P/N: 01402-001 ∙ Rev. 09.18
© 2018 Farpointe Data, Inc. All rights reserved. Farpointe Data®, Pyramid
Series Proximity®, Delta®, and Ranger®are the registered U.S. trademarks of
Farpointe Data, Inc. Conekt is a trademark of Farpointe Data, Inc. All other
trademarks are the property of their respective owners.
8.0 Voltage
8 to 14 VDC. 12 VDC at the reader is recommended for best operation.
9.0 Read Mode
For sector (access control) reads, pull the purple conductor low.
10.0 Connection
Connection must be done in accordance with NFPA 70. Do not connect to a receptacle controlled by a switch. Connect to a power limited DC
voltage source.
11.0 Troubleshooting
1. When the reader is first powered on it will beep 4-times, and the LED will shine red.
2. Presenting a supported access credential will result in the reader beeping and the LED flashing once.
3. Mobile operation is optimized for smartphones supporting Bluetooth LE version 4.2. Further, for the downloading of mobile access credentials,
a stable, high-quality internet connection is recommended.
NOTE: The access panel controls LED functionality, such as switching the LED to green.
If the reader does not recognize the mobile credential or card or tag (no beep, no LED flash) or exhibits short read range, please see the table
below for possible causes and solutions.
Possible Cause Corrective Action
Incorrect cabling Verify gauge, connections and cabling length
Not enough power 12 VDC recommended
Incorrect credential used Verify if credential technology is supported
Reader/access panel not properly grounded Earth ground needed—verify shield and reader ground are tied at access panel and connect
to ground at one point
Supply generating interference Linear power supply recommended, verify switching power supply before use
Should any of the corrective actions mentioned above not improve performance, disconnect the reader from the access panel and power it with a separate power supply or 9VDC
battery, and re-test card functionality. By powering the readers separately, most variables that may lead to reduced performance can be eliminated. Should the problem persist,
please contact Farpointe directly. Many Farpointe Data Readers carry the following certifications:
FCC Compliance Statement: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interfer-ence, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequen-cy energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be re-quired to correct the interference at his own expense.
IMPORTANT! Changes or modifications not expressly approved by Farpointe Data, Inc. could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause unde-sired operation of the device.
Cet appareil est conforme à Industrie Canada exempts de licence standard RSS (s) . Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas
provoquer d’interférences et (2) ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
Product can be used without license conditions or restrictions in all European Union coun-tries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxem-bourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain, Sweden, United
Kingdom, as well as other non-EU countries, including Iceland, Norway, and Switzerland.
Farpointe Data reserves the right to change specifications without notice.
QUICK START GUIDE
CONEKT™MOBILE-READY
CONTACTLESS SMARTCARD READER
Farpointe Data, Inc.
1376 Borregas Avenue
Sunnyvale, CA 94089-1004 USA
Office: +1-408-731-8700
Fax: +1-408-731-8705
www.farpointedata.com