QuickStart FLUKE Series Ti450 SF6
Gas Detection Operation Only
1. MEMORY: Insert SD memory card into the slot under the rubber cover on the side of the camera.
2. POWER: Insert a fully charged battery into the base of the hand grip. The battery life is indicated in the lower left
corner of the LCD display. You can also press and hold the battery symbol on the side of the battery.
3. START: Press the Power button until you hear an audible tone signaling camera startup.
• Swing the attached lens cover up and lock in the open position on the top of the camera.
• The LCD display will turn on and you will see the default start up screen (as above) showing a live infrared image.
•Toturnthecamerao,pressthePowerbuttonuntilanaudibletonesignalsitispoweringdown.
4. FOCUS:Focusiseithermanualorautomatic,andisuserselectable(automaticrecommendedforSF6gas modes).
•Tomanuallyfocus,adjustthefocusingringeitherclockwiseorcounterclockwisetooptimizeimagefocus.
•Automaticfocusislaserenhanced.Toutilizethelaserassistedautofocus,depressthelaserassistedfocustrigger
whileaimingthelaserpointerattheobjectofinterest.Whileholdingthecamerasteady,releasethetrigger.Ifthere
istoomuchmovementofthelaserduringtheautofocusingoperation,anExcessiveLaserMovementwarningmay
appear on the screen.
5. PALETTE:Fromthehomescreen,depresstheF2button.Thenusingeitherthedirectionalarrowbuttonsorthe
touchscreen,selectImage,thenselectPalette.SelectSetPalette,andthenusingeithertheup/downdirectionalarrow
buttonsorthetouchscreenscrollthroughthepaletteselections.Toselectaparticularpalette,eitherdepresstheF1
button (done) twice or click the selection on the touch screen and then select Done.
6. IR Fusion:Fromthehomescreen,depresstheF2button.Thenusingeitherthedirectionalarrowbuttonsorthe
touchscreen,selectImage,thenselectIR-Fusion.ForfullscreenIRonlygasImagingselectIR 100%. For Picture
inPicture(IRwithinvisualimaging)andthenusingeithertheup/downdirectionalarrowbuttonsorthetouchscreen
scroll through the selections and select PIP 100%.Noteitnotrecommendedtoselectany%otherthan100%.Only
select Visual if you need to obtain visual orientation of the camera.
ACPower,USB,
MiniUSB
Laser Assisted
Focus Trigger
Trigger
(Pause Image)
Battery
FocusRing
MemoryCardSlot,
HDMI
F1,F2,F3
Buttons
Auto/Manual
Indicator
Power
Mic Speaker
Directional Arrow Keys

© 2018 The Snell Group / 322 N. Main St. / Suite 8 / Barre, VT 05641 / 800.636.9820 / www.thesnellgroup.com
7. SF6GAS MODEFromthehomescreen,depresstheF2
button. Then using either the directional arrow buttons or the
touchscreen,selectSF6Gas Detection Mode,thenselectSF6
Gas Detection Mode On.
8. SF6HIGH GAIN or LOW GAIN: For larger leaks under
ideal conditions you may select Low Gain (Handheld)Mode.For
small leaks or under less than ideal conditions tripod mount the
camera and select High Gain (Tripod)Mode.
9. SF6VIDEO or IMAGE CAPTURE MODE: In SF6menu
select either Image Capture to set the recording mode to record
a single still image or Video Capture to set the recoding mode to
recordavideosequence.SeeParagraphs10and11toinitiate
recording.
10. SINGLE IMAGE RECORDING:WhenthecamerahasbeensettoImageCaptureMode,liveimagesarepaused
bydepressingthegreentriggeronce.Onceanimagehasbeenpaused,theoptionsaregiventoSave,Edit or Cancel.
Selecting Cancelreturnstheimagertoliveoperation.Tosavetheimage,eitherdepresstheF1buttonorselectSave
on the touch screen. Select Edittoaddanaudioclip,aphoto-noteorchangepalette,orimagefusionmodebefore
saving the image.
11. VIDEO IMAGE RECORDING: WheninSF6video image recording mode image recording is started depressing
the green trigger once to prepare to start recording (timer reads 00:00) and then a second time to actually start re-
cordingThetimerwillstartadvancingonesecondatatime.Tostoporpauserecordingpressthegreentrigger.Once
paused,theoptionsaregiventoDone or Cancel. To continue recording press the green trigger. To save the recoding
press Done and then press Save.SelectingcancelwilltakeyoutoaconrmationmenutoCancel the recording and
Lose Video.
12. RECALL A STILL IMAGE:DepresstheF2button,andeitherusingthedirectionalbuttons(<and>)orbyinterfac-
ingthetouchscreen,selectMemory.IntheMemorymenu,usethedirectionalbuttonsortouchscreentoselectan
image with an .IS2leextension,theneitherdouble-clickontheimageviathetouchscreenorselectOKtoopenthe
selectedimage.PressF2BacktoreturntothememoryMenuorF3Cancel to return live.
13. RECALL A VIDEO:DepresstheF2button,andeitherusingthedirectionalbuttons(<and>)orbyinterfacingthe
touchscreen,selectMemory.IntheMemorymenu,usethedirectionalbuttonsortouchscreentoselectanimage
with an .IS3leextension,theneitherdouble-clickontheimageviathetouchscreenorselectOKtoopentheselect-
edimage.Avideosequencewillberecalledandthevideomenuwillappear.PressF2Back to return to the memory
MenuorF3Cancel to return live.
IFOV =1.31 mRad (Theoretical with 320 x 240 Detector and standard 24˚x17˚ lens)
IFOV =0.63 mRad (Theoretical with 320 x 240 Detector and standard 11.5˚x8.7˚ lens)
Detect 1in. target @ 64ft.
Detect 1in. target @ 132ft.
Ti-450 SF6with Standard Lens
Ti-450 SF6with Tele2 Lens