Model: 29801 Spring Driven Hose Reel
Model: 74988 Reel Kit Pro Spray Valve
Page 2
Item # Description # Req. 29801
2980-R027
75079
9 Bumper Stop Assembly 1
10 Hose Assembly 1
14 Drive Spring 1
31 Swivel Assembly 1
32 Swivel Union 1
Hose I.D. and Length 3/8” x 30 FT
Reel Inlet Connection 3/8” F.P.T.
Max. Operating Pressure 200 P.S.I.
Max. Operating Temperature 160 °F
Item # # Req. Description
Item # Req.# Part Description
Item # # Req. Description Item # # Req. Description
12
1” Snap
31 1
75066 Hose RR 3/8m x 1/2f x 1 1/2 ft
32 12980-R020 Tube vinyl clear 6 inch
33 12913-3/8 Handle 3/4-14f X 3/8f
34 12922-5000 Gasket Handle
35 12990 Pro Spray Valve
36 13298 PST Thread Sealant
Ring 11 1 Guide Arm Assembly 21 1 Latch Bushing
22
Spacing Washer 12 1 Base Assembly 22 1 Latch Spring
33
1/4-10 x 5/8”
Self Tapping Screw 15 1 Spring Case Stud 24 1 O-ring
41
Sheave Flange 16 1 3/8-16 x 1/2” Set Screw 25 1 Latch Plate Assembly
51
Sheave Disk 17 1 Spring Case & Hub Assembly 26 1 10-32 x 1” Machine Screw
61
Latch Cam 18 8 10-32 x 3/8” Nyloc Nut 27 1 U-bolt Hose Clamp
72
Spring Arbor 19 1 Latch Plate Bumper 28 2 1/4-20 Nyloc Nut
87
10-32 x 1/2” Machine Screw 20 1 10-24 x 3/8”Self Tapping Screw 30 1 Main Shaft
31
32
33
34
35
36
1. Connect the lead-in line (31) to the reel (29801) inlet located on the right-hand side of the hose reel,
by appling PST (36) or plumbers tape on the male 3/8” NPT threads on the lead-in line (31) and thead it
to the reel (29801) using a wrench to support the swivel while tightening the lead-in line.
2. Connect the 1/2” female end of the lead-in line (31) to the water supply using PST (36) or plumbers tape
and tighent.
3. Turn on water supply and flush the reel line to remove any debis from the reel for a few seconds and
then turn off water supply.
4. Slide the clear vinyl tube (32) over the reel hose up to the bumper (9).
5. Attach the handle (33) to the reel hose (10). By appling PST (36) or plumbers tape on the 3/8” NPT male threads on reel hose
and tighen.
6. Insert the gasket handle (34) into the handle (33) and then connect the pro spray valve (35).
7. Turn water supply on and check for leaks.
NOTE: Apply PST or Plumber Tape on
the following locations to prevent any
leaks.
1
1
1