ELECTROCHEMICAL
CO SENSOR
Most accurate technology available for
detecting carbon monoxide as compared to
other sensing technologies.
OPTIPATH 360
TECHNOLOGY
TM
Provides 360 degrees of direct access
to the smoke sensing chambers.
SWEEPING
HORN TONE
Varying horn tone makes it easier for elderly
with normal age related hearing loss to hear
the alarm.
TWO SILENCE
FEATURES
Silences low battery chirp for up to
eight hours or silence nuisance alarm
for several minutes.
TWO LOCKING
FEATURES
Pins are provided to lock battery drawer
and/or alarm to base. Perfect for
apartment, dormitory or hotel
applications.
CAT. SCO5B 9V Battery Powered
SMOKE &CO
COMBO ALARM
PHOTOELECTRIC
First Alert Model SCO5 is a battery operated single station photoelectric smoke
and carbon monoxide combination alarm specifically designed for residential and
institutional applications including sleeping rooms of hospitals, hotels, motels,
dormitories, and other multifamily dwellings as defined in standard NFPA 101.
Model SCO5 has been fully tested and complies with, UL217, UL2034, CSFM,
NFPA 72, and NFPA 101 and other agencies that model their codes after the
above agencies. It meets building codes where battery operated photoelectric
smoke and carbon monoxide combination alarms are required and with model
building codes published by the ICC.
First Alert Model SCO5 is a state of the art smoke and CO combination alarm
designed to provide early warning of a fire or carbon monoxide danger. It
features a photoelectric smoke sensing chamber and an electrochemical CO
sensor. It features a Sweeping Horn Tone that has a lower and varying frequency
that makes it easier for the elderly with normal age related hearing loss to hear
the horn. Two AA alkaline batteries power supply, a single button test/silence
switch. This alarm has two silence features. Low Battery Silence: Temporarily
silence the low battery chirp for up to eight hours. Alarm Silence: Silence alarm
for several minutes. Optipath 360 technologyTM provides 360 degrees of direct
access to the smoke sensing chamber. It also features tamper resistant locking
pins that lock the alarm to the mounting bracket and/or the battery drawer to
prevent removal of battery. Battery installation and removal can occur while the
unit is mounted to the ceiling or wall via the slide out battery drawer. Designed
for wall or ceiling mounting. Includes mounting anchors and screws.
brkelectronics.com
ARCHITECTURAL AND ENGINEERING SPEC
INSTALLATION OF ALARM
The smoke/CO combination alarm shall be a First Alert Model SCO5 and shall provide
at a minimum the following features and functions:
1. A Photoelectric smoke sensing chamber and an electrochemical CO sensor.
2. The unit shall have a lower and varying horn frequency to to make it easier for 
 the elderly with normal age related hearing loss to better hear the horn
3. The unit shall be capable of self restoring.
4. Fully screened smoke sensing chamber to resist entry of small insects thereby 
 reducing the probability of unwanted alarms.
5. Powered by supervised 2 AA alkaline batteries and a solid state piezo horn rated at 
 85dB at 10 ft.
6. A visual green LED power-on indicator to confirm unit is receiving power. A visual 
 red indicator to show unit is alarm.
7. A full function test button should check all alarm functions by simulating a smoke 
 and CO condition, causing the unit to alarm.
8. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8 
 hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
9. Optipath 360 TechnologyTM - provides 360 degrees of direct access to the  
 smoke sensing chambers.
10. Two Locking features - tamper resistant locking pins that lock battery drawer 
 and/or alarm to mounting bracket.
11. The unit shall be capable of operating between 40°F (4°C) and
 100°F (38°C) and relative humidity between 10% and 95%.
12. The unit shall contain mounting hardware and shall be listed for wall
 or ceiling mounting.
13. The unit shall at a minimum meet the requirements of UL217, UL2034, CSFM,
 NFPA 72, NFPA 720, NFPA 101, ICC
Installation of this alarm must conform to NFPA 72 and NFPA 720. Always check your local
building codes. Follow all instructions for placement as outlined in the user’s manual.
SHIPPING SPECS:
TECHNICAL SPECS
Individual Carton Dimensions  5.13 ”L x 2.380”W x 5.13”H
Weight  0.66lbs.
Cube  0.036 ft3
UPC  0 29054 00347 8
Master Carton Dimensions  10.750”L x 7.880”W x 11.06”H
Master Pack 12
Weight  8.4lbs.
Cube  0.542 ft3
UPC  700 29054 00347 7
Pallet Information 
Cases per Layer 22
Number of Layers 4
Cases per Pallet  88
Units per Pallet  1,056
Cube 53.9 ft3
Weight 804 lbs.
©2009 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM2912
CAT.SCO5B
THE PARTS OF THIS SMOKE/CO ALARM
  BOTTOM OF ALARM
 1.  Mounting bracket
 2.  Mounting Slots
 3.  Battery Drawer - Install
  2 AA batteries here
 4.  Turn this way to
  remove from bracket
5.  Turn this way to
  attach to bracket
  TOP OF ALARM
 1. Test/Silence button &
remote control sensor
 2. Slide-open
  battery drawer
 3. Power/smoke alarm light
 4. CO alarm light
BATTERY DRAWER LOCK
Remove Pin from
Mounting Bracket Close Door. Insert Pin in Holes
through alarm and Battery Drawer

