1PARTS CHECK
1) MAKE SURE THE CORRECT MULLION IS BEING USED AND THE APPROPRIATE RIM DEVICES
ARE INSTALLED.
2) MAKE SURE ALL NEEDED PARTS ARE ON HAND.
3) REMOVE EXISTING MULLION AND TOP MULLION FITTING FROM DOOR OPENING.
NOTE: LIST DOES NOT REFLECT ALL POSSIBLE APPLICATIONS
1. CR UNIT 6. SCREW PACK
1/4”-20x3/4” UFPHMS
(4 QTY)
2. TOP MULLION FITTING ASSY.
3. TOP MULLION FITTING BASE
4. ADJUSTMENT SHIM
5. MORTISE CYLINDER
1-1/4” MORTISE CYLINDER
REQUIRED WITH STANDARD
“A” CAM (3/4” LONG, 5/16” WIDE)
NOTE: LONGER CYLINDERS
REQUIRE BLOCKING RINGS
SUPPLIED BY OTHERS
CYLINDER NUT
(1 QTY)
CYLINDER RETAINER
BRACKET (1 QTY)
1/4”-20x2” PPHMS
(4 QTY)
CRF-4023 AND CR-4023 MULLION RETROFIT KIT
INSTALLATION INSTRUCTIONS
PAGE 4
1. SCREW IN ADJUSTMENT SCREW ON THE TOP MULLION
5CYLINDER REMOVABLE MULLION
INSTALLATION
2. DROP BOTTOM OF MULLION ASSEMBLY OVER THE
ADJUSTMENT
SCREW
LOCATOR
PLUNGER
4. ONCE THE MULLION ASSEMBLY IS IN PLACE, SLIDE A SCREWDRIVER THRU THE SLOT ABOVE THE
TOP MULLION FITTING ASSEMBLY IN BY ONE-QUARTER TURN AND REPEAT.IF KEY STILL DOES NOT
FREELY TURN, REPEAT PROCESS UNTIL KEY FREELY TURNS AND MULLION ASSEMBLY CAN BE PULLED
FROM OPENING.
6. INSERT MULLION ASSEMBLY BACK INTO OPENING.
7. FINISH (PAINT) MULLION MAKING SURE TO MASK THE WARNING STICKER TO PREVENT PAINTING OVER IT.
5. TURN THE KEY IN THE CYLINDER. IF IT DOES NOT FREELY TURN, TURN THE ADJUSMENT SCREW IN THE
THE MULLION ASSEMBLY SHOULD LOCK IN
PLACE. IF NOT, REPEAT THE PROCESS UTILIZING
ADDITIONAL ADJUSTMENT SHIMS.
4) SWING THE MULLION ASSEMBLY BACK IN PLACE.
4
BOTTOM MULLION FITTING AND SWING MULLION
ASSEMBLY INTO PLACE. IF MULLION ASSEMBLY WILL
NOT SWING AND LOCK INTO PLACE, LOOK AT THE
LOCATION OF THE PLUNGER WITH RESPECT TO THE
LOCATOR ON THE CR UNIT.
FITTING ASSEMBLY AS FAR AS POSSIBLE.
A. IF THE PLUNGER IS ABOVE THE LOCATOR, THE
MULLION ASSEMBLY IS TOO SHORT.
1) SWING THE MULLION ASSEMBLY AWAY FROM
THE DOOR OPENING.
2) LOOSEN THE TOP MULLION FITTING ASSEMBLY
MOUNTING SCREWS ENOUGH TO SLIDE IN THE
ADJUSTMENT SHIM.
3) SLIDE THE ADJUSTMENT SHIM BETWEEN
THE FRAME AND THE TOP MULLION
FITTING BASE AND RE-TIGHTEN THE
MOUNTING SCREWS.
ADJUSTMENT SHIM
B. IF THE PLUNGER IS BELOW THE LOCATOR,
THE MULLION ASSEMBLY IS TOO LONG. RESIZE THE
MULLION ASSEMBLY PER SECTION , STEPS 3 AND 4.
3. TURN THE KEY IN THE CYLINDER AND PULL THE MULLION ASSEMBLY AWAY. RE-INSTALL MULLION
ASSEMBLY. REPEAT FOUR TO FIVE TIMES TO ENSURE PROPER FUNCTION.
CYLINDER AT THE TOP OF THE CR UNIT AND BACK THE ADJUSTMENT SCREW OUT OF THE TOP MULLION
