Floodstop FS34NPT User manual

EN
Kits – FS34NPT, FS12NPT, FS14C, FS3/8C, FS1NPT, FS125NPT
Leak Detection & Automatic Water Shut-o System
Installation and Operating Manual
Congratulations on your purchase of a Floodstop electronic water leak detection and automatic water shut-o kit
for water heaters. This product has been designed to give you years of reliable service and minimize home water
damage by detecting water leaks and automatically shutting o the water supply.
To ensure proper installation and to maximize the performance of your Floodstop water leak detection system,
please read this manual thoroughly.
PLEASE READ CAREFULLY BEFORE PROCEEDING: If a leak is detected, the Floodstop Valves will shut o the water
going to the washing machine. This will stop the continuous ow of water from the water supply valve to the
water heater. However, all or some of the water that is already in the water heater and hoses may still leak out
onto the oor.
NOTE: This unit was shipped with an installation and operating manual that contains important information about
its operation. If you are installing this unit for use by others, we recommend you leave this manual – or a copy of
it – with the user.
Water Heater Kit – Model FS3/4NPT
FEATURES:
• Control Panel has easy to read, lighted function buttons
• AC Power with battery backup – For continued operation in the event of power outages
• Solid brass, full port motorized ball valves for dependable, long lasting performance
• Valves automatically shut-o the water supply when a leak is detected
• Automatic monthly maintenance cycling of the valves to ensure reliable operation
• Valves can be opened and closed with the touch of a button
• Activates an audible alarm when a leak is detected
• Mute button to silence the audible alarm
• Can be reset and reused continuously with the touch of a button
• Can be tested at any time with the touch of a button
• Can accommodate additional water leak sensors
• 1 Year Limited Warranty
This Package Contains:
A (1) Floodstop Motorized Brass Valves (3/4”
FIP x 3/4” MIP)
B (1) Control Panel
C (1) Leak Sensor with Paper Sleeve
D (1) AC Adaptor
E (1) Wire Harness
F (1) Hook & Loop Mounting Pad
G (2) Mounting Screws with Anchors
H (1) Pigtail
Check to make sure everything in the package
matches the Contents Listing above. Read the
instructions thoroughly before installing or
operating the Floodstop system.
Warning: Do not put nger(s) inside Floodstop
Valves. Risk of serious injury may occur. Caution: Do not grip plastic motor drive for leverage when tightening
Floodstop Valves.
STOP: You may need to purchase additional ttings to install the Floodstop Valve to your existing water line.
We recommend that you contact a licensed plumber.
WARNING:
• For use with water only.
• Do not install on gas line.
Installation
1. Shut o main water supply valve.
Step 4 instructs you to install the Floodstop Valve (3/4” FIP x ¾”
MIP) between the rigid water line coming o the manual cold
water valve and the water heater. Most rigid lines will be copper.
Evaluate your line and determine which size adapter tting you
will need (the most common one will be 3/4” solder x 3/4” MIP).
Then determine what size union you will need between the
Floodstop Valve and the water heater. Note that in some cases
you can use a exible or corrugated water heater connector in
place of a union.
2. Open faucet nearest water heater to relieve water pressure.
3. Shut o the manual cold water valve that supplies water to the
water heater. Note that the top of the water heater will usually be
marked “Cold” or “Inlet” at the point where the cold water line is
connected.
4. Position the Floodstop Valve so that the arrow on the side of the
valve is pointing to the water heater. Install the Floodstop Valve
between the rigid water line coming from the manual cold water
valve and the water heater. NOTE: The Floodstop Valve should
be installed within 2 feet of the water heater so that the Leak
Sensor can lay at on the oor.
5. Mount the Floodstop Control Panel in an easily accessible location
within 30 inches of the Floodstop Valves. You may mount the
panel using the screws and anchors, or Hook & Loop Mounting
Pad provided. When using the Hook & Loop Mounting Pad, make
sure the adhesive is put on a clean, dry surface. NOTE: Depending
on the location you pick, and the distance between the hot and
cold shut-o valves, you may need to purchase two (2) Floodstop
Control Panel to Valve Extension Wires, Model #FSACEXT9
(available where you purchased your Floodstop System).
6. With the contacts of the wire harness connector facing you, plug
the 6-pin connector end of the Wire Harness into the bottom of
the Control Panel.
7. Take the 2 short wires coming from the Control Panel and
connect each one to a Floodstop Valve (make sure the arrow
on the side of the plugs line up with each other). It does not
matter which wire gets connected to which Floodstop Valve.
NOTE: The Leak Sensor comes with a Paper Sleeve. If the Leak
Sensor is going to make contact with the washing machine, or
any other piece of metal, make sure you leave the Paper Sleeve
on. If the Leak Sensor makes contact with metal, it will signal the
Floodstop Valve to shut o. The Paper Sleeve acts as a barrier
between the Leak Sensor and the metal. When the Paper Sleeve
becomes wet, it will signal the Floodstop Valve to shut o. If the
Leak Sensor will not be contacting metal, you may remove the
Paper Sleeve.
8. Connect plug on end of long at wire coming from Control Panel
to either set of prongs on the Leak Sensor, pushing until plug
snaps in place. Then place Leak Sensor on the oor behind
the washing machine. NOTE: Additional Leak Sensors can
be connected together for added protection. For additional
Leak Sensors, purchase Floodstop Water Leak Sensor, Model
#FSAXS01 (available where you purchased your Floodstop
System). CAUTION: Do not place Leak Sensor or cord in a
walkway, or other location that may cause someone to trip
and fall.
1
4
5
(NO) Output &
Sensitivity Adj
6 pin connector
6
7
8
2
3
A
B
C
D
E
H
F
G
EN

