manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Flanders
  6. •
  7. Air Cleaner
  8. •
  9. Flanders Rigid Air MERV 10-14 User manual

Flanders Rigid Air MERV 10-14 User manual

1
Flanders PrecisionAire ~ Foremost in Air Filtration
Toll Free
:
1-800-637-2803
Rigid-Air
General
Rigid-Air extended media surface rigid filters are
designed for use in most commercial or industrial
HVAC systems where medium to high efficiency
filtration is required.
They feature your selection of media backed with
expanded metal and pleated. The pleats are held
in place by rigid pleat separators, available in either
plastic or metal styles on 12"depth filters. 6" depth
filters feature rugged fiberboard separators. Rigid-
Air is available in two media types: lofted fiberglass
and micro-fine synthetic with average efficiency
ranges of 50-55%, 60-65%, 80-85% and 90-95%
per ASHRAE Standard 52.1 and MERV 10-14 per
ASHRAE Standard 52.2.
These filters are especially suitable for variable air
volume systems. Operating face velocity ranges
are from 0 to 375 fpm for 6" deep filters, and from
0 to 675 fpm for 12" deep filters. Two frame styles
are available: a single header model and a box type
without header. Rigid-Air filters are UL 900 Class 2
listed. Optional Class 1 listed are available with
metal inserts and fiberglass media.
Installation Considerations
Rigid-Air filters may be installed in Astr Holding
Frames, K-Trac Filter Framing Modules, Sureseal
Side Access Housings or in similar existing
hardware.
The headered version should be selected for use
with the hardware listed. If the filter is to be installed
so that it protrudes upstream of the holding frame,
the box style filter is required.
Physical Data
Frame: 24 ga. corrosion-resistant steel
doubleturned flange makes a stronger frame.
Media: Lofted fiberglass or micro-fine synthetic.
Media Supports: Expanded metal grid with metal
or plastic pleat separator.
Face Grid: Horizontal and diagonal metal supports.
Header: 13/16" wide 26 ga. corrosion-resistant
steel.
Operating Limits: 180° F 100% RH%.
Actual Header or Box Filter Face Size: Nominal
size less 5/8" (e.g., a nominal 24" x 24" filter is
actually 23 3/8" x 23 3/8").
Actual Depth: 5-7/8" or 11-1/2".
Important Features
• Ecologically advanced filtration medium made
entirely from recycled materials.
• Rugged corrosion-resistant steel casing minimizes
damage during shipping and handling.
• Lofted fiberglass micro-fine or synthetic media is
held in position by upstream and downstream
plastic or metal pleat supports.
• Units are available with or without header.
• Filters are completely rigid.
• MERV 10-14
Spun G
lass or Synthetic Media Rigid Filter
Bulletin PB1001-1106
2
Flanders PrecisionAire ~ Foremost in Air Filtration
Toll Free
:
1-800-637-2803
Notes:
1. PD represents clean pressure drop in inches w.g. Recommended final pressure drop for all models is 1.5" w.g.
3. Performance tolerances conform to Section 7.4 of ARI Standard 850.
4. Actual filter face size is 5/8" under on height and width. Actual filter depth is 5-7/8" or 11-1/2"
5. Pressure drop values shown are for synthetic media. Glass media approximately 20% greater.
6. Perfmormance values shown in this publication may be averages or estimates intended to generally represent product
styles. Contact factory for latest actual test data on specific Flanders Precisionaire models.
2. Efficiency is average and is based on ASHRAE Standard 52.1 and 52.2 test methods.
3
Flanders PrecisionAire ~ Foremost in Air Filtration
Toll Free
:
1-800-637-2803
Corrosion Resistant Steel Frame
Choice of media
Lofted fiberglass or
micro-fine synthetic
Diagonal support
prevent racking.
•5-7/8" or 11-1/2"
depths
•Available with or
without header
•Class 1 available
with glass media
and metal fingers.
Robust Media Support
Expanded metal pleat
backng and choice of metal
or plastic pleat supports.
Rigid-Air Box Type Filter
With Metal Pleat Separators
Rigid-Air Filter with Header and
Plastic Pleat Separators
Double Turned flange
for a stronger frame.
4
Flanders PrecisionAire ~ Foremost in Air Filtration
Toll Free
:
1-800-637-2803
1.0 General
1.1 Medium and high efficiency self-supporting filters
shall be Rigid-Air lofted fiberglass or micro-fine
synthetic media rigid filters as manufactured by
Flanders Precisionaire.
1.2 Filter sizes, efficiencies and capacities shall be
as scheduled on the drawings.
2.0 Filter Construction
2.1 Filters shall be constructed of lofted micro-fine
fiberglass or micro-fine synthetic media
laminated to a non-woven backing, bonded to
an expanded metal wire grid and pleated to form
the filter pack.
2.2 The filter pack shall be strengthened on the air
entering and air exiting sides with horizontal and
diagonal metal support members.
2.3 The enclosing frame shall be assembled in a
rigid manner and shall incorporate a header on
the air entering side if required by the application.
2.4 The filter pack shall be sealed into a 24 ga.
corrosion-resistant steel casing with metal or
plastic pleat separators on the upstream and
downstream sides to maintain pleat
configuration.
3.0 Performance
3.1 Initial and final resistances shall not exceed the
scheduled values.
3.2 Media area must equal or exceed that of the
specified filter.
3.3 The average efficiency shall be as determined
by the ASHRAE Standard 52.1 test methods.
3.4 The Filter shall meet MERV 10-14 as determined
by ASHRAE Standard 52.2 test standards.
3.5 The manufacturer shall guarantee performance
as stated in its literature within tolerances as
outlined is Section 7.4 of ARI Standard 850.
3.6 Filters to be UL 900 Class 2 or 1 listed.
Guide Specifications
Application Guidelines
Rigid-Air filters may be used wherever job
requirements and available space will
accommodate 6" or 12" deep filters. Rigid-Air filters
should be selected using 24" x 24" and 24" x 12"
face sizes. This allows for 12" increments in height
and width of the filter bank and insures that
replacement cartridges will be readily available.
Rigid-Air filters should be installed with pleats vertical
wherever possible. It is permissible to install 24" x
12" face size cartridges with pleats horizontal if
necessary to meet the size requirements of the filter
bank.
VAV Systems
Filter banks should be sized so that the maximum
rated flow at design conditions falls within the
published recommended velocities. Rigid-Air filters
may be applied at any capacity between zero flow
and cataloged capacities.
Hospital Applications
Rigid-Air filters may be used on the downstream
side of the supply fan in hospitals if they are far
enough from the fan so that the high fan discharge
velocity will not affect them. Rigid-Air rigid filters can
withstand adverse air flow conditions better than
bag filters and are the preferred selection for these
applications.
Gasketed Headers
Rigid-Air headered filters installed in Flanders K-
Trac Filter Framing Modules or Sureseal Side
Access Housings require gaskets on opposite
header sides to prevent air bypass.
To specify headered version Rigid-Air filters with
gasketed headers, add suffix “SA” (side access),
“GU” (upstream), “GD” (downstream) and “GS”
(sides) to the model number.
Flanders ~ PrecisionAire
Foremost in Air Filtration
Toll Free
:
1-800-637-2803
Representative

