed in this technical
manual are prohibited. All STILO systems are irreversible, therefore no electric-lock is needed.
In case of power cut the gate operator can be easily released by manual operation.
KIT STILO Double-leaf composition
STILO Motors
Pillar brackets T1
Fixing pack PR1-G1
Gate brackets S3
Release key
Installation manual
2.1 KIT CONTENTS
n°2
n°2
n°2
n°2
n°2
n°1
KIT STILO S Double-leaf composition
STILO S Motors
Pillar brackets T1
Fixing pack PR1-G1
Gate brackets S4
Release key
Installation manual

2
Stilo 3:
Stilo 4:
Stilo 3:
Stilo 4:
130
Stilo S4: 1040 mm
130
STILO 4 STILO S4
24Vdc
0,5-0,75A
50W
--
--
2500N
44
1600 rpm
120°deg
20”
300Kg
3,00m
80%
230V~50Hz
1,2-1,7A
300W
10µF
150°C
3000N
44
1400 rpm
120°deg
22”
400Kg
3,00m
40%
115V~60Hz
3,1-3,3A
300W
20µF
150°C
3000N
44
1700 rpm
120°deg
18”
400Kg
3,00m
40%
V
A
W
µF
C°
N
IP
rpm
deg
s
Kg
m
%
STILO 4 rev
24Vdc
0,5-0,75A
50W
--
--
2500N
44
1600 rpm
110°deg
20”
200Kg
2,50m
80%
230V~50Hz
1,2-1,7A
300W
10µF
150°C
3000N
44
1400 rpm
110°deg
22”
350Kg
2,50m
40%
115V~60Hz
3,1-3,3A
300W
20µF
150°C
3000N
44
1700 rpm
110°deg
18”
350Kg
2,50m
40%
230V~50Hz
1,2-1,7A
250W
8µF
150°C
2500N
44
900 rpm
120°deg
22”
350Kg
3,00m
40%
STILO 3
24Vdc
0,5-0,75A
50W
--
--
2500N
44
1600 rpm
120°deg
15”
250Kg
2,00m
80%
230V~50Hz
1,2-1,7A
300W
10µF
150°C
3000N
44
1400 rpm
120°deg
17”
350Kg
2,00m
40%
115V~60Hz
3,1-3,3A
300W
20µF
150°C
3000N
44
1700 rpm
120°deg
15”
350Kg
2,00m
40%
Motor power supply
Max draw.
Power
Capacitor
Thermal protection
Adjustable thrust
Protection rating
Revolutions
Opening angle
Opening time (90°)
Leaf weight
Leaf length
Duty cycle
2.2 TECHNICAL FEATURES
3. INSTALLATION
3.1 Preliminary checks
Before installing make sure:
Weight, dimensions and gate construction are proper for the operator you intend to buy
Proper mechanical stops are already in place
The gate swings freely
The opening of the automated gate is not an entrapment hazard as regards any surrounding fixed parts and there is sufficient space for manual
release
Any lawn watering devices will not wet the gearmotor from the bottom up
The earth cable is properly connected
Do not install onto gates on either an upward or downward slope
(i.e. that are not on flat, level ground)
2.3 OPERATOR DIMENSIONS
Open = 1140 mm
Open = 1240 mm
Closed = 815 mm
Closed = 915 mm

3
3.2 TOOLS AND MATERIALS (NOT INCLUDED)
brick
Ø 18mm
concrete
Ø 15mm
inox/alu. tubular stainless steel
PILLARS AND WALLS
LEAF
stainless steel/alu wood
3+3 3+3 3+3 3+3
2+2 2 +2

4
B
Crx 4 x 0,50 mm²
C¹ tx 2 x 0,50 mm²
D
E
230V
mm²
mm²
2 x 0,50
2 x 0,50
A
a
b
e
d
c
c
a
a
c1
c1
3.3 WIRING INSTALLATION OVERVIEW
N.B.: The number of tubes and cables
(not included in the kit) depends on the type of
the accessories employed
INNER VIEW
OUTER VIEW
Cut off the power before starting wiring
A circuit breaker should be fitted close to the gate (3 mm wires) to protect both the gate control panel and the house main fuse box. A 6A
automatic breaker or a 16A single phase breaker complete with fuses shall be suitable.
Make sure you have suitable tubing and conduits for the electrical cables: feed the motors, control panel and accessories separately, in order to
prevent interferences that may result in bad operation.
Fit the power cable keeping a curve as shown in picture B, in order to avoid water blackflow inside the operator. (pic. B)
(pic. A)
Ram 3 x 1,5 + T
Control panel 2 x 1,5 + T
Photocells
Photocells
Key switch
Flashing light
pic. B

