REV. A Page 3
PAVER-CP-TPSI
STEP 1: Determine the best location to install the paver
kit control panel per your installation.
STEP 2: Remove one or two blocks from the re pit
enclosure then measure the width between the opening.
The bracket will t and opening. Depending on the block
width the control panel can be adjusted to t from 8” to
10 ½”. NOTE: When measuring it is recommended but
not required to recess the control panel to protect the
valve components from weather.
Note: Use the linel (supplied with kit) to support the
paver patio blocks above control panel opening. The
lintel simply lays on top of the paver as shown in Fig. 4.
STEP 3: After you have determined the location and
measured the width to install the Paver Kit control panel
mark the inside of the control panel as shown in Fig. 4.
STEP: 4 Drill the two holes with a 3/16” concrete drill
bit and secure the paver kit control panel with concrete
screws.
NOTE: This section provides a general overview of the
Paver Kit Control Panel. Follow the directions from your
paver block re pit kit to build the actual re pit.
Depending on your re pit pan (at disc or pan) ensure
the Paver Kit control panel is installed underneath the
pan or disc.
Be sure the paver patio block kit ts the opening of the
re pit pan or disc before beginning your installation.
Fig. 4 Securing the control panel into the paver block. Lintel
is shown in the gray shading.
Fig. 5 Control panel installed, ready for valve bracket.
Place control panel into position, mark the
two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
LINTEL
GENERAL INSTRUCTIONS
Remove the TPSI valve and bracket assembly from the
carton.
STEP 1: Prepare the re pit gas valve by installing a ⅜”
close nipple and ½” OD Flare x ⅜” brass tting that comes
with the PAVER-CP-TPSI kit into the gas inlet. Use gas
rated Teon tape or compound on the male threads.
Ensure the ttings are tight to prevent any gas leaks.
CAUTION: Do not use any Teon tape or compound on
the ared ends of the ttings.
STEP 2: The TPSI gas valve is supplies partally
assembled. You will need to connect the Piezo wires,
pilot tubing, inlet gas supply and ex line to the re pit.
See Fig. 7.
TPSI VALVE INSTALLATON
Fig. 6 Shows valve assembly removed from shipping bag.