F&F RT-825 User manual

F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: biuro@fif.com.pl
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase.
Contact your dealer or directly with us.
More information how to make a com-
pliant can be found on the website:
www.fif.com.pl/reklamacje
Do not dispose of this device in the trash along with other waste! According
to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the
occasion of the purchase of new equipment (in accordance with the principle
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned
in nature, pose a threat to the environment and human health.
TEMPERATURE CONTROLLER RT-825
- 1 - - 2 -
Purpose Description of the external panel
Functioning
The RT-825 temperature controller is designed for direct control of
heating devices powered by 230 V with maximum current no higher
than 16 A.
The controller can operate in one of four operating modes:
- operation with an internal temperature sensor
- operation with an external temperature sensor (included)
- operation with two temperature sensors
- operation in "timer” mode
When the room temperature falls below 2°C from the temperature set
in the controller, the heating device switches on ( symbol on the
display). When the room temperature is higher than the set
temperature, the heating device will be disconnected. If the controller
operates in "0" mode, with two external and internal temperature
sensors (parameter F3) and the temperature in the room exceeds the
Programming
Press the MENU button to enter the programming mode. In the
programming mode you can set 8 parameters. Use the UP/DOWN
buttons to choose one of the parameters. Press ON/OFF button to
edit a parameter. Change the value of the parameter in the para-
meter edit mode using the UP/DOWN buttons. Confirm setting
with the ON/OFF button.
Parameters
F1 - set the time for automatic switching-on of the controller.
Minimum setting - 1 h.
F2 - set the time for automatic switching-off of the controller.
Minimum setting - 1 h
F3 - set the operating mode for the temperature sensors:
1 - operation with an internal temperature sensor
2 - operation with an external temperature sensor (included)
3 - operation with two temperature sensors (default setting)
F4 - set the time: week, hour, minute
F5 - set the upper threshold of the temperature protection in the
range of 40°C to 70°C with increments of 1°C (factory setting:
50°C). It works only in the mode of operation with two
temperature sensors.
F6 - set the antifreeze protection in the range of 2°C to 10°C with
increments of 1°C (factory setting: 3°C).
F7 - set temperature correction in case there is a difference
between temperature indication from the controller and
actual temperature in room. The correction can be adjusted
within ±5 °C with increments of 0.1 °C.
F8 - set the weekly program of temperature regulation in a room
according to the time of day and divided into working days,
Saturday and Sunday.
Set the weekly program of controller operation (F8)
Every day in the controller program is divided into four parts
marked with icons:
- morning
- forenoon (leaving the house)
- afternoon, evening (coming back)
- night
It is necessary to set the start time for each of these periods (the
hour of the end of the given period is the starting time of the next).
The start times for each time of the day should be set separately for
business days, Saturdays and Sundays. Temperature value is
programmed for each time of day.
The following weekly program of the controller operation is set:
5 9 0 8 3 1 2 5 9 2 6 2 4
MENU
88.8°C
ROOM outside
°C
88 88
ON
OFF
ON/OFF
UP
DOWN
time of day
indication
temperature
indicator
clock
indication of the
antifreeze mode
timer OFF/ON
indication
heating activation
indication
internal/external
probe
value set in parameter F5, the heating device will be discon-
nected. On the other hand, if the temperature falls below the
value set in parameter F6 (antifreeze mode), the heating device
will be switched on, whether the controller is on or off.
Timer mode operation
The "timer" function operates in a cyclic mode starting from
switching on the controller for the set time (parameter F1), and
then the controller will be switched off for the set time
(parameter F2) etc. on all days of the week. The activation time of
the controller starts when the number of hours is accepted with
the ON/OFF key. When the "timer" function is activated, the
temperature control is maintained depending on the settings.
" "
UP/DOWN button
Short press of the button during normal operation decreases or
increases the value of set temperature by one degree.
MENU button
Short press of the button switches the device to the programming
mode.
ON/OFF button
Long press of the button switches the controller on or off (about
2 seconds).
- 3 - - 4 -
Time of day Time of day
start
Value of the
set temperature
MON-FRI SAT, SUN
06:00 - 08:00
08:00 - 16:00
16:00 - 22:00
22:00 - 06:00
06:00
08:00
16:00
22:00
25
10
25
15
25
10
25
15

F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: biur[email protected]
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase.
