Four-Faith FAX03 User manual

FAX03 S eries
User Manual
D ocumentation No. Product Version Page
Product Name : Total:
FAX03
FAX03
FAX03
FAX03 LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal User
User
User
User Manual
Manual
Manual
Manual
The user manual is suitable for the following product model :
P roduct M odel Product Type
FA003 GSM LED Intelligent Terminal
FA103 GPRS LED Intelligent Terminal
FA203 CDMA LED Intelligent Terminal
FA303 EDGE LED Intelligent Terminal
FA403 WCDMA LED Intelligent Terminal
FA503 TD-SCDMA LED Intelligent
Terminal
FA603 EVDO LED Intelligent Terminal
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,
Co.,
Co.,
Co., Ltd.
Ltd.
Ltd.
Ltd.
Add
Add
Add
Add :J1-J3,3rd
J1-J3,3rd
J1-J3,3rd
J1-J3,3rd Floor,No.44,GuanRi
Floor,No.44,GuanRi
Floor,No.44,GuanRi
Floor,No.44,GuanRi Road,SoftWare
Road,SoftWare
Road,SoftWare
Road,SoftWare
Park,XiaMen,China
Park,XiaMen,China
Park,XiaMen,China
Park,XiaMen,China Zip
Zip
Zip
Zip Code:361008
Code:361008
Code:361008
Code:361008
Tel
Tel
Tel
Tel :+86
+86
+86
+86 592-6300326
592-6300326
592-6300326
592-6300326 ,6300325
6300325
6300325
6300325 ,6300324
6300324
6300324
6300324
Fax:+86
Fax:+86
Fax:+86
Fax:+86 592-5912735
592-5912735
592-5912735
592-5912735
http://www.fourfaith.com
http://www.fourfaith.com
http://www.fourfaith.com
http://www.fourfaith.com

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 2 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www. f our f aith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
Files Revised Record
Date Version Remark Author

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 3 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www. f our f aith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
Copyright
Copyright
Copyright
Copyright Notice
Notice
Notice
Notice
A ll contents in the files are protected by copyright law, and all copyrights are reserved by Xiamen
Four-Faith Communication Technology Co., Ltd. Without written permission, all commercial
use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc.,
but non-commercial purpose, downloaded or printed by individual (all files shall be not revised,
and the copyright and other proprietorship notice shall be reserved) are welcome.
Trademark
Trademark
Trademark
Trademark Notice
Notice
Notice
Notice
Four-Faith 、四信、 、 、 are all registered trademarks of Xiamen
Four-Faith Communication Technology Co., Ltd., illegal use of the name of Four-Faith,
trademarks and other marks of Four-Faith is forbidden , unless written permission is authorized in
advance.

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 4 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www. f our f aith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 5 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www. f our f aith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
Contents
ContentsChapter 1 Brief Introduction of Product ............................................................................................ 6
1.1 General ................................................................................................................................ 6
1.2 Features and Benefits .......................................................................................................... 6
1.3 Working Principle ................................................................................................................ 7
1.4 Specifications ...................................................................................................................... 7
Chapter 2 Installation Introduction .................................................................................................. 10
2.1 General .............................................................................................................................. 10
2.2 Encasement List ................................................................................................................ 10
2.3 Installation and Cable Connection .................................................................................... 10
2.4 Power ................................................................................................................................. 12
2.5 Indicator Lights Introduction ............................................................................................. 12
Chapter 3 Configuration .................................................................................................................. 13
3.1 Configuration Connection ................................................................................................. 13
3.2 Configuration Introduction ................................................................................................ 13
3.3 Run the configure Tool:
IP
Modem Configure.exe ........................................................... 14
3.4 Re-power LED Intelligent Terminal .................................................................................. 14
3.5 Configuration .................................................................................................................... 15
3.5.1 Data Service Center Settings .................................................................................. 15
3.5.2 LED Intelligent Terminal Settings .......................................................................... 17
3.5.3 Other Settings ......................................................................................................... 23
3.6 Functions ........................................................................................................................... 26
3.7 Work State Switch ............................................................................................................. 27
Appendix ......................................................................................................................................... 28

