Fagor VTP 139 SL Reference manual

TAPAS REFRIGERATOR
Manual for installation, use, and maintenance
VTP 139 SL
VTP 175 SL

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page2
www.Fagorcommercial.com
Contents
1 RECEIVING AND INSPECTING THE EQUIPMENT.................................................................................... 3
2 SPECIFICATIONS .................................................................................................................................... 4
3 INSTALLATION....................................................................................................................................... 5
3.1 UNCRATING...................................................................................................................................... 5
3.2 LOCATION ........................................................................................................................................ 5
3.3 DATA PLATE...................................................................................................................................... 6
3.4 LEVELING.......................................................................................................................................... 6
3.5 ELECTRICAL CONNECTIONS.............................................................................................................. 6
4 OPERATION ........................................................................................................................................... 7
4.1 ELECTRONIC CONTROL..................................................................................................................... 7
4.2 OTHER FUNCTIONS ........................................................................................................................ 10
5 MAINTENANCE.................................................................................................................................... 11
5.1 CLEANING THE CONDENSER COIL..................................................................................................11
5.2 GASKET........................................................................................................................................... 12
5.3 DOORS/HINGES..............................................................................................................................12
5.4 DRAIN.............................................................................................................................................12
6 TROUBLE SHOOTING...........................................................................................................................14
7 WIRING DIAGRAMS............................................................................................................................. 15
8 WARRANTY..........................................................................................................................................16

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page3
www.Fagorcommercial.com
1RECEIVING AND INSPECTING THE EQUIPMENT
Up on receiving your new Fagor Refrigerator, check the package and the machine for any
damages that may have occurred during transportation. Visually inspect the exterior of the
package. I f damaged, open and inspect the contents with the carrier. Any damage should be
noted and reported on the delivering carrier’s receipt.
In the event that the exterior is not damaged, yet up on opening, there is concealed damage to
the equipment notify, the carrier immediately. Notification should be made verbally as well as
in written form. Request an inspection by the shipping company of the damaged equipment.
Retain all crating material until inspection has been made. Contact the dealer through which
you purchased the unit.
Check the compressor compartment thousing and visually inspect the refrigeration package.
Be sure lines are secure and base is still intact.
A NOTE FROM OUR QUALITY CONTROL MANAGER
CONGRATULATIONS ON YOUR NEW PURCHASE. WE WOULD LIKE TO WELCOME
YOU TO THE FAGOR TEAM. THE UNIT IN FRONT OF YOU IS A GREAT PIECE OF
EQUIPMENT THAT WILL BECOME ONE OF YOUR MOST RELAIBLE TOOLS IN YOUR
DAILY OPERATIONS FOR YEARS TO COME!
PRIOR TO SHIPPING YOUR UNIT, OUR TRAINED SERVICE TECHNICIANS TESTED
YOUR UNIT FOR A PERIOD OF 12 HOURS. THIS PERFORMANCE TEST WAS
RECORDED AND A COPY OF THE RESULTS IS INCLUDED WITH THIS SERVICE
MANUAL. DURING THIS TEST, OUR HIGHLY QUALIFIED PERSONNEL INSPECTED
YOUR MACHINE FOR LEAKS, LOSE COMPONENTS, AND IMPROPER NOISE
LEVELS. WE ALSO TESTED THE COOLING PERFORMANCE IN AN EFFORT TO GIVE
YOU THE BEST AND MOST RELAIBLE UNIT POSSIBLE.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page4
www.Fagorcommercial.com
2SPECIFICATIONS
Note:
* The pressure in the suction line is recommended at 32°C/90°F maximum of ambient
temperature.
** Superheat measured in the outlet of the evaporator at 32°C/90°F
Model
Trays
Amps
HP
Voltage
Plug
Type
BTU
Refrigerant
charge (oz)
Refrigerant
VTP 139 SL
6
2.3
1/6
120
5-15P
850
6.7
134 A
VTP 175 SL
9
2.3
1/6
120
5-15P
850
6.7
134 A
Voltage 115 60 Hz
Model
Trays
Amps
HP
Voltage
Plug
Type
BTU
Refrigerant
charge (oz)
Refrigerant
VTP 139 SL
6
2.1
1/4
220
5-15P
850
6.7
134 A
VTP 175 SL
9
2.1
1/4
220
5-15P
850
6.7
134 A
Voltage 220 60 Hz