Contact your dealer or directly with us.
More information how to make a com-
pliant can be found on the website:
www.fif.com.pl/reklamacje
Do not dispose of this device in the trash along with other waste! According
to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the
occasion of the purchase of new equipment (in accordance with the principle
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned
in nature, pose a threat to the environment and human health.
TEMPERATURE CONTROLLER RT-825
- 1 - - 2 -
Purpose Description of the external panel
Functioning
The RT-825 temperature controller is designed for direct control of
heating devices powered by 230 V with maximum current no higher
than 16 A.
The controller can operate in one of four operating modes:
- operation with an internal temperature sensor
- operation with an external temperature sensor (included)
- operation with two temperature sensors
- operation in "timer” mode
When the room temperature falls below 2°C from the temperature set
in the controller, the heating device switches on ( symbol on the
display). When the room temperature is higher than the set
temperature, the heating device will be disconnected. If the controller
operates in "0" mode, with two external and internal temperature
sensors (parameter F3) and the temperature in the room exceeds the
Programming
Press the MENU button to enter the programming mode. In the
programming mode you can set 8 parameters. Use the UP/DOWN
buttons to choose one of the parameters. Press ON/OFF button to
edit a parameter. Change the value of the parameter in the para-
meter edit mode using the UP/DOWN buttons. Confirm setting
with the ON/OFF button.
Parameters
F1 - set the time for automatic switching-on of the controller.
Minimum setting - 1 h.
F2 - set the time for automatic switching-off of the controller.
Minimum setting - 1 h
F3 - set the operating mode for the temperature sensors:
1 - operation with an internal temperature sensor
2 - operation with an external temperature sensor (included)
3 - operation with two temperature sensors (default setting)
F4 - set the time: week, hour, minute
F5 - set the upper threshold of the temperature protection in the
range of 40°C to 70°C with increments of 1°C (factory setting:
50°C). It works only in the mode of operation with two
temperature sensors.
F6 - set the antifreeze protection in the range of 2°C to 10°C with
increments of 1°C (factory setting: 3°C).
F7 - set temperature correction in case there is a difference
between temperature indication from the controller and
actual temperature in room. The correction can be adjusted
within ±5 °C with increments of 0.1 °C.
F8 - set the weekly program of temperature regulation in a room
according to the time of day and divided into working days,
Saturday and Sunday.
Set the weekly program of controller operation (F8)
Every day in the controller program is divided into four parts
marked with icons:
- morning
- forenoon (leaving the house)
- afternoon, evening (coming back)
- night
It is necessary to set the start time for each of these periods (the
hour of the end of the given period is the starting time of the next).
The start times for each time of the day should be set separately for
business days, Saturdays and Sundays. Temperature value is
programmed for each time of day.
The following weekly program of the controller operation is set:
5 9 0 8 3 1 2 5 9 2 6 2 4
MENU
88.8°C
ROOM outside
°C
88 88
ON
OFF
ON/OFF
UP
DOWN
time of day
indication
temperature
indicator
clock
indication of the
antifreeze mode
timer OFF/ON
indication
heating activation
indication
internal/external
probe
value set in parameter F5, the heating device will be discon-
nected. On the other hand, if the temperature falls below the
value set in parameter F6 (antifreeze mode), the heating device
will be switched on, whether the controller is on or off.
Timer mode operation
The "timer" function operates in a cyclic mode starting from
switching on the controller for the set time (parameter F1), and
then the controller will be switched off for the set time
(parameter F2) etc. on all days of the week. The activation time of
the controller starts when the number of hours is accepted with
the ON/OFF key. When the "timer" function is activated, the
temperature control is maintained depending on the settings.
" "
UP/DOWN button
Short press of the button during normal operation decreases or
increases the value of set temperature by one degree.
MENU button
Short press of the button switches the device to the programming
mode.
ON/OFF button
Long press of the button switches the controller on or off (about
2 seconds).
