Warning
To minimise the risk of fire, electric shock, personal injury
and/or damage to the product please observe the following:
• Please always read the manual and only use the product in accordance with the
manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.
• All installations must be carried out by properly qualifi ed personnel in accordance with
national legislation and regulations.
• This product must be earthed. Get assistance from an qualifi ed electrician when in doubt.
• Ensure that the chimney has been swept before mounting the fi lter to avoid chimney fire.
• The product must be accessible for service and maintenance.
• Prior to servicing the product, disconnect the power supply to the fi lter. Turn off the main
switch located on the fi lter. Ensure that the heat source and the fi lter cannot be turned on
accidentally. Let the fi lter cool down before service or cleaning.
• Automatic power on/off function; when connected to a pellet boiler, high voltage is swit-
ched on, when the pellet boiler starts. Touching the electrode or the electrode holder may
be fatal.
• Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is
installed.
• If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please
ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-
ved, a smoke alarm must be installed in the same room as the heat appliance.
• Undesirable stoking practice may result in problems, such as excessive soot accumulation,
chimney fi res, etc., which may damage the product.
Product description
The ESP-25 is an electrostatic precipitator (particle lter) for pellet boilers for inline installation in indoor
chimney constructions and is placed directly after the pellet boiler. The ESP-25 is designed to reduce the
level of particles from pellet boilers.
The ESP-25 is intended for non-condensing pellet boilers with a maximum heating output of no more than
25 kW and can only be used on chimney constructions with negative pressure.
The ESP-25 is supplied on a standard Ø150 uninsulated ue, with a 5-metre-long supply cable with strip-
ped conductors for plug installation.
If the pellet boiler is not adjusted for proper combustion, it may cause problems with soot, chimney res,
etc., which may damage the product. Please follow the instructions from the manufacturer of the pellet
boiler.
Scope of supply
• ESP-25 with 5-metre connection cable (with stripped conductors)
• Installation manual and user instructions
• Cleaning brush and handle
• Brush stop
• 3x Warning labels
An adapter for mounting the ESP-25 in an existing chimney must be ordered separately.
Accessories and spare parts
The table below shows the accessories and spare parts available for the ESP-25 model.
Accessories* Spare parts
Adapters** Electrode
Insulator
Controller
Cleaning brush
*This manual does not describe the specic use of accessories. We refer to the separate manuals for such components.
For more details contact your Exodraft dealer.
**Following adapters are currently available:
• Ø150 double male
• Ø150 double female
• Ø130-Ø150 double male increaser
• Ø130-Ø150 dobule female increaser
For other types we refer to suppliers of chimney adapters, for example chimney manufactures.