Fortek Security Systems ST1 Quick start guide

V2.30 Feb, 2018
ST1 Operational Manual
Keyless Access System Solutions

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
2
System Setup
When the system is powered for the first time the green and orange light will be
blinking simultaneously indicating that initial setup is required. Make sure to have
the access credentials (keyfobs, access cards, cellphone tags) you want to enroll.
The system can function on three different operational modes,
Setup instructions:
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password. The factory default password is “1234”. The green light will
Blink twice if the correct password was entered.
C) Enter the system application mode:
To select Operational Mode 1: Press key: “1”
To select Operational Mode 2: Press key: “2”
To select Operational Mode 3: Press key: “3”
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
Important Note: We recommend to change the default password ‘1234’(function#10 - described
in the manual) and default controller reset key ‘4812446’(function #6 - described in the manual)
ST1 Operative Manual
Manual for operational mode 1 ----- Page 3 -8
Manual for operational mode 2 ----- Page 9-16
Manual for operational mode 3 ----- Page 17-22
Operational Mode 1: One (1) door access control application
Operational Mode 2: Two (2) doors access control application (enrolled
credentials will unlock both doors)
Operational Mode 3: Two (2) doors access control application with
independent door settings. Enrolled credentials can be set to unlock door
number one (1), door number two (2), or both doors.

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
3
1. Enroll a single credential: To incorporate a new credential to the system.
2. Enroll multiples credentials: To incorporate a number of credentials to the system.
3. Delete a credential: To delete a credential in order to prevent unwanted access.
4. Replace a credential: To delete a lost or stolen credential and enroll a new one.
5. Door monitor activation/deactivation: Security feature that provides a continuous warning
signal if the door remains open. Door contact installation is required in order to utilize this
feature.
6. Change controller reset Key: This function allows to setup a unique and easy to
remember reset key for the controller –the controller reset key is used to reset the security
password or reset the controller to manufacturer original settings.
7. Unlocked mode: To keep the door unlocked to grant access to visitors or people who do not
have a credential.
8. Locked mode: To switch-back from open mode (7) to normal mode (credential holder only)
9. Unlocking time set: To set the number of seconds that the door will remain unlocked after
presenting the credential onto the proximity reader.
10. Password change: To change the actual security password to a new one.
11. Password reset: To reset the security password back to the default one ‘1234’.
12. System reset: To delete all existent users and settings. The system will be back to the factory
settings.
System functions - Operational Mode 1

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
4
1 - Enroll a single credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if
the correct password was entered.
C) Press key number one "1" to enter to the "enroll single credential mode", the green light will
blink once and remain on to indicate that the new credential has to be presented onto the
reader
D) Present the new credential over the proximity reader, if the operation was successful the light
on the reader will blink twice, turning from red to green, indicating the credential was
successfully incorporated into the system. The system will exit the programming mode
automatically.
Note 1: The last 4 digits printed on the credential is automatically stored into the system, allowing
future deletion or replacement if necessary. (Software provided to keep track of users and assigned
credentials)
Note 2: Upon attempt to enrolling an already existent credential the light on the reader will remain
green for 10 seconds and the controller will emit a warning beeping 5 times.
2- Enroll multiple credentials
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if
the correct password was entered.
C) Press key number one "0" to enter to the "enroll multiple credentials mode", the green light
will blink once and remain on to indicate that new credentials have to be presented on the
reader.
D) Present the new credentials onto the reader consecutively, after each credential is presented,
the light on the reader will blink twice, turning from red to green indicating the credential was
successfully incorporated into the system.
E) To finish the operation press and hold the Escape key "ESC" until double beep is heard, the
orange and green light will be turn off indicating that the system exited the programming mode.
Note 1: The last 4 digits printed on the credentials are automatically stored into the system,
allowing future deletion or replacement if necessary. (Software provided to keep track of users and
assigned smart keys)
Note 2:Upon attempt to enrolling an already existent credential the light on the reader will remain
green for 10 seconds and the controller will emit a warning beeping 5 times.
Keypad Instructions - Operational Mode 1