EN
Kits – FS34NPT, FS12NPT, FS14C, FS3/8C, FS1NPT, FS125NPT
Leak Detection & Automatic Water Shut-o System
Installation and Operating Manual
Congratulations on your purchase of a Floodstop electronic water leak detection and automatic water shut-o kit
for water heaters. This product has been designed to give you years of reliable service and minimize home water
damage by detecting water leaks and automatically shutting o the water supply.
To ensure proper installation and to maximize the performance of your Floodstop water leak detection system,
please read this manual thoroughly.
PLEASE READ CAREFULLY BEFORE PROCEEDING: If a leak is detected, the Floodstop Valves will shut o the water
going to the washing machine. This will stop the continuous ow of water from the water supply valve to the
water heater. However, all or some of the water that is already in the water heater and hoses may still leak out
onto the oor.
NOTE: This unit was shipped with an installation and operating manual that contains important information about
its operation. If you are installing this unit for use by others, we recommend you leave this manual – or a copy of
it – with the user.
Water Heater Kit – Model FS3/4NPT
FEATURES:
• Control Panel has easy to read, lighted function buttons
• AC Power with battery backup – For continued operation in the event of power outages
• Solid brass, full port motorized ball valves for dependable, long lasting performance
• Valves automatically shut-o the water supply when a leak is detected
• Automatic monthly maintenance cycling of the valves to ensure reliable operation
• Valves can be opened and closed with the touch of a button
• Activates an audible alarm when a leak is detected
• Mute button to silence the audible alarm
• Can be reset and reused continuously with the touch of a button
• Can be tested at any time with the touch of a button
• Can accommodate additional water leak sensors
• 1 Year Limited Warranty
This Package Contains:
A (1) Floodstop Motorized Brass Valves (3/4”
FIP x 3/4” MIP)
B (1) Control Panel
C (1) Leak Sensor with Paper Sleeve
D (1) AC Adaptor
E (1) Wire Harness
F (1) Hook & Loop Mounting Pad
G (2) Mounting Screws with Anchors
H (1) Pigtail
Check to make sure everything in the package
matches the Contents Listing above. Read the
instructions thoroughly before installing or
operating the Floodstop system.
Warning: Do not put nger(s) inside Floodstop
Valves. Risk of serious injury may occur. Caution: Do not grip plastic motor drive for leverage when tightening
Floodstop Valves.
STOP: You may need to purchase additional ttings to install the Floodstop Valve to your existing water line.
We recommend that you contact a licensed plumber.
WARNING:
• For use with water only.
• Do not install on gas line.
Installation
1. Shut o main water supply valve.
Step 4 instructs you to install the Floodstop Valve (3/4” FIP x ¾”
MIP) between the rigid water line coming o the manual cold
water valve and the water heater. Most rigid lines will be copper.
Evaluate your line and determine which size adapter tting you
will need (the most common one will be 3/4” solder x 3/4” MIP).
Then determine what size union you will need between the
Floodstop Valve and the water heater. Note that in some cases
you can use a exible or corrugated water heater connector in
place of a union.
2. Open faucet nearest water heater to relieve water pressure.
3. Shut o the manual cold water valve that supplies water to the
water heater. Note that the top of the water heater will usually be
marked “Cold” or “Inlet” at the point where the cold water line is
connected.
4. Position the Floodstop Valve so that the arrow on the side of the
valve is pointing to the water heater. Install the Floodstop Valve
between the rigid water line coming from the manual cold water
valve and the water heater. NOTE: The Floodstop Valve should
be installed within 2 feet of the water heater so that the Leak
Sensor can lay at on the oor.
5. Mount the Floodstop Control Panel in an easily accessible location
within 30 inches of the Floodstop Valves. You may mount the
panel using the screws and anchors, or Hook & Loop Mounting
Pad provided. When using the Hook & Loop Mounting Pad, make
sure the adhesive is put on a clean, dry surface. NOTE: Depending
on the location you pick, and the distance between the hot and
cold shut-o valves, you may need to purchase two (2) Floodstop
Control Panel to Valve Extension Wires, Model #FSACEXT9
(available where you purchased your Floodstop System).
6. With the contacts of the wire harness connector facing you, plug
the 6-pin connector end of the Wire Harness into the bottom of
the Control Panel.
7. Take the 2 short wires coming from the Control Panel and
connect each one to a Floodstop Valve (make sure the arrow
on the side of the plugs line up with each other). It does not
matter which wire gets connected to which Floodstop Valve.
NOTE: The Leak Sensor comes with a Paper Sleeve. If the Leak
Sensor is going to make contact with the washing machine, or
any other piece of metal, make sure you leave the Paper Sleeve
on. If the Leak Sensor makes contact with metal, it will signal the
Floodstop Valve to shut o. The Paper Sleeve acts as a barrier
between the Leak Sensor and the metal. When the Paper Sleeve
becomes wet, it will signal the Floodstop Valve to shut o. If the
Leak Sensor will not be contacting metal, you may remove the
Paper Sleeve.
8. Connect plug on end of long at wire coming from Control Panel
to either set of prongs on the Leak Sensor, pushing until plug
snaps in place. Then place Leak Sensor on the oor behind
the washing machine. NOTE: Additional Leak Sensors can
be connected together for added protection. For additional
Leak Sensors, purchase Floodstop Water Leak Sensor, Model
#FSAXS01 (available where you purchased your Floodstop
System). CAUTION: Do not place Leak Sensor or cord in a
walkway, or other location that may cause someone to trip
and fall.
1
4
5
(NO) Output &
Sensitivity Adj
6 pin connector
6
7
8
2
3
A
B
C
D
E
H
F
G
EN

