www.fmiproducts.com 124465-01B6
([KDXVWIDQV¿UHSODFHVFORWKHVGU\HUVDQG
IXHO EXUQLQJ DSSOLDQFHV GUDZ DLU IURP WKH
KRXVHWRRSHUDWH<RXPXVWSURYLGHDGHTXDWH
IUHVKDLUIRUWKHVHDSSOLDQFHV7KLVZLOOLQVXUH
proper venting of vented fuel-burning appli-
ances.
3529,',1*$'(48$7(
9(17,/$7,21
7KHIROORZLQJDUHH[FHUSWVIURP1ational Fuel
Gas Code. ANSI Z223.1/NFPA 54, Air for
Combustion and Ventilation.
All spaces in homes fall into one of the three
IROORZLQJYHQWLODWLRQFODVVL¿FDWLRQV
1. Unusually Tight Construction
8QFRQ¿QHG6SDFH
&RQ¿QHG6SDFH
7KH LQIRUPDWLRQ RQ SDJHV WKURXJK ZLOO
help you classify your space and provide
DGHTXDWHYHQWLODWLRQ
8QXVXDOO\7LJKW&RQVWUXFWLRQ
7KHDLUWKDWOHDNVDURXQGGRRUVDQGZLQGRZV
may provide enough fresh air for combustion
DQGYHQWLODWLRQ+RZHYHULQEXLOGLQJVRIXQ-
XVXDOO\WLJKWFRQVWUXFWLRQ\RXPXVWSURYLGH
additional fresh air.
8QXVXDOO\WLJKWFRQVWUXFWLRQLVGH¿QHGDV
construction where:
D ZDOOVDQGFHLOLQJVH[SRVHGWRWKHRXW-
VLGH DWPRVSKHUH KDYH D FRQWLQXRXV
ZDWHU YDSRU UHWDUGHU ZLWK D UDWLQJ RI
RQHSHUP[-11NJSHUSDVHFP2RU
OHVVZLWKRSHQLQJVJDVNHWHGRUVHDOHG
and
E ZHDWKHUVWULSSLQJKDVEHHQDGGHGRQ
RSHQDEOHZLQGRZVDQGGRRUVand
F FDXONLQJ RU VHDODQWV DUH DSSOLHG WR
DUHDV VXFK DV MRLQWV DURXQG ZLQGRZ
DQGGRRUIUDPHVEHWZHHQVROHSODWHV
DQGÀRRUVEHWZHHQZDOOFHLOLQJMRLQWV
EHWZHHQ ZDOO SDQHOV DW SHQHWUDWLRQV
IRUSOXPELQJHOHFWULFDODQGJDVOLQHV
DQGDWRWKHURSHQLQJV
If your home meets all of the three criteria
DERYH\RXPXVWSURYLGHDGGLWLRQDOIUHVKDLU
See Ventilation Air From OutdoorsSDJH
If your home does not meet all of the three
FULWHULD DERYH SURFHHG WR Determining
Fresh-Air Flow For Heater Location
CRQ¿QHG6SDFHDQG8QFRQ¿QHG6SDFH
The National Fuel Gas Code ANSI Z223.1/
NFPA 54GH¿QHVDFRQ¿QHGVSDFHDVDVSDFH
ZKRVHYROXPHLVOHVVWKDQFXELFIHHWSHU
AIR FOR COMBUSTION AND VENTILATION
Continued
%WXSHUKRXUP3SHUNZRIWKHDJ-
gregate input rating of all appliances installed
LQWKDWVSDFHDQGDQXQFRQ¿QHGVSDFHDVD
VSDFHZKRVHYROXPHLVQRWOHVVWKDQFXELF
IHHWSHU%WXSHUKRXUP3SHUNZ
of the aggregate input rating of all appliances
installed in that space. Rooms communicating
GLUHFWO\ZLWKWKHVSDFHLQZKLFKWKHDSSOLDQFHV
DUHLQVWDOOHGWKURXJKRSHQLQJVQRWIXUQLVKHG
ZLWKGRRUVDUHFRQVLGHUHGDSDUWRIWKHXQ-
FRQ¿QHGVSDFH
* Adjoining rooms are communicating only if
WKHUHDUHGRRUOHVVSDVVDJHZD\VRUYHQWLODWLRQ
JULOOVEHWZHHQWKHP
DETERMINING FRESH-AIR FLOW
)25),5(3/$&(/2&$7,21
'HWHUPLQLQJLI<RX+DYHD&RQ¿QHGRU
8QFRQ¿QHG6SDFH
8VHWKLVZRUNVKHHWWRGHWHUPLQHLI\RXKDYH
DFRQ¿QHGRUXQFRQ¿QHGVSDFH
6SDFH,QFOXGHVWKHURRPLQZKLFK\RXZLOOLQVWDOO
¿UHSODFH SOXV DQ\ DGMRLQLQJ URRPV ZLWK GRRU-
OHVVSDVVDJHZD\VRUYHQWLODWLRQJULOOVEHWZHHQ
the rooms.
1. Determine the volume of the space (length
[ZLGWK[KHLJKW
Length x Width x Height =__________cu. ft.
(volume of space)
Example:6SDFHVL]HIWOHQJWK[IW
ZLGWK[IWFHLOLQJKHLJKW FXIW
(volume of space)
If additional ventilation to adjoining room
LVVXSSOLHGZLWKJULOOVRURSHQLQJVDGGWKH
volume of these rooms to the total volume
of the space.
2. Multiply the space volume by 20 to determine
the maximum Btu/Hr the space can support.
________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
Example: FX IW YROXPH RI VSDFH [
PD[LPXP%WX+UWKHVSDFHFDQ
support)
3. Add the Btu/Hr of all fuel burning appliances
in the space.
9HQWIUHH¿UHSODFH_________ Btu/Hr
*DVZDWHUKHDWHU_________ Btu/Hr
Gas furnace _________ Btu/Hr
Vented gas heater _________ Btu/Hr
*DV¿UHSODFHORJV_________ Btu/Hr
Other gas appliances* + _________ Btu/Hr
Total = _________ Btu/Hr
* Do not include direct-vent gas appliances.
'LUHFWYHQWGUDZV FRPEXVWLRQ DLUIURP WKH
outdoors and vents to the outdoors.