Fracarro MOD-WL04 User manual

INTERFACCIA FILO-RADIO
UNIVERSAL WIRELESS EXPANSION
EXPANSION SANS-FIL UNIVERSELLE
MOD-WL04
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
ISTRUZIONI PER L’USO
OPERATING INSTRUCTIONS
INSTRUCTIONS D’EMPLOI

2
ITALIANO
CARATTERISTICHE TECNICHE
Alimentazione 9 ÷ 15 Vdc
Assorbimento massimo 60 mA
Frequenza Radio (multicanale) 868,6 MHz
Distanza radio (all’aperto) max 300 m
Uscite connessione in centrale 4
Uscite segnalazioni guasti e Tamper 2
Ingressi a relé per comando sirena, reset rivelatori tecnologici e stato della centrale
3
Temperatura di lavoro -10 ÷ +50 °C
Dimensioni (lxpxh) 90x72x29 mm
FUNZIONI
Indicazione dei LED:
N° Nome Funzione
1 LED Acceso - Alimentazione presente;
Spento - Alimentazione assente;
2 Z1÷Z4
Led indicatore di stato della zona 1÷4;
Verde – Zona chiusa
Rosso – Zona aperta
Spento – Zona senza dispositivi acquisiti
3 Snd
Indicatore di stato delle sirene
Verde - Zona con sirena o combinatore acquisito
Spento – Zona senza dispositivi acquisiti
Fig.1
Indicazione ingressi e uscite:
N° Nome Funzione
4 AC/DC Alimentazione 9÷15Vdc;
4 Out1 Uscita a relé (normalmente aperto) indicante le informazioni di “Batteria bassa” ;
4 Out2 Uscita a relé (normalmente chiuso) indicante le informazioni di TAMPER e “Perdita dispositivo”;
4 In1 Ingresso per il reset dei dispositivi wireless antincendio (dare un riferimento a Negativo per almeno
2 secondi);
4 In2 Ingresso per il controllo delle sirene e combinatori wireless;
4 In3 Ingresso stato centrale. Da collegare solo in caso di utilizzo del telecomando WL04TC per l’inseri-
mento e il disinserimento di una centrale filare Defender 64;
4 Z1÷Z4 Uscite per la connessione diretta delle zone alla centrale;
5 TMPR Terminale per la connessione del TAMPER supplementare (es. Tamper della scatola di derivazione);
6 MODE
Impostazione della modalità di connessione delle zone:
a)
Jumper Inserito – le uscite Z1
÷Z4 hanno una terminazione di linea con
doppio bilanciamento (valido
solo per le centrali Fracarro): in questa modalità vengono rilevati gli allarmi TAMPER dei dispositivi indi-
candoli nella zona corrispondente.
b) Jumper Disinserito –
le uscite Z1
÷Z4 hanno una terminazione di linea con modalità NC (modalità
interfaccia universale).
DESCRIZIONE
L’interfaccia filo-radio MOD-WL04 è un dispositivo universale per l’espansione, con dispositivi del sistema wireless DEFEN-
DER WL, di sistemi di sicurezza filari esistenti. L’interfaccia comunica a mezzo di un collegamento radio bidirezionale con un
massimo di 32 dispositivi tra cui: WL04GSM (combinatore telefonico), WL04BL 100EX, WL04BL 200EX (barriere infrarosso),
WL04IR (rilevatore infrarosso), WL04IR EX (rilevatore infrarosso esterno), WL04MM, WL04MB, WL04MM2, WL04MB2 (con-
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
1
4
6
2
3
5

3
ITALIANO
tatti magnetici), WL04SEL (sirena), WL04RF (rivelatore di fumo) e WL04TC (telecomando). Tutti i dispositivi possono essere
raggruppati in base alla funzionalità, collocazione oppure una combinazione di entrambi in un massimo di 4 zone. Ogni zona
dispone di una propria uscita configurabile come normalmente chiusa o a doppio bilanciamento (per centrali Fracarro). Nel
primo caso verrà comunicata solo l’informazione di allarme mentre, nel secondo caso, si avranno tutte le informazioni di
allarme e apertura contatto tamper dei dispositivi associati a tale zona. L’interfaccia dispone di due uscite supplementari
atte alla segnalazione degli eventi di “batteria bassa”, “perdita dispositivo” e “tamper” e di tre ingressi dedicati ai segnali di
reset dei rivelatori di fumo, attivazione della sirena esterna wireless e ingresso di stato della centrale per la visualizzazione
dell’inserimento sul telecomando WL04TC. In questo modo la centrale filare potrà gestire completamente tutti i nuovi di-
spositivi wireless.
NOTA: É possibile collegare fino a 2 sirene WL04SEL o una sirena e un combinatore telefonico WL04GSM.
COLLEGAMENTI
L’interfaccia filo radio MOD-WL04 può essere utilizzata per aggiungere dei dispositivi wireless della serie DEFENDER WL a
una centrale filare anche preesistente.
Collegamento a una centrale filare:
Lo stesso tipo di collegamento può essere utilizzato sia con centrali che dispongono di ingressi configurabili come normal-
mente chiusi che a doppio bilanciamento.
WL04IR
WL04SEL
WL04TC
WL04RF
WL04MM
WL04MB
WL04MM2
WL04MB2
WL04BL100 EX
WL04BL200 EX
WL04IR EX
WL04GSM
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
Collegamento a una centrale con ingressi normalmente chiusi:
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
Jumper
JP
OUT2
MOD-WL04CENTRALE
GND
+B
L4
L3
GND
L2
L1
Nel caso si stia collegando il modulo MOD-WL04 ad una centrale d’allarme filare che gestisca solamente ingressi normalmente
chiusi rimuovere il jumper MODE del modulo. Utilizzando questo tipo di connessione, nei morsetti relativi alle 4 zone disponibili,
saranno presenti le informazioni di allarme dei rivelatori mentre, nell’uscita Out2 tutte le informazioni di perdita modulo e di tamper
dei dispositivi e del contenitore.