- 3 - - 4 -
Time of day Time of day
start
Value of the
set temperature
MON-FRI SAT, SUN
06:00 - 08:00
08:00 - 16:00
16:00 - 22:00
22:00 - 06:00
06:00
08:00
16:00
22:00
25
10
25
15
25
10
25
15

F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: biur[email protected]
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase.
Contact your dealer or directly with us.
More information how to make a com-
pliant can be found on the website:
www.fif.com.pl/reklamacje
Do not dispose of this device in the trash along with other waste! According
to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the
occasion of the purchase of new equipment (in accordance with the principle
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned
in nature, pose a threat to the environment and human health.
TEMPERATURE CONTROLLER RT-825
- 1 - - 2 -
Purpose Description of the external panel
Functioning
The RT-825 temperature controller is designed for direct control of
heating devices powered by 230 V with maximum current no higher
than 16 A.
The controller can operate in one of four operating modes:
- operation with an internal temperature sensor
- operation with an external temperature sensor (included)
- operation with two temperature sensors
- operation in "timer” mode
When the room temperature falls below 2°C from the temperature set
in the controller, the heating device switches on ( symbol on the
display). When the room temperature is higher than the set
temperature, the heating device will be disconnected. If the controller
operates in "0" mode, with two external and internal temperature
sensors (parameter F3) and the temperature in the room exceeds the
Programming
Press the MENU button to enter the programming mode. In the
programming mode you can set 8 parameters. Use the UP/DOWN
buttons to choose one of the parameters. Press ON/OFF button to
edit a parameter. Change the value of the parameter in the para-
meter edit mode using the UP/DOWN buttons. Confirm setting
with the ON/OFF button.
Parameters
F1 - set the time for automatic switching-on of the controller.
Minimum setting - 1 h.
F2 - set the time for automatic switching-off of the controller.
Minimum setting - 1 h
F3 - set the operating mode for the temperature sensors:
1 - operation with an internal temperature sensor
2 - operation with an external temperature sensor (included)
3 - operation with two temperature sensors (default setting)
F4 - set the time: week, hour, minute
F5 - set the upper threshold of the temperature protection in the
range of 40°C to 70°C with increments of 1°C (factory setting:
50°C). It works only in the mode of operation with two
temperature sensors.
F6 - set the antifreeze protection in the range of 2°C to 10°C with
increments of 1°C (factory setting: 3°C).
F7 - set temperature correction in case there is a difference
between temperature indication from the controller and
actual temperature in room. The correction can be adjusted
within ±5 °C with increments of 0.1 °C.
F8 - set the weekly program of temperature regulation in a room
according to the time of day and divided into working days,
Saturday and Sunday.
Set the weekly program of controller operation (F8)
Every day in the controller program is divided into four parts
marked with icons:
- morning
- forenoon (leaving the house)
- afternoon, evening (coming back)
- night
It is necessary to set the start time for each of these periods (the
hour of the end of the given period is the starting time of the next).
The start times for each time of the day should be set separately for
business days, Saturdays and Sundays. Temperature value is
programmed for each time of day.
The following weekly program of the controller operation is set:
5 9 0 8 3 1 2 5 9 2 6 2 4
MENU
88.8°C
ROOM outside
°C
88 88
ON
OFF
ON/OFF
UP
DOWN
time of day
indication
temperature
indicator
clock
indication of the
antifreeze mode
timer OFF/ON
indication
heating activation
indication
internal/external
probe
value set in parameter F5, the heating device will be discon-
nected. On the other hand, if the temperature falls below the
value set in parameter F6 (antifreeze mode), the heating device
will be switched on, whether the controller is on or off.
Timer mode operation
The "timer" function operates in a cyclic mode starting from
switching on the controller for the set time (parameter F1), and
then the controller will be switched off for the set time
(parameter F2) etc. on all days of the week. The activation time of
the controller starts when the number of hours is accepted with
the ON/OFF key. When the "timer" function is activated, the
temperature control is maintained depending on the settings.
" "
UP/DOWN button
Short press of the button during normal operation decreases or
increases the value of set temperature by one degree.
MENU button
Short press of the button switches the device to the programming
mode.
ON/OFF button
Long press of the button switches the controller on or off (about
2 seconds).