This manual suits for next models

1

Other Flanders Air Cleaner manuals

Flanders Crank Lock HEPA Filter Housing C-3 User manual

Flanders

Flanders Crank Lock HEPA Filter Housing C-3 User manual

Flanders Synthetic Media Bag Filters ASHRAE Series User manual

Flanders

Flanders Synthetic Media Bag Filters ASHRAE Series User manual

Flanders Bolt Lock HEPA Filter Housing Surelock B User manual

Flanders

Flanders Bolt Lock HEPA Filter Housing Surelock B User manual

Flanders Super Flow PB1410 User manual

Flanders

Flanders Super Flow PB1410 User manual

Flanders 95% DOP Filter Alpha 95 User manual

Flanders

Flanders 95% DOP Filter Alpha 95 User manual

Flanders MERV 8 Expanded Surface Pleated Filter Pre Pleat... User manual

Flanders

Flanders MERV 8 Expanded Surface Pleated Filter Pre Pleat... User manual

Flanders Alpha-HT PB1403 User manual

Flanders

Flanders Alpha-HT PB1403 User manual

Flanders SwissAire Bag PB1104 User manual

Flanders

Flanders SwissAire Bag PB1104 User manual

Flanders SwissAire R-1 Media SAR-1 Media User manual

Flanders

Flanders SwissAire R-1 Media SAR-1 Media User manual

Flanders Flanders PB100-0507 User manual

Flanders

Flanders Flanders PB100-0507 User manual

Flanders Semi Rigid Figh Dust Holding C apacity Extended Surface Bag Filter Pak... User manual