4
ITALIANO
Collegamento a una centrale con ingressi a doppio bilanciamento (solo su centrali Fracarro):
Nel caso si stia collegando il modulo MOD-WL04 ad una centrale d’allarme filare che gestisca anche ingressi a doppio
bilanciamento inserire il jumper MODE del modulo. Utilizzando questo tipo di connessione, nei morsetti relativi alle 4 zone
disponibili saranno presenti, oltre alle informazioni di allarme, anche le informazioni di tamper dispositivi.
Nel caso di installazione di una sirena o di un combinatore wireless è necessario comunque collegare l’uscita OUT2 alla
centrale per fornire le informazioni di Tamper di questi dispositivi.
ATTENZIONE: Nel caso si debba installare il dispositivo MOD-WL04 all’interno di una centrale d’allarme, chiudere il
connettore TMPR (Fig.1:5) con un jumper.
INSTALLAZIONE
Il MOD-WL04 può essere installato all’interno di una centrale (per esempio le nuove
centrali filari DEFENDER) oppure separatamente, nel MOD-BOX. Procedere con l’in-
stallazione nel primo caso solamente se la centrale ne consente l’alloggiamento in
termini di spazio interno ed è sprovvista di coperchio in metallo, in tutti gli altri casi
procedere all’installazione nel MOD-BOX. In quest’ultimo caso è necessario colle-
gare il pulsante tamper antistrappo (KIT-TAMPER opzionale) nell’apposito connettore
TMPR (Fig.1 punto 5).
Installazione nelle centrali filari DEFENDER:
Per inserire la scheda MOD-WL04, bisogna svitare le due viti posizionate nella parte
superiore della scheda della centrale e basculare la scheda verso il basso. Poi fissare
la scheda MOD-WL04 nella parte inferiore con due viti fornite in dotazione.
Installazione nel MOD-BOX:
Inserire la scheda MOD-WL04 all’interno del contenitore nella posizione in-
dicata in figura. Fissare la scheda con le 4 viti fornite in dotazione e collegare
il pulsante tamper antistrappo (KIT-TAMPER) nell’apposito connettore TMPR
(Fig.1 punto 5).
Installazione:
Per una corretta installazione dell’interfaccia seguire tutti i passi riportati di
seguito:
1. Collegare l’interfaccia alla centrale come mostrato nel paragrafo “Col-
legamenti” avendo cura di chiudere o rimuovere il jumper MODE a se-
conda che vengano o meno utilizzate le uscite normalmente chiuse o a
doppio bilanciamento;
2. Connettere l’interruttore di tamper per la protezione antistrappo dell’in-
terfaccia (acquistato come KIT opzionale);
3. Alimentare l’interfaccia;
4. Tutti i led si accendono di arancione per qualche secondo;
5. Trascorso questo tempo rimane acceso solo il led verde ad indicare l’inizio della modalità di funzionamento NORMALE;
6. Iniziare la procedura di acquisizione dei dispositivi.
ACQUISIZIONE DISPOSITIVI
Prima di iniziare la procedura si consiglia di dividere tutti i dispositivi che si intendono acquisire in gruppi a seconda della
disposizione fisica o della tipologia degli stessi, al fine di aumentare l’efficienza del sistema.
Le zone Z1, Z2, Z3 e Z4 sono configurate per fare acquisire tutti i rivelatori infrarossi (es. WL04IR, WL04IR EX, WL04BIR100
EX,..), i rivelatori magnetici (WL04MB e WL04MM), i rivelatori di fumo WL04RF e i telecomandi WL04TC.
Per i rivelatori magnetici WL04MM e WL04MB il comportamento dell’ingresso per i dispositivi esterni ca-
blati cambia a seconda della zona su cui i dispositivi wireless sono acquisiti.
Se i contatti magnetici vengono acquisiti sulle zone Z1, Z2 e Z3 è possibile collegare all’ingresso supple-
mentare (fig. A morsetto 1) dei rivelatori a filo RF45 per la protezione delle tapparelle (configurazione fissa:
4 impulsi entro 10 secondi)
Se i contatti magnetici invece vengono acquisiti sulla zona Z4 è possibile collegare all’ingresso supple-
mentare (fig. A punto 1) dei dispositivi con contatto NC (es. contatto magnetico filare).
MOD-WL04
MOD-WL04
A