EN
Kits – FS34NPT, FS12NPT, FS14C, FS3/8C, FS1NPT, FS125NPT
Leak Detection & Automatic Water Shut-o System
Installation and Operating Manual
Congratulations on your purchase of a Floodstop electronic water leak detection and automatic water shut-o kit
for water heaters. This product has been designed to give you years of reliable service and minimize home water
damage by detecting water leaks and automatically shutting o the water supply.
To ensure proper installation and to maximize the performance of your Floodstop water leak detection system,
please read this manual thoroughly.
PLEASE READ CAREFULLY BEFORE PROCEEDING: If a leak is detected, the Floodstop Valves will shut o the water
going to the washing machine. This will stop the continuous ow of water from the water supply valve to the
water heater. However, all or some of the water that is already in the water heater and hoses may still leak out
onto the oor.
NOTE: This unit was shipped with an installation and operating manual that contains important information about
its operation. If you are installing this unit for use by others, we recommend you leave this manual – or a copy of
it – with the user.
Water Heater Kit – Model FS3/4NPT
FEATURES:
• Control Panel has easy to read, lighted function buttons
• AC Power with battery backup – For continued operation in the event of power outages
• Solid brass, full port motorized ball valves for dependable, long lasting performance
• Valves automatically shut-o the water supply when a leak is detected
• Automatic monthly maintenance cycling of the valves to ensure reliable operation
• Valves can be opened and closed with the touch of a button
• Activates an audible alarm when a leak is detected
• Mute button to silence the audible alarm
• Can be reset and reused continuously with the touch of a button
• Can be tested at any time with the touch of a button
• Can accommodate additional water leak sensors
• 1 Year Limited Warranty
This Package Contains:
A (1) Floodstop Motorized Brass Valves (3/4”
FIP x 3/4” MIP)
B (1) Control Panel
C (1) Leak Sensor with Paper Sleeve
D (1) AC Adaptor
E (1) Wire Harness
F (1) Hook & Loop Mounting Pad
G (2) Mounting Screws with Anchors
H (1) Pigtail
Check to make sure everything in the package
matches the Contents Listing above. Read the
instructions thoroughly before installing or
operating the Floodstop system.
Warning: Do not put nger(s) inside Floodstop
Valves. Risk of serious injury may occur. Caution: Do not grip plastic motor drive for leverage when tightening
Floodstop Valves.
STOP: You may need to purchase additional ttings to install the Floodstop Valve to your existing water line.
We recommend that you contact a licensed plumber.
WARNING:
• For use with water only.
• Do not install on gas line.
Installation
1. Shut o main water supply valve.
Step 4 instructs you to install the Floodstop Valve (3/4” FIP x ¾”
MIP) between the rigid water line coming o the manual cold
water valve and the water heater. Most rigid lines will be copper.
Evaluate your line and determine which size adapter tting you
will need (the most common one will be 3/4” solder x 3/4” MIP).
Then determine what size union you will need between the
Floodstop Valve and the water heater. Note that in some cases
you can use a exible or corrugated water heater connector in
place of a union.
2. Open faucet nearest water heater to relieve water pressure.
3. Shut o the manual cold water valve that supplies water to the
water heater. Note that the top of the water heater will usually be
marked “Cold” or “Inlet” at the point where the cold water line is
connected.
4. Position the Floodstop Valve so that the arrow on the side of the
valve is pointing to the water heater. Install the Floodstop Valve
between the rigid water line coming from the manual cold water
valve and the water heater. NOTE: The Floodstop Valve should
be installed within 2 feet of the water heater so that the Leak
Sensor can lay at on the oor.
5. Mount the Floodstop Control Panel in an easily accessible location
within 30 inches of the Floodstop Valves. You may mount the
panel using the screws and anchors, or Hook & Loop Mounting
Pad provided. When using the Hook & Loop Mounting Pad, make
sure the adhesive is put on a clean, dry surface. NOTE: Depending
on the location you pick, and the distance between the hot and
cold shut-o valves, you may need to purchase two (2) Floodstop
Control Panel to Valve Extension Wires, Model #FSACEXT9
(available where you purchased your Floodstop System).
6. With the contacts of the wire harness connector facing you, plug
the 6-pin connector end of the Wire Harness into the bottom of
the Control Panel.
7. Take the 2 short wires coming from the Control Panel and
connect each one to a Floodstop Valve (make sure the arrow
on the side of the plugs line up with each other). It does not
matter which wire gets connected to which Floodstop Valve.
NOTE: The Leak Sensor comes with a Paper Sleeve. If the Leak
Sensor is going to make contact with the washing machine, or
any other piece of metal, make sure you leave the Paper Sleeve
on. If the Leak Sensor makes contact with metal, it will signal the
Floodstop Valve to shut o. The Paper Sleeve acts as a barrier
between the Leak Sensor and the metal. When the Paper Sleeve
becomes wet, it will signal the Floodstop Valve to shut o. If the
Leak Sensor will not be contacting metal, you may remove the
Paper Sleeve.
8. Connect plug on end of long at wire coming from Control Panel
to either set of prongs on the Leak Sensor, pushing until plug
snaps in place. Then place Leak Sensor on the oor behind
the washing machine. NOTE: Additional Leak Sensors can
be connected together for added protection. For additional
Leak Sensors, purchase Floodstop Water Leak Sensor, Model
#FSAXS01 (available where you purchased your Floodstop
System). CAUTION: Do not place Leak Sensor or cord in a
walkway, or other location that may cause someone to trip
and fall.
1
4
5
(NO) Output &
Sensitivity Adj
6 pin connector
6
7
8
2
3
A
B
C
D
E
H
F
G
EN

