AUTOMATIC POWER
ENGAGE
Your 10 year life smoke alarm is powered
byaninternallithiumpowerpack.Toavoid
unnecessary use of the power pack prior
to installation, and to ease disposal when
the alarm reaches the end of its life, the
alarm is supplied with the power pack in a
deactivated state. The power pack on this
alarm is automatically enabled when the
alarm is fully locked on to the mounting
plate.
IMPORTANT: Your alarm will not
work until it is correctly tted to the
mountingplate.
INTRODUCTION
Congratulations! You’ve made a wise
investment in protecting your family
and home. The ST-622 multi-criteria
high performance detector is the
ultimate alternative to traditional alarms.
Groundbreaking Thermoptek technology
combinestheverylatest inopticalsensing
withthermalenhancement,providingfaster
responsetobothretypeseliminatingthe
need for ionisation sources which can be
harmfultotheenvironment.Inaddition,this
smokealarmallowsthelowbatterywarning
chirptobesilenceduntilitisconvenientto
replace the alarm (recommended within
no more than 7 days). The Sprue Safety
Products range of products is constantly
beingimprovedandexpanded.Pleasevisit
www.reangel.co.uk to nd out about the
latest additions to our range of innovative
products.
IMPORTANT: Thisusermanualcontains
important information regarding the
operation of your FireAngel smoke alarm.
Ensureyoureadthisusermanualfullybefore
installingandoperatingthealarm.Ifyouare
installingthissmokealarmforusebyothers,
youmustleavethismanual(oracopyofit)
withtheenduser.
SENSOR TECHNOLOGY
Traditionally 3 types of senor technology
havebeenusedindomesticsmokealarms.
Optical smoke alarms are typically more
eectiveatdetectingslowburningres.
Ionisationsmoke alarms aregenerallymore
eectiveatdetectingfast,amingres.
Heat alarms are triggered when room
temperature reaches a set point (typically
56°C) these alarms are generally used in
kitchens.
THERMOPTEK SENSOR TECHNOLOGY
This combines an optical sensing chamber
with thermal enhancement. The alarm is
eective at detecting slow burning res,
and constant monitoring of temperature
changesenablesthesensitivityofthealarm
tobeinstantlyincreasedtherebyquickening
thetypicalresponsetimetofastamingres
signicantly.
Thermoptek alarms are “toast-proof”
meaning they can be positioned in area
close to kitchens that may be aected by
cookingfumes.Heatalarmsshouldbeused
inkitchenswhererequired.
APPLICATION
WARNING: Your FireAngel smoke
alarm can be installed into a new
build property as additional protection
to an existing smoke detection system
only. It cannot be used as a substitute for
a hard wired system as required in new
build properties. In this type of property
the building regulations require alarms
to be interlinked. You can obtain further
information from your local re service or
building control department at your local
council oces. These sources generally
provide advice on new builds or projects
thatrequireplanningpermission.
Your smoke alarm typically meets the
minimum requirements for family living
unitsinexistingbuildings,aslongasatleast
one unit is installed on each oor/level of
yourproperty.
Inordertoachievetheearliestrewarning,
we recommend that a smoke alarm is
tted in all rooms where the temperature
is normally between 4°C (40°F) and 38°C
(100°F). Check the section on ‘Positioning’
to ensure that the smoke alarm is to be
correctly positioned for the particular
dwelling into which it is intended to be
installed.
WARNING:The alarmpositionsshown
below are based on typical homes.
Construction and layout of individual
dwellings will vary, so this should be