5
ITALIANO
ATTENZIONE: Nel caso si volesse utilizzare
il rilevatore magnetico solo con il magnete
interno, su zona Z4 si DEVE ponticellare il
morsetto n°1.
Esempio di acquisizione:
Z1: Rivelatori infrarosso WL04IR
Z2: Telecomando WL04TC
Z3: Rivelatori magnetici WL04MB + RF45
Z4: Rivelatori magnetici WL04MB + Contatto magnetico
filare
Per i rivelatori WL04MM2 e WL04MB2 si può eseguire una acquisizione analoga. Il canale relativo al contatto magnetico può
essere acquisito su qualsiasi zona. Il canale relativo al rivelatore esterno RF45 può essere acquisito solo sulle zone Z1, Z2 e Z3.
ATTENZIONE: Nel caso si stiano acquisendo sensori di diverse tipologie in una stessa zona, l’allarme incendio generato dal
sensore WL04RF sarà visto in centrale come un allarme generale. Pertanto si consiglia di acquisire i sensori di fumo WL04RF
in una unica zona.
Procedura di acquisizione:
1. L’interfaccia si trova nella modalità di funzionamento NORMALE con il led verde (Fig.1 punto 1) acceso;
2. Accedere alla modalità acquisizione premendo per 3 secondi il tasto LEARN (Fig.1 punto 7), il led (Fig.1 punto 1) si ac-
cenderà di rosso mentre il led Z1 (Fig.1 punto 2) di arancione;
3. Premendo il tasto LEARN spostarsi nella zona (Z1, Z2, Z3, Z4, Snd) in cui si si vuol far riconoscere il dispositivo. L’indi-
catore della zona corrispondente si accenderà in arancione; (ATTENZIONE: Le sirene wireless e i combinatori telefonici
devono essere acquisiti nella zona denominata “Snd”)
4. Seguire la procedura di acquisizione dei vari tipi di dispositivi wireless;
5. L’interfaccia conferma l’avvenuta acquisizione con una serie di 5 BEEP;
6. Premere il tasto RESET una volta per abilitare o disabilitare l’evento tamper della zona selezionata:
Colore led zona Z.. Funzione
Verde Protezione tamper disabilitata
Arancione Protezione tamper abilitata
7.
Continuare con la registrazione dei dispositivi nella stessa zona oppure spostarsi nella successiva premendo il pulsante LEARN;
8. Per uscire dalla modalità di acquisizione premere il pulsante LEARN fino a entrare nella modalità NORMALE (tutti i led
sono accesi verdi).
Modalità di funzionamento:
attraverso il tasto LEARN si può accedere a 3 diverse modalità di funzionamento.
Modalità Funzione
NORMALE I led indicano lo stato delle zone;
TROUBLE I led indicano possibili problematiche nel sistema (divise per zone);
LEARN
Acquisizione dei dispositivi nel sistema e abilitazione/disabilitazione del segnale TAMPER dei dispositivi.
Funzionalità dei tasti di programmazione:
I tasti LEARN e RESET vengono utilizzati in fase di programmazione dell’interfaccia MOD-WL04 e hanno diverse funzionalità
a seconda della modalità di utilizzo:
Tasto Modalità Operazioni Funzione
LEARN
NORMALE Premuto una volta Passa in modalità
TROUBLE per mostrare i problemi del sistema;
Premuto per 3 secondi Passa in modalità LEARN per l’acquisizione dei dispositivi;
TROUBLE Premuto una volta Passa in modalità NORMALE;
LEARN Premuto una volta
Passa alla zona successiva Z1, Z2, Z3, Z4, Snd attivando un
BEEP. Terminate le zone, un ulteriore pressione riporta il siste-
ma in modalità normale;
Connect the cables
by a Normally Closed
connection
Connecter les câbles
par une connexion
Normalement Fermée
Collegare i cavi
in un contatto
NC

6
ITALIANO
RESET
LEARN
Premuto una volta Abilita/Disabilita il segnale di TAMPER della zona selezionata;
Premuto per 3 secondi Reset della zona selezionata
FUNZIONAMENTO NORMALE
Durante il normale funzionamento i led dell’interfaccia continuano a segnalare lo stato del sistema in accordo con la seguen-
te tabella:
Led Z1 ÷ Z4 Descrizione
Rosso Almeno uno dei dispositivi sta generando un allarme
Arancione Almeno uno dei dispositivi ha dei problemi di batteria bassa o tamper aperto
Verde Normale stato dei dispositivi
Spento Nessun dispositivo acquisito
FUNZIONAMENTO DEL TELECOMANDO WL04TC
Di default i vari tasti del telecomando sono programmati per eseguire le seguenti funzioni:
Tasto Funzione
Indicazione dello stato della zona:
Sistema inserito 2 suoni corti e 1 lampeggio rosso del led; Sistema disinserito 3 suoni corti e 1
lampeggio verde del led;
Disattiva il sistema: si attiva per 2 secondi l’uscita associata per disinserire il sistema. Tasto vin-
colato dallo stato di IN3;
Attiva il sistema: si attiva per 2 secondi l’uscita associata per inserire il sistema. Tasto vincolato
dallo stato di IN3;
Attiva o disattiva il sistema: si attiva per 2 secondi l’uscita associata per inserire o disinserire il
sistema. Questa funzione si attiva indifferentemente dallo stato in cui si trova l’ingresso In3.
Sulla zona dove sono acquisiti i telecomandi non si devono acquisire dispositivi di tipo diverso.
Collegamento a una centrale Defender64:
Per effettuare il collegamento tra una centrale filare e l’interfaccia MOD-WL04 bisogna collegare un cavo tra l’uscita della
zona dove è stato acquisito il telecomando (nel nostro esempio Z4) e una linea della centrale filare dove verrà programmata
come linea “Chiave” di tipo “Impulsivo”.
Inoltre si effettuerà un collegamento tra l’uscita “P_ON” della centrale e l’ingresso “In3” per indicare lo stato della centrale
(se è Inserita o Disinserita) che poi verrà visualizzato sul telecomando WL04TC.
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
Jumper
JP
OUT2
MOD-WL04CENTRALE
GND
+B
ESC
P_ON
TECN
L2
L1
L’uscita “P_ON” deve essere programmata come Stabile – Normalmente Inattiva – Eventi centrale: Centrale Inserita
Il Jumper JP deve essere Disinserito
L’uscita “P_ON” è impostata di default come normalmente inattiva. Per accedere a questo parametro è necessario attivare
il menu avanzato di Defender 64.
Il Jumper JP permette la scelta del riconoscimento del livello logico della centrale filare
Jumper JP Inserito Quando con centrale Disinserita si ha un livello logico +12V sull’ingresso In3
Jumper JP Disinserito
Quando con centrale Inserita si ha un livello logico a 0 V sull’ingresso In3 (da una uscita
Open-Colletor)