EN
9. Plug the pin on the end of AC Adaptor cord into the bottom of the
Control Panel, and then plug the AC Adaptor into a wall outlet.
Green indicator lights will start to ash, showing you have power.
Note that a red low battery indicator light will also ash about
every 30 seconds, and the unit will beep once a minute until
the batteries are installed. NOTE: If a nearby wall outlet is not
available you will need to purchase a thin low voltage Floodstop
“AC Adaptor Extension Wire” Model #FSAWAE9 (available where
you purchased your Floodstop System). This wire extends
the length of the AC Adaptor cord. CAUTION: Do not plug the AC
Adaptor into an extension cord.
10. Floodstop has a battery backup system that allows the unit to
continue working in the event that you have a power outage. To
set up the backup system, open the front of the Control Panel
and install 4 fresh AA alkaline batteries (batteries not included).
The low battery indicator light will now stop ashing and the
beep will stop. CAUTION: Replace batteries once a year or sooner
as necessary. If batteries need to be changed sooner, a red low
battery indicator light will ash, and a beep will sound.
11. Shut o the previously opened faucet ad turn on both valves
that were shut o in steps 1 and 3. Check for leaks. Note that the
green status light on the Control Panel will indicate whether the
Floodstop Valve is open or closed.
How to Operate your Control Panel
1. Left button opens Floodstop Valve
2. Middle button closes Floodstop Valve
3. Right button mutes the audible alarm that sounds when a leak is
detected
Testing Your Floodstop System
1. Push the Open button to make sure Floodstop Valve is open.
• When the Floodstop Valve is opening or closing, you will hear the valve motor operating for a few seconds.
2. Saturate a rag with water and squeeze over Leak Sensor, or dip the Leak Sensor into a small bucket of water.
Once the Leak Sensor is wet, it will signal the Floodstop Valve to close, then an audible alarm will sound and a
red light will ash.
• Push the Mute button to silence the alarm. Note that the red light will continue to ash. This means the
Floodstop Valve is closed and will remain closed until you push the Open button.
• Before the Floodstop Valve can be opened, the Leak Sensor needs to be dry. There is no need to unplug the
unit when drying o the Leak Sensor.
• The water test can be done with the paper sleeve still on the Leak Sensor. Note that the paper sleeve is
reusable, but once it gets wet you will need to let it air dry at before placing it back on the Leak Sensor.
Pressure Drop Data
The maximum pressure drop for this device is 2 psi at a ow rate of 5.5 gpm for NPS-3/4 and larger.
Helpful Hints
• If the Leak Sensor Paper Sleeve is misplaced or becomes unusable, a paper towel can be used in its place.
• The Leak Sensor has two sets of prongs so you can connect additional Leak Sensors. You can link them
together, so they are positioned at dierent locations around your laundry area.
• Once a month, the Floodstop Valves will automatically close and open by themselves. The Control Panel is
programmed to run this cycle to ensure that the valves continue to function properly in the event that they
need to shut o the water.
• Hanging Wires may be tied together using twist ties (Not provided).
Troubleshooting
Problem What to Check
Status light does not light • Make sure there is power to the outlet.
• Unplug AC Adaptor cord from Control Panel and plug back in.
• If an AC Adaptor extension wire was used, unplug both ends and
