Fluke Biomedical ESA601 Parts list manual

Electrical
Safety
Analyzer
TE
83
==
Biomedical
ㆍ,
o
Getting
Started
Manual
o
Manuel
d’introduction
o
Manuale
dei
prodotti
o
Einleitungshandbuch
o
Manual
de
funcionamiento
básico
oO
スタ
ー
ト
・
マ
ニュ
アル
о
ЛПЕЖ
156

~
Biomedical
ESA601
Electrical
Safety
Analyzer
Getting
Started
Manual
November
2004
©
2004
Fluke
Biomedical,
All
rights
reserved.
Printed
in
USA
Specifications
subject
to
change
without
notice.

Warranty
Warranty
and
Product
Support
Fluke
Biomedical
warrants
this
instrument
against
defects
in
materials
and
workmanship
for
one
full
year from
the
date
of
original
purchase.
During
the
warranty
period,
we
will
repair
or,
at
our
option,
replace
at
no
charge
a
product
that
proves
to
be
defective,
provided
you
return
the
product,
shipping
prepaid,
to
Fluke
Biomedical.
This
warranty
does
not
apply
if
the
product
has
been
damaged
by
accident
or
misuse
or
as
the
result
of
service
or
modification
by
other
than
Fluke
Biomedical.
INNO
EVENT
SHALL
FLUKE
BIOMEDICAL
BE
LIABLE
FOR
CONSEQUENTIAL
DAMAGES.
Only
serialized
products
and
their
accessory
items
(those
products
and
items
bearing
a
distinct
serial
number
tag)
are
covered
under
this
one-year
warranty.
PHYSICAL
DAMAGE
CAUSED
BY
MISUSE
OR
PHYSICAL
ABUSE
IS
NOT
COVERED
UNDER
THE
WARRANTY.
Items
such
as
cables
and
nonserialized
modules
are
not
covered
under
this
warranty
Recalibration
of
instruments
is
not
covered
under
the
warranty.
This
warranty
gives
you
specific
legal
rights.
You
may
also
have
other
rights
which
vary
from
state
to
state,
province
to
province,
or
country
to
country.
This
warranty
is
limited
to
repairing
the
instrument
to
Fluke
Biomedical’s
specifications.
Warranty
Disclaimer
Should
you
elect
to
have
your
instrument
serviced
and/or
calibrated
by
someone
other
than
Fluke
Biomedical,
please
be
advised
that
the
original
warranty
covering
your
product
becomes
void
when
the
tamper-resistant
Quality Seal
is
removed
or
broken
without
proper
factory
authorization.
We
strongly
recommend,
therefore,
that
you
send
your
instrument
to
Fluke
Biomedical
for
factory
service
and
calibration,
especially
during
the
original
warranty
period,
(When
returning
the
product
for
any
reason,
be
sure
to
follow
the
“Return
Procedure”
in
“Standard
Terms
and
Conditions’
in
the
section
in
the
Operator
s
Manual
called
“Notices.”
In
all
cases,
breaking
the
tamper-resistant
Quality
Seal
should
be
avoided
at
all
cost,
as
this
seal
is
the
key
to
your
original
instrument
warranty.
In
the
event
that
the
seal
must
be
broken
to
gain
internal
access
to
the
instrument,
you
must
first
contact
Fluke
Biomedical's
Technical
Assistance
Department
at
775-883-3400.
You
will
be
required
to
provide
the
serial
number
for
your
instrument
as
well
as
a
valid
reason
for
breaking
the
Quality
Seal.
You
should
break
this
seal
only
after
you
have
received
factory
authorization.
Do
not
break
the
Quality Seal
before
you
have
contacted
us.
Following
these
steps
will
help
ensure
that
you
will
retain
the
original
warranty
on
your
instrument
without
interruption.
Manufacturing
Location
The
ESA601
is
manufactured
in
Everett,
WA,
USA.

Table
of
Contents
Title
Page
Introduction
iii
1
Unpacking
the
ESA6O1
ii
1
|
Storage
and
Maintenance
i
5
|
CharacteristicSs
R
линии
5
Top
and
Side
Panels
eee
5
Back
Panel
............
enses
13
PoweringUp..................................
emer
14
SUDDO
manen
esine
esa aaa
14
Selecting
Language
Options
i
14
|
Selecting
the
Printer
Output
unes
εκει
15
|
Connecting
the
Device
Under
Test...
sisi
16
Selecting
the
Test
Load...
siennes
17
SelectingtheCOperatingMode....................................
nn
17
Performing
Electrical
Safety
Tests
...............
ie
17
Error
CodeS
K
KEE
L
KOREK
RR
KERR
HERO
KRK
P
R
R
18
Power-Up
Diagnostic
Errors
eee
18
StartupDiagnostic
Errors..................................
eee
19

