manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fluke
  6. •
  7. Measuring Instrument
  8. •
  9. Fluke i430-Flexi-TF-II User manual

Fluke i430-Flexi-TF-II User manual

LIMITED WARRANTY & LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and
workmanship under normal use and service. The warranty period is one year
and begins on the date of shipment. Parts, product repairs and services are
warranted for 90 days. This warranty extends only to the original buyer or end-
user customer of a Fluke authorized reseller, and does not apply to fuses,
disposable batteries or to any product which, in Fluke's opinion, has been
misused, altered, neglected or damaged by accident or abnormal conditions of
operation or handling. Fluke warrants that software will operate substantially in
accordance with its functional specifications for 90 days and that it has been
properly recorded on non-defective media. Fluke does not warrant that software
will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products
to end-user customers only but have no authority to extend a greater or different
warranty on behalf of Fluke. Warranty support is available if product is purchased
through a Fluke authorized sales outlet or Buyer has paid the applicable
international price. Fluke reserves the right to invoice Buyer for importation costs o
f
repair/replacement parts when product purchased in one country is submitted for
repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase
price, free of charge repair, or replacement of a defective product which is returned
to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center or
send the product, with a description of the difficulty, postage and insurance prepaid
(FOB Destination), to the nearest Fluke authorized service center. Fluke assumes
no risk for damage in transit. Following warranty repair, the product will be returned
to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the
failure was caused by misuse, alteration, accident or abnormal condition of
operation or handling, Fluke will provide an estimate of repair costs and obtain
authorization before commencing the work. Following repair, the product will be
returned to the Buyer transportation prepaid and the Buyer will be billed for the
repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING
FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT,
RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied
warranty, or exclusion or limitation of incidental or consequential damages, the
limitations and exclusions of this warranty may not apply to every buyer. If any
provision of this Warranty is held invalid or unenforceable by a court of competent
j
urisdiction, such holding will not affect the validity or enforceability of any other
provision.
Fluke Corporation Fluke Industrial B.V.
P.O. Box 9090 P.O. Box 90
Everett WA 7600 AB Almelo
98206-9090, USA The Netherlands
SERVICE CENTERS
To locate an authorized service center,
visit us on the World Wide Web:
http://www.fluke.com
or call Fluke using any of the phone numbers listed below:
+1-888-993-5853 in U.S.A. and Canada
+31-40-267-5200 in Europe
+1-425-446-5500 from other countries
i430-Flexi-TF-II
6000 A Flexible AC Current Probe
Instruction Sheet
Introducing the i430-Flexi-TF-II
The i430-Flexi-TF-II is a flexible AC current probe for use with the
Fluke 430 series Power Quality Analyzers including Series II. The
i430-Flexi-TF-II is optimized for current measurement on thick and
hard to reach conductors.
Unpacking
The following items should be included in the package:
•i430-Flexi-TF-II Current Probe(s)
•Instruction Sheet (this paper)
Check the contents of the shipping box for completeness. If
something in the box has been damaged or missing, contact your
distributor or the nearest FLUKE sales or service office immediately.
Safety Information
Read First: Safety Information
To prevent possible electrical shock, fire, or personal injury:
•Read all safety information before you use the Product.
•Carefully read all instructions.
•Use the Product only as specified, or the protection supplied
by the Product can be compromised.
•Comply with local and national safety codes. Use personal
protective equipment (approved rubber gloves, face
protection, and flame-resistant clothes) to prevent shock and
arc blast injury where hazardous live conductors are
exposed.
•Limit operation to the specified measurement category,
voltage, or amperage ratings.
•De-energize the circuit or wear personal protective
equipment in compliance with local requirements before you
apply or remove the Flexible Current Probe.
•Do not touch voltages >30 V ac, 42 V ac peak, or 60 V dc.
•Do not use the Product around explosive gas, vapor, or in
damp or wet environments.
•Do not use the Product if it operates incorrectly.
•Before each use, examine the Product. Look for cracks or
missing pieces of the clamp housing or output cable
insulation. Also look for loose or weakened components.
Carefully examine the insulation around the jaws.
•Do not use a current measurement as an indication that a
circuit is safe to touch. A voltage measurement is necessary
to know if a circuit is hazardous.
