Compact Flow Monitor assembling into Plastic
Saddles DN>200 and Metal Strap-on Saddles
1
Compact Flow Monitor F9.XX assembling into Plastic Saddles DN > 200
and Metal Strap-on Saddles
INSTRUCTION MANUAL
EN 09-05
1. Dismount the F9.XX Flow Monitor
1.1. Remove the front cover
1.2. Unscrew the four
screws and remove the
monitor
1.3. Disconnect the sensor
from the compact
mounting kit
2. Insert the sensor body (2) into the
saddle insert (1), taking care of
rightly position the pins of the
sensor into the seats of the insert (1)
Use sensor length L0 for installation on:
- DN 225 plastic (PP) saddles
- DN 80 to DN 150 metal strap-on
saddles
Use sensor length L1 for installation on
- DN 250 and DN 300 plastic (PP)
saddles
- DN 200 to DN 450 metal strap-on saddles