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
5
3 - Delete a credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if
the correct password was entered.
C) Press key number two "2" to enter to the "delete credential mode", the green light will blink
once.
D) Enter the last four (4) digits of the credential you want to delete
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
4 - Replace a credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered the programming mode.
B) Enter the 4 digit security password –factory default:1234.. The green light will blink twice
if the correct password was entered.
C) Press key number three "3" to enter to the "replace credential mode", the green light will
blink once.
D) Enter the last four (4) digits of the credential you want to replace
If the deletion was successful, the system will beep twice; the green light will blink once and will
remain on indicating that the new credential has to be presented on the reader.
E) Present the new credential over the proximity reader, if the operation is successful the light on
the reader will blink twice, turning from red to green, indicating the credential was successfully
incorporated into the system.
5 - Door monitor activation/deactivation (door contact installation required)
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if
the correct password was entered.
C) Press key number four "4" to enter the "door monitor activation/deactivation”command. If
the door monitor was deactivated it will activate it, if it was activated it will deactivate it. If the
operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
6
6 –Change controller reset key
The controller comes with a default 7 digits reset key ‘4812446’used to reset the system to
manufacturer settings, and also used to reset the 4 digits security password to the default ‘1234’
(useful in cases where the security password is forgotten). This function allows to overwrite the
default reset key by setting up your unique and easy to remember 7 digits reset key.
A) Press and hold the Escape key "ESC" until a double beep is heard.
The orange light will remain on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number five "5" to enter the "change controller reset key" command.
D) Enter your new 7 digits reset key (0-9 digit allowed).
If the operation was successful, the system will beep twice and the green light will remain ON
for 3 seconds.
7 - Unlocked Mode
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit password. The green light will blink twice if the correct password was entered.
C) Press key number six "6" to enter the "unlocked mode" command.
If the operation was successful, the system will beep twice and the green light will blink once and
remain ON indicating that door/s remain unlocked
8 - Locked Mode
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number seven "7" to enter the "locked mode" command.
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
7
9 - Unlocking time set
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password.. The green light will blink twice if the correct password
was entered.
C) Press key number eight "8" to enter to the "unlocking time set mode" the green light will
blink once.
D) Enter the number of seconds you want the door to remain unlocked after the credentials are
presented on the reader, accepted values are between two and nine (2-9).
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
10 - Change Password
A) Press and hold the Escape key [ESC] until a double beep is heard. The orange light will
remain on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number nine "9"to enter to the "password change" operation mode, the green light
will blink once.
D) Enter the four digits of the new password (0-9 digit allowed).
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
11 - Password Reset
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Press Enter "ENT" key, the green light will blink once.
C) Press key number seven "7" to enter to the “password reset mode”, the green light will blink
once.
D) Enter the factory default ‘4812446’or your unique 7 digits controller reset key.
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
After this operation, the password will be reset to “1234”

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
8
12 –System Reset
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Press Enter "ENT" key, the green light will blink once.
C) Press key number nine "9" to enter to the "system reset" operation mode, the green light will
blink once.
D) Enter the factory default ‘4812446’or your unique 7 digits controller reset key.
. If the operation was successful, the system will beep twice and the green light will remain ON for
3 seconds.
Once the operation is completed, all the users and settings will be deleted, the password will be
reset to “1234”; and the system will be reset to factory settings.
Security features and error signals:
Upon entering a wrong command key the system will beep once, the orange light will blink
once and remain off indicating that the system exited the programming mode
Upon thirty five seconds(35)of idle time between commands the system will beep once, the
orange light will blink once and remain off indicating that the system exited the
programming mode
After three (3) failed attempts of entering the security password the system will be blocked
for 5 minutes, during that time it will not be possible to enter into the programming mode.
Upon attempt to enroll an already existent credential the light on the reader will remain
green for 10 seconds and the controller will beep 7 times.
Upon attempt to enroll more than one thousand to hundred and sixty(1.260) credentials the
light on the readers will blink for 20 seconds and the orange and green light will turn off
indicating the system exited the programming mode.
To exit the programming mode at any time press escape key “ESC”

