manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fluke
  6. •
  7. Measuring Instrument
  8. •
  9. Fluke i430-Flexi-TF User manual

Fluke i430-Flexi-TF User manual

Other manuals for i430-Flexi-TF

2

Other Fluke Measuring Instrument manuals

Fluke DewK User manual

Fluke

Fluke DewK User manual

Fluke 323 User manual

Fluke

Fluke 323 User manual

Fluke ScopeMeter 225C User manual

Fluke

Fluke ScopeMeter 225C User manual

Fluke 279 FC User manual

Fluke

Fluke 279 FC User manual

Fluke PLS 3X360R User manual

Fluke

Fluke PLS 3X360R User manual

Fluke 5790A User manual

Fluke

Fluke 5790A User manual

Fluke BT21ANG User manual

Fluke

Fluke BT21ANG User manual

Fluke 434-II Configuration guide

Fluke

Fluke 434-II Configuration guide

Fluke 165X User manual

Fluke

Fluke 165X User manual

Fluke 923 User manual

Fluke

Fluke 923 User manual

Fluke 5618B User manual

Fluke

Fluke 5618B User manual

Fluke NORMA 4000 Operators User manual

Fluke

Fluke NORMA 4000 Operators User manual

Fluke 353 User manual

Fluke

Fluke 353 User manual

Fluke 971 User manual

Fluke

Fluke 971 User manual

Fluke 972A User manual

Fluke

Fluke 972A User manual

Fluke 3210-PR-TF User manual

Fluke

Fluke 3210-PR-TF User manual

Fluke FS17XX User manual

Fluke

Fluke FS17XX User manual

Fluke MultiFiber Pro User manual

Fluke

Fluke MultiFiber Pro User manual

Fluke 321 Technical manual

Fluke

Fluke 321 Technical manual

Fluke PM6690 User manual

Fluke

Fluke PM6690 User manual

Fluke 1736 Configuration guide

Fluke

Fluke 1736 Configuration guide

Fluke DP120 User manual

Fluke

Fluke DP120 User manual

Fluke 714 User manual

Fluke

Fluke 714 User manual

Fluke 1550 User manual

Fluke

Fluke 1550 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

IRIMO 984-6D-1 owner's manual

IRIMO

IRIMO 984-6D-1 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LIMITED WARRANTY & LIMITATION OF LIABILITY
LIMITED WARRANTY & LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and
workmanship under normal use and service. The warranty period is one year
and begins on the date of shipment. Parts, product repairs and services are
warranted for 90 days. This warranty extends only to the original buyer or
end-user customer of a Fluke authorized reseller, and does not apply to
fuses, disposable batteries or to any product which, in Fluke's opinion, has
been misused, altered, neglected or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that software will operate
substantially in accordance with its functional specifications for 90 days and
that it has been properly recorded on non-defective media. Fluke does not
warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused
products to end-user customers only but have no authority to extend a greater o
r
different warranty on behalf of Fluke. Warranty support is available if product is
purchased through a Fluke authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right to invoice Buyer for
importation costs of repair/replacement parts when product purchased in one
country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase
price, free of charge repair, or replacement of a defective product which is
returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center
or send the product, with a description of the difficulty, postage and insurance
prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke
assumes no risk for damage in transit. Following warranty repair, the product will
be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that the failure was caused by misuse, alteration, accident or
abnormal condition of operation or handling, Fluke will provide an estimate of
repair costs and obtain authorization before commencing the work. Following
repair, the product will be returned to the Buyer transportation prepaid and the
Buyer will be billed for the repair and return transportation charges (FOB
Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING
FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT,
RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied
warranty, or exclusion or limitation of incidental or consequential damages, the
limitations and exclusions of this warranty may not apply to every buyer. If any
provision of this Warranty is held invalid or unenforceable by a court of
competent jurisdiction, such holding will not affect the validity or enforceability of
any other provision.
i430-Flexi-TF
6000 A Flexible AC Current Probe
Instruction Sheet
Introducing the i430-Flexi-TF
The i430-Flexi-TF is a flexible AC current probe for use with the
Fluke 430 series Power Quality Analyzers including Series II. The
i430-Flexi-TF is optimized for current measurement on thick and
hard to reach conductors.
Unpacking
The following items should be included in the package:
•i430-Flexi-TF Current Probe(s)
•Instruction Sheet (this paper)
Check the contents of the shipping box for completeness. If
something in the box has been damaged or missing, contact your
distributor or the nearest FLUKE sales or service office immediately.
Safety Information
Read First: Safety Information
To ensure safe operation and service of the current
clamp, follow these instructions:
•Read the operating instructions before use and follow all safety
instructions.
•Use the Current Probe only as specified in the operating
instructions; otherwise the probe’s safety features may not
protect you.
•Adhere to local and national safety codes. Individual protective
equipment must be used to prevent shock and arc blast injury
where hazardous live conductors are exposed.
•Before each use, inspect the Current Probe and its latching
system for any damage. Pay particular attention to the
insulation surrounding the flexible measuring head. Look for