5
h min= 15 cm
h max= 60 cm
Stilo 3 A=150 B=150
Stilo 4 A=200 B=200
BB
B
A
B
D
90°
C
minimo
150 mm
Stilo 3 = max 150 mm
Stilo 4 = max 175 mm
3.4 INSTALLING THE OPERATOR
The ram operators are supplied handless version, it means they can be installed either on the right or left side of the gate (see picture C).
Make sure that suitable ground stops (B) for opening and closing position of the leaves are in place.
B= mechanical ground stops
3.4.1. QUOTES FROM GROUND
The operator has to be fitted keeping a height from ground between 40 and 50 cm. See picture D.
If the gate is particularly light, fit the operator as closer as possible to gate centerline.
3.4.2. PILLAR BRACKETS – How to determine fixing dimensions
The ideal approach is to fix the brackets complying with the measures A and B as indicated in the below table
for an opening angle of 90° (picture E).
Pic. D
Pic. E
right
Motor
left
Motor
Pic. C
To determine the position of bracket S4:
Put the gate in closing position
Release the operator (see paragraph 4)
Move forward the front pivot of the operator until it reaches the position of limit switch in opening. Leave 20mm of space between the pivot
and the operator end (fig. O)
Fasten bracket S4 to the front pivot of the operator as indicated in pic. Q keeping in mind that the threaded hole of the rotating pivot must be
turned down and that the dragging pivot milling must be placed longitudinally to the hole (pic. P).
Put the operator on the gate’s wing keeping it levelled and mark the position of bracket S4 on the gate.
Weld or bolt bracket S4 to the gate.
Control that the drag pin has been positioned with the two sides of the milling in parallel position to the button hole of the alum. tube as
indicated in the pic. Q.

6
3.3.2. CONSIGLI PER L’INSTALLAZIONE
Tutti i collegamenti devono essere effettuati in assenza d’alimentazione.
Prevedere un dispositivo di sezionamento onnipolare nelle vicinanze dell’apparecchio (i contatti devono essere di
almeno 3mm). Proteggere sempre l’alimentazione per mezzo di un interruttore automatico da 6A, oppure per mezzo
di un interruttore monofase da 16A completo di fusibili.
Le linee di alimentazione ai motori, alla centrale e di collegamento agli accessori devono essere separate onde evitare
disturbi che potrebbero generare mal funzionamenti dell’impianto.
Il cavo elettrico in uscita dall’attuatore non deve essere teso ma fare un’ampia curva verso il basso onde evitare il
riflusso di acqua all’interno dell’attuatore stesso (fig.B)
fig. B
3.4 FISSAGGIO MOTORI
Identificare gli attuatori sinistro e destro in base alla figura (fig. C): se le cerniere sono sulla destra l’attuatore
è destro, viceversa se sono sulla sinistra. Accertarsi che il cancello sia dotato di fermi meccanici in apertura e in chiusura (fig. D)
Fig . C
B B
B
B = Ferm i m eccanici
Fig . D
3.4.1. DETERMINAZIONE ALTEZZA DI FISSAGGIO ATTUATORI
L’altezza di fissaggio consigliata è compresa tra 40-50 cm (fig.E).
In caso di cancelli con struttura leggera, tenere l’attuatore più vicino possibile alla mezzeria del cancello.
Fig . E
h min= 15 cm
195 160 210 235
205 240 215 190 165
185 260
140
120 145 135 160140
180 155 165 140160
1140 1170 1150 1130 1100 1080
990 990 1000 1000 980
h max= 60 cm
motore sinistro motore destro
170 195 160 185 210 235
230 205 240 215 190 165
860 870 840 820 800
140 140 140 140
80 110 140 140 140 140
80 110 140
Stilo 3 Stilo 4 Stilo S4
80 80
840
260
165
800
140
110
80
If this ideal scenario of A and B is not applicable, then refer to the below table to determine the brackets position
(values are expressed in mm)
Bracket quota
Minimum Leaf
length
3.4.3. OUTWARD OPENING
It's possible to have your gate opening outward (pic. F-G)
Pic. F
Pic. G
Bracket quota
Minimum Leaf
length
Bracket quota
Minimum Leaf
length