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page5
www.Fagorcommercial.com
3INSTALLATION
3.1 UNCRATING
Remove the outer packaging. Cut the 4 clamps that hold the refrigerator to the skid. Lift the
unit off the skid.
If machine was laid down during this operation, remember to leave the cabinet
up right for 24 hours before connecting to power source.
3.2 LOCATION
Units represented in this manual are intended for indoor use only. Be sure the location chosen
has a floor strong enough to support the total weight of the unit and its contents. For the most
efficient operation, be sure to provide at least three (3) inches between sides, back and top of
the unit.
THE MACHINES NEEDS TO BE INSTALLED 2 FEET AWAY FROM ANY HEAT SOURCES.
The unit should not be installed under ambient temperatures higher than 100 °F.
If the relative humidity is higher than 60 %, the door frames may sweat water. This is not a
malfunctioning of the unit.
WARNING
The following actions will void your warranty:
-Modification of power cord.
-Connecting the unit to any extension cord.
-Neglecting to install the castors or optional legs.
Inside cabinet:
The first cleaning must happen when you unpack the unit and before it is turned ON. For
this, you have to clean the unit with warm water and mild detergent. When it is cleaned and
dry, proceed to install accessories and plug your unit into a dedicated outlet. WAIT 24 HOURS
BEFORE PLACING PRODUCT IN THE UNIT. This will guarantee that it is working properly.
Consequential damages are not covered under warranty.
Outside cabinet:
Be sure that the unit has access to ample air to breathe. Avoid hot corners and locations near
stoves and ovens. It is recommended the unit be installed no closer than 3” from any wall. The
place where the refrigerator is placed must be open and clean. This will reduce the amount of
debris and dirt on the condenser fan and coil.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page6
www.Fagorcommercial.com
3.3 DATA PLATE
The data plate is located inside the cabinet, near the top front, left corner. Under no
circumstances should the data plate be removed from the unit. The data plate is essential to
identify the particular features of your machine and it is of great benefit to installers,
operators, and maintenance personnel. It is recommended that, in the event the data plate is
removed, you copy down the essential information in this manual for reference before
installation. Removal of data plate will void the warranty.
3.4 LEVELING
Set unit in its final location. A level cabinet looks better and will perform better. Effective
condensate removal and door operation will be effected by leveling. Machine must be leveled
front to back and side to side with a level tool. Castors k it w i ll include shims for leveling.
Insert the shim between the castor and the frame rail. (See installation of castors). Lock front
castors so cabinet does not move. Ensure drain hose is inside drain pan.
3.5 ELECTRICAL CONNECTIONS
Refer to the amperage data in this manual, or on data plate, and your local code or the
National Electrical Code to be sure unit is connected to the proper power source. Verify
correct incoming voltage according to the Data Plate information.
Do not, under any circumstances, cut or remove the ground prong from the power cord.
Fagor units must be properly grounded.
NEVER USE AN EXTENSION CORD! Fagor will not warranty any unit that has been
connected to an extension cord.
Fagor equipment must be grounded and connected in accordance with NEC Article 422
Appliances.
Model
Electrical
Refrigerant Type
SERIAL NUMBER FOR
THE EQUIPMENT
(8 digits and ends in
“M”)