7
ITALIANO
IMPORTANTE: Quando si va a premere un comando di attivazione sul telecomando WL04TC, la prima visualizzazione del
LED indica lo stato attuale del sistema e non quello che si è appena richiesto.
Premendo il pulsante si richiede lo stato dell’impianto.
Gestione sirene e combinatori wireless
Nel caso in cui si debba configurare una sirena o un combinatore wireless è ne-
cessario collegare l’ingresso IN2 alla centrale. Se la centrale fornisce un segnale
di riferimento +12V a mancare, si consiglia l’installazione di una resistenza da 820
Ωtra IN2 e GND. Se si esegue questo collegamento non è possibile collegare sul
morsetto di riferimento allarme della centrale altri dispositivi. Per eventuali sirene o
combinatori filari è necessario utilizzare un’altra uscita (es. relé di allarme).
MODALITÀ TROUBLE
Nella modalità di funzionamento TROUBLE è possibile controllare lo stato delle 4 zone dell’interfaccia. Per accedere a tale
modalità seguire la procedura:
1. Dalla modalità di funzionamento normale premere il tasto LEARN;
2. Consultare la seguente tabella per verificare il tipo di problema rilevato nel sistema:
Led Z1 ÷ Z4 Descrizione
Rosso Almeno uno dei dispositivi acquisito nella zona non risponde
Arancione Batteria bassa in almeno uno dei dispositivi acquisiti nella zona
Verde Almeno uno dei dispositivi acquisiti nella zona sta generando un allarme tamper
Spento Nessun problema riscontrato
3. Premere il pulsante LEARN per tornare alla modalità di funzionamento NORMALE.
RESET
L’interfaccia filo radio consente di effettuare due diverse tipologie di reset, per singola zona oppure totale.
Reset parziale:
Questa procedura permette di cancellare tutti i dispositivi acquisiti in una specifica zona:
1. Accedere alla modalità di funzionamento LEARN premendo per 3 secondi il tasto LEARN;
2. Premendo il tasto LEARN muoversi sulla zona che si intende resettare, il rispettivo led si accenderà di arancione;
3. Premere e mantenere premuto il tasto RESET per 3 secondi;
4. L’interfaccia restituisce dei BEEP di conferma dell’avvenuto reset;
5. Il led rispettivo alla zona resettasta si accenderà di arancione;
ATTENZIONE: Se il led rispettivo alla zona resettata è acceso di colore verde premere nuovamente il tasto RESET.
6. Per uscire dalla modalità LEARN premere il tasto LEARN finchè non rimarrà acceso il led verde (fig.1 punto 1).
Reset totale:
Questa procedura permette di riportare l’interfaccia alle impostazioni di fabbrica
1. Accedere alla modalità di funzionamento NORMALE;
2. Premere contemporaneamente i tasti LEARN e RESET per 3 secondi fino a un BEEP;
3. L’interfaccia restituisce dei BEEP di conferma dell’avvenuto reset e l’accensione di tutti i led in arancione;
4. Il sistema torna in modalità di funzionamento NORMALE con il solo led (fig.1 punto 1) acceso di colore verde.
APPLICAZIONI
Il MOD-WL04 può essere utilizzato su un gran numero di centrali filari al fine di estenderne le potenzialità. Di seguito si
riportano alcuni esempi di applicazioni pratiche del modulo:
1. Inserimento di una centrale da telecomando: funzionalità implementabile solo su centrali d’allarme che dispongono di
un ingresso configurabile come “chiave” (es. Defender 64, CE64T, Solution16, CE16T).
2. Utilizzo sensori wireless su una centrale filare evitando opere di muratura e di passaggio cavi per l’installazione di nuovi
dispositivi quali sirene, contatti magnetici, rivelatori di fumo, infrarossi, barriere e combinatori telefonici.
TABELLA DEI DISPOSITIVI
L’interfaccia filo radio consente di acquisire fino a 32 dispositivi della serie WL04 divisi per tipologia o posizione in un mas-
simo di quattro zone. Al fine di mantenere traccia di tali dispositivi è consigliabile compilare la tabella riportata nell’ultima
pagina del manuale. Di seguito si indica un esempio:
N° Dispositivo Posizione Zone
1 WL04IR Infrarosso cucina Z1
2 WL04TC Telecomando Z1
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
+ -
820 Ohm
+BAT GND +RIF
CENTRALE

8
ITALIANO
… … … …
32 WL04MB Magnetico finestra bagno Z4
In questo caso, nel campo “Dispositivo” sono stati elencati tutti i dispositivi acquisiti, in “Posizione” la posizione di installa-
zione e in “Zone” il numero della zona in cui si trovano.
TABELLA DISPOSITIVI
N° Dispositivo Posizione Zone
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
AVVERTENZE PER LA SICUREZZA
L’installazione del prodotto deve essere eseguita da personale qualificato in conformità alle leggi e normative locali sulla sicurezza,
e nel rispetto della Legge 46/90 (Legge 5 Marzo 1990, n° 46) e del D.M.37/08 (Decreto ministeriale 22 gennaio 2008 n°37).
Avvertenze per l’installazione: In accordo con la direttiva europea 2004/108/EC (EMC), il prodotto deve essere installato
utilizzando dispositivi, cavi ed accessori che consentano di rispettare i requisiti imposti da tale direttiva per le installazioni
fisse. Il prodotto non deve essere esposto a gocciolamento o a spruzzi d’acqua e va pertanto installato in un ambiente
asciutto, all’interno di edifici.
IMPORTANTE: Solo personale addestrato e autorizzato può aprire il prodotto, con lo scopo di effettuare le connessioni de-
scritte nelle istruzioni d’uso. In caso di guasto non tentate di riparare il prodotto altrimenti la garanzia non sarà più valida. Si rac-
comanda di verificare periodicamente il corretto funzionamento del sistema d’allarme, tuttavia un sistema di allarme elettronico
affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situazioni si verifichino.
CONFORMITÀ ALLE DIRETTIVE EUROPEE - Con la presente Fracarro Radioindustrie SpA dichiara che il prodotto è
conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/EC (RTTE - Apparati radio
e terminali di telecomunicazione).

