DataLoop™ LI23 Loop-Powered Process Meter Instruction Manual
MN302100 Rev 3 17
Parameter Action/Setting Description
RLY2 Start/stop relay 2 timer
START Start the selected timer output
STOP Stop the selected timer output
STR‐STP Start or stop the selected timer
output
ALARM.FN Set the function key or digital input
to acknowledge an alarm or ac-
cess set points
ACK Acknowledge all active alarms
SETPOINT Access all output set points
SETPT.OC1 Access open collector 1 set point
SETPT.OC2 Access open collector 2 set point
SETPT.R1 Access relay 1 set point
SETPT.R2 Access relay 2 set point
SWATCH.FN Set the function key or digital input
to activate stopwatch
START Start the stopwatch
STOP Pause/Stop the stopwatch
STR‐STP Start or stop the stopwatch
TARE.FN Set the function key or digital input
to tare the display
TARE Tare the display value
RSTTARE Reset the display value
HOLDFN Set the function key or digital input
to hold an output
HOLD.OUT Hold all outputs
HLD.UNHLD Hold or un-hold all outputs
OC1+2 Hold/un-hold open collector out-
puts
RLY1+2 Hold/un-hold relay outputs
mAOUT Hold/un-hold 4-20 mA output
HOLD Hold selected output
HLD.UNHLD Hold or un-hold selected output
DISABLE Disable function key or digital input
RSTFN Set the function key or digital input
to reset a value
RESET Reset min, max, or max/min PV
RMIN.MAX Reset max and min PV value
HINT Display hint text on key press and
execute action on next key press
OFF Turn the hint function off
ON Turn the hint function on
SYSTEM Program system settings
AOUTCAL Calibrate the analog output
DEFAULT Reset meter to factory defaults
PV2 Enable the meter to scale a se-
cond PV based on the mA input
DISABLE Disable dual-scale feature (default)
ENABLE Enable dual-scale feature
BACKLITE Enable/disable display backlight
ENABLE Enable the backlight (default)
DISABLE Disable the backlight
INFO View meter software, version, and
model; change the identifier tag
SFT The software ID number
Parameter Action/Setting Description
VER The software version
MODEL The meter model number
ID.TAG The meter identifier tag
Press Enter to edit tag
ICAL Internal calibration used for scaling
DISPLAY Program the meter’s display
UNITS Change the display units within the
selected unit class
DEC.PT Change the decimal point location
COMMA Enable or disable the use of a
comma on the bottom display
ENABLE Enable comma (default)
DISABLE Disable comma
BARGRAPH Enable or change the bargraph
PV (1 or 2)Set the bargraph to display the PV
percentage of full scale
OFF Turn the bargraph feature off
TOP Set what to display on the top line
PV (1 or 2)Display the process variable
PV+UNIT (1 or 2)Display the process variable and
units alternating
PV+TAG (1 or 2)Display the process variable and
tag alternating
TAG+UNIT Display tag and units alternating
PV+U+TAG (1 or 2)Display the process variable, unit,
and tag alternating
PV1+PV2 Display both process variables
(dual-scale only; see PV2 under
advanced features menu)
TAG Display the tag
STPWATCH Display the stopwatch
TIMROC1 Display open collector 1 timer
TIMROC2 Display open collector 2 timer
TIMERR1 Display relay 1 timer
TIMERR2 Display relay 2 timer
MIN Display minimum value
MAX Display maximum value
MINMAX Display alternating min and max
OFF Turn top line off
UNITS Display the units
BOTTOM Set what to display on the bottom
line
UNITS Display the units
PV (1 or 2)Display the process variable
PV+UNIT (1 or 2)Display the process variable and
unit alternating
PV+TAG (1 or 2)Display the process variable and
tag alternating
TAG+UNIT Display the tag and unit alternating
PV+U+TAG (1 or 2)Display the process variable, unit,
and tag alternating
PV1+PV2 Display both process variables
(dual-scale only; see PV2 under
advanced features menu)
TAG Display the tag
STPWATCH Display the stopwatch