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 6 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
C
C
C
C hapter
hapter
hapter
hapter 1
1
1
1 Brief
Brief
Brief
Brief Introduction
Introduction
Introduction
Introduction of
of
of
of Product
Product
Product
Product
1.1
1.1
1.1
1.1 General
General
General
General
FAX03 series LED Intelligent Terminal is a kind of cellular terminal device that provides
data transfer function by public cellular network.
It adopts high-powered industrial 16/32 bits CPU and embedded real time operating system .
It supports RS232 and RS485 (or RS422) port that can conveniently and transparently connect one
device to a cellular network, allowing you to connect to your existing serial devices with only
basic configuration.
It has been widely used on M2M fields, such as intelligent transportation, smart grid,
industrial automation, telemetry , finance, POS, water supply, environment protection, post,
weather, and so on.
1.2
1.2
1.2
1.2 Features
Features
Features
Features and
and
and
and Benefits
Benefits
Benefits
Benefits
Design
Design
Design
Design for
for
for
for Industrial
Industrial
Industrial
Industrial Application
Application
Application
Application
High-powered industrial cellular module
H igh-powered industrial 16/32 bits CPU
Support low-consumption mode , including sleep mode , scheduled online/offline mode,
scheduled power-on/power-off mode ( optional )
Housing: iron, providing IP30 protection.
Power range: DC 5~35V
S
S
S
S tability
tability
tability
tability and
and
and
and R
R
R
R eliability
eliability
eliability
eliability
Support hardware and software WDT
Support auto recovery mechanism, including online detect, auto redial when offline to make
it always online
RS232/RS485/RS422 port: 15KV ESD protection
SIM/UIM port: 15KV ESD protection
Power port: reverse-voltage and overvoltage protection
Antenna port: lightning protection(optional)
Standard
Standard
Standard
Standard and
and
and
and Convenience
Convenience
Convenience
Convenience
Support standard RS232 and RS485(or RS422) port that can connect to serial devices directly

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 7 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
Support intellectual mode, enter into communication state automatically when powered
Provide management software for remote management
Support several work modes
Convenient configuration and maintenance interface
H
H
H
H igh-performance
igh-performance
igh-performance
igh-performance
Support TCP server and support multi TCP client connection(optional)
Support double data centers, one main and another backup
Support multi data centers and i t can support 5 data centers at the same time
Support multi online trigger ways, including SMS, ring and data. Support link disconnection
when timeout
Support dynamic domain name(DDNS) and IP access to data center
Design with standard TCP/IP protocol stack
Support APN/VPDN
1.3
1.3
1.3
1.3 Working
Working
Working
Working Principle
Principle
Principle
Principle
The principle chart of the LED Intelligent Terminal is as following:
1.4
1.4
1.4
1.4 Specification
Specification
Specification
Specification s
s
s
s
Cellular
Cellular
Cellular
Cellular Specification
Specification
Specification
Specification
Standard
Standard
Standard
Standard and
and
and
and Band
Band
Band
Band Bandwidth
Bandwidth
Bandwidth
Bandwidth TX
TX
TX
TX power
power
power
power RX
RX
RX
RX
sensitivity
sensitivity
sensitivity
sensitivity
FA
FA
FA
FA 10
10
10
10 3
3
3
3 GPRS
GPRS
GPRS
GPRS LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal
EGSM900/GSM1800MHz,
GSM850/900/1800/1900MHz(optional)
Compliant to GSM phase 2/2+
GPRS class 10 , class 12(optional)
85.6Kbps GSM850/900 :
<33dBm
GSM1800/1900
:
<30dBm
<-107
dBm
E mbedded processing
system
Cellular Module
Power
RS232 serial
I nterface
Indicator lights
DATA
Interface
U ser interface
RS485 serial
I nterface