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page7
www.Fagorcommercial.com
DANGER: Power must be turned off and disconnected from the power source when ever
performing maintenance, repair or cleaning the condensing unit.
If machine is still running when power is off, disconnect power at the circuit breaker before
unplugging the machine.
WARNING: Machine and compressor warranties are void if failure is due to improper
electrical installation.
4OPERATION
The temperature displayed by the electronic controller is the temperature of the evaporator
of the unit. The temperature of cabinet will be displayed by the analog thermostat provided.
This display refrigerator is design to keep the product inside cold, under any circumstance
leave food overnight, this will make the evaporator to become frozen and compressor
damage may occur. Damages caused by leaving the unit ON overnight with product will not
be covered under warranty.
4.1 ELECTRONIC CONTROL
After connecting your unit, turn ON rocker switch located next to the controller. The display
will light up showing the temperature inside the unit. Also, the compressor and fan icons will
flash for a period of three minutes. After this delay the unit will start cooling.
Compressor Icon
Evaporator Fan Icon
Temperature inside the cabinet
Verify you don't have any alarms on the temperature controller. If after you turn ON the
equipment the controller shows the alarm icon or an error code, call f or technical service.
They will help you fix the problem.
Note: The controller on the equipment is programmed to display internal temperatures in Fahrenheit (°F). To

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page8
www.Fagorcommercial.com
To increase Set Point of Temperature
To turn t h e u n i t ON/OFF without
unplugging the equipment (press and hold 3
seconds)
To change the set point
To access programming mode
To decrease set Point of Temperature.
To set a manual defrost (press and hold 3
seconds),
change to Celsius (°C), see point 4.2
Description of Buttons on the Controller
Changing the set point of the Temperature on the controller
The unit comes with a factory default set point (-8°F Freezers, 32°F Refrigerators). These set
values will make the unit perform at its maximum capacity. Therefore, it is not recommended
to change the set point. If set point needs to be changed, follow the next steps.
Note:
If you change the set point of temperature, the performance of the equipment will change. Changes made in
the parameters of the controller will not be covered under warranty.
1. -Push the SET button for one (1) second. You should see a flashing number. Release the
button.
2. Press the up and down arrows to increase or decrease the set temperature. Then press
the set button to save the new set point.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page9
www.Fagorcommercial.com
Note:
The maximum value you can set in the controller is: For refrigerators: 5°C (40°F)
For freezers: -16°C (2°F)
3. If you wish decrease the value of the set point for a new temperature, press the button
DOWN arrow (see the picture below). Press this button to reach the desired value.
Release the button and then press the SET button to keep, and save, the new value.
Note:
The minimum value you can set in the controller is: For refrigerators: -1°C (30°F)
For freezers: -23°C (-8°F)
Changing the reading temperature from °F to °C
To change the reading of the temperature from °F to °C, you need access to the programming
mode in the controller. To do this, press and hold the SET button for five (5) seconds until “PS”
is shown in the display. Release the button and press the SET button one time. Now you will
see the number zero (0). With the button UP arrow, set a value of “22” and then press the SET
button. You will see the “PS” again. Use the button DOWN arrow to find the parameter “EZY”
and press the SET button one time. Using the UP or DOWN button set a value according to the
chart below.
Note:
Freezer equipment can be used like a refrigerator by selecting the value of the parameter “EZY” according to the
chart above. Refrigerators must never be used like a freezer.
After you chose the value for the “EZY” parameter, press and hold the SET button for 5
For Refrigerators
EZY Value
Application
Temperature in °F
3
Refrigeration
Temperature in °C
4
Refrigeration
For Freezers
EZY Value
Application
Temperature in °F
1
Freezer
Temperature in °C
2
Freezer
Temperature in °F
3
Refrigeration
Temperature in °C
4
Refrigeration

