REV. 10-18-19 Page 3
PAVER-CP-MT/ PAVER-CP-MSI
STEP 1: Determine the best location to install the paver
kit control panel per your installation.
STEP 2: Remove one block from your re pit enclosure
then measure the width between the opening.
Depending on the block width the control panel can be
adjusted to t various openings. NOTE: When
measuring it is recommended but not required to
recess the control panel to protect the valve
components from weather.
STEP 3: After you have determined the location and
measured the width to install the Paver Control Panel
mark the inside of the control panel as shown in
Fig. 4.
STEP: 4 Drill the two holes with a 3/16” concrete drill
bit and secure the paver kit control panel with concrete
screws. Fig. 5 shows front view.
Use the lintel to support the paver above control panel.
The lintel simply lays on top of the paver as shown in
Fig. 4.
NOTE: This manual covers two specic models. This
section will provide a general installation of the
Paver Control Panel. See Table of Contents for specic
instruction for your application. Follow the directions
from your paver block re pit kit to build the actual re
pit. Depending on your re pit pan (at disc or pan)
ensure the Paver Control Panel is installed underneath
the pan or disc.
Be sure the paver patio block kit ts the opening of the
re pit pan or disc before beginning your installation.
Fig. 4 Top view of control panel securing into the paver block.
Fig. 5 Front view of control panel installed, ready for valve
bracket.
Place control panel into position, mark the
two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
LINTEL
With the paver kit face plate bracket (control panel)
installed you are now ready to install the manual gas
valve.
STEP 1: Prepare the two ½” are x ½” MIP 90° brass
elbows by installing gas rated Teon tape or compound
to the male threads and install them into the manual key
valve that came with your re pit. Ensure the ttings
are tight to prevent any gas leaks. See Fig. 6 for proper
orientation.
NOTE: The manual key valve has no particular inlet or
outlet designation therefore the inlet gas can be
connected to any of the ared ends.
CAUTION: Do not use any Teon tape or compound on
the ared ends of the ttings.
½” Flare x ½” MIP
90° Brass Elbow
Manual Key Valve
½” Flare x ½”
MIP 90° Brass
Elbow
Key Valve
Flange
Piezo Ignitor
Mounting Hole
Fig. 6 Manual key valve elbow orientation. Note: The
paver kit face plate bracket (control panel) can be oriented
with Piezo on either the right or left hand side.
GENERAL INSTRUCTIONS
PAVER-CP-MT INSTRUCTIONS