reconnect.
• Make sure fresh batteries are in the Control Panel.
No water comes out of hot side of
faucet
• Push Open button to make sure Floodstop Valve is open.
Floodstop Valve does not operate • Make sure both sides of Sensor are dry.
• Make sure there is power to the outlet.
• Unplug AC Adaptor cord from Control Panel and plug back in.
• Unplug 6-pin connector from Control Panel and reconnect.
• Locate plug connection between Control Panel and the Floodstop
Valve that does not operate. Unplug the connection and reconnect,
making sure arrows on side of plugs line up.
• If an AC Adaptor extension wire was used, unplug both ends and
reconnect.
• Make sure fresh batteries are in the Control Panel.
The alarm goes o for no apparent
reason
• Leak Sensor is touching metal, or the concrete is sweating causing
high humidity. Correct the problem by placing the Paper Sleeve on
the Leak Sensor, or use a paper towel as a barrier.
Floodstop Valve does not operate • Unplug 6-pin connector from Control Panel and reconnect.
• Locate plug connection between Control Panel and the Floodstop
Valve that does not operate. Unplug the connection and reconnect,
making sure arrows on side of plugs line up.
• Push the Close button and wait a few seconds. Then push the Open
button.
Manual Operation of Floodstop Valve
1. Unplug the connection between the Control Panel and the Floodstop Valve.
2. Pull the plastic motor cover o the Floodstop Valve and slide it down the wire until it stops at the plug. Note
that no tools are needed to remove the cover.
3. Use a marker and draw a line across the top of the plastic motor housing. This way once the motor is removed
you will know how to reposition it for assembly.
4. Remove the 4 screws using a Phillips head screwdriver.
5. Place thumb and nger on plastic gear and rotate clockwise to open valve or counter clockwise to close it. Do
not use tools to manually open or close valve.
1 Year Limited Warranty
IPS Corporation warrants the enclosed Floodstop product to be free from defects in materials or workmanship,
under normal use and service, for a period of one (1) years from the date of purchase. If at any time during
the warranty period the product is determined to be defective, IPS Corporation shall repair or replace it (at our
option). The warranty is limited to defective parts as stated. All costs of removal and installation of the Floodstop
product, including the replacement of warranty parts, are the responsibility of the purchaser. The manufacturer
shall not be liable for incidental, consequential, or special damages arising at, or in connection with product use
or performance, except as may otherwise be accorded by law. Some states do not allow the exclusion limitation
of incidental or consequential damages, so the limitation may not apply to you. Any damage to this Floodstop
product as a result of misuse, abuse, neglect, accident, improper installation, or any use violating the instruction
manual furnished by us will void this warranty. This warranty does not cover damages or loss caused by defects,
and the owner’s use of the Floodstop product conrms the understanding that this product does not constitute an
insurance policy, and is only a loss mitigation product used to reduce the risk of water damage.
To obtain warranty service, call our Customer Service Department at 1-800-888-8312, or e-mail us at
tncustser[email protected].
Floodstop Water Heater Kit
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
9
10
11
1
2
3
EN