- 3 - - 4 -
Time of day Time of day
start
Value of the
set temperature
MON-FRI SAT, SUN
06:00 - 08:00
08:00 - 16:00
16:00 - 22:00
22:00 - 06:00
06:00
08:00
16:00
22:00
25
10
25
15
25
10
25
15

F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: biur[email protected]
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase.
Contact your dealer or directly with us.
More information how to make a com-
pliant can be found on the website:
www.fif.com.pl/reklamacje
Do not dispose of this device in the trash along with other waste! According
to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the
occasion of the purchase of new equipment (in accordance with the principle
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned
in nature, pose a threat to the environment and human health.
TEMPERATURE CONTROLLER RT-825
- 1 - - 2 -
Purpose Description of the external panel
Functioning
The RT-825 temperature controller is designed for direct control of
heating devices powered by 230 V with maximum current no higher
than 16 A.
The controller can operate in one of four operating modes:
- operation with an internal temperature sensor
- operation with an external temperature sensor (included)
- operation with two temperature sensors
- operation in "timer” mode
When the room temperature falls below 2°C from the temperature set
in the controller, the heating device switches on ( symbol on the
display). When the room temperature is higher than the set
temperature, the heating device will be disconnected. If the controller
operates in "0" mode, with two external and internal temperature
sensors (parameter F3) and the temperature in the room exceeds the
Programming
Press the MENU button to enter the programming mode. In the
programming mode you can set 8 parameters. Use the UP/DOWN
buttons to choose one of the parameters. Press ON/OFF button to
edit a parameter. Change the value of the parameter in the para-
meter edit mode using the UP/DOWN buttons. Confirm setting
with the ON/OFF button.
Parameters
F1 - set the time for automatic switching-on of the controller.
Minimum setting - 1 h.
F2 - set the time for automatic switching-off of the controller.
Minimum setting - 1 h
F3 - set the operating mode for the temperature sensors:
1 - operation with an internal temperature sensor
2 - operation with an external temperature sensor (included)
3 - operation with two temperature sensors (default setting)
F4 - set the time: week, hour, minute
F5 - set the upper threshold of the temperature protection in the
range of 40°C to 70°C with increments of 1°C (factory setting:
50°C). It works only in the mode of operation with two
temperature sensors.
F6 - set the antifreeze protection in the range of 2°C to 10°C with
increments of 1°C (factory setting: 3°C).
F7 - set temperature correction in case there is a difference
between temperature indication from the controller and
actual temperature in room. The correction can be adjusted
within ±5 °C with increments of 0.1 °C.
F8 - set the weekly program of temperature regulation in a room
according to the time of day and divided into working days,
Saturday and Sunday.
Set the weekly program of controller operation (F8)
Every day in the controller program is divided into four parts
marked with icons:
- morning
- forenoon (leaving the house)
- afternoon, evening (coming back)
- night
It is necessary to set the start time for each of these periods (the
hour of the end of the given period is the starting time of the next).
The start times for each time of the day should be set separately for
business days, Saturdays and Sundays. Temperature value is
programmed for each time of day.
The following weekly program of the controller operation is set:
5 9 0 8 3 1 2 5 9 2 6 2 4
MENU
88.8°C
ROOM outside
°C
88 88
ON
OFF
ON/OFF
UP
DOWN
time of day
indication
temperature
indicator
clock
indication of the
antifreeze mode
timer OFF/ON
indication
heating activation
indication
internal/external
probe
value set in parameter F5, the heating device will be discon-
nected. On the other hand, if the temperature falls below the
value set in parameter F6 (antifreeze mode), the heating device
will be switched on, whether the controller is on or off.
Timer mode operation
The "timer" function operates in a cyclic mode starting from
switching on the controller for the set time (parameter F1), and
then the controller will be switched off for the set time
(parameter F2) etc. on all days of the week. The activation time of
the controller starts when the number of hours is accepted with
the ON/OFF key. When the "timer" function is activated, the
temperature control is maintained depending on the settings.
" "
UP/DOWN button
Short press of the button during normal operation decreases or
increases the value of set temperature by one degree.
MENU button
Short press of the button switches the device to the programming
mode.