5.0"
TOP VIEW SIDE VIEW MOUNTING
BRACKET
2.0"
Alarm Dimensions:  5.0” dia x 2.0”H
Weight:  8.4 oz.
Operating Voltage:  2AA Alkaline Battery Powered
Temperature Range:  40F (4C) to 100F (38C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke and CO conditions,  
 causing the unit to alarm and temporarily silence the alarm
Remote: Use vol/chn buttons on most household IR remotes.
Manual: Press and hold test/silence button
Alarm Reset: Automatic when smoke and/or CO clears
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Indicator Lights/Sounds:
DC Power: Intermittent Red Light
Alarm: Audio Alarm, rapidly flashing red light by corresponding 
 smoke or CO indicator light
Listing: ETL to UL217 and 2034 Standards

This manual suits for next models

1

Other First Alert Smoke Alarm manuals

First Alert 100S User manual

First Alert

First Alert 100S User manual

First Alert SCO500A User manual

First Alert

First Alert SCO500A User manual

First Alert SCO2 User manual

First Alert

First Alert SCO2 User manual

First Alert SA300 User manual

First Alert

First Alert SA300 User manual

First Alert SA3210A User manual

First Alert

First Alert SA3210A User manual

First Alert P910 User manual

First Alert

First Alert P910 User manual

First Alert 3120B User manual

First Alert

First Alert 3120B User manual

First Alert PC910V User manual

First Alert

First Alert PC910V User manual

First Alert SA97B User manual

First Alert

First Alert SA97B User manual

First Alert SA520 User manual

First Alert

First Alert SA520 User manual

First Alert SA340B User manual

First Alert

First Alert SA340B User manual

First Alert SC7010BV User guide

First Alert

First Alert SC7010BV User guide

First Alert SA300 User manual

First Alert

First Alert SA300 User manual

First Alert PC1200 User manual

First Alert

First Alert PC1200 User manual

First Alert SA304 User manual

First Alert

First Alert SA304 User manual

First Alert SA302 User manual

First Alert

First Alert SA302 User manual

First Alert SC9120B User manual

First Alert

First Alert SC9120B User manual

First Alert SA511 User manual

First Alert

First Alert SA511 User manual

First Alert Heat ALarm HD6135F User manual

First Alert

First Alert Heat ALarm HD6135F User manual

First Alert 7020b User manual

First Alert

First Alert 7020b User manual

First Alert SA340B User manual

First Alert

First Alert SA340B User manual

First Alert ZCOMBO-G User manual

First Alert

First Alert ZCOMBO-G User manual

First Alert 9120 Series User manual

First Alert

First Alert 9120 Series User manual

First Alert SA3210 User manual

First Alert

First Alert SA3210 User manual

Popular Smoke Alarm manuals by other brands

STRATOS Micra 100 Installer's handbook

STRATOS

STRATOS Micra 100 Installer's handbook

careium i10 quick start guide

careium

careium i10 quick start guide

LEGRAND Tynetec FireAngel quick start guide

LEGRAND

LEGRAND Tynetec FireAngel quick start guide

MGI BB4KNESmoke user manual

MGI

MGI BB4KNESmoke user manual

Trader BEAR BESMOKEY10BW manual

Trader

Trader BEAR BESMOKEY10BW manual

Apollo 51000-300 manual

Apollo

Apollo 51000-300 manual

Lexing LX-SO-215HT instructions

Lexing

Lexing LX-SO-215HT instructions

BRK electronic Dicon M300 owner's manual

BRK electronic

BRK electronic Dicon M300 owner's manual

Tyco 601PH quick start guide

Tyco

Tyco 601PH quick start guide

Cavius 4002-001 user guide

Cavius

Cavius 4002-001 user guide

Notifier FSH-751 Installation and maintenance instructions

Notifier

Notifier FSH-751 Installation and maintenance instructions

UltraFire UBS1 user manual

UltraFire

UltraFire UBS1 user manual

SIGRIST FireGuard 2 Integral instruction manual

SIGRIST

SIGRIST FireGuard 2 Integral instruction manual

Metrona RM 680110 User information

Metrona

Metrona RM 680110 User information

teko Astra-421 Operation manual

teko

teko Astra-421 Operation manual

Bosch D296 Series installation manual

Bosch

Bosch D296 Series installation manual

Siemens Cerberus DO1101A-Ex Technical description

Siemens

Siemens Cerberus DO1101A-Ex Technical description

Notifier AFP-3030 installation manual

Notifier

Notifier AFP-3030 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.