EN
9. Plug the pin on the end of AC Adaptor cord into the bottom of the
Control Panel, and then plug the AC Adaptor into a wall outlet.
Green indicator lights will start to ash, showing you have power.
Note that a red low battery indicator light will also ash about
every 30 seconds, and the unit will beep once a minute until
the batteries are installed. NOTE: If a nearby wall outlet is not
available you will need to purchase a thin low voltage Floodstop
“AC Adaptor Extension Wire” Model #FSAWAE9 (available where
you purchased your Floodstop System). This wire extends
the length of the AC Adaptor cord. CAUTION: Do not plug the AC
Adaptor into an extension cord.
10. Floodstop has a battery backup system that allows the unit to
continue working in the event that you have a power outage. To
set up the backup system, open the front of the Control Panel
and install 4 fresh AA alkaline batteries (batteries not included).
The low battery indicator light will now stop ashing and the
beep will stop. CAUTION: Replace batteries once a year or sooner
as necessary. If batteries need to be changed sooner, a red low
battery indicator light will ash, and a beep will sound.
11. Shut o the previously opened faucet ad turn on both valves
that were shut o in steps 1 and 3. Check for leaks. Note that the
green status light on the Control Panel will indicate whether the
Floodstop Valve is open or closed.
How to Operate your Control Panel
1. Left button opens Floodstop Valve
2. Middle button closes Floodstop Valve
3. Right button mutes the audible alarm that sounds when a leak is
detected
Testing Your Floodstop System
1. Push the Open button to make sure Floodstop Valve is open.
• When the Floodstop Valve is opening or closing, you will hear the valve motor operating for a few seconds.
2. Saturate a rag with water and squeeze over Leak Sensor, or dip the Leak Sensor into a small bucket of water.
Once the Leak Sensor is wet, it will signal the Floodstop Valve to close, then an audible alarm will sound and a
red light will ash.
• Push the Mute button to silence the alarm. Note that the red light will continue to ash. This means the
Floodstop Valve is closed and will remain closed until you push the Open button.
• Before the Floodstop Valve can be opened, the Leak Sensor needs to be dry. There is no need to unplug the
unit when drying o the Leak Sensor.
• The water test can be done with the paper sleeve still on the Leak Sensor. Note that the paper sleeve is
reusable, but once it gets wet you will need to let it air dry at before placing it back on the Leak Sensor.
Pressure Drop Data
The maximum pressure drop for this device is 2 psi at a ow rate of 5.5 gpm for NPS-3/4 and larger.
Helpful Hints
• If the Leak Sensor Paper Sleeve is misplaced or becomes unusable, a paper towel can be used in its place.
• The Leak Sensor has two sets of prongs so you can connect additional Leak Sensors. You can link them
together, so they are positioned at dierent locations around your laundry area.
• Once a month, the Floodstop Valves will automatically close and open by themselves. The Control Panel is
programmed to run this cycle to ensure that the valves continue to function properly in the event that they
need to shut o the water.
• Hanging Wires may be tied together using twist ties (Not provided).
Troubleshooting
Problem What to Check
Status light does not light • Make sure there is power to the outlet.
• Unplug AC Adaptor cord from Control Panel and plug back in.
• If an AC Adaptor extension wire was used, unplug both ends and
reconnect.
• Make sure fresh batteries are in the Control Panel.
No water comes out of hot side of
faucet
• Push Open button to make sure Floodstop Valve is open.
Floodstop Valve does not operate • Make sure both sides of Sensor are dry.
• Make sure there is power to the outlet.
• Unplug AC Adaptor cord from Control Panel and plug back in.
• Unplug 6-pin connector from Control Panel and reconnect.
• Locate plug connection between Control Panel and the Floodstop
Valve that does not operate. Unplug the connection and reconnect,
making sure arrows on side of plugs line up.
• If an AC Adaptor extension wire was used, unplug both ends and
reconnect.
• Make sure fresh batteries are in the Control Panel.
The alarm goes o for no apparent
reason
• Leak Sensor is touching metal, or the concrete is sweating causing
high humidity. Correct the problem by placing the Paper Sleeve on
the Leak Sensor, or use a paper towel as a barrier.
Floodstop Valve does not operate • Unplug 6-pin connector from Control Panel and reconnect.
• Locate plug connection between Control Panel and the Floodstop
Valve that does not operate. Unplug the connection and reconnect,
making sure arrows on side of plugs line up.
• Push the Close button and wait a few seconds. Then push the Open
button.
Manual Operation of Floodstop Valve
1. Unplug the connection between the Control Panel and the Floodstop Valve.
2. Pull the plastic motor cover o the Floodstop Valve and slide it down the wire until it stops at the plug. Note
that no tools are needed to remove the cover.
3. Use a marker and draw a line across the top of the plastic motor housing. This way once the motor is removed
you will know how to reposition it for assembly.
4. Remove the 4 screws using a Phillips head screwdriver.
5. Place thumb and nger on plastic gear and rotate clockwise to open valve or counter clockwise to close it. Do
not use tools to manually open or close valve.
1 Year Limited Warranty
IPS Corporation warrants the enclosed Floodstop product to be free from defects in materials or workmanship,
under normal use and service, for a period of one (1) years from the date of purchase. If at any time during
the warranty period the product is determined to be defective, IPS Corporation shall repair or replace it (at our
option). The warranty is limited to defective parts as stated. All costs of removal and installation of the Floodstop
product, including the replacement of warranty parts, are the responsibility of the purchaser. The manufacturer
shall not be liable for incidental, consequential, or special damages arising at, or in connection with product use
or performance, except as may otherwise be accorded by law. Some states do not allow the exclusion limitation
of incidental or consequential damages, so the limitation may not apply to you. Any damage to this Floodstop
product as a result of misuse, abuse, neglect, accident, improper installation, or any use violating the instruction
manual furnished by us will void this warranty. This warranty does not cover damages or loss caused by defects,
and the owner’s use of the Floodstop product conrms the understanding that this product does not constitute an
insurance policy, and is only a loss mitigation product used to reduce the risk of water damage.
To obtain warranty service, call our Customer Service Department at 1-800-888-8312, or e-mail us at
tncustser[email protected].
Floodstop Water Heater Kit
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
9
10
11
1
2
3
EN

