Fieldpiece SRS2C User manual

%&#$
• Wireless communication between the platform
and remote control.
• The remote stores in the body of the platform for
convenient carrying.
• Solid aluminum platform with rubber corners
means your scale is rugged enough for the field.
• Diamond plate style rubber pad keeps cylinders
from sliding around the platform.
• Easy synchronization between the platform and
the remote.
• Highly accurate weight sensor.
• Magnetic hat on the remote allows for convenient
display location and keeps your hands free.
• Zero (tare) the scale from the remote.
• Remote control remembers the last zero point,
even after powering on and off (you won’t lose
your calibration even if the scale turns off).
• Bright backlight allows you to read the remote
display in any lighting.
• Auto-power off conserves battery life.
• Battery life for both the platform and remote con-
trol are visible at all times.
• Wireless signal strength indicator.
• The platform automatically goes into standby
when the remote is turned off.
• Long battery life.
%(
This instrument complies with the requirements of
the following:
FCC Rule Part: 15C
ID: VEARF915
CE: EN300 220
C-Tick
)
%#!&%!
The SRS2C is a rugged wireless scale designed
specifically for weighing refrigerant cylinders. The
wireless remote control is securely stored inside the
back of the rugged scale platform. The remote has a
bright blue backlight. The remote can be hung by the
magnetic hat for easy, hands-free measuring. The
platform is made of solid aluminum with rubber cor-
ners to protect against the hazards of daily use.
&$%#%
OPERATION:
1. Turn on the remote. The platform will turn on
automatically if synchronized and in stand-by
mode.
2. Zero (tare) the scale by holding the ZERO button
on the remote for one second.
3. Press the UNITS button on the remote to select
pounds or kilograms.
4. Read weight directly on the remote’s display.
SYNCHRONIZATION:
If “no Sig” or “CH USEd” is displayed when the
remote is powered on, you need to SYNC the remote
to your platform.
1. Check that the platform is powered on.
2. Hold the SYNC button on the remote until search
pattern appears.
3. During the search, hold the SYNC button on the
platform until green SYNC LED blinks.
4. If the sync is successful, the SYNC LED will go
solid and a reading will be shown on the display.
PRESS FOR 1 SECOND
AUTO-OFF
SRS2
Wireless
Refrigerant
Scale
ZERO
SYNC
UNITS
ON/OFF
PRESS FOR
1 SECOND
Wireless Remote
Platform
Opman SRS2C v16
APO: Auto Power Off turns the wireless display off
after 30 minutes. To disable APO, hold the back-
light button and then press the ON/OFF button.
Battery life remaining for remote control.
Battery life remaining for the scale platform.
Wireless signal strength between remote and platform.
Major unit reading, in pounds (Lb) or kilograms (Kg).
Minor unit reading, in ounces (oz) or grams (g).
Combine with major unit for total weight.
For example: if the upper display shows 14 Lb and
the lower display shows 11.50 oz, the total weight is
14 Lbs and 11.50 oz.
"$!#%
Respect the Environment
Always use low-loss hose fittings to minimize
harmful refrigerant gases entering the atmosphere.
Hoses Affect eight
There are two ways to handle this issue:
EASY WAY
Connect the hoses to the system before zeroing
the scale. Once the system is stable, log the
weight displayed before disconnecting from the
system.
HARD WAY
Zero the scale without hoses connected. Then,
connect hoses to the system, and add or recover
refrigerant. Disconnect the hoses from the system
and the tank. Now the display will show the
weight of the added or recovered refrigerant.
G-value compensation
The Earth’s gravitational strength varies depend-
ing on your location on the Earth’s surface. This can
affect the accuracy of your scale readings.
In order to get the most accurate readings possible
you may want to adjust the g-value of your SRS2C.
In order to adjust the g-value of your SRS2C follow
the steps below:
1. Hold the UNITS button while powering on the
SRS2C display. This will take you into the g-value
set up. “G-St” will display momentarliy followed by
your SRS2C’s current g-value.
