EVA Logik ZW47 User manual

Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
ZW47 Z-Wave Plus Double Plug
ZW47 Z-Wave Plus Double Plug
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from
state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS WARNING
Model:ZW47
RISK OF FIRE
Power: 120 VAC, 60 Hz.
RISK OF ELECTRICAL SHOCK
Signal (Frequency): 908.42 MHZ.
RISK OF BURNS
Maximum load for outlet 15A, 1200W Resistive
CONTROLLING APPLIANCES:
Maximum load for the Z-Wave controlled outlet:
EXERCISE EXTREME CAUTION WHEN USING Z-Wave DEVICES TO CONTROL
600W Incandescent, ½ HP Motor or 1200W Resistive
APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT
Range: Up to 100 feet line of sight between the Wireless Controller
ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
and the closest Z-Wave receiver module.
MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES
Operating Temperature Range: 32-104° F (0-40° C)
MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
Specifications subject to change without notice
OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
due to continuing product improvement
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
Website:www.nie-tech.com
DO NOT USE Z-Wave DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Introduction:
The ZW47
is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network.
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
ZW47 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Key Features:
---Remote ON/OFF control via the Z-Wave controller
---Manual ON/OFF control with the front panel push button
---Support Association Group and Auto Report switch status
---Support 5V 2A USB Charging
---Support Z-Wave Range Test Tool
---Support firmware upgrades via Over-the-air (need Gateways support)
Product Overview:
A Z-Wave controlled outlet-1
B Z-Wave controlled outlet-2
C ON/OFF PROG Button
D USB Charging 5V 2A
E AC plug
F RGB LED Indicate
Key Function Description
Function 1: Press button one times to turn the outlet1 ON or OFF
Function 2: Press button two times quickly to turn the outlet2 ON or OFF
Function 3: Press and hold button for 2 seconds to turn the outlett1and Outlet2 ON or OFF
Function 4: Press button three times quickly to ADD and REMOVE
Function 5: Press and hold button for 6-8 seconds to Z-Wave Range test tool
Function 6: Press the button twice quickly and then press and hold the button 10S.device will reset
(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable)
Function 7: Press button six times quickly to Change Parameter 17 Value(circulate)
LED Indicate Description
1:LED Indicate Power Meter
White = Plug is off
Dark Blue = 0 – 300 W
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
A
E
D
C
B
F
Dark Blue = 0 – 300 W
Cyan = 300 – 600 W
Green = 600 – 900 W
Orange = 900 – 1200 W
Red = 1200 – 1500 W
Purple = 1500 – 1800 W
Purple blink = over 1800 W
2:LED Indicate Z-Wave Range Test Tool
SolidGreen=directcommunicationwiththeprimarycontrollerisstable
Flashinggreen=directcommunicationwiththeprimarycontroller,butthesignalisnotgood
Solidorange=communicationwiththeprimarycontrollerviarepeaternodes,thesignalisstable
Flashingorange=communicationwiththeprimarycontrollerviarepeaternodes,butthesignalisnotgood
Solidred=communicationwiththeprimarycontrollerhasfailed
Z-Wave Remote Control
ADD or Remove the ZW47 from the existing Z-Wave home control network with your primary controller.
---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
Include ZW47 to/from a Z-Wave Gateway with supporting Security.The ZW47 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by
Z-WaveTM Controller means “Remove” or “Exclusion”.
Z-Wave MULTI_CHANNEL
ZW47 is multi channel device
,
It has three endpoints. Outlet-1 is Endpoint1, outlet-2 is Endpoint2. USB is Endpont3.
ZW47 Endpoint1 / Endpoint2 Device Type
Generic Device Class: GENERIC_TYPE_SWITCH_BINARY
Specific Device Class: SPECIFIC_TYPE_POWER_SWITCH_BINARY
---When prompted by your primary controller, click the PROG button Three times in one second.

Z-Wave protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_METER
COMMAND_CLASS_SECURITY_
2,
COMMAND_CLASS_MULTI_CHANNEL
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_METER
COMMAND_CLASS_FIRMWARE_UPDATE_MD
ZW47 protocol Endpoint 1
Full Command Class Node Info
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_METER
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY_
2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_METER
ZW47 protocol Endpoint 2
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_METER_V4,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY_
2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_METER,