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page10
www.Fagorcommercial.com
seconds.
Y
ou will see the temperature on the display in °F or °C according to
your selection.
4.2 OTHER FUNCTIONS
Manual Defrost
To select manual defrost, hold the button DOWN arrow for 5 seconds. The snow flake icon
will appear on the display. When this icon is solid it indicates that the equipment is in
Defrost mode.
To exit manual defrost, hold the DOWN button arrow for 5 seconds. The snow flake icon will
turn off. Wait 2 minutes for the compressor to start.
Note:
If the equipment doesn’t reach the temperature, first verify that the defrost cycle is not ON.
The unit will go into defrost every six hours for an average of 20 minutes. The defrost cycle is time initiated and
temperature terminated.
NOTE!
Good air flow inside the cabinet is critical. Do not block air flow to the fans. Allow three inches
of space along the front, back, and sides.
CAUTION!
Do not introduce hot foods, chemical or corrosive products, drugs, or
open beverage bottles.
The unit must run for at least 24 hours before any product is placed inside. Failure to do so
may ice up the evaporator coil. Consequently, the unit will never reach the desired set point.
This failure will not be covered under warranty.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page11
www.Fagorcommercial.com
5MAINTENANCE
Stainless Steel Care and Cleaning
Proper cleaning of stain less steel requires soft cloths or plastic scouring pads. Never use steel
pads, wire brushes, or scrapers!
Cleaning solutions need to be alkaline or non-chloride cleaners. Any cleaner containing
chlorides will damage the protective film of the stainless steel. Chlorides are commonly found
in hard water, salts, house hold and industrial cleaners. If a cleaner containing chloride is used,
be sure to rinse repeatedly and dry thoroughly up on completion.
Stainless steel must be c l ea n ed eve r y da y with soap and water. Extreme stains or grease
should be cleaned with an on-abrasive cleaner and plastic scrub pad. When using a stainless
steel chemical cleaner, make sure it is recommended for commercial applications.
Never use an acid based cleaning solution! Many food products have an acidic content which
can deteriorate the stainless steel finish. Be sure to clean ALL food products from any stainless
steel surface. Failure to do so, will result in spots and rust on the surface affected.
5.1 CLEANING THE CONDENSER COIL
DANGER: Power must be turned off and disconnected from the power source whenever
performing maintenance, repair or cleaning the condensing unit.
Disconnect machine. Remove front bottom panel and carefully slide out the condensing unit.
The condenser coil requires regular cleaning. It is recommended every 30-60 days, depending
on the accumulation of dust and grease.
If the build up on the coil consists of only light dust and debris, the condenser coil can be
cleaned with a simple brush. Heavier dust builds up may require a vacuum or even
compressed air to blow though the condenser coil.
If heavy grease is present, there are de-greasing agents available for coils. The condenser coil
may require to be sprayed with de-greasing agent and then to be dried with compressed air.
Be sure all electrical and mechanical parts are dry before turning ON the power.
Never use high pressure water for cleaning the c on d ens e r c o il . Water can damage the

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page12
www.Fagorcommercial.com
electrical components located near or at the condenser coil. Do not place
filter material in front of condenser coil. This material blocks air-flow to the coil similar to
having a dirty coil!
If you keep the Condenser clean, you will minimize your service expense and lower your
electrical costs. Failure to maintain a clean condenser coil can initially cause high temperatures
and excessive run times. Continuous operation with dirty or clogged condenser coils can result
in compressor failures. This will not be covered under warranty.
Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY
To put back the condensing unit, slide in the unit carefully in. BE SURE THE DRAIN PIPEIS
LOCATED OVER THE DRAIN PAN. Replace front bottom panel.
5.2 GASKET
Gaskets require regular cleaning to prevent mold and mildew build up and to keep the
elasticity of the gasket. Gasket cleaning can be done with the use of warm soap and water.
Avoid the use of chemical cleaning products on gaskets as this can cause them to become
brittle and prevent proper sealing. Also, never use sharp tools or knives to scrape or clean the
gasket which could possibly tear the gasket and rip the bellows.
Gaskets can easily be replaced and do not require the use of tools or authorized service
personnel. To remove the gasket, pull the gasket towards you. To replace gasket, press the
gasket against the groove of the door the gasket will “snap” back into place.
5.3 DOORS/HINGES
During transportation the doors hinges may become loose. If the door(s) don’t look aligned,
tighten the screws that hold the hinge brackets to the frame of the unit. If the doors are loose
or sagging, this can cause the hinge to pull out of the frame which may damage the doors and
the door hinges. In some cases, this fix or adjustment may require
a
qualified service agent or
maintenance personnel.
5.4 DRAIN
Each unit comes equipped with a drain pan located outside the unit. The drain pan catches the
condensation produced inside the evaporator coil. If the drain hose become loose or
disconnected from moving or bumping the unit, you may find a puddle of water inside/outside
of the unit. Replace or fix any lose connections.
IF YOU NOTICE EXCESSIVE WATER ACCUMULATION ON THE INSIDE OF THE UNIT, be sure the

