Subject: NEMA Plug Reference Chart Date: December 16, 2005
Applies to: All Models for USA and Canada
Voltage (AC) Wires Phase Circuit NEMA Plug
120 2+Ground Single 15 Amp
5-15P
120 2+Ground Single 20 Amp
5-20P
120/208-240
3+Ground Single 30 Amp
L14-30P
120/208-240
4+Ground Three 30 Amp
L21-30P
120/208-240
3+Ground Single 50 Amp
L14-50P
120/208-240
4+Ground Three 50 Amp
L21-50P
480 3+Ground Three 50 Amp
L16-50P
120/208-240
4+Ground Three 60 Amp
L21-60P
For reference only. The NEMA plugs listed above may not be allowed in every area. Consult local
electrical codes before installing any electrical plugs or receptacles. FETCO does not assume any
responsibility for the electrical wiring setup outside the actual equipment.
Units configured for the U.S. and Canada are either 120VAC or dual voltage (120/208-240VAC).
Dual voltage means that the control components operate on 120VAC, and the heating elements
operate on 208-240VAC. A neutral wire is required. Dual voltage does not mean that the unit can
be adjusted to operate on either 120VAC or 240VAC.