cracks or missing portions of the probe housing or output cable
insulation. Also look for loose or weakened components.
•Do not use a Current Probe that is cracked, damaged, or has a
defective cable.
•Never use the probe on a circuit with voltages higher than
1000 V CAT III or 600V CAT IV
Measurement Category III refers to distribution level and fixed
installation circuits inside a building.
Measurement Category IV refers to the overhead or
underground utility service of an installation.
•De-energize the installation on which current will be measured
or adopt safe operating procedures during application and
removal of the current probe.
•Use extreme caution when working around bare conductors or
bus bars.
•Do apply the Current Probe to bare conductors carrying a
voltage from 30 V up to 1000 V unless you are wearing
protective clothing suitable for high-voltage work. Contact with
the conductor could result in electric shock. Always use
appropriate equipment for personal protection.
•Use caution when working with voltages above 60 V dc, 30 V ac
rms or 42 V ac peak. Such voltages pose a shock hazard.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Symbols
Do not apply around or remove from HAZARDOUS
LIVE conductors.
Product is protected by double insulation.
Risk of Danger. Important information.
See Instruction Sheet.
Risk of Electric Shock.
Conforms to relevant European standards.
Conforms to relevant North American Safety Standards.
Conforms to relevant Australian standards.
Do not dispose of this product as unsorted
municipal waste. Go to Fluke’s website for recycling
information.
Examined and licensed by TÜV Product Services.
ROHS China
Specifications
SAFETY The i430-Flexi-TF complies with:
CAN/CSA-C22.2 No. 61010-1-04ANSI / UL 61010-1:2004EN /
IEC 61010-1:2001EN / IEC 61010-2-032:2002EN /
IEC 61010-031:2002+A1:2008
ELECTRICAL SPECIFICATIONS
Measuring range 0.5 to 6000 A ac
Maximum non-destructive
current
100 kA (50/60 Hz)
Output signal 86.6 mV at 1000A/50Hz (on 1 MΩ)
85.0 mV at 1000A/50Hz (on 50 kΩ)
Basic accuracy ±1% of reading at 25 °C, 50 Hz
Linearity ±0.2% of reading at 10%...100% of
range
Noise < 1 mV rms at 10 Hz …10 kHz
Additional errors:
●temperature coefficient
over operating temperature
range
0.05% of reading /°C,
0.09% of reading /°F
●with position of conductor
in the probe window (see
figure 1):
A = 12.7 mm (0.5 in)
B = 20.3 mm (0.8 in)
C = 35.6 mm (1.4 in)
●0.5 to 30 A
±0.5% of reading
±1.0% of reading
±2.0% of reading
±1 count or 0.1 A (whichever is
greater)
External magnetic field
rejection in reference to
external current
40 dB (with cable >100mm from the
head coupling and r-coil)
Phase shift (fundamental
frequency)
< ±1°
Bandwidth (-3dB) 10 Hz to 10 kHz
Frequency derating I x f ≤385 kA Hz
Working voltage 1000V CAT III, 600V CAT IV
GENERAL SPECIFICATIONS
Weight 195 g
Transducer length 610 mm (24 in)
Transducer diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Cable length from
transducer to BNC
2.5 m (98.4 in)
Temperature, operating -20 to +70°C (-4 to +158°F)
Temperature of conductor under test
shall not exceed 80°C (176°F)
Temperature, non-operating -40 to + 80°C (-40 to +176°F)
Relative Humidity, operating 15 to 85%, non condensing
Altitude, operating 3000 m
Instrument Compatibility
The i430-Flexi-TF can only be used with the Fluke 433/434/435/437
including Series II Power Quality Analyzers.
Using the i430-Flexi-TF
To use the i430-Flexi-TF, follow these instructions:
1. Connect the BNC connector of the i430-Flexi-TF to the desired
input on the Fluke 430 series Power Quality Analyzer.
ABC
Figure 1. Connecting the flexible probe around the conductor.
2. Connect the flexible probe around the conductor (See
Figure 1.)
3. Center the conductor perpendicularly inside the flexible probe
area. If this is not possible, an additional measurement error of
±2% of reading can occur.
4. Avoid taking measurements close to other current-carrying
conductors if possible.
5. Make sure that the arrow marked on the probe coupling points
toward the correct orientation for correct phase display on the
instrument. See also the setup screen of the instrument.
6. Keep the probe coupling more than 2.5 cm (1 inch) away from
the conductor.
7. Observe the current value and waveform on the instrument’s
display.
8. Observe the safety instructions when applying and using the
i430-Flexi-TF.
Warning
If the selected current probe of the Fluke 430 series
Power Quality Analyzer is not the i430-Flexi-TF, the
Fluke 430 will display false and misleading readings.
Maintenance
Before each use, assure continued safety by inspecting the flexible
probe and its latching system for any damage. Pay particular
attention to the insulation surrounding the flexible probe. An i430-
Flexi-TF under warranty will be promptly repaired or replaced (at
Fluke's discretion) and returned at no charge.
Cleaning and Storage
•The flexible probe and its latching system require no special
care. Ensure that no foreign body obstructs the latching
mechanism.
•Clean the i430-Flexi-TF with a damp cloth and a mild
detergent. Do not use abrasives, solvents, or alcohol.
If your i430-Flexi-TF does not work
If the i430-Flexi-TF does not perform properly, use the following
steps to help isolate the problem:
•Inspect the coupling system for any damage. If any foreign
material is present, the coupling system will not close properly
and errors will result.
•Inspect the cable between the flexible probe and the Power
Quality Analyzer for any damage.
•Check if the i430-Flexi-TF is the selected current probe on the
Power Quality Analyzer (Clamp i430-Flexi-TF).
•Verify that the function and range selection on the Power
Quality Analyzer is correct.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com