Note: All power connections to be installed to
local/national codes by a Certified Electrician.
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com
1
rotected by one or more US atents: 8915613; D702,391; D702,390; D700,732
HP-4 Recessed with Regressed Diffuser Tech Zone 6" Joiner/Ender
Installation Instructions
© 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98180 V2. 04/17
0 - 10V
Dimming
Scan QR code for
helpful video(s)
Tech Zone 6" (C1)
Tech Zone 6" (C2)
Tech Zone 6" (C3)
Tech Zone 6" (C2T)
TECH ONE 6" COLLECTION - CENTER-TO-CENTER T-BAR SPACING
Tech Zone 6" (C3F)
Step 1
Remove diffuser and set aside to prevent it from getting dirty
or damaged. NOTE: If part of a longer run, diffuser will be
reinstalled back into original luminaire section as lengths vary.
Step 2
lace joiner/ender luminaire on ceiling grid next to starter.
End Brackets
#8-18 x 1/2" Combo
Hex Screws (provided)
Step 5
Top Channel
Starter
Joiner
Joiner Plate
(provided)
Plug-Together
Wiring
Secure to
Structure
(by others)
Step 4
Connect plug-together wiring and align joiner with joiner plate. Carefully slide starter
and joiner together.
IMPORTANT STEP: Install the two #8-18 x 1/2" combo hex screws (provided) into
end bracket as shown. Screws can be installed from the left or right. When installed
correctly these hex screws will pull luminaires together to make a tight joint.
CAUTION: Do not over-tighten.
IMPORTANT STEP
Install T-Bar bracket onto luminaire. Secure with #8-18 x 1/4" screws (provided).
Secure luminaire to building structure using tie-wire, as per code.
Secure to
Structure
(by others)
Joiner
Starter
#8-18 x 1/4"
Screws
(provided)
T-Bar Brackets
(provided)
Step 3