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page13
www.Fagorcommercial.com
drain tube is connected firmly and not kinked or bent. It is the owner’s
responsibility to maintain the drain pan leveled, and with the drain hose inside of the pan.
Units installed in a humid environment will produce large amounts of water in
the drain pan. This is NOT a malfunction of the unit. It is the customer’s
responsibility to clear the drain pan as necessary to avoid puddles of water
underneath the unit.
Do not store open containers with liquids inside the unit. This will increase the
amount condensation inside and outside of the unit, and the evaporator coil
will freeze up.
Do not store hot products inside the unit. This will increase the amount of
condensation inside and outside of the unit, and the evaporator coil will freeze
up.
The unit must be level and on a strong surface. When moving the unit, check
the drain piping to make sure it was not disconnected or moved out of the
drain pan. This will not be covered under warranty.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page14
www.Fagorcommercial.com
6TROUBLE SHOOTING
Follow the next steps before requesting warranty service. Failure to do so may
result in service charges for you and may void your warranty:
1)
Refrigerator doesn’t work:
a. Check that the machine is still connected.
b. Check that the ON/OFF button is in the ON position.
2)
Refrigerator doesn’t reach temperature :
a. Verify unit is not on saving mode
b. Check that the thermostat is not in OFF position.
c. Check that the machine is not in the defrost cycle.
d. Ensure Equipment is in a ventilated place and removed minimum of
2 inches from any other appliance and away from any heat source.
e. The environment maximum temperature must be 38 °C / 100°F.
f. To insure proper air flow, product must not be placed higher than
the maximum level mark located on the internal wall of the unit.
g. If FREEZER, check that the temperature is not Celsius (°C).
h. Check that the gasket is in good condition and door is sealed.
i. Check that the fan is moving. Open the door and press and hold
door switch for verification.
j. Don’t put any food inside until the unit has reached the proper temperature.
k. If FREEZER, food must be previously frozen before being placed inside the
cabinet.
l. Be sure castors or legs were installed.
3)
There is water inside the refrigerator:
a. Check that the drain pan inside the cabinet is in position.
b. Check that there is not food clogging the drain line.
4)
There is water under the refrigerator:
a. Check that the drain pipe is over the pan.
b. Check that the cabinet is level.
Warning: To insu re proper operation of equipment, it is recommended that the
unit is ON for 24 hours prior to the introduction of perishables.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page16
www.Fagorcommercial.com
8WARRANTY
AS OF APRIL 1, 2014
Three Years Parts & Labor Warranty: Fagor Commercial, Inc. (“Fagor”) Warrants to the fist-end-user
purchaser (the “User”) that the Fagor brand equipment sold hereunder, except for parts and accessories
which carry the warranty of a supplier (the “Equipment”) will be free from defects in material and factory
workmanship under normal conditions of use and maintenance and upon proper installation and start-up
in accordance with the User manual supplied with each Fagor unit. The obligation of this warranty is
covered by Fagor for a period of three (3) years from the date of installation (Warranty commencement
date), but in no event to exceed thirty-nine (39) months from the date of shipment from Fagor. Warranty is
Not Transferable.
Warranty Coverage: If there is a defect in material or factory workmanship covered by this Warranty
reported to Fagor during the period the applicable Warranty is in force and effect, Fagor will repair or
replace, at Fagor’s option, that part of the Equipment that has become defective and will cover
reasonable labor cost within the corresponding warranty period of time. Fagor shall bear all reasonable
labor costs in connection with the installation of these replacement parts, provided that, the installation is
conducted by Fagor or its authorized representative. Charges for warranty travel time round trip, total two
(2) hours or up to 100 miles total. Any charges exceeding those stated herein must have prior
authorization by Fagor. In case Fagor deems the equipment non-repairable, said equipment will be
replaced and the replacement unit(s) will carry the same warranty period from the original unit’s
installation date (original Warranty commencement date).
Additional Two Year Compressor Part Warranty: In addition to the warranty set above, Fagor warrants the