FITTING ASSEMBLY UNTIL THE MULLION ASSEMBLY IS HELD TIGHT.
*D-4313*
D-4313
Customer Service
1-877-671-7011 www.allegion.com/us
© Allegion 2014
Printed in U.S.A.
D-4313 Rev. 01/14-b
PAGE 3
5. MARK MULLION AND CR UNIT ASSEMBLY ON ALL SIDES OF THE MULLION BODY TO THE MEASURMENT
2. USING CYLINDER NUT AND CYLINDER RETAINER BRACKET, INSTALL MORTISE CYLINDER IN CR UNIT.
IT MAY BE NECESSARY TO PUSH THE SPRING LOADED LOCKING PLATE IN THE CR UNIT UP TO SCREW ON
THE CYLINDER NUT. AFTER INSTALLING THE CYLINDER, INSERT AND TURN KEY TO CHECK FUNCTION OF
THE CR UNIT (SEE BELOW).
1/4”-20x3/4” UFPHMS
TOP OF DOOR STOP
FINISHED FLOOR
“X”
“X” = “Y” - 5/8”
RADIUS ON LOCKING
PLATE WILL MOVE UP
WHEN TURNING KEY
KEYWAY IS
UPSIDE DOWN
“Y” “Y”
3. ASSEMBLE THE CR UNIT TO THE MULLION WITH FOUR 1/4”-20x3/4” UFPHMS.
TAKEN IN STEP 5 MINUS 5/8”. THEN CUT THE
MULLION ASSEMBLY TO THE MARKED LENGTH.
4. MEASURE THE HEIGHT OF THE DOOR OPENING AS SHOWN BELOW AT THE CENTERLINE OF THE DOOR
OPENING. RECORD MEASUREMENT (“Y”) HERE: ____________
1. DOOR SHOULD BE FITTED AND HUNG INSIDE FRAME.
2. CHECK SQUARENESS OF FRAME AT CENTER OF OPENING WITH RESPECT TO THE DOORS. IF FRAME IS
NOT SQUARE, IT MAY BE NECESSARY TO SHIM THE TOP FITTING WITH SUITABLE SHIMS TO PROVIDE A
SQUARE FIT TO GET PROPER MULLION ENGAGEMENT.
3. MARK CENTERLINE OF OPENING ON TOP FRAME.
PAGE 2
OPENING C
L
2DOOR OPENING LAYOUT
1. MARK THE TOP OF THE FRAME PER THE DRILLING TEMPLATE FROM THE CENTER OF THIS BOOK.
CENTER PUNCH, DRILL AND TAP MARKED HOLES THRU BOTH FRAME SKIN AND REINFORCEMENT.
2. MOUNT TOP MULLION FITTING ASSEMBLY AND TOP MULLION FITTING BASE ON FRAME USING FOUR
1/4”-20x2” PPHMS.
TOP MULLION FITTING ASSEMBLY
TOP MULLION FITTING BASE
1/4”-20x2” PPHMS (4 QTY)
3MULLION FITTING INSTALLATION
C OPENING
L
DRILLING TEMPLATE
SQUARE
4MULLION PREPARATION
1. SLIDE CR UNIT OVER TOP OF EXISTING MULLION. USING THE CR UNIT AS A TEMPLATE, MARK THE
CENTER OF THE FOUR COUNTERSUNK HOLES. THEN REMOVE THE CR UNIT FROM THE MULLION. DRILL
AND TAP THE FOUR MARKED LOCATIONS FOR 1/4”-20 MACHINE SCREWS.
MARK, THEN DRILL AND TAP
FOR 1/4”-20 MACHINE SCREWS
0~1/8” GAP ALLOWABLE
EDGE OF DOOR STOP - FOLD HERE
EDGE OF DOOR STOP - FOLD HERE
1-3/8”
“A”
1-1/4”
DRILL #8 BIT (0.199”) THRU
FRAME AND REINFORCEMENT,
THEN TAP FOR 1/4”-20 MACHINE
SCREW
COPENING
L
L
TOP MULLION FITTING
ASSEMBLY DRILLING
TEMPLATE
C OPENING
“A” FOR STOP WITDHS
7/8” GREATER THAN 2-1/4”
1/2” LESS THAN 2-1/4”
CRF-4023 AND CR-4023
MULLION RETROFIT KIT
TOP MULLION FITTING ASSEMBLY DRILLING TEMPLATE