•Do not use the Product if it is damaged.
PN 4426307
December 2011, Rev.2, 4/14
© 2011-2014 Fluke Corporation.
A
ll rights reserved.
Printed in the EU. All product
names are trademarks of their
respective companies.
Symbols
Do not apply around or remove from HAZARDOUS
LIVE conductors.
Product is protected by double insulation.
Risk of Danger. Important information.
See Instruction Sheet.
Risk of Electric Shock.
Conforms to relevant European standards.
Conforms to relevant North American Safety
Standards.
Conforms to relevant Australian standards.
Do not dispose of this product as unsorted
municipal waste. Go to Fluke’s website for recycling
information.
Specifications
SAFETYThe i430-Flexi-TF-II complies with:
IEC 61010-1: Pollution degree 2
IEC 61010-2-032: 1000V CAT III/ 600V CAT IV
IEC 61010-031
ELECTRICAL SPECIFICATIONS
Measuring range 0.5 to 6000 A ac
Maximum non-destructive
current
100 kA (50/60 Hz)
Output signal 86.6 mV at 1000A/50Hz (on 1 MΩ)
85.0 mV at 1000A/50Hz (on 50 kΩ)
Basic accuracy ±1% of reading at 25 °C, 50 Hz
Linearity ±0.2% of reading at 10%...100% of
range
Noise <1 mV rms at 10 Hz …10 kHz
Additional errors:
●temperature coefficient
over operating temperature
range
0.05 % of reading /°C,
0.09 % of reading /°F
●with position of conductor
in the probe window (see
Figure 1):
A = 12.7 mm (0.5 in)
B = 20.3 mm (0.8 in)
C = 35.6 mm (1.4 in)
●0.5 to 30 A
±0.5 % of reading
±1.0 % of reading
±2.0 % of reading
±1 count or 0.1 A (whichever is
greater)
External magnetic field
rejection in reference to
external current
40 dB (with cable >100 mm from the
head coupling and r-coil)
Phase shift (fundamental
frequency)
< ±1°
Bandwidth (-3 dB) 10 Hz to 10 kHz
Frequency derating I x f ≤385 kA Hz
Working voltage 1000V CAT III, 600V CAT IV
GENERAL SPECIFICATIONS
Weight 153 g
Transducer length 610 mm (24 in)
Transducer diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Cable length from
transducer to BNC
2.5 m (98.4 in)
Temperature, operating -20 °C to +70 °C (-4 °F to +158 °F)
Temperature of conductor under test
shall not exceed 80 °C (176 °F)
Temperature, non-operating -40°C to + 80 °C (-40 °F to +176 °F)
Relative Humidity, operating 15 to 85 %, non condensing
Altitude, operating 3000 m
Altitude, storage 12 km
Instrument Compatibility
The i430-Flexi-TF-II can only be used with the
Fluke 433/434/435/434-II/435-II/437-II Power Quality Analyzers.
Maximum measurement range on all models: 6000 A. Minimum
measurement range on Fluke 433/434/435: 30 A.
Using the i430-Flexi-TF-II
To use the i430-Flexi-TF-II, follow these instructions:
1. Connect the BNC connector of the i430-Flexi-TF-II to the desired
input on the Fluke 430 series Power Quality Analyzer.
i430-Flexi-TF-II: 185 mm (24 in)
C
B
A
1/31/31/3
hcf157.eps
Figure 1. Connecting the flexible probe around the conductor.
2. Connect the flexible probe around the conductor (See Figure 1.)
3. Center the conductor perpendicularly inside the flexible probe
area. If this is not possible, an additional measurement error of
±2 % of reading can occur. See Electrical Specifications.
4. Avoid taking measurements close to other current-carrying
conductors if possible.
5. Make sure that the arrow marked on the probe coupling points
toward the correct orientation for correct phase display on the
instrument. See also the setup screen of the instrument.
6. Keep the probe coupling more than 2.5 cm (1 inch) away from
the conductor.
7. Observe the current value and waveform on the instrument’s
display.
8. Observe the safety instructions when applying and using the
i430-Flexi-TF-II.
Warning
If the selected current probe of the Fluke 430 series
Power Quality Analyzer is not the i430 Flex (on Fluke
430 series I) or i430-Flexi-TF-II (on Fluke 430 series II),
the Fluke 430 will display false and misleading
readings.
Maintenance
Before each use, assure continued safety by inspecting the flexible
probe and its latching system for any damage. Pay particular attention
to the insulation surrounding the flexible probe. An i430-Flexi-TF-II
under warranty will be promptly repaired or replaced (at Fluke's
discretion) and returned at no charge.
 Warning
To prevent possible electrical shock, fire, or personal
injury:
•Remove the input signals before you clean the
Product.
•Have an approved technician repair the Product.
Cleaning and Storage
•The flexible probe and its latching system require no special
care. Ensure that no foreign body obstructs the latching
mechanism.
•Clean the i430-Flexi-TF-II with a damp cloth and a mild
detergent. Do not use abrasives, solvents, or alcohol.
If your i430-Flexi-TF-II does not work
If the i430-Flexi-TF-II does not perform properly, use the following
steps to help isolate the problem:
•Inspect the coupling system for any damage. If any foreign
material is present, the coupling system will not close properly
and errors will result.
•Inspect the cable between the flexible probe and the Power
Quality Analyzer for any damage.
•Check if the i430-Flexi-TF-II is the selected current probe on the
Power Quality Analyzer (Clamp i430-Flexi-TF-II).
•Verify that the function and range selection on the Power Quality
Analyzer is correct.

