logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. First Alert
  6. •
  7. Smoke Alarm
  8. •
  9. First Alert SA340B User manual

First Alert SA340B User manual

Other First Alert Smoke Alarm manuals

First Alert SC7010BV User guide

First Alert

First Alert SC7010BV User guide

First Alert SA10YRUKN User manual

First Alert

First Alert SA10YRUKN User manual

First Alert ONELINK SA500 User manual

First Alert

First Alert ONELINK SA500 User manual

First Alert SA4121C User manual

First Alert

First Alert SA4121C User manual

First Alert P910 User manual

First Alert

First Alert P910 User manual

First Alert SA511 User manual

First Alert

First Alert SA511 User manual

First Alert SA710 User manual

First Alert

First Alert SA710 User manual

First Alert SA720 User manual

First Alert

First Alert SA720 User manual

First Alert 7020b User manual

First Alert

First Alert 7020b User manual

First Alert SA302 User manual

First Alert

First Alert SA302 User manual

First Alert SA150B User manual

First Alert

First Alert SA150B User manual

First Alert Smoke and Carbon Monoxide Alarm SC01N User manual

First Alert

First Alert Smoke and Carbon Monoxide Alarm SC01N User manual

First Alert SA340 User manual

First Alert

First Alert SA340 User manual

First Alert 100S User manual

First Alert

First Alert 100S User manual

First Alert SA97B User manual

First Alert

First Alert SA97B User manual

First Alert SCO5LB User manual

First Alert

First Alert SCO5LB User manual

First Alert SA520 User manual

First Alert

First Alert SA520 User manual

First Alert 0827 User manual

First Alert

First Alert 0827 User manual

First Alert SCO500A User manual

First Alert

First Alert SCO500A User manual

First Alert 9120 Series User manual

First Alert

First Alert 9120 Series User manual

First Alert SCO2 User manual

First Alert

First Alert SCO2 User manual

First Alert SC7010B User manual

First Alert

First Alert SC7010B User manual

First Alert 7010LBL User manual

First Alert

First Alert 7010LBL User manual

First Alert 0827 User manual

First Alert

First Alert 0827 User manual

Popular Smoke Alarm manuals by other brands

x-sense SD19-W user manual

x-sense

x-sense SD19-W user manual

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

System Sensor DH500ACDC Installation and maintenance instructions

System Sensor

System Sensor DH500ACDC Installation and maintenance instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