ESA601
Getting
Started
Manual
ЗА
РЯ
20
Specifications...
esse
линии
21
General
Specifications.............................
een
21
Performance
Specifications
em
22
Leakage-Current
Measurement
ss
22
Voltage
Measurement
issu
22
Earth-Resistance
Measurement
ss
23
Insulation
Measurement...
issue
23
VDE
Differential
Current...
sienne
23
Mains
on
Applied
Parts
sise
24
Input/Output-Connection
Specifications
ss
24
Computer-Setup
Specifications...
een
nné
nné
25
il

Table
の の か
の
Oo
一
List
of
Tables
Title
Page
ESA601
Electrical
Safety
Analyzer
(8
versions)
<<<c<<<c<<%<©©<ktrera
2
ACCESSories
ei
АЯ
3
Top
and
Side
Panel
Features...
eme
7
BackPanelFeatures...........................................
erene
13
Power-Up
Diagnostic
Error
Codes
eee
Ran
18
Startup
Diagnostic
Error
COd8S
se
19

List
of
Figures
Figure
Title
Page
1.
TopandSidePanelViewsoftheESA4601.....................................
eee
6
2.
Back
Panel
View
of
the
ESA601
(IEC)
…
せ
ii
ierceaerenrns
11
3.
Back
Panel
View
of
the
ESA601
(AAMI)
ui
nger
12
4.
The
ESA601
Connected
to
a
Device
Under
Test
een
16

ESA601
Getting Started
Manual
A
A
Warning.
Read
before
using
Analyzer.
To
avoid
possible
electrical
shock
or
personal
injury,
follow
these
guidelines:
Do
not
use
the
ESA601
in
any
manner
not
specified
in
the
Operator's
Manual.
Before
connecting
or
disconnecting
a
DUT
to
the
ESA601,
the
FUNCTION-SELECTION
KNOB
should
be
set
to
the
OFF
position.
Exercise
extreme
caution
when
a
shock
hazard
is
present
at
the
instrument's
measurement
terminals
during
the
following
tests:
=
Mains-Insulation
test
»
Applied-Parts-Insulation
test
"
o
Mains-on-Applied-Parts-Leakage-Current
test
"
Equivalent-Device-Leakage-Current
test
»
Equivalent-Patient-Leakage-Current
test
Always
turn
OFF
power
to
the
ESA601
and
unplug
the
power
cord
before
cleaning
the
outer
surface.
Portable
devices
located
in
isolated
power
systems
should
be
tested
on
an
earth-referenced
power
system.
Either
remove
the
DUT
to
an
area
with
an
earth-referenced
power
system,
or
use
an
extension
cord
to
bring
earth-referenced
power
to
the
DUT.
Inspect
the
product,
if
the
instrument
appears
damaged
or
appears
to
operate
in
a
manner
not
specified
in
the
manual,
DO
NOT
CONTINUE
USE.
Return
the
product
for
service.
Avoid
spilling
liquids
on
the
analyzer;
fluid
seepage
into
internal
components
creates
corrosion
and
a
potential
shock
hazard.
Do
not
operate
the
instrument
if
internal
components
are
exposed
to
fluid.
Do
not
open
this
product.
There
are
no
user
replaceable
parts.
vi

Warnings
(continued)
Caution
The
ESA601
should
be
calibrated
annually.
Only
qualified
technical
personnel
should
perform
troubleshooting
and
service
procedures
on
the
ESA601.
Do
not
expose
the
system
to
temperature
extremes.
Ambient
operating
temperatures
should
remain
between
10
to
40
°C.
System
performance
may
be
adversely
affected
if
temperatures
fluctuate
above
or
below
this
range.
Clean
only
with
a
damp,
lint-free
cloth,
using
a
mild
detergent,
and
wipe
down
gently.
Before
each
use,
inspect
the
test-lead
ends
for
possible
wear,
cracks
or
breaks.
Take
leakage-current
measurements
only
after
earth
resistance
is
measured
and
found
to
be
compliant
with
the
applied
safety
limit.
If
the
DUT
fails
the
Protective-Earth-Resistance
test,
the
operator
must
discontinue
testing
and
label the
DUT
defective.*
if
any
single
test
fails,
the
test
must
be
discontinued
immediately
and
the
DUT
labeled
defective.*
"in
order
for
the
ESA601
Controller
Software
to
comply
with
these
statements,
“Stop
Autosequences
On
Failures”
would
need
to
be
checked
on
the
General
tab,
under
the
System
Configure
menu.