ON/OFF button
Long press of the button switches the controller on or off (about
2 seconds).
- 3 - - 4 -
Time of day Time of day
start
Value of the
set temperature
MON-FRI SAT, SUN
06:00 - 08:00
08:00 - 16:00
16:00 - 22:00
22:00 - 06:00
06:00
08:00
16:00
22:00
25
10
25
15
25
10
25
15

- 6 -
Controller reset
Keep the UP button pressed for a controller to reset itself and dis-
connect heating device.
Press the ON/OFF button to return to operation.
Protection
To protect the controller from unauthorized access, press the
UP/DOWN button for a longer time.
Activation of the protection is signaled by a padlock symbol on the
display. Unlocking is done in the same way.
Automatic/manual operation
Longer press of the DOWN button changes the controller mode of
operation from automatic to manual and vice versa (day time icon
goes off).
Manual operation - room temperature control is based on the cur-
rent setting. Use the UP/DOWN buttons to change the temperature.
Automatic operation - the temperature is maintained on the basis of
the pre-programmed cycles of the controller.
Temperature readout
If the controller is set to operate with two temperature sensors by
short press of the ON/OFF button, the readout source changes from
the internal sensor to the external.
Controller operation errors indication
Er1 - damage to internal temperature probe
Er2 - damage of external temperature probe
Er3 - damage to internal and external probe
- 8 -
D161220
Technical data
power supply 230 V AC
current load heating circuit <16 A
temperature adjustment range 5÷55°C
histeresis 2°C
setting accuracy 1°C
measurement accuracy ±0,1°C
power consumption 1 W
working temperature 0÷65°C
terminal 2.5mm² screw terminals
dimensions
front 86×86 mm; D= 22 mm
back 6 27.5 mm
mounting
external temperature sensor NTC
sensor dimensions Ø7
Ø 0; D=
in flush mounted
ingress protection IP20
Ø60
; h=25 mm
sensor isolation PC muff
wire PC 2×0,34 mm²; l= 3 m
3. Remove the cover and the frame of the controller, taking care not
to damage the electronics of the controller.
4. Connect according to the scheme.
5. Place the bottom part of the controller in the flush-mounted box
and fix it with the screws.
6. Put the frame back on and press the cover.
- 7 -
Mounting
1. Disconnect the power supply from the cir-
cuit to which the controller will be con-
nected.
2. Using a narrow, flat-blade driver, gently
press the catch (marked with the arrow on
the drawing) to lock the controller
housing.
Connection scheme
probe
NL
1 2 3456
OUT N
heater
1/4 - output for heater connection
2 - L power supply of the controller
3 - N power supply of the controller
5/6 - output for temperature probe connection
Take special care when installing the controller. Incorrect
connection may result in electric shock and/or damage to
the controller and the powered device.
Do not install a device that is damaged or incomplete.
Do not install the device in rooms with high humidity, such
as bathrooms.
Setting up a weekly operation program:
1. Press the MENU button to enter the programming mode.
2. Use the UP/DOWN buttons to select parameter F8 and confirm
with the ON/OFF button.
3. Use the UP/DOWN button to select the day of the week: MON-
FRI, Saturday or Sunday (SAT, SUN).
Example: Select MON-FRI and confirm with the ON / OFF button.
4. Use the UP / DOWN buttons to select the time of day.
Example: Select in the morning, confirm with the ON/OFF button.
5. Use the UP/DOWN buttons to set the start time of the "morning"
time of day.
Example: Select 06:00 (change with increments of 15 minutes),
confirm with ON/OFF button.
WARNING! The start time of the next period is the end of the
previous one, so there is no option to set the ending time of the
given period).
6. Use the UP/DOWN buttons to set the desired temperature for
this time of day - morning. The temperature can be changed
every 1 °C in the range of 5÷55 °C. Confirm with the ON/OFF
button.
7. Once the temperature value has been confirmed, the program
automatically returns to step 4, allowing to set the parameters of
the next time of day.
8. After setting the start times and temperature values, the
program will automatically switch to setting the time for
Saturday, and then for Sunday. After entering the last parameter
for Sunday and confirming it with the ON/OFF button, the
program will return to the selection of parameters F1÷F8.