ZW47 protocol Endpoint 3
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY
Z-Wave Configuration Parameters
1:
Restores state after power failure
Paramter No: 1(0x01) Size:1 Byte Value: 00(default) The state before a power outage.
Value: 01 outlet on
Value: 02 outlet off
2:
Power Wattage Report Value Threshold(Wattage) Value Scope :0----65535W
Paramter No: 2(0x02) Size:4 Byte Value: xx xx xx xx (Default 10W)
Value: 00 00 Disabled
3:
Power Wattage Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 3(0x03) Size:4 Byte Value: xx xx xx xx (Default 30S)
4:
Energy (kWh) Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 4(0x04) Size:4 Byte Value: xx xx xx xx (Default 300S)
5:
Voltage (V) Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 5(0x05) Size:4 Byte Value: xx xx xx xx (Default 300S)
6:
Electricity (A) Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 6(0x06) Size:4 Byte Value: xx xx xx xx (Default 300S)
You may use the below configuration parameters to change settings of the corresponding functionality.
Paramter No: 6(0x06) Size:4 Byte Value: xx xx xx xx (Default 300S)
7:
Overload Protection (Current) Value Scope :1----16A
Paramter No: 7(0x07) Size:1 Byte Value: xx (Default 13A)
8
:
Endpoint1 Enable
Auto Turn-OFF Timer
Paramter No: 8(0x08) Size:1 Byte Value=0 Auto Turn-OFF Timer
Disabled (default);
Value=1 Auto Turn-OFF Timer
Enabled
9:
Endpoint1 Count Down Configuration(Turn off the output by time
)
Paramter No: 9(0x09) Size:4 Byte Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
10
:
Endpoint1 Enable
Auto Turn-ON Timer
Paramter No: 10(0x0A) Size:1 Byte Value=0 Auto Turn-ON Timer
Disabled (default);
Value=1 Auto Turn-ON Timer
Enabled
11:
Endpoint1 Count Down Configuration(Turn on the output by time
)
Paramter No: 11(0x0B) Size:4 Byte Value: xx xx xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
12:Endpoint2 Enable
Auto Turn-OFF Timer
Paramter No: 12(0x0C) Size:1 Byte Value=0 Auto Turn-OFF Timer
Disabled (default);
Value=1 Auto Turn-OFF Timer
Enabled
13:Endpoint2 Count Down Configuration(Turn off the output by time
)
Paramter No: 13(0x0D) Size:4 Byte Value: xx xx xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
14:Endpoint2 Enable
Auto Turn-ON Timer
Paramter No: 14(0x0E) Size:1 Byte Value=0 Auto Turn-ON Timer
Disabled (default);
Value=1 Auto Turn-ON Timer
Enabled
15:Endpoint2 Count Down Configuration(Turn on the output by time
)
Paramter No: 15(0x0F) Size:4 Byte Value: xx xx xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
16:Manual Control
Paramter No: 16(0x10) Size:1 Byte Value=0
Manual Control Disabled
Value=1 Manual Control
Enabled
(default);
17:Status LED Configuration
Paramter No: 17(0x11) Size:1 Byte (default:Value=01 )
Value: 00 LED indicator will display power consumption whenever the device is plugged in
Value: 01 LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF
Value: 02 LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off
Value: 02 LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off
Value: 03 Always OFF

Support for Association Groups
ZW47 supports 3 association groups. Group 1 support 1 node ID,Group 2--3 Support maximum of 5 node ID’s
Association group_1:Z-Wave Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW47 Status change report,
1. ZW47 will trigger AUTO report function if the Switch status had been changed.
Association group_2:basic set command
send out a related basic set command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command
send out a related basic set command. On (0xFF) or Off (0x00) to its associated group.
Support for Overload Protection
ZW47 support Overload Protection ,When the ZW47 load exceeds the overload setting value, the overload signal is sent out
Notification Type : Overload 0x08 . Event :Overload detected 0x08
Restoring Factory Defaults
ZW47 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
When the output of the ZW47 Enpoint2 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically
When the output of the ZW47 Enpoint1 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically
Table of contents
Other EVA Logik Home Automation manuals

EVA Logik
EVA Logik ZW36 User manual

EVA Logik
EVA Logik ZW36M User manual

EVA Logik
EVA Logik ZW37 User manual

EVA Logik
EVA Logik ZW96S User manual

EVA Logik
EVA Logik ZW303 User manual

EVA Logik
EVA Logik NST003 User manual

EVA Logik
EVA Logik WF96 User manual

EVA Logik
EVA Logik ZW96 User manual

EVA Logik
EVA Logik ZW30 User manual

EVA Logik
EVA Logik ZW39 User manual
Popular Home Automation manuals by other brands

Nortek Security & Control
Nortek Security & Control Gocontrol PD300EMZ5-1 quick start guide

GBF
GBF MR920 user manual

Energeeks
Energeeks EG-EW007MC Quick installation guide

Olimpia splendid
Olimpia splendid 2261 quick start guide

ITEAD
ITEAD S20 Smart Socket user guide

Ksenia
Ksenia lares 4.0 Programming manual