Other Fluke Measuring Instrument manuals

Fluke 189 User manual

Fluke

Fluke 189 User manual

Fluke ProcessMeter 787 User manual

Fluke

Fluke ProcessMeter 787 User manual

Fluke 715 User manual

Fluke

Fluke 715 User manual

Fluke 365 User manual

Fluke

Fluke 365 User manual

Fluke i5s User manual

Fluke

Fluke i5s User manual

Fluke CertiFiber Pro User manual

Fluke

Fluke CertiFiber Pro User manual

Fluke i310s User manual

Fluke

Fluke i310s User manual

Fluke 481 User manual

Fluke

Fluke 481 User manual

Fluke CableAnalyzer DSP-4000 Series User manual

Fluke

Fluke CableAnalyzer DSP-4000 Series User manual

Fluke 411D Installation and operating instructions

Fluke

Fluke 411D Installation and operating instructions

Fluke 15B MAX User manual

Fluke

Fluke 15B MAX User manual

Fluke 43B User guide

Fluke

Fluke 43B User guide

Fluke 165X User manual

Fluke

Fluke 165X User manual

Fluke 724 User manual

Fluke

Fluke 724 User manual

Fluke 374 User manual

Fluke

Fluke 374 User manual

Fluke 381 User manual

Fluke

Fluke 381 User manual

Fluke OptiView III Series User manual

Fluke

Fluke OptiView III Series User manual

Fluke ESA609 User manual

Fluke

Fluke ESA609 User manual

Fluke MultiFiber Pro User manual

Fluke

Fluke MultiFiber Pro User manual

Fluke v3000 FC User manual

Fluke

Fluke v3000 FC User manual

Fluke 1630 Use and care manual

Fluke

Fluke 1630 Use and care manual

Fluke 5790B User manual

Fluke

Fluke 5790B User manual

Fluke endurance series User manual

Fluke

Fluke endurance series User manual

Fluke 301A User manual

Fluke

Fluke 301A User manual

Popular Measuring Instrument manuals by other brands

Bosch GLL 3 X Professional Original instructions

Bosch

Bosch GLL 3 X Professional Original instructions

BRONKHORST EL-FLOW Prestige Quick installation guide

BRONKHORST

BRONKHORST EL-FLOW Prestige Quick installation guide

WATERGUARD Puddle installation guide

WATERGUARD

WATERGUARD Puddle installation guide

Schaller humimeter BLL user manual

Schaller

Schaller humimeter BLL user manual

Sargon Prospector instruction manual

Sargon

Sargon Prospector instruction manual

JCM Load Monitoring ALRS2 User instructions

JCM Load Monitoring

JCM Load Monitoring ALRS2 User instructions

i4Technology EcoLife Pro1 instruction manual

i4Technology

i4Technology EcoLife Pro1 instruction manual

Chrono-Log 490 4+4 instruction manual

Chrono-Log

Chrono-Log 490 4+4 instruction manual

Honeywell EW44*A Series Installation and setup

Honeywell

Honeywell EW44*A Series Installation and setup

Leica FlexLine plus quick guide

Leica

Leica FlexLine plus quick guide

BARTEC BENKE HYGROPHIL H 4230-12 Ex Zone II operating instructions

BARTEC BENKE

BARTEC BENKE HYGROPHIL H 4230-12 Ex Zone II operating instructions

Eurolube 10400 quick start guide

Eurolube

Eurolube 10400 quick start guide

Stanley T15h Deployment & User Guide

Stanley

Stanley T15h Deployment & User Guide

PCE Health and Fitness PCE-A-315 instruction manual

PCE Health and Fitness

PCE Health and Fitness PCE-A-315 instruction manual

kellermann BL 1000 LED installation instructions

kellermann

kellermann BL 1000 LED installation instructions

TEINNOVA covix mo3 user manual

TEINNOVA

TEINNOVA covix mo3 user manual

Circutor CIRWATT Series installation manual

Circutor

Circutor CIRWATT Series installation manual

PANCONTROL PAN DFA3 manual

PANCONTROL

PANCONTROL PAN DFA3 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.