VESDA VLF-500 Product guide

VESDA

VESDA VLF-500 Product guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

Aparton ASD-10 Instructions for use

Aparton

Aparton ASD-10 Instructions for use

Greystone DSD120 Installation and maintenance instructions

Greystone

Greystone DSD120 Installation and maintenance instructions

LST ÜMS-55000-841 Specification sheet

LST

LST ÜMS-55000-841 Specification sheet

Radal Technology Cig-Arrête CSA-POD Product installation guide

Radal Technology

Radal Technology Cig-Arrête CSA-POD Product installation guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DUAL IONIZATION
Dual Ionization sensing chamber.
Generally more effective at
detecting small particles produced
by flaming fires.
10-YEAR
LITHIUM POWER
10 years of continuous protection. No
battery change required. Provides
audible notice when alarm has reached
its end of life.
TAMPERPROOF
SEALED ALARM
Powercell cannot be removed after
installation.
SILENCE FEATURE
Silences and tests alarm with a single
button.
Listed to
Standard
UL 217
CAT. SA340B
SMOKE
ALARM
Sealed (Three 3V) Lithium Power Cells
Description:
The First Alert Cat. No. SA340B is a battery operated, 9V (three 3V lithium power
cells) single station smoke alarm specifically designed for residential and
institutional applications including sleeping rooms of hospitals, hotels, motels,
dormitories and other multi-family dwellings as defined in standard NFPA 101.
Model SA340B complies with UL217, CSFM, NFPA 72, HUD, FHA and other
agencies that model their codes after the above agencies. It meets building
codes where tamperproof 10-year sealed lithium battery operated smoke alarms
are required.
First Alert SA340B features a dual ionization smoke sensing chamber, an 85 dB
horn, a sealed 10-year lithium power cell power supply that is permanently
installed upon activation of unit, a single button for test/silence and a red LED
that blinks to indicate unit is receiving power. The tamperproof design will not
allow the powercells to be removed after installation. The low power warning
indicator will cause the alarm to "chirp" when it reaches the end of its service
life and needs to be replaced. Upon end of life, the unit meets UL requirements
for disabling the alarm and non-reinstallation of unit to mounting bracket.
Designed for surface mounting, the SA340B includes mounting anchors and
screws. Includes a gasketless base for easy installation and a new mounting
bracket that keeps the alarm secure over a wide rotation range to allow for
perfect alignment.
10-Year Sealed
brkelectronics.com
ARCHITECTURAL AND ENGINEERING SPEC
TOP
VIEW
2.0”
INSTALLATION OF ALARM
The smoke alarm shall be a First Alert Model SA340B and shall provide at a minimum
the following features and functions:
1. A dual ionization sensing chamber.
2. The unit shall be capable of self restoring.
3. Powered by a sealed 10-year lithium powercell with a tamperproof design. The
tamperproof design shall not allow the powercell to be removed after installation. A
low power warning indicator shall cause the alarm to “chirp” when it reaches the
end of its service life and needs to be replaced. Upon end of life, the unit shall meet
UL requirements for disabling the alarm and the non-reinstallation of unit to
mounting bracket.
4. A solid state piezo horn rated at 85 dB at 10 feet.
5. A visual LED power-on indicator to confirm unit is receiving power or
is in alarm.
6. A full function test button. The test button should check all alarm
functions by stimulating the chamber to simulate a smoke condition,
causing the unit to alarm and also has a silence feature to silence unwanted
nuisance alarms.
7. The unit shall be capable of operating between 40°F (4°C) and
100°F (38°C) and relative humidity between 10% and 90%.
8. The unit shall contain mounting hardware and shall be listed for wall
or ceiling mounting.
9. The unit shall at a minimum meet the requirements of UL217, CSFM,
NFPA 72, NFPA 101, ICC.
Installation of this smoke alarm must conform to NFPA 72. Always check your local
building codes. Follow all instructions for placement as outlined in the user’s manual.
SHIPPING SPECS:
TECHNICAL SPECS
Individual Carton Dimensions 5.75 ”L x 2.00”W x 6.75”H
Weight 0.55 lbs.
Cube 0.05 ft3
UPC 0 29054 00066 8
Master Carton Dimensions 12.75”L x 6.00”W x 7.25”H
Master Pack 6
Weight 3.6 lbs.
Cube 0.32 ft3
I2 of 5 100 29054 00066 5
Pallet Information
Cases per Layer 24
Number of Layers 6
Cases per Pallet 144
Units per Pallet 864
Cube 46.8 ft3
Weight 786 lbs.
Alarm Dimensions: 5.6” dia x 2.0”H
Weight: 6.9 oz.
Operating Voltage: 9V (three 3V) Lithium Power Cells
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 90% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke condition,
causing the unit to alarm
Manual: Press and hold test/silence button
Alarm Reset: Automatic when smoke clears
Smoke Sensor: Dual Ionization
Indicator Lights/Sounds:
DC Power: Intermittent Red Light
Alarm: Audio alarm, rapidly flashing red light
Listing: Listed to UL217 Standard
SIDE
VIEW
BACK
VIEW
CAT. SA340B
©2009 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM2910
THE PARTS OF THIS SMOKE ALARM
1. Mounting bracket
2. Mounting slots
3. 10-Year Lithium Powercell
4. De-activation Tab
(located under label)
5.6”
HOW TO ACTIVATE AND DE-ACTIVATE THIS ALARM
Inserting Powercell De-activating Alarm