Flanders

Flanders Semi Rigid Figh Dust Holding C apacity Extended Surface Bag Filter Pak... User manual

Flanders PrecsionCell M16 PB1007-0307 User manual

Flanders

Flanders PrecsionCell M16 PB1007-0307 User manual

Flanders Precisionaire 425T Series User manual

Flanders

Flanders Precisionaire 425T Series User manual

Flanders Washable Metal Filters KKM User manual

Flanders

Flanders Washable Metal Filters KKM User manual

Flanders NESHAP 319 User manual

Flanders

Flanders NESHAP 319 User manual

Flanders 331Y PA User manual

Flanders

Flanders 331Y PA User manual

Flanders PrecisionAire 225T Series User manual

Flanders

Flanders PrecisionAire 225T Series User manual

Flanders Gas Turbine Rigid Filters Cell GT User manual

Flanders

Flanders Gas Turbine Rigid Filters Cell GT User manual

Flanders Flanders FB1100-0606 User manual

Flanders

Flanders Flanders FB1100-0606 User manual

Flanders PrecisionCell II M User manual

Flanders

Flanders PrecisionCell II M User manual

Flanders Precisionaire SAR-1 User manual

Flanders

Flanders Precisionaire SAR-1 User manual

Flanders Precisionaire 425T Series User manual

Flanders

Flanders Precisionaire 425T Series User manual

Flanders Vapor Phase Air Filter PB1209 User manual

Flanders

Flanders Vapor Phase Air Filter PB1209 User manual

Flanders 11255 Series Manual

Flanders

Flanders 11255 Series Manual

Popular Air Cleaner manuals by other brands

Fedders Trion PORT-A-CART Installation, operation & service

Fedders

Fedders Trion PORT-A-CART Installation, operation & service

Haus & Luft HL-OP-11 user manual

Haus & Luft

Haus & Luft HL-OP-11 user manual

brondell Revive PR50-W owner's manual

brondell

brondell Revive PR50-W owner's manual

Bionaire BAP9424 -  2 instruction manual

Bionaire

Bionaire BAP9424 - 2 instruction manual

INNOLIVING PROFESSIONAL ULTRA INN-558 user manual

INNOLIVING

INNOLIVING PROFESSIONAL ULTRA INN-558 user manual

EAS Electric EPUR300UV instruction manual

EAS Electric

EAS Electric EPUR300UV instruction manual

Sharp KI-N50A Operation manual

Sharp

Sharp KI-N50A Operation manual

Inspired TEC IT1500 owner's manual

Inspired TEC

Inspired TEC IT1500 owner's manual

SPX Cooling Technologies Hybrid Cooling Towers brochure

SPX Cooling Technologies

SPX Cooling Technologies Hybrid Cooling Towers brochure

Vortice DEPURO PRO Instruction booklet

Vortice

Vortice DEPURO PRO Instruction booklet

WAGNER WA-777 user manual

WAGNER

WAGNER WA-777 user manual

Bionaire BAP1700 instruction manual

Bionaire

Bionaire BAP1700 instruction manual

Sharp KC-D51R Operation manual

Sharp

Sharp KC-D51R Operation manual

Molekule Molekule quick start guide

Molekule

Molekule Molekule quick start guide

Hunter QuietFLO 30402 owner's manual

Hunter

Hunter QuietFLO 30402 owner's manual

Guardian AC4100 user manual

Guardian

Guardian AC4100 user manual

dreo Macro Pro S user manual

dreo

dreo Macro Pro S user manual

Catalytic CPA QA-20 Owner's operation and maintenance manual

Catalytic

Catalytic CPA QA-20 Owner's operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.