711_2016
T1
PR1
G1
3.4.3. PILLAR BRACKET T1
Anchor the pivot bracket S1 onto the pillar by welding or bolting (Ø 13 mm bolts) , making sure the quotas shown
in the previous table are met. Ensure to keep a minimum distance of 30 mm from the pillar edge as shown in picture H.
In cases of masonry pillars, use chemical or resin to secure bolts or stone (cement) the bracket into position. Brackets T1 as well are supplied in two
versions, left hand and right hand and match the according motor (see picture I). Fix motor into bracket T1 and place the pivot pin PR1 though the holes.
Keep the pivot pin PR1 oriented downward. See picture L.
3.4.4. GATE BRACKET S3 (for Stilo only)
To determine the position of bracket S3:
Put the gate in closing position
Release the operator (see paragraph 4)
Extend the arm fully
Turn back the arm 2 cms. This avoids the motor to “leap forward”(pic. M)
Affix the bracket S3 to the motor slot as illustrated in picture M. Place the pivot pin PR1 into the locating hole.
Mount the arm of the motor onto the gate. Ensure the arm is perfectly straight.
Pic. H
Pic. L
oriented
downward
RIGHT
LEFT
Pic. I
Pic. N
Pic. M
NB.
Check the manual opening of the leaf before
definitively fixing the bracket to make sure the gate
can open fully to your required angle.

20 mm
8
3.4.5. GATE BRACKET S4 (for Stilo S only)
To determine the position of bracket S4:
Put the gate in closing position
Release the operator (see paragraph 4)
Move forward the front pivot of the operator until it reaches the position of limit switch in opening. Leave 20mm of space between the pivot
and the operator end (fig. O)
Fasten bracket S4 to the front pivot of the operator as indicated in pic. Q keeping in mind that the threaded hole of the rotating pivot must be
turned down and that the dragging pivot milling must be placed longitudinally to the hole (pic. P).
Put the operator on the gate’s wing keeping it levelled and mark the position of bracket S4 on the gate.
Weld or bolt bracket S4 to the gate.
Control that the drag pin has been positioned with the two sides of the milling in parallel position to the button hole of the alum. tube as
indicated in the pic. Q.
Pic. O
Pic. P
Pic. Q
Milling
Button hole

9
4. MANUAL RELEASE
5. MAINTENANCE
Periodic maintenance is needed. We suggest checking the state of lubrication and tightness of the anchoring
screws on the operator as well as the good operation of all safety devices.
6. PHASING OUT AND DISPOSAL
DO NOT DISPOSE OF IN NATURE!
Some components may contain hazardous waste. They must, thus, be removed and turned in to licensed firms
for their disposal. Before acting always check the local laws on the matter.
Insert the key into the lock barrell and turn it at 90° (see pic. R), then turn the complete lock system at 90° as well (see pic. S).
Now you can manually open and close your gate.
If you wish to lock back your system, simply put the lock system to its original position and turn the key at 90°.
It doesn't matter if the gate is opened, closed or whatever. At the first start command the control unit will go back to its default values.
Pic. R Pic. S
Via Neive 77, 12050 Castagnito (CN)
+39 0173 210132 www.euromaticgate.net
This manual suits for next models
1
Table of contents
Other Euromatic Gate Opener manuals
Popular Gate Opener manuals by other brands

Siemens
Siemens POS8.4420/109 Basic documentation

Platinum Access Systems
Platinum Access Systems BARRIER Installation instructions manual

CAME
CAME BX704AGS installation manual

CAB
CAB HD.18 AC Operating instructions and spare parts catalogue

CAME
CAME 001AX3024 installation manual

RIB
RIB K500 Simplified instructions