Eye Hortilux Platinum Series User manual

Thankyouforpurchasingourproduct.Carefullyreadallinstructionslistedbelow.Doingsowillensureyearsofsafeandreliable
operationofthisproduct.
PLEASENOTE:Duringlampstartupyouwillhearsoundscomingfromthelamp/ballast.Thisisnormalforlowfrequencyoperation
andisNOTaproblemwiththelamporballast.Oncethelampwarmsuptonormaloperatingtemperaturethesoundwillbe
reducedsignificantly.
WARNING:
RISKOFELECTRICSHOCK
Disconnectpowerbeforeinspection,installationorremoval•Inputpowercordshallbepluggedintoanelectricallygrounded
receptacle•Donotexceedratedinputballastvoltageratings•Ensurepowercordandlampcordareproperlyconnectedbefore
operating•Donotattempttodisconnectlampcordwhileballastisoperating•Donotoperateballastwithoutlampinstalled•
Remoteoutputconnectionshallnotexceed15feetfromballasttolampsocket•Useprovided14/3AWGinputpowercordonly•
TheballastandassociatedcomponentsmustbemountedandwiredinaccordancewithNational,StateandMunicipalCodes.
RISKOFFIRE
Suitableforindooruseonly•Keepcombustiblematerialsawayfromballastduringoperation•Maintainaminimum8inchesside‐
to‐side,andend‐to‐enddistancebetweenotherballastsand/orobstructions.•Usewithafixtureratedforthisproduct•Usewith
lamptypesS52orM47only•Foruseonlywithproductshavingthismanufacturer’smatingconnector(adaptorsareavailable)
_______________________________________________________________________________________
Contents:Carefullyunpackallcontents:
1. HORTILUXPlatinumSeries1000WattElectronicBallast
2. 120voltpowercord(240voltsoldseparately)
3. HORTILUXLU1000B/HTL/ENlamp
_________________________________________________________________________________
Mounting:Findasuitablelocationtolocate/mountyourHORTILUXPlatinumserieselectronicballast.
1. Thislocationmustbeprotectedagainstmoistureandwithin230to1040Fahrenheittemperaturerange(‐50Cto400C)
2. Thislocationmustbewithinoutletreachforthe6footpowercord(1.82Meters).
3. Theballastcanbesetonaflatsurfacesuchasaworkbenchorfloor.
4. WallmountingOptions:
•MountingscrewsareNOTincluded;usesuitablescrewsappropriateforthemountingsurfaceandballastweight
•Verticalwallmounting‐coolingfanMUSTfaceupwardwithcordsetsfacingdownwardforproperairflow
•Horizontalwallmounting‐fancanfaceleftorright
•MULTIPLEelectronicballastmounting.Besuretospaceballasts8inches(20.3cm)aparttoallowsufficient
cooling.
NewInstallation:
1. Determinemainpowersupplyyouaregoingtouse:
a. 120V(powercordincluded)
b. 240V(powercordsoldseparately)
2. MakesuretheON/OFFswitchontheelectronicballastisintheOFFposition
3. InstallyournewHORTILUXLU1000lampintoyourreflector/socket
4. Connectthemainpowercordtoyourballastandtoagroundedoutlet.(Marked“Input”)
(over)