9. To exit the programming mode press the MENU button or wait 5
seconds and then the controller automatically returns to normal
operation.
- 5 -

- 6 -
Controller reset
Keep the UP button pressed for a controller to reset itself and dis-
connect heating device.
Press the ON/OFF button to return to operation.
Protection
To protect the controller from unauthorized access, press the
UP/DOWN button for a longer time.
Activation of the protection is signaled by a padlock symbol on the
display. Unlocking is done in the same way.
Automatic/manual operation
Longer press of the DOWN button changes the controller mode of
operation from automatic to manual and vice versa (day time icon
goes off).
Manual operation - room temperature control is based on the cur-
rent setting. Use the UP/DOWN buttons to change the temperature.
Automatic operation - the temperature is maintained on the basis of
the pre-programmed cycles of the controller.
Temperature readout
If the controller is set to operate with two temperature sensors by
short press of the ON/OFF button, the readout source changes from
the internal sensor to the external.
Controller operation errors indication
Er1 - damage to internal temperature probe
Er2 - damage of external temperature probe
Er3 - damage to internal and external probe
- 8 -
D161220
Technical data
power supply 230 V AC
current load heating circuit <16 A
temperature adjustment range 5÷55°C
histeresis 2°C
setting accuracy 1°C
measurement accuracy ±0,1°C
power consumption 1 W
working temperature 0÷65°C
terminal 2.5mm² screw terminals
dimensions
front 86×86 mm; D= 22 mm
back 6 27.5 mm
mounting
external temperature sensor NTC
sensor dimensions Ø7
Ø 0; D=
in flush mounted
ingress protection IP20
Ø60
; h=25 mm
sensor isolation PC muff
wire PC 2×0,34 mm²; l= 3 m
3. Remove the cover and the frame of the controller, taking care not
to damage the electronics of the controller.
4. Connect according to the scheme.
5. Place the bottom part of the controller in the flush-mounted box
and fix it with the screws.
6. Put the frame back on and press the cover.
- 7 -
Mounting
1. Disconnect the power supply from the cir-
cuit to which the controller will be con-
nected.
2. Using a narrow, flat-blade driver, gently
press the catch (marked with the arrow on
the drawing) to lock the controller
housing.
Connection scheme
probe
NL
1 2 3456
OUT N
heater
1/4 - output for heater connection
2 - L power supply of the controller
3 - N power supply of the controller
5/6 - output for temperature probe connection
Take special care when installing the controller. Incorrect
connection may result in electric shock and/or damage to
the controller and the powered device.
Do not install a device that is damaged or incomplete.
Do not install the device in rooms with high humidity, such
as bathrooms.
Setting up a weekly operation program:
1. Press the MENU button to enter the programming mode.
2. Use the UP/DOWN buttons to select parameter F8 and confirm
with the ON/OFF button.
3. Use the UP/DOWN button to select the day of the week: MON-
FRI, Saturday or Sunday (SAT, SUN).
Example: Select MON-FRI and confirm with the ON / OFF button.
4. Use the UP / DOWN buttons to select the time of day.
Example: Select in the morning, confirm with the ON/OFF button.
5. Use the UP/DOWN buttons to set the start time of the "morning"
time of day.
Example: Select 06:00 (change with increments of 15 minutes),
confirm with ON/OFF button.
WARNING! The start time of the next period is the end of the
previous one, so there is no option to set the ending time of the
given period).
6. Use the UP/DOWN buttons to set the desired temperature for
this time of day - morning. The temperature can be changed
every 1 °C in the range of 5÷55 °C. Confirm with the ON/OFF
button.
7. Once the temperature value has been confirmed, the program
automatically returns to step 4, allowing to set the parameters of
the next time of day.
8. After setting the start times and temperature values, the
program will automatically switch to setting the time for
Saturday, and then for Sunday. After entering the last parameter
for Sunday and confirming it with the ON/OFF button, the
program will return to the selection of parameters F1÷F8.
9. To exit the programming mode press the MENU button or wait 5
seconds and then the controller automatically returns to normal
operation.
- 5 -

- 6 -
Controller reset
Keep the UP button pressed for a controller to reset itself and dis-
connect heating device.