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 8 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
FA
FA
FA
FA 20
20
20
20 3
3
3
3 CDMA
CDMA
CDMA
CDMA LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal
CDMA2000 1xRTT 800MHz
800/1900MHz(optional)
450MHz(optional)
153.6Kbps <30dBm <-104
dBm
FA
FA
FA
FA 30
30
30
30 3
3
3
3 EDGE
EDGE
EDGE
EDGE LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal
GSM850/900/1800/1900MHz
GPRS/EDGE Class 12
236.8Kbps GSM850/900 :
<33dBm
GSM1800/1900
:
<30dBm
<-106
dBm
FA
FA
FA
FA 40
40
40
40 3
3
3
3 WCDMA&HSDPA&HSUPA
WCDMA&HSDPA&HSUPA
WCDMA&HSDPA&HSUPA
WCDMA&HSDPA&HSUPA LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal
UMTS/WCDMA/HSDPA/HSUPA
850/1900/2100MHz,
850/900/1900/2100MHz(optional)
GSM850/900/1800/1900MHz
GPRS/EDGE CLASS 12
HSUPA:5.76Mbps
(Upload speed)
HSDPA:7.2Mbps
(Download speed)
UMTS:384 Kbps (DL/UL)
<24dBm <-109
dBm
FA
FA
FA
FA 50
50
50
50 3
3
3
3 TD-SCDM
TD-SCDM
TD-SCDM
TD-SCDM LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal
TD-SCDMA/HSDPA/HSUPA
1880-1920/2010-2025MHz
GSM850/900/1800/1900MHz
GPRS/EDGE CLASS 12
Download speed:2.8Mbps
U pload speed:2.2Mbps
<24dBm <-108
dBm
FA
FA
FA
FA 60
60
60
60 3
3
3
3 CDMA2000
CDMA2000
CDMA2000
CDMA2000 1X
1X
1X
1X EVDO
EVDO
EVDO
EVDO LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal
CDMA2000 1X EVDO Rev
A
800MHz,800/1900MHz(optional)
450MHz (optional)
CDMA2000 1X RTT, IS-95 A/B
Download speed:3.1Mbps
U pload speed:1.8Mbps
<23dBm <-104
dBm
Hardware
Hardware
Hardware
Hardware System
System
System
System
Item
Item
Item
Item Content
Content
Content
Content
CPU Industrial 16/32 bits CPU
FLASH 1 MB(Extendable)
SRAM 512K B(Extendable)
Interface
Interface
Interface
Interface Type
Type
Type
Type
Item
Item
Item
Item Content
Content
Content
Content
Serial 1 RS232 port and 1 RS485(orRS422) port, 15KV ESD protection
Data bits: 5, 6 ,7, 8
Stop bits: 1, 1.5, 2
Parity: none, even, odd, space, mark

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 9 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
Baud rate : 110 ~ 230400 bps
Indicator "Power", "A CT " , "Online"
Antenna Standard SMA female interface, 50 ohm , lighting protection(optional)
SIM/UIM Standard 3V/1.8V user card interface , 15KV ESD protection
Power Standard 3-PIN power jack , reverse-voltage and overvoltage protection
Power
Power
Power
Power Input
Input
Input
Input
Item
Item
Item
Item Content
Content
Content
Content
Standard Power DC 12V/0.5A
Power Range DC 5 ~ 35V
Consumption <25 0mA (12V)
Physical
Physical
Physical
Physical Characteristics
Characteristics
Characteristics
Characteristics
Item
Item
Item
Item Content
Content
Content
Content
Housing Iron, providing IP30 protection
Dimensions 9 1 x 58.5 x2 2 mm
Weight 205g
Environmental
Environmental
Environmental
Environmental Limits
Limits
Limits
Limits
Item
Item
Item
Item Content
Content
Content
Content
Operati ng
T
emperature
-25~+ 65 º C (-13 ~+ 149 ℉ )
Extended
Operati ng
T
emperature
- 30 ~+ 75 º C (-22 ~+ 167 ℉ )
Storage
T
emperature
-40~+85 º C (-40 ~+ 185 ℉ )
Operati ng
Humidity
95% ( Non-condensing)

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 10 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
C
C
C
C hapter
hapter
hapter
hapter 2
2
2
2 Installation
Installation
Installation
Installation Introduction
Introduction
Introduction
Introduction
2.1
2.1
2.1
2.1 General
General
General
General
The LED Intelligent Terminal must be installed correctly to make it work properly.
Warning: Forbid to install the LED Intelligent Terminal when powered!
2.2
2.2
2.2
2.2 Encasement
Encasement
Encasement
Encasement List
List
List
List
Name Quantity Remark
LED Intelligent Terminal
host
1
Antenna 1
Power adapter 1
RS232 data cable 1 optional
RS485 data cable 1 optional
M anual CD 1
Certification card 1
Maintenance card 1
2.3
2.3
2.3
2.3 Installation
Installation
Installation
Installation and
and
and
and Cable
Cable
Cable
Cable Connection
Connection
Connection
Connection
Dimension
Dimension
Dimension
Dimension :
:
:
: (unit:
(unit:
(unit:
(unit: mm)
mm)
mm)
mm)