EN
9. Plug the pin on the end of AC Adaptor cord into the bottom of the
Control Panel, and then plug the AC Adaptor into a wall outlet.
Green indicator lights will start to ash, showing you have power.
Note that a red low battery indicator light will also ash about
every 30 seconds, and the unit will beep once a minute until
the batteries are installed. NOTE: If a nearby wall outlet is not
available you will need to purchase a thin low voltage Floodstop
“AC Adaptor Extension Wire” Model #FSAWAE9 (available where
you purchased your Floodstop System). This wire extends
the length of the AC Adaptor cord. CAUTION: Do not plug the AC
Adaptor into an extension cord.
10. Floodstop has a battery backup system that allows the unit to
continue working in the event that you have a power outage. To
set up the backup system, open the front of the Control Panel
and install 4 fresh AA alkaline batteries (batteries not included).
The low battery indicator light will now stop ashing and the
beep will stop. CAUTION: Replace batteries once a year or sooner
as necessary. If batteries need to be changed sooner, a red low
battery indicator light will ash, and a beep will sound.
11. Shut o the previously opened faucet ad turn on both valves
that were shut o in steps 1 and 3. Check for leaks. Note that the
green status light on the Control Panel will indicate whether the
Floodstop Valve is open or closed.
How to Operate your Control Panel
1. Left button opens Floodstop Valve
2. Middle button closes Floodstop Valve
3. Right button mutes the audible alarm that sounds when a leak is
detected
Testing Your Floodstop System
1. Push the Open button to make sure Floodstop Valve is open.
• When the Floodstop Valve is opening or closing, you will hear the valve motor operating for a few seconds.
2. Saturate a rag with water and squeeze over Leak Sensor, or dip the Leak Sensor into a small bucket of water.
Once the Leak Sensor is wet, it will signal the Floodstop Valve to close, then an audible alarm will sound and a
red light will ash.
• Push the Mute button to silence the alarm. Note that the red light will continue to ash. This means the
Floodstop Valve is closed and will remain closed until you push the Open button.
• Before the Floodstop Valve can be opened, the Leak Sensor needs to be dry. There is no need to unplug the
unit when drying o the Leak Sensor.
• The water test can be done with the paper sleeve still on the Leak Sensor. Note that the paper sleeve is
reusable, but once it gets wet you will need to let it air dry at before placing it back on the Leak Sensor.
Pressure Drop Data
The maximum pressure drop for this device is 2 psi at a ow rate of 5.5 gpm for NPS-3/4 and larger.
Helpful Hints
• If the Leak Sensor Paper Sleeve is misplaced or becomes unusable, a paper towel can be used in its place.
• The Leak Sensor has two sets of prongs so you can connect additional Leak Sensors. You can link them
together, so they are positioned at dierent locations around your laundry area.
• Once a month, the Floodstop Valves will automatically close and open by themselves. The Control Panel is
programmed to run this cycle to ensure that the valves continue to function properly in the event that they
need to shut o the water.
• Hanging Wires may be tied together using twist ties (Not provided).
Troubleshooting
Problem What to Check
Status light does not light • Make sure there is power to the outlet.
• Unplug AC Adaptor cord from Control Panel and plug back in.
• If an AC Adaptor extension wire was used, unplug both ends and
reconnect.
• Make sure fresh batteries are in the Control Panel.
No water comes out of hot side of
faucet
• Push Open button to make sure Floodstop Valve is open.
Floodstop Valve does not operate • Make sure both sides of Sensor are dry.
• Make sure there is power to the outlet.
• Unplug AC Adaptor cord from Control Panel and plug back in.
