faucet strommen 30574 User manual

Suits Models:
30574, 33718, 33850, 30660, 30661, 30662, 33706, 33822, 33823, 33848, 33713,
33842, 33843, 35134, 35135
Important requirements:
Cleaning
Clean only with a soft microfiber or similar cloth and warm clean water. Ensure that
the cloth is clean and free of any grit or chemical. Dry tap o with a soft clean cloth.
Ensure that your tap is not subject to any chemicals, building grit or any type of
abrasive of polish. For care of special finishes please visit our website.
Maintenance
Aerators may need to be flushed from time to time if flow diminishes or stream
pattern deteriorates. For Pegasi & Cascade mixers, use the aerator key provided
to unscrew the aerator. You will notice a “castle” pattern around the edge of the
aerator, the key engages with this allowing you to unscrew the insert easily. For Zeos
models, use the aerator key to unscrew the aerator housing, you will then be able to
pop the insert out the top of the housing. Rinse o the upper face of the insert with
running water and gently brush clean with an old toothbrush to remove any debris
before refitting the aerator.
Installation Guide IG 007
Floor Mixers
Products Warranty – Australia
Faucet Australia Pty Limited (ABN 83 683 523 321) warrants its products to the original owner as per the periods in the table below. This
Warranty applies to all product purchased on or after 24 Oct 2017. Our liability under this warranty is limited at our option to the repair or
replacement of the defective product or part, the cost of repair of the defective product or part or the supply of an equivalent product or part,
in each case if we are satisfied the loss or damage was due to a defect in the materials or workmanship of the product or part.
Note: “Residential” refers to normal residential domestic purposes including houses and residential apartments. “Commercial;” refers to all
non-residential purposes including Hotels, Schools, Care homes, Hospitals, clubs etc.
Exceptions
Defects caused by improper use, improper installation, surface damage caused by installation, improper care of the product or failure to
observe any one or more of the following will not be covered by this Warranty:
1. Applicable Health Acts;
2. Installation in accordance with manufacturer’s instructions and specifications (Note: Tapware, mixers and filters must be installed
by qualified plumber);
3. All products to be cleaned with only warm water and a soft clean cloth
4. Tapware and showers to be supplied with only clean potable water
5. Tapware and showers to be subject to no more than 700kpa whether during use or during site testing, and site must be fitted with
500kpa mains pressure limiting valve.
6. Tapware and showers to be subject to water temperatures no hotter than 65 degrees Celsius
7. Tapware and showers to be installed in accordance with AS/NZS 3500 and other standards which govern the water supply and
sewerage plumbing requirements at the location of installation.
Limitations
8. Warranty does not cover fair wear and tear on sealing rings and washers. Depending on usage and conditions these may have to be
replaced within the Warranty period;
9. For finishes, this warranty does not cover damage caused by use of chemicals or detergents or abrasives and is limited to coating
failure by bubbling, cracking or flaking. Note that Organic finishes are expected to change colour, develop patina and verdigris.
10. Does not cover any loss or damage sustained by the consumer (including consequential loss or damage), in respect of the product
or failure or omission on the part of Faucet Australia to comply with its obligations under these conditions.
11. For Baths & Basins, The warranty does not cover damage caused by exposure to direct sunlight or UV, exposure to temperatures
over 60 degrees Celsius, damage caused by dropping sharp or heavy objects.
12. For Baths and basins this warranty does not cover damage caused by Strong Chlorinated solvents, Chloroform, Chlorobenzene,
Nail polish remover, Methylene Chloride, Acetone, Turpentine, Ethyl Acetate, Acids, Ketones, Phenols, Ethers, Drain Cleaner, Toilet
Cleaner, Salts, Oils, Milks and bathwater additives, non-approved liquids or Chemicals.
Lodging a claim
Claims must be lodged immediately or within 3 days of detection. Proof and Date of purchase from a Faucet Strommen dealer along with
site details and contacts will be required to process a claim. All claims must be lodged with Faucet Australia via one of these methods:
Phone: 03 5450 4236
Email: [email protected]om.au
Mail: PO Box 271 Kerang VIC 3579
Your costs in making a claim under this warranty, including all freight, collection and delivery costs are to be borne and paid by you. We also
reserve the right at our cost to inspect any alleged defect in the product wherever it is located or installed or on our premises.
Other Conditions
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or
refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Faucet Australia Pty Ltd 24 Oct 2017
Product Category Residential Warranty Period Commercial Warranty Period
Tapware, Showers, Accessories 5 Years parts & labour + 10 years parts 2 Years parts & labour + 3 years parts
Intro Tapware 1 Year parts & labour + 4 years parts 1 Year parts & labour
Silkstone Baths & Basins Lifetime 2 Years parts & labour
Special Finishes 5 Years parts & labour 2 Years parts & labour
Faucet Australia Pty Ltd ABN 83683523321 31 Tate Drive, Kerang VIC 3579
www.faucetstrommen.com.au P: +61 3 5450 4236 [email protected]u
Must be fitted in
accordance with
AS/NZS 3500
by qualified
plumber
Mains
500kpa
regulator
must be
fitted
Maximum hot
water temp.
65°C
Only clean
municiple water
supply. No bore,
dam or hard water
without filtration
& treatment
Release Date: 09.12.20
Rough in Installation
1. Unpack the Mixer body assembly (leave the black plastic protector cover in
place), note the Hot and cold inlet ports. Plumb the mains water supply to the
body and pressure test.
2. Set the body into the floor. Take special note of floor inset depth of 46 - 50 mm
below finished tiles surface.
3. Mount body level (final leveling can be done at fit o in the foot of the mixer)
4. Orientation is not important as the fit o allows full 360 degree orientation
adjustment.
5. Fasten the body using suitable anchors.
6. Fill area around body with cement to floor level in concrete installations
7. Ensure that the tiler cuts the tiles close around the mixer so that the 90mm cover
plate covers the hole.
Fit O Installation
1. Carefully slide the cover plate over the base of the mixer keeping it aligned
so that it does not jamb and mark the mixer pole.
2. Unpack the stainless steel foot and screw the 3 leveling grub screws into the
foot such that they do not protrude out the bottom
3. Fasten the foot onto the bottom of the mixer firmly hand tight. Do not cross
thread.
4. Remove the black plastic protector cover from the mixer body in the floor (you
may need to cut the grout/tile glue around the edge to prize it free
5. Remove any grit, glue or cement from the face of the mixer body
6. With the mains water switched o, remover the 2 temporary water plugs from
the mixer body
7. Place the thin stainless base washer over the mixer body
8. Place a red fiber washer into each connection recess
9. Bring the mixer into position over the body in the floor and, by hand, screw the
hose ends into the mixer body. (be careful to pick up the thread straight to
prevent cross threading)
10. Fasten in the hoses firmly using a small spanner
11. Stand the mixer up in place and rotate it to the desired position
12. Rotate the stainless washer to permit the 3 fastening screws to protrude through
the washer and fasten into the body in the floor
13. Before tightening the foot down set the exact rotation and use the grub screws
in the foot to level the mixer
14. For models with gooseneck spout you may need to attached spout to the body
as it is supplied un-assembled. To do this note the brass rotator ring on the spout
assembly. This ring features an indent hole. Carefully align this hole with the grub
screw mount hole in the back of the mixer. Insert the spout into the mixer and fasten
with grub screw. Once fitted check proper attachment by pulling spout and ensuring
it does not come out.
15. Open the tap handle and slowly open the mains water supply
16. Check the tap operation and check there are no leaks from the fittings
1 7. Slide the flange down over the fittings

