manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. First Alert
  6. •
  7. Smoke Alarm
  8. •
  9. First Alert SA500A User manual

First Alert SA500A User manual

This manual suits for next models

1

Other First Alert Smoke Alarm manuals

First Alert SCO2 User manual

First Alert

First Alert SCO2 User manual

First Alert SA320CN User manual

First Alert

First Alert SA320CN User manual

First Alert SCO5LB User manual

First Alert

First Alert SCO5LB User manual

First Alert SA3210 User manual

First Alert

First Alert SA3210 User manual

First Alert 7010B User manual

First Alert

First Alert 7010B User manual

First Alert SCO2 User manual

First Alert

First Alert SCO2 User manual

First Alert SA304 User manual

First Alert

First Alert SA304 User manual

First Alert UL STD 217 User manual

First Alert

First Alert UL STD 217 User manual

First Alert PC1200 User manual

First Alert

First Alert PC1200 User manual

First Alert ZCOMBO-G User manual

First Alert

First Alert ZCOMBO-G User manual

First Alert SA300 User manual

First Alert

First Alert SA300 User manual

First Alert SC7010BV User guide

First Alert

First Alert SC7010BV User guide

First Alert 9120B User manual

First Alert

First Alert 9120B User manual

First Alert 7020b User manual

First Alert

First Alert 7020b User manual

First Alert 4010YR User manual

First Alert

First Alert 4010YR User manual

First Alert SCO7 User manual

First Alert

First Alert SCO7 User manual

First Alert 7010B User manual

First Alert

First Alert 7010B User manual

First Alert OneLink SA500 User manual

First Alert

First Alert OneLink SA500 User manual

First Alert SC7010B User manual

First Alert

First Alert SC7010B User manual

First Alert PR700A User manual

First Alert

First Alert PR700A User manual

First Alert SA302B User manual

First Alert

First Alert SA302B User manual

First Alert SA88B User manual

First Alert

First Alert SA88B User manual

First Alert SA340B User manual

First Alert

First Alert SA340B User manual

First Alert PR710A-6 User manual

First Alert

First Alert PR710A-6 User manual

Popular Smoke Alarm manuals by other brands

Dyna-Glo DGY784BDP installation instructions

Dyna-Glo

Dyna-Glo DGY784BDP installation instructions

NOXE LUMENS Installation and user guide

NOXE

NOXE LUMENS Installation and user guide

Develco SMAZB-141 installation manual

Develco

Develco SMAZB-141 installation manual

Kidde PI2010CA user guide

Kidde

Kidde PI2010CA user guide

Honeywell 5800COMBO Installation and setup guide

Honeywell

Honeywell 5800COMBO Installation and setup guide

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

LST ÜMS-55000-841 Specification sheet

LST

LST ÜMS-55000-841 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Model. SA500A
Cat. 1039831
SMOKE ALARM
First Alert Model SA500A (Cat. 1039831) is a single station smoke
alarm specifically designed for residential and institutional applications
including sleeping rooms of hospitals, hotels, motels, dormitories, and
other multifamily dwellings as defined in standard NFPA 101. Model
SA500A has been fully tested and complies with ULC S531, NFPA
72, and NFPA 101 and other agencies that model their codes after the
above agencies. It meets building codes where battery operated smoke
alarms with wireless interconnect and silence features are required and
with model building codes published by the ICC.
First Alert SA500A is a state of the art wireless smoke alarm
designed to provide early warning of a fire. It features a fully insect
screened Photoelectric smoke sensing chamber, an 85dB horn,
a supervised 3V (2 AA batteries) power supply, a full function test
switch and a silence feature. This smoke alarm interconnects via
wireless communication on a reliable and secure radio frequency
communication of 915 MHz frequency with 65,000 security codes
and 3 channel frequency hopping. When interconnected with other
First Alert Wireless Interconnect alarms it will also announce the
danger and location detected of that alarm too. It operates on a Mesh
Network; a two-way communication format that sends, receives and
re-sends the alarm signals providing a more reliable network. It also
features tamper resistant locking pins that lock alarm to the mounting
bracket and battery drawer to prevent removal of battery or alarm.
Perfect for apartment, dormitory or hotel applications. Designed for
wall or ceiling mounting. Includes mounting anchors and screws.