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
9
1. Enroll a single credential: To incorporate a new credential to the system.
2. Enroll multiple credentials: To incorporate a number of credentials to the system.
3. Delete a credential: To delete a credential in order to prevent unwanted access.
4. Replace a credential: To delete a lost or stolen credential and enroll a new one.
5. Door monitor activation/deactivation: Security feature that provides a continuous warning
signal if the door remains open. Door contact installation is required in order to utilize this
feature.
6. Change controller reset Key: This function allows to setup a unique and easy to
remember reset key for the controller –the controller reset key is used to reset the security
password or reset the controller to manufacturer original settings.
7. Unlocked mode: To keep the door/s unlocked to grant access to visitors or people who do not
have a credential.
8. Locked mode: To switch-back from open mode (7) to normal mode (credential holder only)
9. Unlocking time set: To set the number of seconds that the door will remain unlocked after
presenting the credential onto the proximity reader.
10. Password change: To change the actual password to a new one.
11. Password reset: To reset the password back to the default “1234”.
12. Independent doors settings: To switch the system from Mode 2(enrolled credentials unlock
both doors) to Mode 3 (enrolled credentials can be set to unlock door number 1, door number 2
or both). credentials stored into the system will remain with the same settings.
13. System reset: To delete all existent users and settings. The system will be back to the factory
settings.
System functions - Operational Mode 2

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
10
1 - Enroll a single credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number one "1" to enter to the "enroll single credential mode", the green light will
blink once and remain on to indicate that the new credential has to be presented on any on the
two proximity readers.
D) Present the new credential over a proximity reader, if the operation was successful the light on
The reader will blink twice, turning from red to green, indicating the credential was successfully
incorporated into the system. The system will exit the programming mode automatically.
Note 1: The last 4 digits printed on the credential are automatically stored into the system,
allowing future deletion or replacement if necessary. (Software provided to keep track of users and
assigned credentials)
Note 2: Upon attempt to enrolling an already existent credential the light on the reader will remain
green for 10 seconds and the controller will provide a warning beeping 5 times.
2- Enroll multiple credentials
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number one "0" to enter to the "enroll multiple credentials mode", the green light
will blink once and remain on to indicate that new credentials have to be presented on the any
on the two readers.
D) Present the new credentials over a proximity reader consecutively, after each credential is
presented. the light on the reader will blink twice, turning from red to green indicating the
credential was successfully incorporated into the system.
E) To finish the operation press and hold the Escape key "ESC" until double beep is heard, the
orange and green light will be turn off indicating that the system exited the programming mode.
Note 1: The last 4 digits printed on the credential are automatically stored into the system,
allowing future deletion or replacement if necessary. (Software provided to keep track of users and
assigned credentials)
Note 2: Upon attempt to enrolling an already existent credential the light on the reader will remain
green for 10 seconds and the controller will provide a warning beeping 5 times.
Keypad Operation Instructions –Operational Mode 2

