SHAVER INTERFACE
PRESSURE CYCLE
A. Connecting the One Day Set Irrigation Tube
Quick Setup Guide ( Using Irrigation Tube as "One Day Set"*)
1
2
3
a
g
b
c
d
e
f
Fill
Chamber
G
Advance d Irrigation Pump
®
I
R
R
I
G
A
T
I
O
N
Fill
Chamber
Advanced Irrigation Pump
®
I
R
R
I
G
A
T
I
O
N
a
a
a
b
Fill
Chamber
Advanced Irrigation Pum p
®
I
R
R
I
G
A
T
I
O
N
c
d
4
INPUT POWER:
0197
IP54
TYPE B
CLASS I
REPLACE FUSES AS MARKED
120/230V~50-60Hz
500VA
C
ab
a: Connect the pressure transducer tube into the fill
chamber port. Turn clockwise until snug.
b: Turn pump on by pressing Iswitch on back.
c: Close lid and press POWER STAND-BY button.
d: Remove caps off irrigation spikes.
5a: Insert spikes into irrigation bags.
b: Open two (2) clamps on One Day Set irrigation tubes.
c: Press RUN STOP button. Prime pump to fifty (50).
d: Press FI CHAMBER button to pump fluid into the
chamber. Repeat until fluid rises to indicator window
(1/3 full).
e: Twist cap off One Day Set irrigation tube.
Fill
Chamber
RUN/STOP
Pressure Cycle
R
PRESSURE
ALARM
Advanced Irrigation Pump
®
pressure
Run
Stop
b
c
a
Fill
Chamber
RUN/STOP
Pressure Cycle
Remote
Control
PRESSURE
ALARM
Advanced Irrigation Pump
®
pressure
Run
Stop
a: ift lids and roller arm, then slide the green part of
the tube into the auto-locking feature on the pump.
b: Place and center the tube around the roller. Pull
on the tube and close the tension rocker arm
against the tube.
c: Position the pressure chamber in the holder.
d: Twist cap off of the pressure transducer tube.
a: Remove One Day Set irrigation tube
from the package and close three (3)
white clamps on the One Day Set
irrigation tube.
1a: Remove the intermediary irrigation tube
with one-way valve from the package and
close the white clamp.
b: Tighten white-blue connector on
the intermediary irrigation tube.
c: Twist blue cap off the intermediary
irrigation tube.
a: Insert power cable into socket.
b: Attach the foot pedal connector
to the port.
c: Attach shaver interface connector
to the port.
d: Insert power cable into interface cable.
e: Connect interface cable to shaver box.
f: Connect shaver to interface cable.
g: Insert power cables into wall socket.
Fill
Chamber
RUN/STOP
Pressure Cycle
R
PRESSURE
ALARM
Advanced IrrigationPump
®
pressure
Run
Stop
®
d
c
d
e
3a: Connect the tube marked INF OW to the arthroscopic
scope sheath.
2a: Connect the One Day Set irrigation tube to the
intermediary irrigation tube with one-way valve
by screwing the two blue connector ends together
until snug.
b: Open both clamps until fluid exits the tube. Close
the clamp nearest the end of the tube after fluid
is released and place in the sterile field.
c
fms solo®
B. Connecting the Intermediary Irrigation Tube (with One-way Valve)
a
b
INFLOW
RUN/STOP
Pressure Cycle
Remote
Control
PRESSURE
A
pressure
Run
Stop
Chamber
b
a
*"One Day Set" allows rr gat on tub ng to be used for up to e ght hours.
C. Set up for next operation
1a: If other surgeries are scheduled for the same operating
day, disconnect the blue luer lock of the intermediary
tubing and leave the one-way valve attached to the
irrigation tubing at the end of each surgery.
2a: At the start of a new surgery remove the old one-way valve.
b: IMMEDIATE Y connect the blue luer lock of the NEW patient
set intermediary tubing with one-way valve to the blue luer
lock of the One Day Set irrigation tubing.
c: WARNING! Never attach a one-way valve to another.
abc
a
a