• Unplug 6-pin connector from Control Panel and reconnect.
• Locate plug connection between Control Panel and the Floodstop
Valve that does not operate. Unplug the connection and reconnect,
making sure arrows on side of plugs line up.
• If an AC Adaptor extension wire was used, unplug both ends and
reconnect.
• Make sure fresh batteries are in the Control Panel.
The alarm goes o for no apparent
reason
• Leak Sensor is touching metal, or the concrete is sweating causing
high humidity. Correct the problem by placing the Paper Sleeve on
the Leak Sensor, or use a paper towel as a barrier.
Floodstop Valve does not operate • Unplug 6-pin connector from Control Panel and reconnect.
• Locate plug connection between Control Panel and the Floodstop
Valve that does not operate. Unplug the connection and reconnect,
making sure arrows on side of plugs line up.
• Push the Close button and wait a few seconds. Then push the Open
button.
Manual Operation of Floodstop Valve
1. Unplug the connection between the Control Panel and the Floodstop Valve.
2. Pull the plastic motor cover o the Floodstop Valve and slide it down the wire until it stops at the plug. Note
that no tools are needed to remove the cover.
3. Use a marker and draw a line across the top of the plastic motor housing. This way once the motor is removed
you will know how to reposition it for assembly.
4. Remove the 4 screws using a Phillips head screwdriver.
5. Place thumb and nger on plastic gear and rotate clockwise to open valve or counter clockwise to close it. Do
not use tools to manually open or close valve.
1 Year Limited Warranty
IPS Corporation warrants the enclosed Floodstop product to be free from defects in materials or workmanship,
under normal use and service, for a period of one (1) years from the date of purchase. If at any time during
the warranty period the product is determined to be defective, IPS Corporation shall repair or replace it (at our
option). The warranty is limited to defective parts as stated. All costs of removal and installation of the Floodstop
product, including the replacement of warranty parts, are the responsibility of the purchaser. The manufacturer
shall not be liable for incidental, consequential, or special damages arising at, or in connection with product use
or performance, except as may otherwise be accorded by law. Some states do not allow the exclusion limitation
of incidental or consequential damages, so the limitation may not apply to you. Any damage to this Floodstop
product as a result of misuse, abuse, neglect, accident, improper installation, or any use violating the instruction
manual furnished by us will void this warranty. This warranty does not cover damages or loss caused by defects,
and the owner’s use of the Floodstop product conrms the understanding that this product does not constitute an
insurance policy, and is only a loss mitigation product used to reduce the risk of water damage.
To obtain warranty service, call our Customer Service Department at 1-800-888-8312, or e-mail us at
Floodstop Water Heater Kit
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
9
10
11
1
2
3
EN
Other manuals for FS34NPT
1
Table of contents
Other Floodstop Security Sensor manuals
Popular Security Sensor manuals by other brands

Bentel
Bentel FireClass FC400H manual

Kimo
Kimo FG 110 user manual

Panasonic
Panasonic SF4D-*-01 Series Quick instruction manual

Eaton
Eaton COOPER POWER SERIES Installation and maintenance instructions

Honeywell
Honeywell Miller AirCore Oil & Gas Harness User instruction manual supplement

Pulsar
Pulsar ADS MINI operating instructions

AILF
AILF U10 user manual

STEINEL PROFESSIONAL
STEINEL PROFESSIONAL IS 3360 MX Highbay manual

Nora Lighting
Nora Lighting NX-504-LED installation instructions

ABLE
ABLE Ultima OPIR-5 Installation & maintenance instructions

Hilti
Hilti PS 35 operating instructions

Pfeiffer Vacuum
Pfeiffer Vacuum ASM 340 D Maintenance Instruction