9
ENGLISH
TECHNICAL FEATURES
Power supply 9 ÷ 15 Vdc
Absorption max 60 mA
Radio frequency 868,6 MHz
Radio range max 300 m
Outputs connection control panel 4
Output for tamper and faults alarm 2
Relay input for controlling sirens, reset devices and status of control panel 3
Working temperature -10 ÷ +50 °C
Dimensions (lxdxh) 90x72x29 mm
FUNCTIONS
LED indication:
N° Name Function
1 LED ON – Power ON;
OFF – Power OFF;
2 Z1÷Z4 Status indication of zone 1÷4;
3 Snd
Status indication of sirens.
Red – Siren ON
Green – Siren OFF
Fig.1
Input and output indication
N° Name Function
4 AC/DC Power supply 9÷15Vdc;
4 Out1 Relay output (normally open) for “low battery” indication;
4 Out2 Relay output (normally closed) for Tamper and Lost Device indication;
4 In1 Input for reset fire wireless devices (Negative reference for at least 2 seconds);
4 In2 Input for controlling wireless sirens and diallers
4 In3 Input for control panel status. To be connected only in case of using WL04TC remote con-
trol for activation/deactivation of Defender 64 wired control panel
4 Z1÷Z4 Output for direct connection of the zones to the control panel
5 TMPR Terminal for connecting an additional tamper micro switch
6 MODE
Setting of zones connection mode:
a) Jumper in – output Z1-Z4 have line termination set as double balancing mode (only for
Fracarro control panels); in this mode the Tamper alarms are detected and indicated in
the corresponding zone;
b) Jumper removed – output Z1-Z4 have line termination set as Normally Closed (mode
universal interface).
DESCRIPTION
The interface MOD-WL04 is a universal device for expanding wired security systems with WL04 series wireless devic-
es. The interface communicates via a bi-directional radio signal with maximum 32 devices including: WL04GSM (dialler),
WL04BL100 EX, WL04BL200 EX (Infrared barriers), WL04IR (infrared detector), WL04IR EX (outdoor infrared detector),
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
1
4
6
2
3
5

10
ENGLISH
WL04MM, WL04MB, WL04MM2, WL04MB2 (magnetic contact), WL04SEL (siren), WL04RF (smoke detector) and WL04TC
(remote control). All the devices can be grouped up to 4 zones according to functionality, location, or a combination of both.
Each zone has its own output configurable as normally closed or double balancing (for Fracarro control panels).
In the first case only the alarm information will be communicated; in the second case, you will have all the information about
alarm and opening tamper contact of the devices associated with that zone. The interface has two additional outputs for the
signalisation of events such as “battery low”, “device lost” and “tamper”; it has also three inputs dedicated to the signal of
reset smoke detectors and activation of external siren. In this way the wired control panel will completely manage all new
wireless devices.
NOTE: it’s possible to connect up to 2 sirens WL04SEL or one siren and one telephone dialler.
CONNECTIONS
The MOD-WL04 interface can be used to add wireless devices of DEFENDER WL series to a wired control panel (even exist-
ing):
Connection to a wired control panel:
The same type of connection can be used with control panels having both normally closed inputs and double balancing.
WL04IR
WL04SEL
WL04TC
WL04RF
WL04MM
WL04MB
WL04MM2
WL04MB2
WL04BL100 EX
WL04BL200 EX
WL04IR EX
WL04GSM
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
Connection to a control panel with Normally closed inputs:
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
Jumper
JP
OUT2
MOD-WL04CONTROL PANEL
GND
+B
L4
L3
GND
L2
L1
If you are connecting MOD-WL04 to a wired control panel that operates only with normally closed inputs, jumper MODE must be
removed from the module.
Using this type of connection, on the terminals related to the 4 available zones will be communicated alarm information. The output
Out2 will communicate information about lost devices and tamper of the devices and box.

11
ENGLISH
Connection to a control panel with double balancing inputs (only Fracarro control panels):
If you are connecting MOD-WL04 to a wired control panel that operates even with double balancing inputs insert jumper
MODE of the module. Using this type of connection, on the terminals related to the 4 available zones will be communicated
both alarm and tamper devices information. In case of installation of a siren or wireless dialler, the output Out2 must be con-
nected to the control panel in order to provide the tamper information of these devices.
ATTENTION: If MOD-WL04 must be installed within a control panel close the connector TMPR (Fig. 1: 5) with a
jumper.
INSTALLING
The MOD-WL04 may be installed within a Control panel (for example within the new
Fracarro Defender wired control panels) or separately in the MOD-BOX.
In the first case proceed with the installation only if the panel has adequate interior
space to allow the housing and has no metal cover; in all other cases install the
module in the MOD-BOX. In this case it is necessary to connect the tamper button
TMPR into the connector (Fig. 1: 5).
Installing in the control panel DEFENDER:
To insert the card MOD-WL04, unscrew the two screws at the
top of the board of the Control panel and tilt the board down.
Then fix MOD-WL04 card at the bottom with two screws provided.
Installing the MOD-BOX:
Insert the card MOD-WL04 within the box in the position indicated
in the figure. Fix the card using the 4 screws provided and connect
tamper button (KIT-TAMPER) in the connector TMPR
(Fig. 1 point 5).
Installation:
For a proper installation of the interface follow the steps below:
1. 1. Connect the interface to the control panel as shown in the paragraph
“Connections”; close or remove the jumper mode, depending on whether
there are used outputs normally closed or double balancing;
2. 2. Connect the tamper switch for the protection of the interface from
removal (optional kit);
3. 3. Power up the interface;
4. 4. All the LED light up in orange for a few seconds;
5. 5. After this time only the green led is on and indicates the beginning of
the normal mode operation;
6. 6. Start the acquisition of devices.
DEVICES ACQUISITION
Before starting the procedure is recommended to divide all the devices to be acquired into groups according to the location
or type, in order to increase the efficiency of the system.
The zones Z1, Z2, Z3, Z4 are set for the acquisition of all the infrared detectors (WL04IR, WL04IR EX, WL04BIR100EX...),
magnetic detectors (WL04MB and WL04MM), smoke detectors WL04RF and remote controls WL04TC.
For magnetic detectors WL04MB and WL04MM, the behaviour of the input of wired devices changes
depending on which zone the detectors are acquired.
If the magnetic contacts are acquired on zones Z1, Z2, Z£ it’s possible to connect to the additional input
(fig.A, terminal 1) detector for shutter protection, RF45 (set configuration: 4 pulses in 10 seconds)
If the magnetic contacts are acquired on zone Z4 it’s possible to connect devices with normally closed
contact to the additional input, for example wired magnetic device. (fig. A 1)
MOD-WL04
MOD-WL04
A