This manual suits for next models

14

Other faucet strommen Plumbing Product manuals

faucet strommen 30908 User manual

faucet strommen

faucet strommen 30908 User manual

faucet strommen 36015 User manual

faucet strommen

faucet strommen 36015 User manual

faucet strommen 30401 User manual

faucet strommen

faucet strommen 30401 User manual

faucet strommen IG 020 User manual

faucet strommen

faucet strommen IG 020 User manual

faucet strommen 30573 User manual

faucet strommen

faucet strommen 30573 User manual

faucet strommen IG 033 User manual

faucet strommen

faucet strommen IG 033 User manual

faucet strommen 30560 User manual

faucet strommen

faucet strommen 30560 User manual

faucet strommen 30909 User manual

faucet strommen

faucet strommen 30909 User manual

faucet strommen 34351 User manual

faucet strommen

faucet strommen 34351 User manual

faucet strommen 30571 User manual

faucet strommen

faucet strommen 30571 User manual

faucet strommen 34410 User manual

faucet strommen

faucet strommen 34410 User manual

faucet strommen IG 021 User manual

faucet strommen

faucet strommen IG 021 User manual

Popular Plumbing Product manuals by other brands

Toto TX402S quick start guide

Toto

Toto TX402S quick start guide

flamco Flamcovent Clean Installation and operating instructions

flamco

flamco Flamcovent Clean Installation and operating instructions

Spectrum Brands Pfister Vaneri LF-048-VRI Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Vaneri LF-048-VRI Quick installation guide

STROMBERG CELSIUS OVAL Assembly & Operating Instruction

STROMBERG

STROMBERG CELSIUS OVAL Assembly & Operating Instruction

Kohler K-72218 Installation and care guide

Kohler

Kohler K-72218 Installation and care guide

BELLOSTA BRUSIN 5709/1 installation instructions

BELLOSTA

BELLOSTA BRUSIN 5709/1 installation instructions

Kohler Revival K-2950-1/8 installation instructions

Kohler

Kohler Revival K-2950-1/8 installation instructions

oventrop Regudis W GSWB Installation and operating instructions

oventrop

oventrop Regudis W GSWB Installation and operating instructions

Signature Hardware EDENTON SHSH2020G quick start guide

Signature Hardware

Signature Hardware EDENTON SHSH2020G quick start guide

glass 1989 pasodoble 140 manual

glass 1989

glass 1989 pasodoble 140 manual

CIFIAL 3215001 instruction manual

CIFIAL

CIFIAL 3215001 instruction manual

JADO Borma 814 536 Series installation instructions

JADO

JADO Borma 814 536 Series installation instructions

Oceanic Infra Red Sauna owner's manual

Oceanic

Oceanic Infra Red Sauna owner's manual

Tylo 2900 2665 manual

Tylo

Tylo 2900 2665 manual

Harvia S1616CV Instructions for installation

Harvia

Harvia S1616CV Instructions for installation

Uponor WIPEX instruction sheet

Uponor

Uponor WIPEX instruction sheet

Delta 590-PALGHDF manual

Delta

Delta 590-PALGHDF manual

Delta 35716LF Series manual

Delta

Delta 35716LF Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.