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 11 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
58.5
35
28
28
22
8
25
Ф3
Ф5
4
Installation
Installation
Installation
Installation of
of
of
of SIM/UIM
SIM/UIM
SIM/UIM
SIM/UIM card:
card:
card:
card:
Firstly power off the LED Intelligent Terminal, and press the out button of the SIM/UIM card
outlet with a needle object. Then the SIM/UIM card sheath will flick out at once. Put SIM/UIM
card into the card sheath (Pay attention to put the side which has metal point outside), and insert
card sheath back to the SIM/UIM card outlet.
Warning:
Warning:
Warning:
Warning: Forbid to install SIM/UIM card when powered!
Installation
Installation
Installation
Installation of
of
of
of antenna:
antenna:
antenna:
antenna:
Screw the SMA male pin of the antenna to the female SMA outlet of the LED Intelligent
Terminal tightly. Warning: The antenna must be screwed tightly, or the signal quality of antenna
will be influenced!
Installation
Installation
Installation
Installation of
of
of
of cable:
cable:
cable:
cable:
Insert DB9F end of the RS232/RS485 data cable into the DB9M interface of LED Intelligent
Terminal, and connect the other end with user
’
s device.
The signal connection of the RS232 data cable is as follows:
DB9F
DB9F
RS232 data cable
1
RXD 2
TXD 3
4
GND 5
6
7
8
9
1
2 RXD
3 TXD
4
5GND
6
7
8
9

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 12 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
The signal connection of the RS485 data cable is as follows:
2.4
2.4
2.4
2.4 Power
Power
Power
Power
The power range of the LED Intelligent Terminal is DC 5 ~35V
Warning: When we use other power, we should make sure that the power can supply power
above 4W.
We
recommend user to use the standard DC 12V/ 0 .5A power adaptor.
2.5
2.5
2.5
2.5 Indicator
Indicator
Indicator
Indicator Lights
Lights
Lights
Lights Introduction
Introduction
Introduction
Introduction
The LED Intelligent Terminal provides three indicator lights: “ Power ” , “ ACT ” , “ Online ” .
Indicator
Light
State Introduction
Power ON LED Intelligent Terminal is powered on
OFF LED Intelligent Terminal is powered off
ACT BLINK Data is communicating
OFF No data
Online ON LED Intelligent Terminal has logged on network
OFF LED Intelligent Terminal hasn ’ t logged on
network
DB9F
RS485 data cable
1
2
3
4
5
A
6
7
8
B 9
A
(RED)
B (BLACK)

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 13 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
Chapter
Chapter
Chapter
Chapter 3
3
3
3 Configuration
Configuration
Configuration
Configuration
3.
3.
3.
3. 1
1
1
1 Configuration
Configuration
Configuration
Configuration Connection
Connection
Connection
Connection
Before configuration, it ’ s necessary to connect the LED Intelligent Terminal with the
configure PC by the shipped RS232 or RS232-485 conversion cable as following.
3.
3.
3.
3. 2
2
2
2 Configuration
Configuration
Configuration
Configuration I
I
I
I ntroduction
ntroduction
ntroduction
ntroduction
There are two ways to configure the LED Intelligent Terminal:
Configuration software tool: All the settings are configured through the shipped software tool.
It
’
s necessary to have one PC to run this tool.
Extended
AT
command: All the settings are configured through
AT
command, so any device
with serial port can configure it. Before configuration with extended
AT
command, you should
make LED Intelligent Terminal enter configure state. The steps how to make LED Intelligent
Terminal enter configure state, please refer to appendix.
The following describes how to configure LED Intelligent Terminal with the configure software
tool. At the same time, it gives out the corresponding
AT
command of each configuration item.

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 14 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
3.3
3.3
3.3
3.3 Run
Run
Run
Run the
the
the
the configure
configure
configure
configure Tool:
Tool:
Tool:
Tool: IP
IP
IP
IP Modem
Modem
Modem
Modem Configure.exe
Configure.exe
Configure.exe
Configure.exe
The “ Serial Parameters ” column shows the current serial port settings.
To
configure LED
Intelligent Terminal, please choose the correct serial port which connects to LED Intelligent
Terminal, and the baudrate is 115200 with no parity, then open the serial port. I f the button text is
“ Close ” , it shows the serial port now has been opened. If the text is “ Open ” , you should open the
port first. W hen the port opened, the “ Output Info ” column will display
“ Port(COM1) Has Opened ,Please Re-Power the LED Intelligent Terminal,
Waiting LED Intelligent Terminal Enter Configure State... ”
3.4
3.4
3.4
3.4 Re-power
Re-power
Re-power
Re-power LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal
After Re-power LED Intelligent Terminal, The configure tool will make it enter configure state.