WIRELESS INTERCONNECT
Reliable and secure radio frequency communication
between alarms. 915 MHz frequency with 65,000 security
codes and 3 channel frequency hopping.
MESH NETWORK COMMUNICATION
2-way communication format that sends, receives and
re-sends the alarm signals providing a more reliable network.
PHOTOELECTRIC
Photoelectric technology is generally more sensitive at
detecting large particles, which tend to be produced in
greater amounts by smoldering fires.
SILENCE FEATURE
Silences nuisance alarms.
TAMPER RESISTANT
Locks alarm to mounting bracket to prevent removal of
battery and/or alarm. Perfect for apartment, dormitory or
hotel applications.
END OF LIFE SIGNAL
Provides audible notice when alarm needs to be replaced
after 10 years.
Model SA500A
ARCHITECTURAL AND ENGINEERING SPECS
The smoke alarm shall be a First Alert Model SA500A (Cat. 1039831) and shall provide at
a minimum the following features and functions:
1. A photoelectric smoke sensing chamber.
2. Wireless interconnect: 915 MHz frequency with 65,000 security codes and 3 channel
frequency hopping.
3. Operates on a Mesh Network; a two-way communication format that sends, receives
and re-sends the alarm signals providing a more reliable network.
4. The unit shall have a lower and varying horn frequency to make it easier for the elderly
with normal age related hearing loss to better hear the horn.
5. A fully screened sensing chamber to resist entry of small insects.
6. Powered by 2 replaceable AA batteries, a solid state horn rated at 85dB at 10 ft and
should be capable of self restoring.
7. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
8. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8 hours.
Alarm Silence: Temporarily silence unwanted nuisance alarms.
9. Two Locking features - tamper resistant locking pins that lock battery drawer and/or
alarm to mounting bracket.
10. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 95%.
11. The unit shall contain mounting hardware and shall be listed for wall or ceiling mounting.
12. The unit shall at a minimum meet the requirements of ULC S531, NFPA 72, NFPA 101,
and ICC.
13. The unit shall have an “End of Life” signal. This signal should be capable of
temporarily being silenced for up to 2 days. After about 2 days, the signal will
resume. After about 2-3 weeks the signal cannot be silenced.
TECHNICAL SPECS
Alarm Dimensions: 5.0" Dia. x 2.0" H
Weight: 8.3 oz
Operating Voltage: 3V (Two 1.5V AA) Battery Powered
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Wireless Frequency: 915 MHz. FCC approved. Complies with
Part 15 of the FCC Rules.
RF Linking: Automatic with 65,000 security codes
Test/Silence: Electronically simulates smoke condition,
causing the unit to alarm. Press and hold
test/silence button.
Alarm Reset: Automatic when smoke clears
Smoke Sensor: Photoelectric
Interconnections: Up to 18 units, RF or hardwired (needs
SA520A Bridge Unit), with smoke, carbon
monoxide, heat alarms and relays.
Maximum 12 smoke alarms.
Listing: Certified to ULC STD S531
SHIPPING SPECS
Individual Carton Dimensions 3.5" L x 6.8" W x 8.5" H
Weight: 0.7 lbs.
Cube: 0.09 ft3
UPC: 0 29054 01897 7
Master Carton Dimensions 10.8" L x 7.0" W x 9.0" H
Master Pack: 3
Weight: 2.4 lbs.
Cube: 0.3 ft3
I2of5: 100 29054 01897 4
Pallet Information
Cases per Layer: 21
Number of Layers: 5
Cases per Pallet: 105
Units per Pallet: 315
Cube: 55.9 ft3
Weight: 283 lbs.
THE PARTS OF THIS ALARM
BATTERY DRAWER LOCK
INSTALLATION OF ALARM
Installation of this smoke alarm must conform to NFPA 72. Always check your local
building codes. Follow all instructions for placement as outlined in the user’s manual in
sections titled “Recommended Locations for Smoke Alarms” and “Locations to Avoid
for Smoke Alarms.”
© 2021 BRK Brands, Inc. All rights reserved. Distributed
by BRK Brands, Inc., Aurora, Illinois 60504. BRK Brands,
Inc. is a subsidiary of Newell Brands Inc. (NASDAQ: NWL).
brkcanada.ca R E V 11/ 20
Remove Pin from
Mounting Bracket
Close Door. Insert Pin in Holes
through alarm and Battery Drawer
Model. SA500A
Cat. 1039831
1. Test/Silence button
2. 2. Slide open battery drawer
3. 3. Power/Alarm LED
4. 4. Horn
5. Mounting bracket
6. Mounting Slots & Locking tabs (Break out Tab)
7. Battery Drawer - Install 2 AA batteries here
8. Twist to attach and remove alarm from bracket
4
3
1
2
5
8
8
6
7
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
5.0"
2.0"