1. POSITIONING
1
2. INSTALLATION
TROUBLESHOOTING GUIDE WARRANTY AND DISPOSAL
220-240 V AC 50-60 Hz mains powered smoke alarm. 9V battery back-up.
WARNING: Wiring should be installed by a qualified electrician in accordance with local building standards. The wiring must conform to current regulations for
electrical installations. Check with local building and fire regulations for your property, to ensure compliance.
Optical smoke alarms are suitable for detecting slow smouldering fires. Like other smoke alarms, they can be subject to nuisance alarms from steam and
should not be placed near bathrooms.
For the earliest warning, we recommend smoke alarms are fitted in all rooms where the temperature is between 0°C (32°F) and 40°C (104°F).
Prolonged exposure to temperatures outside those stated above will reduce product life.
This smoke alarm is not intended for any non-residential, commercial or industrial application, nor for any other purpose than described above.
SW1 OPTICAL SMOKE ALARM
USER MANUAL
0359-CPR-00650
EN 14604:2005 +AC:2008
Smoke alarm devices
DOP: SADOP-SW1-01
18
2d
IMPORTANT: The circuit used to Power the alarm must be a 24 hour voltage circuit that cannot be turned off by a switch.
In accordance with BS 5839: Part 6, we recommend: For mains powered alarms, each with an integral standby supply, the mains
electricity supply should take the form of either a) an independent circuit at the dwelling’s main circuit board, in which case no
other electrical equipment should be connected to this circuit (other than a dedicated monitoring device installed to indicate
failure of the mains electricity supply to the alarms); or b) a separately electrically protected, regularly used local lighting circuit.
Check with local building and fire regulations for your property, to ensure compliance.
Ensure dust cover is removed before operation.
The red LED on the front of the alarm should flash once every 32 seconds (approx.) to show that the alarm sensor is in actively
monitoring for smoke. When the test button is pressed, the alarm will flash once every 8 seconds for 8 minutes.
If desired, the alarm can be interconnected with up to 11 other smoke, heat or carbon monoxide alarms
from the FireAngel range via the 'I' connector. (See Optional Interconnecting Feature).
Sprue Safety Products Ltd warrants to the original purchaser that its enclosed smoke alarm be free from defects in materials and workmanship
under normal residential use and service for a period of 5 (five) years from the date of purchase (not including the replaceable battery). Provided
product is sent back to Sprue Safety Products with proof and date of purchase, Sprue Safety Products Ltd hereby warrants that during the
5 (five) year period commencing from the date of purchase Sprue Safety Products Ltd, at its discretion, agrees to replace the unit free of charge.
The warranty on any replacement SW1 alarm, will last for the remainder of the period of the original warranty in respect of the alarm originally
purchased – that is from the date of original purchase and not from the date of receipt of the replacement product. Sprue Safety Products Ltd
reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or in stock. This
warranty applies to the original retail purchaser from the date of original retail purchase and is not transferable. Proof of purchase is required.
This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or
applications not in accordance with the user manual. It does not cover events and conditions outside of Sprue Safety Products Ltd’s control,
such as Acts of God (fire, severe weather etc.). It does not apply to retail stores, service centres or any distributors or agents. Sprue Safety
Products Ltd will not recognise any changes to this warranty by third parties.
Sprue Safety Products Ltd shall not be liable for any incidental or consequential damages caused by the breach of any expressed or implied
warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited
in duration for 5 (five) years.
This warranty does not affect your statutory rights. Except for death or personal injury, Sprue Safety Products Ltd shall not be liable for any loss
of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by you or any
other user of this product.
DISPOSAL
Waste electrical products should not be disposed of with your other household waste. The alarm is ideally suited for disposal within the waste
electronic and electrical equipment (WEEE) recycling scheme.
Please recycle where facilities exist. Check with your local authority, retailer or contact our Technical Support team for recycling/disposal advice
as regional variations apply.
Once the batteries are removed, the low battery warning chirp will stop. The batteries should always be removed before disposal.
D t tt t t D t b
6. LOW BATTERY WARNING
Your alarm requires 1 x 9V (PP3) battery. Under normal use, the battery should last approximately one year.
Use of a battery other than those recommended here may have a detrimental effect on the alarm:
Duracell MN1604, Gold Peak: GP1604S, GP1604A, Raymax: 6F22, 6LR61.
6a When the alarm battery is low, the alarm will ‘chirp’
and the LED will flash every 32 seconds.
6c Twist alarm
anti-clockwise to
remove from base
plate and disconnect
power adapter.
6d Replace the batteries and re-install.
(See 'Installation') 6e Always test the alarm after replacing
the batteries.
2b
Switch off electricity supply.
6b
4a For multiple alarm installations use a ‘three core and earth’ style cable between all the alarms to be interconnected.
Connect the interconnect cable between each alarm's power connector from the white wire.
4b Test each alarm and ensure every connected alarm
sounds within 10 seconds.
Up to 12 FireAngel mains smoke (SW1), heat (HW1) or carbon monoxide (CW1) alarms
can be interconnected on a single network.
4. OPTIONAL INTERCONNECTING FEATURE
10
On an interconnected network, only the alarm that senses the fire will sound and flash its LED. Other connected alarms will sound a
warning but will not flash their LED. Do not connect more than 12 devices.