Introduction
This
Getting Started
Guide
provides
basic
information
on
Fluke
Biomedical's
ESA601™
Electrical
Safety
Analyzer
(hereafter
called
the
ESA601).
Refer
to
the
Operator’s
Manual
(provided
on
the
CD)
for
complete
operating
instructions.
Table
1
lists
the
eight
available
versions
of
the
ESA601
Electrical
Safety
Analyzer.
Getting
Started
Manual
Unpacking
the
ESA601
Using Table
2
as
a
reference,
unpack
the
ESA601
and
its
accessories
from
the
shipping
carton.
Check
for
missing
parts
and
inspect
the
unit
carefully
for
damage,
such
as
cracks,
dents
or
bent
parts.
If
items
are
missing
or
any
physical
damage
is
apparent,
please
call
Fluke
Biomedical
for
assistance.
For
information
on
ways
to
contact
Fluke
Biomedical,
see
the
section
in
this
manual
called
“Support.”
Also,
notify
the
carrier
if
the
damage
appears
to
be
the
result
of
a
shipping
mishap.

II
mana.
0000
ESA601
Getting
Started
Manual
Table
1.
ESA601
Electrica!
Safety
Analyzer
(8
versions)
。
DUT
Outlet
Detachable
Language
Version
(Test
Receptacle)
Power
Cord
Overlay
Model
#
Australian
Australia/New
Australian
English
1
ESA601-AUS
Zealand
ASINZ
3112-1993
ROW
Schuko
CEE7
European
English
1
ESA601-SHK
(international)
French
Schuko
CEE7
European
French
ESA601-FRA
German
Schuko
CEE7
European
German
ESA601-DEU
Italian
Schuko
CEE7
European
Italian
ESA601-ITAL
United United
Kingdom
British
English
1
ESA601-UK
Kingdom
BS
1363A
United
United
States
120V/15A
English
1
ESA601-USA/IEC
States
NEMA
5-15R
(IEC
Terms)
United
United
States
120
V/15A
English
2
ESA601-USA
States
NEMA
5-15R (AAMI
Terms)

Electrical
Safety
Analyzer
Unpacking
the
ESA601
Table
2.
Accessories
item
Part
Standard
Optional
Number
Accessory Accessory
RED
test
lead
with
probe
2391738
X
BLACK
test
lead
with
probe
2391723
X
ESA601
Operator’s
Manual
&
2388919
X
Controller
Software
CD
Serial
cable
(Null
Modem)
2238626
X
ESA601
Getting Started
2243822
X
Five
alligator/banana
plug
adapters
2391714
X
Soft-sided
carrying
case
2248650
X
Country-specific
power
cord
X

OO
ane
ii
ESA601
Getting
Started
Manual
Table
2.
Accessories
(cont.)
Нет
Part
Standard
Optional
Number
Accessory Accessory
DPU414
serial
printer,
40
columns
2248899
X
with
choice
of
AC
adapter
120-V
AC
adapter
2235375
or
220-V
AC
adapter
2235382
North
American
220-V
adapter
kit
2185787
X
U.S.
220
V
power
cord
2238671
X
DPU414
serial
printer
cable
2238659
X
Alligator
clamp
2004175
X
Banana/ECG
adapters
2391669
X
ESA601
Service
Manual
2243831
X

Storage
and
Maintenance
As
with
most
electronic
equipment,
the
ESA601
should
be
operated
in
a
dry
area
within
normal
temperature
limits
(10
°C
to
40
°C).
The
maximum
relative
humidity
at
temperatures
up
to
31 °C
is
80 %,
decreasing
linearly
to
50
%
relative
humidity
at
40
°C.
There
are
no
special
storage
requirements.
However,
when
storing
the
unit,
maintain
the
storage
temperature
between
-25
°C
and
50
°C.
Although
the
power
output
from
the
ESA601
is
not
potentially
dangerous,
internal
circuits
carry
potentially
lethal
voltages
and
currents.
For
safety
reasons,
maintenance
requiring
internal
access
should
be
performed
only
by
an
experienced
technician.
Electrical
Safety
Analyzer
Storage
and
Maintenance
Characteristics
The
following
two
sections
will
help
familiarize
you
with
the
ESA601
Electrical
Safety
Analyzer's
controls
and
features.
Top
and
Side
Panels
Table
3
lists
and
describes
the
controls
(called
out
in
Figure
1)
located
on
the
top
and
side
panels
of
the
ESA601.
Some
controls
will
have
two
names.
The
first
name
is
the
IEC
nomenclature
and
the
second,
the
AAMI
nomenclature.