sealed compressor (part only) for an additional two (2) years based on the original installation date, but
not to exceed thirty-nine (39) months after shipment from the manufacturer. This warranty is for defects,
both in workmanship and material, under the normal and proper use and maintenance service. The two
(2) year extended warranty only applies to sealed parts of the compressor and does not apply to any
other part or component, including, but not limited to cabinet, temperature control, refrigerant, motor
starting equipment, fan assembly, or any other electrical or mechanical component.
Exclusions from and Conditions to Warranty Coverage: This Warranty does not cover parts or
accessories, which (a) carry the warranty of a supplier or (b) are abused. Application of this Warranty is
further conditioned upon the following:
Installation: The Equipment must be properly installed in accordance with Fagor’s installation
procedures and by a professional technician.
No Alteration: The Equipment must not have been modified or altered from its condition at the
date of original installation.
Use: FAGOR EQUIPMENT IS NOT DESIGNED FOR PERSONAL, FAMILY, OR HOUSEHOLD
PURPOSES, AND ITS SALE FOR SUCH PURPOSES IS NOT INTENDED. IN THE EVENT THE
EQUIPMENT IS SO USED, THIS WARRANTY SHALL BE NULL AND VOID, AND THE
EQUIPMENT IS SO USED, THIS WARRANTY SHALL BE NULL AND VOID, AND THE
EQUIPMENT SHALL BE DEEMED TO HAVE BEEN SOLD “AS IS-WHERE IS” WITHOUT ANY
WARRANTY OF ANY KIND, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF TITLE,
NON-INFRINGEMENT, MERCHANT-ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page17
www.Fagorcommercial.com
Proper Maintenance and Operation: The Equipment must be properly
maintained and operated in accordance with Fagor’s maintenance and operating procedures. All
service, labor and parts must be acquired from Fagor or its authorized service representative for
the User’s area.
This warranty is void if failure is a direct result of handling and/or transportation, fire, water,
accident, misuse, acts of god(s), attempted repair by unauthorized persons, improper installation,
if serial number has been removed or altered, or if unit is used for purpose other than it was
originally intended.
Failure to comply with any of these conditions will void this Warranty. In addition, this Warranty does not
cover defects due to apparent abuse , misuse or accident.
Parts Warranty Coverage: Fagor warrants all new machine parts produced or authorized by Fagor to be
free from defects in material and workmanship for a period of 90 days from the Warranty Commencement
Date. If any defect in material and workmanship is found to exist within the warranty period, Fagor will
replace the defective part without charge. Defective parts become the property of Fagor.
Fagor will have no responsibility to honor claims received after the date the applicable Warranty expires.
Notwithstanding the foregoing , any claim with reference to the Equipment or any parts therefore for any
cause shall be deemed waived unless submitted by the User to Fagor within (30) days after the date the
User discovered, or should have discovered, the claim. In connection with all claims under this Warranty,
Fagor will have the right, at its own expense, to have its representatives inspect the Equipment at the
User’s premises and to request all of the User’s records pertaining to the Equipment to determine
whether a defect exists, whether the conditions set forth in this Warranty have been satisfied, and
whether or not the applicable Warranty is in effect.
THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT
EXPRESSLY SET FORTH HEREIN, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR
OTHERWISE, INCLUDING BUT NOT LIMITED TO ANY REPRESENTATION OF PERFORMANCE
AND ANY IMPLED WARRANTIES OF TITLE, NON-INFRINGEMENT, MERCHANTABILITY OR
FITNESS FOR A PARTICLULAR PURPOSE. NO OTHER WARRANTIES ARE AUTHORIZED ON
BEHALF OF FAGOR UNLESS SPECIFICALLY ISSUED BY FAGOR.
Fagor shall have no liability for incidental or consequential losses, damages including without limitation or
expenses, loss of sales, spoiled food, profits or goodwill, claims whether or not on account of refrigeration
failure or punitive or exemplary damages directly or indirectly arising from the sale, handling or use of the
Equipment or from any other cause relating thereto, whether arising in contract, tort, warranty, strict
liability or otherwise. Fagor’s liability hereunder in any case is expressly limited, at Fagor’s election, to
repair or replacement of Equipment or parts therefore or to the repayment of, or crediting the user with,
an amount equal to the purchase price of such goods.