12
ENGLISH
Attention: If you wish to use the magnetic
detector only with the internal magnet, on
the azone Z4 you MUST put a jumper in Ter-
minal 1.
Example of acquisition:
zone Z1 Infrared detector WL04IR
zone Z2 Remote control WL04TC
zone Z3 Magnetic Contact WL04MB + RF45
zone Z4 Magnetic Contact WL04MB + wired magnetic device
For detectors WL04MM2 and WL04MB2 you can make a similar acquisition. The channel for the magnetic contact can be
acquired in any area. The channel for the external detector RF45 can be acquired only on the zones Z1, Z2 and Z3.
ATTENTIOM: If you are acquiring different types of sensors in the same area, the fire alarm generated by WL04RF detector
will be seen as a general alarm. Therefore, it’s suggested the aquisition of smoke detectors WL04RF in one area
Procedure of acquisition:
1. The interface is in NORMAL operating mode with the green led (Fig.1: 1) on;
2. Start the acquisition mode by pressing for 3 seconds the LEARN button (Fig. 1: 7), the LED (Fig.1:1) will light red while the
LED Z1 (Fig.1: 2) will light orange;
3. Pressing the LEARN button move to the zone (Z1, Z2, Z3, Z4, Snd) in which you want to recognize the device. The zone
indicator will light orange; ATTENTION: The wireless siren and telephone dialler should be acquired in the zone “Snd”;
4.Follow the procedure of acquiring of wireless devices;
5.The interface confirms the acquisition through a series of 5 BEEP;
6.Press once the RESET button to enable or disable the tamper event of the selected zone:
Led Color zone Z Function
Green Tamper protection disabled
Orange Tamper protection enabled
7. Continue with the recording of devices in the same zone or move to the next one by pressing the LEARN button
8. To exit the acquisition, press the LEARN button to enter the NORMAL mode (all LEDs are lit green).
Functioning mode:
By LEARN button it’s possible to accede to different functioning mode:
MODE Function
NORMAL
The Leds indicate the status of the zones
TROUBLE
The Leds indicate possible problems of the system (divided in zones)
LEARN
Acquisition of the devices in the system and abilitation/ disabilitation of TAMPER signal of the devices
Function of programming buttons:
LEARN and RESET buttons are used to program MOD-WL04 and have different function, depending on the use:
Button Mode Operation Function
LEARN NORMAL Press once Pass to TROUBLE mode to show system troubles
3 seconds press Pass to LEARN mode for devices acquisition;
TROUBLE Press once Pass in NORMAL mode;
LEARN Press once
Pass to the next zone Z1, Z2, Z3, Z4, Snd activating a BEEP.
When the cycle is ended one pression restore the normal
mode of the system;
Connect the cables
by a Normally Closed
connection
Connecter les câbles
par une connexion
Normalement Fermée
Collegare i cavi
in un contatto
NC

13
ENGLISH
RESET
LEARN
Press once Enable/Disable TAMPER signal of the selected zone
3 seconds press Reset of the selected zone
NORMAL FUNCTIONING
During normal functioning the led of the interface signalize system status as shown in the table below:
Led Z1 ÷ Z4 Description
Red At least one of the devices has generated an alarm
Orange At least one of the devices has “low battery” or “Opening tamper”
Green Normal status of the devices
OFF No device acquired
FUNCTIONING OF THE REMOTE CONTROL WL04TC
By default, the remote control keys are programmed to perform the following functions:
Button Function
Zone status indication:
System activated: 2 short beeps and 1 red blink of the led
System disabled: 3 short beeps and 1 green blink of the led
System disabling: the output is activated for 2 seconds in order to disable the system. Button
linked to the status of In3
System abling: the output is activated for 2 seconds in order to able the system. Button linked to
the status of In3
System activation or disactivation: the output is activated for 2 seconds in order to activate or
disactivate the system. This function doesn’t depend on the status of input In3
On the zone where the remote controls are acquired do not acquire different types of devices.
Connecting to a control panel Defender64:
To make the connection between a wired control panel and interface MOD-WL04 it is necessary to connect a cable between
the output of zone where it has been acquired a remote control (in our example, Z4) and a line of the wired control panel
where it will be programmed as line “key” type “Impulsive.”
Moreover, it will make a connection between the output “P_ON“ of the control panel and the input ”In3“ to indicate the status
of the control panel (If it is abled or disabled) which will then be displayed on the remote control WL04TC.
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
Jumper
JP
OUT2
MOD-WL04CONTROL PANEL
GND
+B
ESC
P_ON
TECN
L2
L1
The output “P_ON“ must be programmed as Stable – Normally Inactive – Control panel Events: Control panel activated
Jumper JP must be Off
The output “P_ON“ is set by default as normally inactive.
To access this parameter is necessary to activate the Advanced menu of Defender 64.
Jumper JP allows the choice of recognizing the logic level of the wired control panel.
Jumper JP inserted when with control panel deactivated there is a logical level +12V on the input In3
Jumper JP not inserted when with control panel activated there is a logical level 0V on the input In3 (from
open-collector output)