ESA601
Getting
Started
Manual
ayg01f.eps
Figure
1.
Top
and
Side
Panel
Views
of
the
ESA601

Electrical
Safety
Analyzer
Characteristics
Table
3.
Top
and
Side
Panel
Features
Name
|
Description
TEST
RECEPTACLE
An
equipment
outlet,
specific
to
the
version
of
the
instrument,
that
provides
a
DUT
connection:
AS
3112-1993
(Australia);
BS
1363A
(English
—United
Kingdom);
NEMA
5-15R
(English
—United
St
ates);
Schuko
CEE7
(French,
German,
Italian,
and
ROW
[international]).
OPEN-NEUTRAL
INDICATOR
An
LED
next
to
the
NEUTRAL
SWITCH,
which
illuminates
with
an
amber
light
(OPEN)
if
Equipment
L2
is
OPEN.
OPEN-EARTH
INDICATOR
OROPEN
|
An
LED
next
to
the
EARTH
(or
GROUND)
SWITCH,
which
illuminates
with
an
GROUND
INDICATOR
amber
light
(OPEN)
if
Equipment
Earth
is
OPEN.
REVERSE-STATUS
INDICATOR
(DUT
|
An
LED
next
to
the
POLARITY
SWITCH,
which
illuminates
with
an
amber
POLARITY)
light
(REVERSE)
if
the
Equipment-Outlet
polarity
is
reversed.
POLARITY
SWITCH
A
rocker
switch
(toggle)
with
two
positions
(NORMAL,
REVERSE),
which
reverses
the
polarity
of
the
Equipment
Outlet
voltage.
EARTH
SWITCH
OR
GROUND
A
rocker switch
(toggle)
with
two
positions
(CLOSED,
OPEN),
which
opens
the
connection
between
Mains
Earth
and
Equipment
Earth
(GROUND).
NEUTRAL
SWITCH
A
rocker switch
(toggle)
with
two
positions
(CLOSED,
OPEN),
which
opens
the
L2
line
on
the
Mains
side
of
the
Mains
POLARITY
SWITCH.

m
mam
ESA601
Getting
Started
Manual
Table
3.
Top
and
Side
Panel
Features
(cont.)
No.
Name
Description
8
M.A.P./
VDE
EQUIV
INSUL
SWITCH
A
rocker
switch
with
three
positions
(NORMAL,
OFF,
REVERSE).
The
OR
ISO
VDE
EQUIV
INSUL
SWITCH
NORMAL
and
REVERSE
positions
are
momentary,
while
the
natural
resting
position
is
OFF.
When
the
MAINS
APPLIED
PARTS
(or
LEAD
ISOLATION)
leakage-current
test
function
is
selected,
this
switch
permits
NORMAL
and
REVERSE
polarity
of
the
isolated
Mains
voltage.
When
either
the
VDE:
EQUIV
PATIENT
Or
VDE:EQUIV
DEVICE
function
is
selected,
this
switch
permits
NORMAL
and
REVERSE
polarity
of
the
isolated
Mains
voltage.
When
either
the
MAINS
INSUL
Or
AP
INSUL
(Or
LEADS
INSUL)
function
is
selected,
this
switch
enables
the
insulation-test
voltage
if
(and
only
if)
the
switch
is
held
down
in
the
NORMAL
position.
9
FUNCTION-SELECTION
KNOB
A
rotary
switch
with
unlimited
rotation,
which
enables
the
selection
of
any
of
sixteen
functions.
10
PRINT
SWITCH
À
rocker
switch
with
a
momentary
activation
in
the
upward
position,
which
sends
the
current
measurement
value
to
an
ASCII
text
printer
through
the
tester
s
RS-232
serial
port.
Applies
only
to
Local
Mode.
11
OVER-RANGE-STATUS
INDICATOR
An
LED
to
the
upper
right
of
the
PRINT
SWITCH,
which
illuminates
with
a
solid
red
light
(OVER
RANGE)
if
the
input
exceeds
measurement
range.