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 15 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
At the same time, the software will load current settings from LED Intelligent Terminal and
displays on the right configure columns. It ’ s now ready to configure.
3.5
3.5
3.5
3.5 Configuration
Configuration
Configuration
Configuration
3.5.1
3.5.1
3.5.1
3.5.1 Data
Data
Data
Data Service
Service
Service
Service Center
Center
Center
Center Settings
Settings
Settings
Settings
Settings on this page are the parameters related to Data Service Center(DSC).
◆Data Center Number
LED Intelligent Terminal support two Data Service Center methods to transmit data.
Main and Backup: LED Intelligent Terminal always tries to connect with the Main DSC. If fails
to connect with Main DSC, it will connect with Backup DSC at once
Note :If no Backup DSC exists, please configure the Backup DSC same as Main DSC.
Multi Data Service Center: LED Intelligent Terminal can connect with at most five DSC at the
same time. A ll the multi DSC can receive the same application data .
If the Data Center Number is 1, LED Intelligent Terminal work in Main and Backup DSC
method.
When “ Data Center Number ” is greater than 1, LED Intelligent Terminal works in Multi Data
Service Center method
AT
command:
AT+SVRCNT= x
x: Data Service Center number
Note: every
AT
command is terminated with a enter character.
◆Main Center Addr+Port:
IP Address and Port of the Main DSC, It ’ s better to set the port greater than 1024.
AT
command of the Main DSC IP address or domain name:

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 16 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
AT+IPAD=xxx
xxx: The IP address or domain name.
AT
command of the Main DSC port:
AT+PORT=xxx
xxx: The port value
◆Backup Center Addr+Port:
IP address and port of the Backup DSC
AT
command of the Backup DSC IP address or domain
AT+IPSEC=xxx
xxx: The IP address or domain name
AT
command of the Backup DSC port
AT+PTSEC=xxx
xxx: The port value
◆Multi DSC Configuration
When “ Data Center Number ” is greater than 1, this setting is valid. F or example ,setting the
“ Data Center Number ” as 3, Main Center, 2nd Center, 3rd Center work as these three DSC
AT
Command of the 2~5 DSC
IP
address or domain name
AT+IPADn=xxx
n is 1~4 correspond to center 2~5
xxx: The IP address or domain name
AT
Command of the 2~5 DSC port
AT+PORTn=xxx
n is 1~4 correspond to port of center 2~5
xxx: The port value
Example:
Set IP address of center 3 as 166.111.8.238, and port 5001, the
AT
command is as following:

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 17 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
AT+IPAD2=166.111.8.238
AT+PORT2=5001
◆Main and Backup Center DNS Server
W hen the DSC Internet access uses domain name, It ’ s necessary to set DNS server resolving the
DSC domain name. When the Data Center Number is 1, Main and Backup Center DNS Server is
used to resolve the Main center and Backup center correspondingly .
AT
command of Main Center DNS server:
AT+DNSSVR= aaa.bbb.ccc.ddd
aaa.bbb.ccc.ddd: The DNS server
IP
address(must be IP address ).
AT
command of Backup Center DNS server:
AT+DNSSV2= aaa.bbb.ccc.ddd
aaa.bbb.ccc.ddd: the DNS server
IP
address
◆Center 2~5 DNS Server
When the LED Intelligent Terminal work in Multi Data Service Center method and the centers
use domain name, 2~5 DNS server is used to resolve center 2~5 correspondingly.
AT
command of 2~5 DNS Server
AT+DNSSVRn= aaa.bbb.ccc.ddd
n is 1~4 correspond to center 2~5 DNS server.
aaa.bbb.ccc.ddd is the DNS server IP address
3.5.2
3.5.2
3.5.2
3.5.2 LED
LED
LED
LED Intelligent
Intelligent
Intelligent
Intelligent Terminal
Terminal
Terminal
Terminal Settings
Settings
Settings
Settings