Press the ON/OFF button to return to operation.
Protection
To protect the controller from unauthorized access, press the
UP/DOWN button for a longer time.
Activation of the protection is signaled by a padlock symbol on the
display. Unlocking is done in the same way.
Automatic/manual operation
Longer press of the DOWN button changes the controller mode of
operation from automatic to manual and vice versa (day time icon
goes off).
Manual operation - room temperature control is based on the cur-
rent setting. Use the UP/DOWN buttons to change the temperature.
Automatic operation - the temperature is maintained on the basis of
the pre-programmed cycles of the controller.
Temperature readout
If the controller is set to operate with two temperature sensors by
short press of the ON/OFF button, the readout source changes from
the internal sensor to the external.
Controller operation errors indication
Er1 - damage to internal temperature probe
Er2 - damage of external temperature probe
Er3 - damage to internal and external probe
- 8 -
D161220
Technical data
power supply 230 V AC
current load heating circuit <16 A
temperature adjustment range 5÷55°C
histeresis 2°C
setting accuracy 1°C
measurement accuracy ±0,1°C
power consumption 1 W
working temperature 0÷65°C
terminal 2.5mm² screw terminals
dimensions
front 86×86 mm; D= 22 mm
back 6 27.5 mm
mounting
external temperature sensor NTC
sensor dimensions Ø7
Ø 0; D=
in flush mounted
ingress protection IP20
Ø60
; h=25 mm
sensor isolation PC muff
wire PC 2×0,34 mm²; l= 3 m
3. Remove the cover and the frame of the controller, taking care not
to damage the electronics of the controller.
4. Connect according to the scheme.
5. Place the bottom part of the controller in the flush-mounted box
and fix it with the screws.
6. Put the frame back on and press the cover.
- 7 -
Mounting
1. Disconnect the power supply from the cir-
cuit to which the controller will be con-
nected.
2. Using a narrow, flat-blade driver, gently
press the catch (marked with the arrow on
the drawing) to lock the controller
housing.
Connection scheme
probe
NL
1 2 3456
OUT N
heater
1/4 - output for heater connection
2 - L power supply of the controller
3 - N power supply of the controller
5/6 - output for temperature probe connection
Take special care when installing the controller. Incorrect
connection may result in electric shock and/or damage to
the controller and the powered device.
Do not install a device that is damaged or incomplete.
Do not install the device in rooms with high humidity, such
as bathrooms.
Setting up a weekly operation program:
1. Press the MENU button to enter the programming mode.
2. Use the UP/DOWN buttons to select parameter F8 and confirm
with the ON/OFF button.
3. Use the UP/DOWN button to select the day of the week: MON-
FRI, Saturday or Sunday (SAT, SUN).
Example: Select MON-FRI and confirm with the ON / OFF button.
4. Use the UP / DOWN buttons to select the time of day.
Example: Select in the morning, confirm with the ON/OFF button.
5. Use the UP/DOWN buttons to set the start time of the "morning"
time of day.
Example: Select 06:00 (change with increments of 15 minutes),
confirm with ON/OFF button.
WARNING! The start time of the next period is the end of the
previous one, so there is no option to set the ending time of the
given period).
6. Use the UP/DOWN buttons to set the desired temperature for
this time of day - morning. The temperature can be changed
every 1 °C in the range of 5÷55 °C. Confirm with the ON/OFF
button.
7. Once the temperature value has been confirmed, the program
automatically returns to step 4, allowing to set the parameters of
the next time of day.
8. After setting the start times and temperature values, the
program will automatically switch to setting the time for
Saturday, and then for Sunday. After entering the last parameter
for Sunday and confirming it with the ON/OFF button, the
program will return to the selection of parameters F1÷F8.
9. To exit the programming mode press the MENU button or wait 5
seconds and then the controller automatically returns to normal
operation.
- 5 -

- 6 -
Controller reset
Keep the UP button pressed for a controller to reset itself and dis-
connect heating device.
Press the ON/OFF button to return to operation.
Protection
To protect the controller from unauthorized access, press the
UP/DOWN button for a longer time.
Activation of the protection is signaled by a padlock symbol on the
display. Unlocking is done in the same way.