5. Connectthelampcord(notincluded)whichrunsfromyourreflector/lamptotheelectronicballast(Marked“Output”).
ThisistheplugjustbelowtheON/OFFswitch.NOTE:IfusingaSunSystemRreflector/hood,besuretoconnecttheplug
“ears”topreventaccidentallampcorddisconnection.
6. TurnONtheelectronicballast.Thelampshouldstartwithinseveralseconds.
ExistingLightSystemInstallation:
1. TurnOFFyourexistingballast
2. Disconnectpowertoexistingballast
3. Disconnectthelampcordthatrunsfromtheballasttoyourfixture/lamp
4. FollowtheinstructionslistedaboveforNEWinstallations
RemoteMounting:
TheHORTILUXPlatinumserieselectronicballastmaybeinstalledupto15feetawayfromthereflector/lamp.Distancesgreater
than15feetmaycausepotentialstartingissuesthatcanresultindamagetotheballastand/orlamp.
OperatingInstruction:
TurntheON/OFFswitchtotheONpositiontostartthelamp.Ifusinganautomatictimeritmustberatedfor15amps.
Troubleshooting:
•Thiselectronicballastisbuiltwithaninternalcircuitbreaker.IfthecircuitbreakertripsOFF.Pleasecheckforanyelectrical
problemsonyoursystem.Toresetthecircuitbreaker,cycletheON/OFFswitchONthenOFFtoresetthecircuitbreaker.
TurningtheswitchONwillrestartpowertothelamp.
•MetalHalideandHighPressureSodiumlampsmayrequireupto15minutestorestartaftershutdown.Pleaseallow
sufficienttimeforthelampstocooldownpriortorestarting.
_____________________________________________________________________________________________________
EYELIGHTINGINTERNATIONALOFNORTHAMERICAINC.EXCLUSIVEPLATINUMSERIESE‐BALLASTLIMITED
WARRANTYANDEXCLUSIVEREMEDY
ThefollowingexclusivelimitedwarrantyandremedyshallapplytoEYELightingInternationalofNorthAmerica’sHORTILUX™
PlatinumSeriese‐Ballasts.
EYELightingInternationalofNorthAmerica(“EYELighting”)warrantsHORTILUX™PlatinumSeriese‐Ballaststobefreefromdefects
inmaterialandworkmanshipduringtheperiodendingfiveyearsafterthedateofsaleor,ifunknown,afterthedateofmanufacture
providedthatsuche‐ballastsareoperatedtoIwasakiElectricandEYELightingspecificationsaswrittenontheInstallationInstruction
Sheetwithintheballastpackaging.
WARRANTYADMINISTRATIONPOLICY
1.EYELightingInternationaloffersthiswarrantyONLYtopurchasersofHORTILUX™Platinume‐ballastswhopurchasedtheire‐
ballastfromaretailstorethatpurchasedfromadistributorauthorizedbyEYELighting.Thiswarrantydoesnotapplytosecond‐hand
Platinume‐ballastspurchasedpursuanttocasualsales.Allwarrantyclaimsmustbedirectedtotheretailstorewherethee‐ballast
waspurchased.
2.Exceptasprovidedinthiswarranty,neitherEYELightingnorIwasakiElectricCo.,Ltd.,makesanyrepresentationorwarrantyof
anykind,express,impliedorstatutory,astoanymatterwhatsoever,includingwithoutlimitationmerchantability,fitnessfora
particularpurpose,non‐infringementorotherwise.EYELightingandIwasakiElectricherebydisclaimanysuchwarranty.Without
limitingtheforegoing,EYELightingandIwasakiElectricdonotmakeandshallnotbedeemedtohavemadeanywarrantyasaresult
ofanytesting,sampling,orsimilaranalysisthateithermayperform.
3.EYELightingandIwasakiElectricshallnotunderanycircumstancesberesponsibleforanylossordamage,indirect,special,
ordinary,exemplary,consequentialorotherwise,arisingoutofthepurchaseoruseofthee‐ballast,exceptasexpresslyprovidedin
thiswarranty.UndernocircumstancesshallEYELighting’sorIwasakiElectric’sliabilityofanykindexceedthepurchasepriceofthe
e‐ballastinquestion.
4.Anyattempttoopenormodifythee‐ballastwillvoidtheabovewarranty.
5.Anydamagetothee‐ballastasaresultofneglect(i.e.physicaldamageincludingdropping,impacts,improperwiring,improper
mounting,misapplication,andwaterdamage)willvoidthewarranty.
EQS‐N‐36‐76‐00008
This manual suits for next models
1
Table of contents
Other Eye Hortilux Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Eternal Lighting
Eternal Lighting CUBEecho RGBWA user manual

Messagemaker Displays
Messagemaker Displays SID manual

Tridonic
Tridonic EM powerLED BASIC FX 103 SR 50W 50V manual

ABSTRACT
ABSTRACT LUD48-D user manual

SyncroLaser
SyncroLaser SyncroLaser-R user guide

Philips
Philips Softone 871150066257610 Specifications