Electrical
Safety
Analyzer
Characteristics
Table
3.
Top
and
Side
Panel
Features
(cont.)
No.
Name
Description
12
HIGH-VOLTS-STATUS
INDICATOR
A
A
An
LED
to
the
lower
right
of
the
PRINT
SWITCH,
with
caution
symbols
underneath,
which
iluminates
with
a
flashing
RED
light
(HIGH
VOLTS)
if
M.A.P.
voltage
or
500
V
DC
is
present
on
either
the
applied
parts
or
L1/L2
on
the
equipment
outlet.
13
OHMS-FUNCTION
SWITCH
A
rocker
switch
that
is
functional
only
while
the
FUNCTION-SELECTION
KNOB
is
positioned
at
the
EARTH
RES
O
(Or
GROUND
WİRE
RES
0)
function.
This
switch
utilizes
three
positions
(OFFSET
/
ZERO
0,
OFF,
MEASURE
(2).
The
mutually
exclusive
OFFSET
/
ZERO
O
and
MEASURE
©
positions
are
momentary,
while
the
natural
resting
position
is
OFF.
A
one-amp
supply
is
turned
ON
when
the
switch
is
depressed
to
either
the
OFFSET
/
ZERO
0
Of
MEASURE
2
position,
and
is
turned
OFF
when
the
switch
is
released.
Meter
readings
are
saved
on
the
display
for
printing
(if
desired)
upon
release
of
the
switch.
A
null
offset
is
generated
when
OFFSET
/
ZERO
O
is
depressed
and
the
meter
reads
<
0.150
ohms;
OL
displays
if
a
null
offset
was
not
generated.
The
null
value
is
stored
until
another
null
is
done.
14
APPLIED-PARTS-SELECTION
KNOB
OR
ECG-LEADS-SELECTION
KNOB
A
rotary
switch
with
eleven usable
positions,
which
enables
the
selection
of
any
individual
—or
all
ten
—applied
parts
(or
ECG
Leads)
connectors.

.--
μμ
n
ESA601
Getting
Started
Manual
Table
3.
Top
and
Side
Panel
Features
(cont.)
No.
Name
Description
15
SIGNAL
CONNECTIONS
Three
safety-style
banana
jacks,
which
provide
signal
connections:
RED
-signal
input
connection
fo
r
Dual-Lead-Voltage,
Dual-Lead-
Leakage,
and
Protective-Earth-Resistance
(or
Ground-Wire-Resistance)
tests,
and
Leakage
Currents;
GREEN
~
direct
connection
to
Equipment
Outlet
Earth;
and
BLACK
-signal
input
connection
for
Dual-Lead-
Voltage
and
Dual-Lead-Leakage
tests.
16
POWER-STATUS
INDICATORS
Two
LEDs
next
to
the
POWER
SWITCH.
The
lower
LED
illuminates
with
a
green
light
(POWER)
when
the
tester
is
switched
on,
while
the
upper
LED
iluminates
with
a
RED
light
(POWER
FAULT)
if
the
inlet
polarity
is
reversed,
or
there
is
a
fatal
error
at
power-up.
17
POWER
SWITCH
A
rocker switch
(toggle)
with
two
positions
(ON,
OFF), which
controls
operating
power
to
the tester.
18
POWER
(MAINS)
INLET
Accepts
a
standard
IEC
60320-1
/
C19
Mains
inlet
rated
at
16
A
and
250
V
for
Class-1
equipment
in
cold
conditions.
19
LOAD-SELECTION
SWITCH
A
slide
switch,
which
permits
the
selection
of
either
the
ANSI
/
AAMI
ES1
or
the
IEC
60601-1
patient
load
20
RS-232
PORT
À
serial
interface,
which,
in
Remote
Mode,
enables
remote
operation
of
the
ESA601,
and
provides
a
download
port
for
processor
firmware.
In
Local
Mode,
this
port
can
be
used
to
output
test
results
to
a
serial
ASCII
printer
when
the
PRINT
SWITCH
is
pressed.
10

Electrical
Safety
Analyzer
Characteristics
=>
En
life
oc
oo“
NO
©:
©
©
©
©
μα
а
Db
Figure
2.
Back
Panel
View
of
the
ESA601
(IEC)
ayqo2f.eps
Table of contents
Other Fluke Biomedical Measuring Instrument manuals

Fluke Biomedical
Fluke Biomedical ASM-990 User manual

Fluke Biomedical
Fluke Biomedical ESA615 User manual

Fluke Biomedical
Fluke Biomedical 180 User manual

Fluke Biomedical
Fluke Biomedical Victoreen 07-494 User manual

Fluke Biomedical
Fluke Biomedical IMPULSE 6000D User manual

Fluke Biomedical
Fluke Biomedical ESA620 User manual

Fluke Biomedical
Fluke Biomedical ESA614 Parts list manual

Fluke Biomedical
Fluke Biomedical VT305 Instruction Manual

Fluke Biomedical
Fluke Biomedical RAYSAFE 452 User manual

Fluke Biomedical
Fluke Biomedical IDA-1S User manual