14
ENGLISH
IMPORTANT: when pressing an activation command on the remote control WL04TC, the first visualisation of the LED indi-
cate the current status of the system and not what it has just been required.
Pressing the button the status system can be required.
Managing wireless sirens and telephone dialler
In case you should configure a siren or dialer is necessary to connect the input
IN2 to the panel. If the panel gives a signal +12 V reference fails, we recommend
the installation of a resistance of 820 Ωbetween IN2 and GND. If you run this con-
nection is not possible to connect other devices on the alarm reference terminal of
the control panel. If you have any sirens or wired diallers you need to use another
output (eg alarm relay).
TROUBLE MODE
In the TROUBLE mode you can check the status of the 4 zones of the interface. To access this mode follow the steps below:
1. From the normal operating mode press the LEARN button;
2. Check the following table to verify the type of problem detected in the system:
Led Z1 ÷ Z4 Description
Red At least one of the devices acquired in the zone doesn’t answer
Orange At least one of the devices acquired in the zone has low battery
Green At least one of the devices acquired in the zone is generating tamper alarm
OFF No trouble found
3. Press LEARN button to return to NORMAL functioning mode.
RESET
The interface allows two different types of reset, partial or total:
Partial reset:
This procedure delete all the devices acquired in a specific zone:
1. Access the LEARN mode by pressing for 3 seconds the LEARN button;
2. Pressing the LEARN button move on the zone that will be reset, its LED will light orange;
3. Keep press the RESET button for 3 seconds;
4. The interface confirm the reset through some BEEPs;
5. The Led of the reset zone will light orange;
ATTENTION: If the LED corresponding to the zone is green press again the RESET button.
6. To exit the Learn mode, press the LEARN button until only the green led is on. (Fig. 1.1)
Total reset:
This procedure allows to restore the interface to its factory settings:
1. Enter NORMAL mode;
2. Press simultaneously the LEARN and RESET buttons for 3 seconds, it will be a BEEP;
3. The interface confirm the reset through some confirmation BEEP;
4. The system returns to normal operation mode with just one led green on.
APPLICATIONS
The MOD-WL04 can be used on a large number of wired control panels in order to extend their potential. The following are
examples of practical applications of the module:
1. Activation of a control panel by remote control functionality can be implemented only if the panel has an input configured
as a “key” (eg Defender 64, CE64T, Solution16, CE16T).
2. Using wireless sensors on a control panel without masonry and cabling the installation of new devices such as sirens,
magnetic contacts, smoke detectors, infrared, barriers and telephone dialers.
TABLE OF DEVICES
The interface allows to acquire up to 32 devices of Defender WL04 series, divided by type or position in up to 4 zones; to
keep track of these devices is always advisable to fill the table in the last page of this manual. Here is an example:
N° Device Position Zone
1 WL04IR Kitchen: infrared Z1
2 WL04TC Remote control Z1
… … … …
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
+ -
820 Ohm
+BAT GND +RIF
CENTRALE

15
ENGLISH
32 WL04MB Magnetic contact bathroom Z4
In this case, in the cell “Device” are listed all the devices acquired; in “position” the position of installation and in “Zone” the
number of the zone where they are placed.
TABLE OF DEVICES
N° Device Position Zone
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
SAFETY WARNINGS
The system must be installed by qualified operators, in compliance with current national and local safety laws
.
Installation warnings
:
In compliance with European Directive 2004/108/EC (EMC), the system must be installed using de-
vices, cables and accessories that comply with the requisites established by the Directive for permanent installations.
The product must not be exposed to dripping or splashing and thus it shall be installed indoors, in a dry place.
IMPORTANT: Only trained and authorised personnel are allowed to work on the system for the connections as described in
the instruction manual.
In the case of a fault, do not attempt to repair the product as it would render the guarantee invalid.
It is advisable to periodically check that the alarm system is in perfect working order; however a reliable electronic alarm
system does not prevent intrusion, theft, fire or other events but helps to reduce the risk of them occurring.
CONFORMITY WITH EUROPEAN DIRECTIVES
- Fracarro Radioindustrie SpA declares that the product conforms to the
essential requisites and other permanent provisions established by the directive 1999/5/EC (RTTE - Radio and Telecom-
munications Terminal Equipment).

16
FRANÇAIS
CARACTÉRISTIQUES TÉCHNIQUES
Alimentation 9 ÷ 15 Vdc
Consommation max 60 mA
Fréquence radio 868,6 MHz
Portée radio (à l’exterieur) max 300 m
Nombre de connexion sortie alarme 4
Nombre de sortie alarme défaut et Tamper 2
Entrées relais pour la commande de la sirène, réinitialisation de détecteurs technologiques
et état de la centrale
3
Témperature de fonctionnement -10 ÷ +50 °C
Dimensions (lxpxh) 90x72x29 mm
FONCTIONS
Indication des leds:
N° Nom Fonction
1 LED ON (allumé) – Alimentation présente;
OFF (éteint) – Pas d’alimentation;
2 Z1÷Z4
Led indicateur de l’état des zones 1÷4;
Vert : zone fermée
Rouge : zone ouverte
Eteint : zone sans dispositifs acquis
3 Snd
Indicateur de l’état des sirènes.
Vert – zone avec sirène ou communicateur télépho-
nique acquis
Eteint – zone sans dispositifs acquis
Fig.1
Indication entrées et sorties:
N° Nome Fonction
4 AC/DC Alimentation 9÷15Vdc;
4 Out1 Sortie relais (normalement ouvert) indiquant “batterie déchargée”;
4 Out2 Sortie relais (normalement ouvert) indiquant les informations de TAMPER des dispositifs sans-fil et
“dispositif perdu”.
4 In1 Entrée pour le reset des dispositifs sans-fil anti-incendie (donner une référence négative au moins
2 secondes);
4 In2 Entrée pour la commande des sirènes et transmetteurs téléphoniques sans-fil;
4 In3 Entrée pour l’état de la centrale. A connecter seulement en cas d’utilisation de la télécommande
WL04TC pour l’activation et désactivation de la centrale filaire Defender 64
4 Z1÷Z4 Sortie pour la connexion directe des zones à la centrale;
5 TMPR Borne pour la connexion d’un bouton tamper supplémentaire (ex. le tamper de la boîte de jonction);
6 MODE
Réglage du mode de connexion des zones:
a) Jumper inséré – les sorties Z1 :Z4 ont des terminaisons de ligne à “double équilibrage” (seu-
lement centrales Fracarro); dans ce mode sont détectés les alarmes TAMPER des dispositifs
d’alarme et il sont indiqués dans la zone correspondante
b) Jumper pas inséré – les sorties Z1 :Z4 ont terminaison de ligne en mode “normalement fermé”
mode interface universelle)..
DESCRIPTION
L’interface MOD-WL04 est un dispositif universel d’extension des systèmes de sécurité filaire avec les appareils sans
fil du système Defender WL. L’interface communique par une connexion radio bidirectionnelle avec un maximum de
32 dispositifs, notamment: WL04GSM (transmetteur téléphonique), WL04BL 100EX, WL04BL 200EX (barrières à rayons
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
1
4
6
2
3
5