Automatic/manual operation
Longer press of the DOWN button changes the controller mode of
operation from automatic to manual and vice versa (day time icon
goes off).
Manual operation - room temperature control is based on the cur-
rent setting. Use the UP/DOWN buttons to change the temperature.
Automatic operation - the temperature is maintained on the basis of
the pre-programmed cycles of the controller.
Temperature readout
If the controller is set to operate with two temperature sensors by
short press of the ON/OFF button, the readout source changes from
the internal sensor to the external.
Controller operation errors indication
Er1 - damage to internal temperature probe
Er2 - damage of external temperature probe
Er3 - damage to internal and external probe
- 8 -
D161220
Technical data
power supply 230 V AC
current load heating circuit <16 A
temperature adjustment range 5÷55°C
histeresis 2°C
setting accuracy 1°C
measurement accuracy ±0,1°C
power consumption 1 W
working temperature 0÷65°C
terminal 2.5mm² screw terminals
dimensions
front 86×86 mm; D= 22 mm
back 6 27.5 mm
mounting
external temperature sensor NTC
sensor dimensions Ø7
Ø 0; D=
in flush mounted
ingress protection IP20
Ø60
; h=25 mm
sensor isolation PC muff
wire PC 2×0,34 mm²; l= 3 m
3. Remove the cover and the frame of the controller, taking care not
to damage the electronics of the controller.
4. Connect according to the scheme.
5. Place the bottom part of the controller in the flush-mounted box
and fix it with the screws.
6. Put the frame back on and press the cover.
- 7 -
Mounting
1. Disconnect the power supply from the cir-
cuit to which the controller will be con-
nected.
2. Using a narrow, flat-blade driver, gently
press the catch (marked with the arrow on
the drawing) to lock the controller
housing.
Connection scheme
probe
NL
1 2 3456
OUT N
heater
1/4 - output for heater connection
2 - L power supply of the controller
3 - N power supply of the controller
5/6 - output for temperature probe connection
Take special care when installing the controller. Incorrect
connection may result in electric shock and/or damage to
the controller and the powered device.
Do not install a device that is damaged or incomplete.
Do not install the device in rooms with high humidity, such
as bathrooms.
Setting up a weekly operation program:
1. Press the MENU button to enter the programming mode.
2. Use the UP/DOWN buttons to select parameter F8 and confirm
with the ON/OFF button.
3. Use the UP/DOWN button to select the day of the week: MON-
FRI, Saturday or Sunday (SAT, SUN).
Example: Select MON-FRI and confirm with the ON / OFF button.
4. Use the UP / DOWN buttons to select the time of day.
Example: Select in the morning, confirm with the ON/OFF button.
5. Use the UP/DOWN buttons to set the start time of the "morning"
time of day.
Example: Select 06:00 (change with increments of 15 minutes),
confirm with ON/OFF button.
WARNING! The start time of the next period is the end of the
previous one, so there is no option to set the ending time of the
given period).
6. Use the UP/DOWN buttons to set the desired temperature for
this time of day - morning. The temperature can be changed
every 1 °C in the range of 5÷55 °C. Confirm with the ON/OFF
button.
7. Once the temperature value has been confirmed, the program
automatically returns to step 4, allowing to set the parameters of
the next time of day.
8. After setting the start times and temperature values, the
program will automatically switch to setting the time for
Saturday, and then for Sunday. After entering the last parameter
for Sunday and confirming it with the ON/OFF button, the
program will return to the selection of parameters F1÷F8.
9. To exit the programming mode press the MENU button or wait 5
seconds and then the controller automatically returns to normal
operation.
- 5 -
Table of contents
Popular Temperature Controllers manuals by other brands

Process Technology
Process Technology DQ15D instruction manual

STORK TRONIC
STORK TRONIC ST48-WHDVM.04 manual

Ropex
Ropex RESISTRON RES-406 operating instructions

AUTOMATE SCIENTIFIC
AUTOMATE SCIENTIFIC ThermoClamp-3 user manual

Lennox
Lennox Basic Climatic Controller Ecologic manual

LP-RESEARCH
LP-RESEARCH LPMS-B2 manual