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
11
3 - Delete a credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
onto indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number two "2" to enter to the "delete credential mode", the green light will blink
once.
D) Enter the last four (4) digits of the credential you want to delete
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
4 - Replace a credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number three "3" to enter to the "replace credential mode", the green light will
blink once.
D) Enter the last four (4) digits of the credential you want to replace
If the deletion was successful, the system will beep twice; the green light will blink once and will
remain on indicating that the new credential has to be presented on the reader.
E) Present the new credential over the reader, successful the light on the reader will blink twice,
turning from red to green, indicating the credential was successfully incorporated into the
system.
5 - Door monitor activation/deactivation (door contact installation required)
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number four "4" to enter the "door monitor activation/deactivation”command. If
the door monitor was deactivated it will activate it, if it was activated it will deactivate it. If the
operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
12
6 –Change controller reset key
The controller comes with a default 7 digits reset key ‘4812446’used to reset the system to
manufacturer settings, and also used to reset the 4 digits security password to the default ‘1234’
(useful in cases where the security password is forgotten). This function allows to overwrite the
default reset key by setting up your unique and easy to remember 7 digits reset key.
A) Press and hold the Escape key "ESC" until a double beep is heard.
The orange light will remain on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number five "5" to enter the "change controller reset key" command.
D) Enter your new 7 digits reset key (0-9 digit allowed).
If the operation was successful, the system will beep twice and the green light will remain ON
for 3 seconds.
7 - Unlocked Mode
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit password. The green light will blink twice if the correct password was entered.
C) Press key number six "6" to enter the "unlocked mode" command.
D) Enter the door number you want to unlock,
Enter “1” to unlock door number 1
Enter “2” to unlock door number 2
Enter “3” unlock both doors
If the operation was successful, the system will beep twice and the green light will blink once and
remain ON indicating that door/s remain unlocked

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
13
8 - Locked Mode
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number seven "7" to enter the "locked mode" command.
D) Enter the door number you want to lock (credential access only),
Enter “1” to lock door number 1
Enter “2” to lock door number 2
Enter “3” to lock both doors
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
9 - Unlocking time set
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number eight "8" to enter to the "unlocking time set mode" the green light will
blink once.
D) Enter the number of seconds you want the door to remain unlocked after the credentials are
presented on the reader, accepted values are between two (2) and nine (9) seconds.
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
10 - Change Password
A) Press and hold the Escape key [ESC] until a double beep is heard. The orange light will
remain on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was
entered.
C) Press key number nine "9"to enter to the "password change" operation mode, the green light
will blink once.
D) Enter the four digits of the new password (0-9 digit allowed).
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
14
11- Reset Password
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Press Enter "ENT" key, the green light will blink once.
C) Press key number seven "7" to enter to the “password reset mode”, the green light will blink
once.
D) Enter the factory default reset key ‘4812446’or your unique 7 digits controller reset key.
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds. After this operation, the password will be reset to “1234”
12 –Independent door Set/Unset (Switch mode 2-->mode 3)
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Press Enter "ENT" key, the green light will blink once.
C) Press key number nine "8" to enter to the "independent doors" operation mode, the green
light will blink once.
D) Enter the seven unique digit password provided with the access system controller. If the
operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
Once the operation is completed, when new credentials are enrolled, it will be required to define
authorized door/s number (Mode3). Please from this moment refer to operational instruction for
mode 3 to perform management operations
13 –System Reset
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Press Enter "ENT" key, the green light will blink once.
C) Press key number nine "9" to enter to the "system reset" operation mode, the green light will
blink once.
D) Enter the factory default reset key ‘4812446’or your unique 7 digits controller reset key.
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
Once the operation is completed, all the users and settings will be deleted, the password will be
reset to “1234”; and the system will be reset to factory settings.

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
15
Security features and error signals:
Upon entering a wrong command key the system will beep once, the orange light will blink
once and remain off indicating that the system exited the programming mode
Upon thirty five seconds(35)of idle time between commands the system will beep once, the
orange light will blink once and remain off indicating that the system exited the
programming mode
After three (3) failed attempts of entering the security password the system will be blocked
for 5 minutes, during that time it will not be possible to enter into the programming mode.
Upon attempt to enroll an already existent credential the light on the reader will remain
green for 10 seconds and the controller will beep 7 times.
Upon attempt to enroll more than one thousand to hundred and sixty(1.260) credentials the
light on the readers will blink for 20 seconds and the orange and green light will turn off
indicating the system exited the programming mode.
To exit the programming mode at any time press escape key “ESC”