TAPAS CASES SERVICE MANUAL / Rev. JUN. 2015
Page18
www.Fagorcommercial.com
Terms & Conditions
Prices & Specifications: Fagor reserves the right to change the prices and specifications of the equipment
and/or material without notice. Prices are FOB Fagor warehouses. All orders are subject to acceptance
by Fagor Commercial, Inc.
Terms: All orders are subject to credit approval. All Invoices not paid within the specified terms will be
subject to a 1.5% per month delinquency charge. Buyer agrees to pay all costs of collection including
such attorney’s fees as may be allowed by law.
Taxes: This price list does not include any Federal, State, City or Local taxes, which may apply and are
subject thereto.
Shipment: Requested carrier will be used upon request. Fagor has the right to ship via any responsible
carrier if requested carrier is unavailable. Shipping charges are payable by consignee and any claims
arising as such charges shall be resolved between the carrier and the consignee. Shipping dates are
approximates. Fagor is not responsible for any delays in deliveries that are beyond our control.
Damaged Merchandise: Inspect shipment for any damage, before accepting it. If damaged, open and
inspect the contents with the carrier. Any damage should be noted and reported on the delivering carrier’s
receipts. Fagor assumes nor responsibility for damages while in transit.
Concealed Damage: If there is concealed damage to the equipment, notify the carrier immediately.
Notification should be made verbally as well as in written form. Request an inspection by the shipping
company of the damaged equipment. Retain all crating material until inspection has been made.
Cancellations & Returns: Cancelled orders and returned merchandise are subject to a 25% restocking
and handling charge. Written authorization is required for a return of any equipment. All equipment
returned must be in its original factory crate; freight prepaid and must be in the same condition as
originally shipped by Fagor. Returns will only be authorized within 30 days of invoice date.
Warranty: Register your product with Fagor Commercial to validate you warranty. Service calls must be
made directly through Fagor service department. 1-(866)-463-2467 or e-mail:
us.service@onneragroup.com.
*You may register your product online at http//:www.fagorcommercial.com
This manual suits for next models
1
Table of contents
Other Fagor Refrigerator manuals

Fagor
Fagor FA16542 User manual

Fagor
Fagor EAFP-800 User manual

Fagor
Fagor FFJA4845 User manual

Fagor
Fagor FIS-820 User manual

Fagor
Fagor 3FFK-6745 User manual

Fagor
Fagor Ingenious User manual

Fagor
Fagor FA3702 User manual

Fagor
Fagor 3FFK-6836X User manual

Fagor
Fagor FFJA4845X User manual

Fagor
Fagor 3FFK-6645 User manual