2. Press the UNITS button to scroll through 9
default g-values and a 10th custom input. To
input a custom value press the UNITS button until
“G-St” is shown on the display. Then use the
BACKLIGHT and SYNC buttons to increase or
decrease the g-value.
3. When you have selected the appropriate g-value
for your area, press the ZERO button to exit.
* Default G-value setting.
G-Values
1.) Los Angeles 9.796*
2.) Taipei 9.790
3.) Mexico City 9.779
4.) Kolkata 9.788
5.) Rio De aneiro 9.788
6.) Sydney 9.797
7.) Tokyo 9.798
8.) Brussels 9.811
9.) Chicago 9.803
10.) Custom input 9.---
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Specifications good in ambient conditions of 73
°
F
±
9
°
F (23°C ±5°C), <75% relative h midity.
Overrange: "OL" mark indication.
Auto power off: 30 minutes.
Operating environment: 32°F (0°C) to 122°F
(50°C) at <75% R.H.
Storage temperature: -4°F (-20°C) to 140°F
(60°C), 0 to 80% R.H. with battery removed.
Accuracy:
±0.03%rdg + 0.25oz (10g) 0 to 66lbs (0 to 30kg)
±0.05%rdg + 0.25oz (10g) 66 to 252lbs (30 to
114kg)
Resolution: 0.25 oz or 10g
Temperature Coefficient: 0.1´(specified accuracy)
per °F.
ireless Range: 1 to 33 feet (0.3 to 10 meters)
Maximum load: 252 lbs (114kg)
Power: Remote: Single standard 9-volt battery,
NEDA 1604, IS 006P, IEC 6F22.
Platform: 6 x AA batteries
Battery life:
Remote: 80 hrs continuous use typical alkaline.
Platform: 100 hrs continuous use typical alkaline.
eight (platform + remote control): 7.1lbs (3.2kg)
%
Clean the exterior with clean dry cloth. Do not use
liquids.
Battery replacement: Separate battery indicators
for the remote and the platform are on the display.
Replace the remote’s battery with a NEDA type
1604 9V battery. The scale platform will also indicate
low battery by the illumination of the LOW-BATT
LED. Replace the platform batteries with 6 AA batter-
ies.
% #'
Call Fieldpiece Instruments for warranty service or
out of warranty pricing. Send check or money order
for the amount quoted. Send the meter freight pre-
paid to Fieldpiece Instruments. Send proof of date
and location of purchase for in-warranty service. The
scale will be repaired or replaced, at the option of
Fieldpiece, and returned via least cost transportation.
%## %(
This scale is warranted against defects in material
or workmanship for one year from date of purchase.
Fieldpiece will replace or repair the defective unit, at
its option, subject to verification of the defect.
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.
Any implied warranties arising from the sale of a
Fieldpiece product, including but not limited to
implied warranties of merchantability and fitness for a
particular purpose, are limited to the above.
Fieldpiece shall not be liable for loss of use of the
instrument or other incidental or consequential dam-
ages, expenses, or economic loss, or for any claim of
such damage, expenses, or economic loss.
State laws vary. The above limitations or exclu-
sions may not apply to you.
!##!"
The SRS2C wireless refrigerant scale is
designed for HVAC/R technicians. Here are some
other standalone products from Fieldpiece
Instruments.
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
PEAK
MUTE ON/OFF
ON/OFF
L/M/H
SENSITIVITY
H
M
L
PEAK
LOW-BATT
PRESS FOR
1 SECOND
SRL2
Infrared
Refrigerant
Leak Detector
BATTERY
CHECK
COM
CAT III
600V
Fieldpiece
Select
M/m
SC260
TRUE RMS
VAC
NCV
AAC
°F°C VDC
MFD
TEMP
AUTO OFF
TYPE K 30V
MAX
SVG3
Fieldpiece
VACUUM
GAUGE
MIN
ALARM
ENTER
UNITS
SVG3
Vacuum Gauge
SRL2K7
Refrigerant Leak
Detector
SC260
True RMS Compact
Clamp Meter
SMAN460
ireless 4 Port Manifold
+ Micron Gauge
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
Table of contents
Other Fieldpiece Scale manuals