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
16
1. Enroll/Edit a single credential:To incorporate a new credential into the system or modify
authorized door to an existent credential
2. Enroll/Edit multiple credentials:To incorporate a number of credentials into the system or
modify authorized doors to existent credentials
3. Delete a credential: To delete a credential in order to prevent unwanted access.
4. Replace a credential: To delete a lost or stolen credential and enroll a new one.
5. Door monitor activation/deactivation: Security feature that provides a continuous warning
signal if the door remains open. Door contact installation is required in order to utilize this
feature.
6. Change controller reset Key: This function allows to setup a unique and easy to
remember reset key for the controller –the controller reset key is used to reset the security
password or reset the controller to manufacturer original settings.
7. Unlocked mode:To keep the door/s unlocked to grant access to visitors or people who do not
have a credential.
8. Locked mode: To switch-back from open mode (7) to locked mode (credential holder only
access)
9. Unlocking time set: To set the number of seconds that the door will remain unlocked after
presenting the credential over the credential reader
10. Password change: To change the actual password to a new one.
11. Password reset: To reset the password back to the default one.
12. Independent readers set/unset: To switch the system to mode 3 to mode 2(two doors
access control where enrolled credentials unlock both doors)
13. System reset: To delete all existent users and settings. The system will be back to the factory
settings.
System Functions –Operational Mode 3

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
17
1 –Enroll/Edit a single credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number one "1" to enter to the "enroll single credential mode", the green light will
blink once and remain on to indicate that the new credential has to be presented on the reader
D) Enter the number of door you want to activate the credential on:
Enter “1” to enroll the credential to unlock door number 1
Enter “2” to enroll the credential to unlock door number 2
Enter “3” to enroll the credential to unlock both doors
Present the new credential over the reader (any of the two readers), if the operation was
successful the light on the reader will blink twice, turning from red to green, indicating the
credential was successfully incorporated into the system. The system will exit the programming
mode automatically.
Note 1:The last 4 digits printed on the credential are automatically stored into the system,
allowing future deletion or replacement if necessary. (Software provided to keep track of users and
assigned credentials)
Note 2:Upon attempt to enrolling an already existent credential with the same authorized door
the light on the reader will remain green for 10 seconds and the controller will provide a warning
beeping 7 times.
2- Enroll/Edit multiple credentials
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was
entered.
C) Press key number one "0" to enter to the "enroll multiple credentials mode", the green light
will blink once and remain on to indicate that new credentials have to be presented on the
reader.
D) Enter the number of door you want to authorize the access to:
Enter “1” to enroll the credentials to authorize unlocking door number 1
Enter “2” to enroll the credentials to authorize unlocking door number 2
Enter “3” to enroll the credentials to authorize unlocking both doors
Present the new credentials over the reader consecutively, after each credential is presented, the
light on the reader will blink twice, turning from red to green indicating the credential was
successfully incorporated into the system, if the credential was already in the system and it was set
with a different authorized door/s the modification will be made.
Keypad Operation Instructions –Operational Mode 3

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
18
F) To finish the operation press and hold the Escape key "ESC" until double beep is heard, the
orange and green light will be turn off indicating that the system exited the programming mode.
Note 1: The last 4 digits printed on the credential are automatically stored into the system,
allowing future deletion or replacement if necessary. (Software provided to keep track of users and
assigned credentials)
Note 2: Upon attempt to enrolling an already existent credential with the same authorized door
the light on the reader will remain green for 10 seconds and the controller will provide a warning
beeping 7 times.
3 - Delete a credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
onto indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number two "2" to enter to the "delete credential mode", the green light will blink
once.
D) Enter the last four (4) digits of the credential you want to delete
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
4 - Replace a credential
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number three "3" to enter to the "replace credential mode", the green light will
blink once.
D) Enter the last four (4) digits of the credential you want to replace. If the deletion was successful,
the system will beep twice.
E) Enter the number of door you want to activate the new credentials on:
Enter “1” to enroll the credentials to unlock door number 1
Enter “2” to enroll the credentials to unlock door number 2
Enter “3” to enroll the credentials to unlock both doors
The green light will blink once and will remain on indicating that the new credential has to be
presented on the reader.