This manual suits for next models

1

Other Falcon Door Opening System manuals

Falcon 24-WDC User manual

Falcon

Falcon 24-WDC User manual

Falcon SC71 Series User manual

Falcon

Falcon SC71 Series User manual

Falcon SC81 User manual

Falcon

Falcon SC81 User manual

Falcon SC 71 SERIES User manual

Falcon

Falcon SC 71 SERIES User manual

Falcon RM70 User manual

Falcon

Falcon RM70 User manual

Falcon SC71 User manual

Falcon

Falcon SC71 User manual

Falcon 812L User manual

Falcon

Falcon 812L User manual

Falcon SC80 User manual

Falcon

Falcon SC80 User manual

Falcon 8230-3454 User manual

Falcon

Falcon 8230-3454 User manual

Falcon SC81 User manual

Falcon

Falcon SC81 User manual

Falcon SC60 Series User manual

Falcon

Falcon SC60 Series User manual

Falcon Ferme-Porte SC60 series User manual

Falcon

Falcon Ferme-Porte SC60 series User manual

Falcon SC 60 Series User manual

Falcon

Falcon SC 60 Series User manual

Popular Door Opening System manuals by other brands

Siegenia PremiDoor 76 Assembly instructions

Siegenia

Siegenia PremiDoor 76 Assembly instructions

Dormakaba UNIVERSAL GK 20 Mounting instructions

Dormakaba

Dormakaba UNIVERSAL GK 20 Mounting instructions

Horton C2150 Setup instructions

Horton

Horton C2150 Setup instructions

Eco FSA EFR TS-61 B Assembly instruction

Eco

Eco FSA EFR TS-61 B Assembly instruction

Dormakaba ES 200 user manual

Dormakaba

Dormakaba ES 200 user manual

Lamp MonoFlat FAD-5 instruction manual

Lamp

Lamp MonoFlat FAD-5 instruction manual

GATEXPERT GK-E Series user manual

GATEXPERT

GATEXPERT GK-E Series user manual

SAINT-GOBAIN Vetrotech LUNAX Conditions of Use

SAINT-GOBAIN

SAINT-GOBAIN Vetrotech LUNAX Conditions of Use

HAUTAU ATRIUM HS Mounting

HAUTAU

HAUTAU ATRIUM HS Mounting

Aritech ACA 001 Mounting instructions

Aritech

Aritech ACA 001 Mounting instructions

Viking C-3000 Technical practice

Viking

Viking C-3000 Technical practice

SECO-LARM SD-7175SGEX1Q manual

SECO-LARM

SECO-LARM SD-7175SGEX1Q manual

hager 4600 Series Installation instruction

hager

hager 4600 Series Installation instruction

Assa Abloy King 640 installation instructions

Assa Abloy

Assa Abloy King 640 installation instructions

Eco SR Assembly instructions

Eco

Eco SR Assembly instructions

Gliderol IGDU GEN II Upgrade Kit Install & user's guide

Gliderol

Gliderol IGDU GEN II Upgrade Kit Install & user's guide

Assa Abloy SARGENT 351 Series manual

Assa Abloy

Assa Abloy SARGENT 351 Series manual

CDVI DIGIWAY PLUS Instructions for installation, use and maintenance manual

CDVI

CDVI DIGIWAY PLUS Instructions for installation, use and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.