The interconnect wire (minimum 0.75 mm2 cable) must be treated as Live, it should be insulated and sheathed.
Mains 230V AC
Power Supply
WIRING KEY
= Live
= Interconnect
= Neutral
= Earth
To other alarms
if fitted
Press and hold the test / button for
5 seconds. The alarm will sound.
Switch off electricity supply.
Remove the baseplate by twisting the alarm anti-clockwise.
Connect the house wiring to the power connector provided.
Ensure a permanent connection is made in a suitable junction
box (not provided).
No connection should
be made to the mains
electricity supply
earth terminal.
Terminate house
wiring earth in spare
connector.
Fit the base to ceiling
using the screws
provided. Feed the
wiring through the
hole in the base plate
and connect the
power adapter to
the alarm.
2a Unwrap battery. Insert battery into battery compartment
(match ‘+’ to ‘+’). Remove dust cover. Press and hold the
test / button for 5 seconds. The alarm will sound.
3a Press and hold the
test / button for 5
seconds.
In a known false alarm, the alarm can be silenced temporarily.
3. SILENCE FEATURE
Smoke alarms can react to cooking fumes or other non emergency situations. Your alarm features ‘Silence’ technology.
In the event of a known false alarm you can temporarily silence it by pressing the test / button. After 8 minutes your alarm will
automatically return to full sensitivity.
The red LED on the front of the alarm will flash once every 8 seconds to show that it is in Silence mode.
The alarm will sound continuously and the red LED will flash every second when the alarm senses smoke.
NEVER IGNORE ANY ALARM. If an alarm is sounding, it is warning you of a potentially hazardous situation. Do not ignore it.
Ignoring the alarm may result in injury or death. If your smoke alarm activates and you are not absolutely certain of the source of
smoke, get everyone out of the house immediately.
The alarm will silence for
8 minutes.
3b
8
Technical Support
Online: www.fireangel.co.uk/support
E-mail: technicalsupport@fireangel.co.uk
Phone: 0800 141 2561 (EIRE Phone: 1-800 523 171)
GN4942R6
© Sprue Safety Products Ltd.
Vanguard Centre, Coventry CV4 7EZ, United Kingdom.
www.sprue.com
Note: This user manual is also available in large text and other formats. Please email:
[email protected] or call 0800 141 2561 for further information.
Push and twist the alarm clockwise onto the base plate.
Turn the electricity supply back on and check that the
green LED is on.
2c
5. MAINTENANCE
5a Test the alarm every month.
Press the test / button for 5
seconds. The alarm will sound.
5b Vacuum your alarm
every 3 months.
5c Do not use cleaners or solvents. 5d Do not paint the alarm.
Replace the alarm every
10 years.
5e Do not use any other test method except
the process described in this manual.
2e Remove locking plug from baseplate.
Insert into hole between base plate and alarm
OPTIONAL LOCKING FEATURE
• Check the location of your smoke alarm.
• Clean the smoke alarm.
• Check the location of your smoke alarm.
• Clean the smoke alarm.
• Check that your alarm is connected to the power supply and that the
battery is installed correctly.
• If testing after installation, allow a few seconds for the alarm to settle.
• Push and hold the centre of the test / button firmly for 5 seconds.
• Check that the alarm is properly connected to the mains power.
• Check the location of your smoke alarm.
• Check that your smoke alarm is definitely the source of the chirping;
make sure the noise isn’t coming from another alarm.
• If the alarm ‘chirps’ every 32 seconds and the red LED flashes at the
same time - replace the battery.
• If the alarm ‘chirps’ every 32 seconds without a red LED flash, a fault is
indicated - contact Techincal Support.
• Check that your smoke alarm is connected to the power
supply and that the battery is correctly installed.
If the green LED does not light when the alarm
is connected to power:
If your smoke alarm does not sound during
testing:
If your smoke alarm activates when no smoke
is visible:
If your smoke alarm sounds unusual or
‘chirps’ intermittently:
If you experience frequent unwanted alarms:
Brown (live)
Blue (neutral)
Black or grey (interlink)
Earth
White
Baseplate
Brown
Blue
Power connector
Junction box
(not provided)
To enable removal of the alarm,
withdraw the locking plug with a
pair of pliers.
12-24VDC12-24VDC
300mm
300mm
150mm
150mm
600mm
Your smoke alarm is suitable for the landing,
hallway, bedroom, living room and dining
room
Smoke alarms should be sited at least 300mm
from light fittings and walls. Ideally as central
as possible in the room.
If there is fluorescent lighting, smoke alarms
should be installed at least 1500mm from
these fittings and wiring. Keep any wiring at
least 1000mm from fluorescent lighting. Do
not use circuits containing fluorescent light
fittings or dimmer switches.
Smoke alarms should be positioned at no
more than 600mm vertically below the highest
point in the room.
If positioning your smoke alarm on the wall,
the top of the alarm must be between 150mm
and 300mm below the ceiling, and at least
300mm from a neighbouring wall.
Locations of alarms must be compliant
with either BS 5839: Part 6 or relevant
Building Regulations if in any doubt.