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
19
F) Present the new credential over the reader, successful the light on the reader will blink twice,
turning from red to green, indicating the credential was successfully incorporated into the
system.
5 - Door monitor activation/deactivation (door contact installation required)
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number four "4" to enter the "door monitor activation/deactivation”command. If
the door monitor was deactivated it will activate it, if it was activated it will deactivate it.
If the operation was successful, the system will beep twice and the green light will remain ON for
3 seconds.
6 –Change controller reset key
The controller comes with a default 7 digits reset key ‘4812446’used to reset the system to
manufacturer settings, and also used to reset the 4 digits security password to the default ‘1234’
(useful in cases where the security password is forgotten). This function allows to overwrite the
default reset key by setting up your unique and easy to remember 7 digits reset key.
A) Press and hold the Escape key "ESC" until a double beep is heard.
The orange light will remain on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number five "5" to enter the "change controller reset key" command.
D) Enter your new 7 digits reset key (0-9 digit allowed).
If the operation was successful, the system will beep twice and the green light will remain ON
for 3 seconds.
7 - Unlocked Mode
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit password. The green light will blink twice if the correct password was entered.
C) Press key number six "6" to enter the "unlocked mode" command.
D) Enter the door number you want to unlock,
Enter “1” to unlock door number 1
Enter “2” to unlock door number 2
Enter “3” unlock both doors
If the operation was successful, the system will beep twice and the green light will blink once and
remain ON indicating that door/s remain unlocked

Fortek Security Systems
Tel: 1-800-505-6476 www.forteksecurity.com Fax: 1-866-655-6342
20
8 - Locked Mode
A) Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password
was entered.
C) Press key number seven "7" to enter the "locked mode" command.
D) Enter the door number you want to lock (credential access only),
Enter “1” to lock door number 1
Enter “2” to lock door number 2
Enter “3” to lock both doors
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
9 - Unlocking time set
A) Press and hold the Escape key "ESC" until a double beep is heard.
The orange light will remain on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was entered.
C) Press key number eight "8" to enter to the "unlocking time set mode" the green light will
blink once.
D) Enter the number of seconds you want the door to remain unlocked after the credentials are
presented on the reader, accepted values are between two (2) and nine (9) seconds.
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds.
10 –Change Password
A) Press and hold the Escape key [ESC] until a double beep is heard. The orange light will
remain on to indicate you have entered into the programming mode.
B) Enter the 4 digit security password –factory default:1234. The green light will blink twice if the
correct password was
entered.
C) Press key number nine "9"to enter to the "password change" operation mode, the green light
will blink once.
D) Enter the four digits of the new password (0-9 digit allowed).
If the operation was successful, the system will beep twice and the green light will remain ON for 3
seconds
Popular IP Access Controllers manuals by other brands

2N
2N Access Unit M installation manual

Honeywell
Honeywell ACS-8 installation instructions

Carrier
Carrier 30GT Series installation instructions

Motorline professional
Motorline professional MLS4 User& installer's manual

ACT Technology
ACT Technology ACT ACT1000 Operating & installation instructions

Progeny
Progeny P66 user guide

Metra Electronics
Metra Electronics ELDLISS user manual

Sygonix
Sygonix 2299889 operating instructions

Smarthome Group
Smarthome Group Bio-Eagle user manual

Mircom
Mircom TX3 Series installation manual

TransTel Communications
TransTel Communications IP3922 Series user manual

ZKTeco
ZKTeco KF1000 Series quick start guide