Features of the Pressure Relief Valve
Protective cap
Reservoir
Nylon seal
Cutaway view O-ring seal
Adjustment
screw
pv02f.eps
The adjustment screw is a cylinder, and has a slot for an
adjustment tool. The adjustment screw compresses a
spring, which determines the relief (cracking) pressure
setting.
Hydraulic fluid inlet and outlet ports are machined into the
body of the 700HTP pump, and are designed for this valve.
When the pressure relief valve is not in use, a threaded
plug must be installed in the pump’s pressure relief valve
port.
Selecting Which Valve to Use
The following table lists the suggested pressure relief valve
for the Fluke Pressure Modules in the 35 bar (500 psi) and
higher ranges.
Fluke 700 Series Pressure
Module Suggest Pressure
Relief Valve
700P07, 700P08, 700P09 Low range
(PRV12-2-HTP1)
700P29, 700P30, 700P31 High range
(PRV12-3-HTP1)
Installing a Pressure Relief Valve
Top view
Pressure
relief valve
O-ring seal
Nylon seal
pv01f.eps
Install a pressure relief valve as shown in the figure above.
Install the nylon seal in the 700HTP pressure relief valve
port first, followed by the O-ring and pressure relief valve.
Note
Use only the nylon seal provided, never thread
sealing tape, with parallel threads.
Adjusting the Pressure Relief Setting
Set the pressure relief by trial and error. The table under
Specifications shows the preset pressure relief settings at
time of shipment. To set the pressure relief lower, turn the
adjustment screw counter-clockwise (loosen it). To set
the pressure relief higher, turn the adjustment screw
clockwise (tighten it).
How to Contact Fluke
To contact Fluke, call one of the following numbers:
1-800-44-FLUKE (1-800-443-5853) in U.S.A. and Canada
+31 402-678-200 in Europe
+81-3-3434-0181 in Japan
+65-*-276-6196 in Singapore
+1-425-356-5500 in other countries
Visit us on the World Wide Web at:
www.fluke.com
Limited Warranty & Limitation of Liability
This Fluke product will be free from defects in material and
workmanship for one year from the date of purchase. This
warranty does not cover fuses, disposable batteries or damage
from accident, neglect, misuse or abnormal conditions of operation
or handling. Resellers are not authorized to extend any other
warranty on Fluke’s behalf. To obtain service during the warranty
period, send your defective calibrator to the nearest Fluke
Authorized Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM
ANY CAUSE OR THEORY. Since some states or countries do not
allow the exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of liability may
not apply to you.
Fluke Corporation Fluke Europe B.V.
P.O. Box 9090 P.O. Box 1186
Everett, WA 98206-9090 5602 B.D. Eindhoven
U.S.A. The Netherlands