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 18 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
◆LED Intelligent Terminal WorkMode
According to different application requirements, there are several protocol workmode to choose.
PROT :Heartbeat packet with TCP protocol, Data transmission with TCP protocol, heartbeat
packet and application data transmission are in the same TCP connection.
TRNS :LED Intelligent Terminal work as a common GPRS MODEM, It can be used in SMS,
CSD, dial-up applications.
TTRN :Heartbeat packet with UDP protocol, Data transmission with TCP protocol
TLNT :LED Intelligent Terminal work as a telnet client
LON G : Heartbeat packet with UDP protocol, Data transmission with TCP protocol, It can transmit
at most 8192 bytes data one time through extra application protocol.
LNGT :Heartbeat with TCP protocol, Data transmission with TCP protocol, It can transmit at most
8192 bytes data one time through extra application protocol.
TUD P : Heartbeat with UDP protocol, Data transmission with UDP protocol, Heartbeat packet and
application data are in the same UDP connection.
TCST :User can set custom register and heartbeat string, Data transmission with TCP protocol.
AT
command:
AT+MODE=xxxx
xxxx: one of the above workmode
◆Trigger Type
Normally, LED Intelligent Terminal always keeps online and always be ready for data
transmission. B ut in some circumstances, it ’ s important to reduce wireless data flow.
To
realize
this function, the software can makes LED Intelligent Terminal into sleep state in idle time. W hen
there is application data to transmit, LED Intelligent Terminal can be triggered online ready for
data transmission. There are total five methods to make LED Intelligent Terminal online:
AUTO: LED Intelligent Terminal always keeps online
SMSD: send a special short message to make LED Intelligent Terminal online
CTRL: make LED Intelligent Terminal online through a phone call to LED Intelligent Terminal
DATA:
send special serial data to make LED Intelligent Terminal online
MIXD: the combination of SMSD, CTRL,
DATA.
LED Intelligent Terminal will be online when

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 19 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
meet one of these three trigger methods.
AT
Command:
AT+ACTI=xxxx
xxxx: one of the above trigger methods
◆Debug Level
Debug information is used to debug software when there is software problem.
0 --- no debug information output
1 --- simple prompt information output
2 --- detail debug information output
AT
Command:
AT+DEBUG=x
x : the debug level value
Note: Only there is some problem to the LED Intelligent Terminal, It
’
s necessary to set this
value as 2, In normal applications, this value should set to 0 or 1, the default value is 1.
◆Databit, Parity, Stopbit
8N1 --- 8 Databit, No parity, 1 Stopbit
8E1 --- 8 Databit, Even parity, 1 Stopbit
8O1 --- 8 Databit, Odd parity, 1 Stopbit
AT
Command:
AT+SERMODE =xxx
xxx: one of the above serial mode
◆Communication Baudrate

User Manual
Xiamen
Xiamen
Xiamen
Xiamen Four-Faith
Four-Faith
Four-Faith
Four-Faith Communication
Communication
Communication
Communication Technology
Technology
Technology
Technology Co.,Ltd.
Co.,Ltd.
Co.,Ltd.
Co.,Ltd. Page 20 of 30
Add
:J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http ://www.f ourfaith .com Tel :+86 592-6300326 6300325 6300324 Fax :+86 592-5912735
110 --- 110 bps
300 --- 300 bps
600 --- 600 bps
1200 --- 1200 bps
2400 --- 2400 bps
4800 --- 4800 bps
9600 --- 9600 bps
14400 --- 14400 bps
19200 --- 19200 bps
38400 --- 38400 bps
56000 --- 56000 bps
57600 --- 57600 bps
115200 --- 115200 bps
AT
Command:
AT+IPR=xxx
xxx : one of the above baudrate
◆Auto Back
To
Main Server
0 --- No
1 ---Yes
This item is only valid when you set “ Data Center Number ” as 1. In this mode, LED Intelligent
Terminal will switch to backup center when main center have problems. If this item is set to 1 ,
LED Intelligent Terminal will check whether the main center work fine timely. W hen it detects the
main server work fine, it will return back to the main server at once.
AT
Command:
AT+RETMAIN=x
x : 0 or 1
◆Device ID
The identity number of LED Intelligent Terminal, the value should be 8 bytes hex-decimal
This manual suits for next models
8
Table of contents
Other Four-Faith Touch Terminal manuals
Popular Touch Terminal manuals by other brands

Ampac
Ampac LoopSense EN54 Installation, commissioning & operation

Panasonic
Panasonic HM 700 Series instruction manual

Hughes
Hughes 9202 user guide

UTStarcom
UTStarcom NetSprite1023 user guide

Mitsubishi Electric
Mitsubishi Electric GT14 user manual

Money Controls
Money Controls Ardac IBA5 Specification and Adjustment Manual