Ti10, Ti25, TiR and TiR1 Users Manual Supplement
12/07 1
Change #1
On page 2, add the following under the Warning:
To avoid injury from explosion, chemical burns,
or fire, follow all battery care and charging
instructions in this manual.
On page 3, under Unpacking the Imager, following the last
bullet add:
Note
Fluke recommends the use of the supplied SD
memory card with your thermal imager, and does
not warrant the use or reliability of aftermarket SD
memory cards of different brands or capacities.
On page 3, prior to step 1, add the following:
WCaution
To avoid damage to the Imager, remove it from
the DC car charger before starting or jump
starting the vehicle.
Note
Ensure the Imager is near room temperature before
connecting it to the charger. See the charging
temperature specification. Do not charge the camera in
hot or cold places. Charging in extreme temperatures
reduces the battery pack’s ability to hold a charge.
At the end of the “Charging the Battery” section, add the
following:
Keep the Imager attached to the charger until the battery condition
icon indicates a full charge. With the Imager off, the battery charge
icon will have four full bars. With the Imager on, turn the Imager off

Manual Supplement Ti10, Ti25, TiR and TiR1 Users
2 12/07
to view the battery condition icon. Removing the Imager from the
charger before a full charge is indicated will deprive the battery of a
full charge and thus shorten camera run time.
Note
New batteries are not fully charged. Two to ten
normal charging/discharging cycles may be
required before the battery charges to its maximum
capacity.
On page 15, before the General Specifications section,
insert the following:
Maintenance
The Imager is designed to provide maintenance free operation.
However, some precautions should be followed to get the best
and longest Imager performance.
Cleaning the Imager
Wipe the case with a damp cloth and a mild detergent. Do not
use abrasives, isopropyl alcohol, or solvents to clean the case or
lens/window.
Battery Care
To get the best performance from the Imager’s Nickel-Metal
Hydride (NiMH) battery, follow the guidelines listed below.
WCaution
To avoid damage to the Imager, do not
leave the camera exposed to a heat source
or high-temperature environment, such as
in the sun in an unattended vehicle.
•Do not store the Imager on the charger for more than 24
hours, or reduced battery life may result.

Ti10, Ti25, TiR and TiR1 Users Manual Supplement
12/07 3
•Charge the Imager for a minimum of 2 hours at least
every six months to maximize battery life. Without use,
the battery will self-discharge in approximately six
month. Batteries stored for long periods may require
two to ten charging cycles before the battery reaches
full capacity.
•Always operate the Imager within the temperature
range specified in the specifications labeled
Temperature – Operating.
~W Caution
Do not incinerate the Imager and/or battery.
Go to Fluke’s website for recycling
information.
Under General Specifications, Temperature add:
Charging………………0 °C to 40 °C (32 °F to 122 °F)