Installation instructions
6 < <<<
1Dear user
Congratulations on purchasing your Faber product!
A quality product, which provide you with the
warmth and atmosphere for many years. Please
read the user manual before using the fire. Should,
despite the careful final checks, a malfunction
occur, please contact your Faber dealer.
Please note:
The data of your fire is available in the
user manual.
1.1 Introduction
Only have the appliance installed by a qualified
installer according to the gas safety regulations.
Read this installation manual properly.
1.2 Please check
Check the fire for transport damage and report any
damage immediately to your dealer.
1.3 CE Declaration
Glen Dimplex Benelux certifies that this Faber fire
complies with the essential requirements of the
gas appliances directive.
Product: gas room heater
Model: Triple Premium L
Applicable EC directives: 90/396/EEC
Harmonised standards applied: NEN-EN-613
NEN-EN-613/A1
This Declaration is invalid, if without the written
permission of Glen Dimplex Benelux:
Changes are made to the appliance.
The fire is connected to other exhaust
materials than specified.
2Safety instructions
The unit must be installed and checked
every year according to these instructions
and the applicable national and local
regulations.
Ensure that the data on the type label
matches the local gas type and pressure.
The settings and the construction of the
fire must not be changed!
Do not place extra imitation wood or
other smouldering material on the burner
or in the combustion chamber.
The unit is for atmosphere and heating
purposes. This means that all surfaces,
including the glass, can be very hot (over
100°C); exceptions to this are the bottom
of the fire and the control elements.
Do not place any combustible materials
within 0.5 m of the radiation area of the
fire.
Light the fire for the first time and run for
several hours on the highest setting, so
that the paint can cure. Provide adequate
ventilation, so that any fumes can
disperse ; we recommend vacating the
room during this process
Please note
Through the natural air circulation of the
fire moisture and uncured volatile
components from paint, building
materials and carpeted floors, etc. are
attracted. These parts can settle as soot
on cold surfaces. Therefore do not light
the fire shortly after installation.
3Installation requirements
3.1 Fire
This device can be built into an existing or
new chimney.
For devices with flexible gas pipes the gas
regulator block is mounted on the right
side of the fire for transport reason.
The gas regulator block with the receiver
and the I.T.C. must be placed directly
behind a service door. (Fig. 1.5)
3.2 False chimney breast or other
structure
The False chimney should be of non-
combustible material.
The space above the fire should always be
ventilated using the supplied grids or a
similar alternative with minimal free
passage of 200cm² per grid.
3.3 Fluepipe and terminal requirements
For the supply of the combustion air and
the discharge of the combustion gases
you should always use the Flue materials
specified by Faber.
Please note:
Only when using these materials can
Faber guarantee the safe and proper
operation of the appliance.
The outside of the concentric flue material
can heat up to +/-150°C. Ensure, when
penetrating a flammable wall or ceiling,