17
FRANÇAIS
infrarouges), WL04IR (détecteur infrarouge), WL04IR EX (détecteur infrarouge externe), WL04MM, WL04MB (contact ma-
gnétique), WL04SEL (sirène), WL04RF (détecteur de fumée) et WL04TC (télécommande). Tous les appareils peuvent être
regroupés dans un maximum de 4 zones par fonctionnalité, localisation, ou une combinaison des deux. Chaque zone a
sa propre sortie configurable comme normalement fermés ou double équilibrage (centrales Fracarro) . Dans le premier
cas sera communiquée uniquement l’information d’alarme; dans le second cas, on aura toutes les informations d’alarme
et d’ouverture contact tamper des dispositifs liés à cette zone. L’interface présente deux sorties supplémentaires pour
la signalisation des événements de «batterie faible», «dispositif perdu» et «tamper» et trois entrées dédiées aux signaux
de reset des détecteurs de fumées et l’activation de la sirène extérieure sans-fil et entrée pour l’état de la centrale pour
la visualisation sur la télécommande WL04TC. De cette façon, la centrale filaire pourra gérer complètement tous les nou-
veaux dispositifs sans fil.
REMARQUE: Vous pouvez connecter jusqu’à 2 sirènes WL04SEL ou une sirène et un transmetteur téléphonique WL04GSM.
CONNEXIONS
L’interface MOD-WL04 peut être utilisée pour ajouter les dispositifs sans-fil de la série DEFENDER WL à une centrale filaire,
même préexistante:
Connexion à une centrale filaire (câblée)
Le même raccordement peut être utilisé avec les centrales qui ont des entrées configurables comme normalement fermées
ou à double équilibrage.
WL04IR
WL04SEL
WL04TC
WL04RF
WL04MM
WL04MB
WL04MM2
WL04MB2
WL04BL100 EX
WL04BL200 EX
WL04IR EX
WL04GSM
MOD-WL04
LED
LED
Sounders
BUZZER
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
COMM
OUT2
TMPR
Jumper
JP
Connexion à une centrale avec des entrées normalement fermées :
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
Jumper
JP
OUT2
MOD-WL04CENTRALE
GND
+B
L4
L3
GND
L2
L1
Si l’on connecte le module MOD-WL04 à une centrale d’alarme filaire qui gère seulement des entrées normalement fermées on doit
retirer le cavalier MODE du module. En utilisant ce type de connexion, sur les bornes des 4 zones disponibles seront présentes
les informations des dispositifs d’alarme; sur la sortie Out2 seront disponibles tous les informations de tamper des dispositifs et
du boîtier et «dispositif perdu».

18
FRANÇAIS
Connexion à une centrale avec des entrées à double équilibrage (seulement sur centrales Fracarro)
Si l’on connecte le module MOD-WL04 à une centrale d’alarme qui gère aussi des entrées à double équilibrage on doit
insérer aussi le cavalier MODE au module. En utilisant ce type de connexion, sur les bornes des 4 zones disponibles seront
présentes les informations d’alarme et de tamper des dispositifs. Dans le cas d’installation d’une sirène ou d’un trans-
metteur téléphonique sans-fil on doit connecter la sortie OUT2 à la centrale pour fournir les informations de tamper de ces
dispositifs.
ATTENTION: si l’on doit installer le MOD-WL04 dans une centrale d’alarme on doit fermer le connecteur TMPR
(Fig.1:5) avec un cavalier.
INSTALLATION
Le MOD-WL04 peut être installé dans une centrale (ex. dans les nouvelles centrales
Defender) ou séparément dans le MOD-BOX.
Procéder à l’installation dans la centrale seulement s’il y a un espace intérieur suffi-
sant et pas de couvercle en métal. Dans tous les autres cas, procéder à l’installation
dans le MOD-BOX. Dans ce dernier cas, on doit connecter le bouton tamper anti-
arrachement au connecteur TMPR. (Fig. 1: 5).
Installation dans les centrales Defender
Pour insérer la carte MOD-WL04, dévisser les deux vis sur le coté supérieur de la
carte de la centrale et incliner la carte vers le bas. Ensuite, fixer la carte de MOD-
WL04 au fond avec les deux vis fournies.
Installation dans le MOD-BOX:
Insérer la carte MOD-WL04 dans le boîtier à l’endroit indiqué sur la figure.
Fixer la carte avec les 4 vis fournies et connecter le bouton tamper anti-arra-
chement (TAMPER-KIT) au connecteur TMPR (Fig. 1 point 5).
Installation:
Pour une bonne installation de l’interface suivre toutes les étapes ci-dessous:
1. Connecter l’interface à la centrale, comme indiqué dans le paragraphe
“Connexions”; fermer ou retirer le cavalier MODE, selon qu’on utilise des
sorties normalement fermées ou double équilibrage;
2. Raccorder le microswitch tamper pour la protection anti-arrachement
de l’interface (kit optionnel);
3. Alimenter l’interface;
4. Tous les LED s’allument en orange pendant quelques secondes;
5. Après ce temps uniquement la led verte reste allumée pour indiquer le
début du mode normal de fonctionnement;
6. Commencer l’acquisition des dispositifs.
ACQUISITION DES DISPOSITIFS
Avant de commencer la procédure on recommande de diviser les dispositifs que l’on souhaite acquérir dans des groupes
en fonction de leur disposition ou typologie pour accroître l’efficacité du système.
Les zones Z1, Z2, Z3 et Z4 sont configurées pour l’acquisition des dispositifs infrarouge (es. WL04IR, WL04IR EX, WL-
04BIR100EX..), magnétiques (WL04MB et WL04MM), détecteurs de fumée WL04RF et télécommandes
WL04TC.
Pour les détecteurs magnétiques WL04MM et WL04MB, le comportement en entrée pour les périphé-
riques externes filaires change en fonction de la zone sur laquelle les appareils sans fil sont acquis.
Si les contacts magnétiques sont acquis sur les zones Z1, Z2 et Z3 on peut connecter à l’entrée supplé-
mentaire (Fig. A, borne 1) des détecteurs à fil RF45 pour la protection des volets (configuration fixe:
4 impulsions dans les 10 secondes).
Si les contacts magnétiques sont plutôt acquis sur la zone Z4 on peut connecter à l’entrée supplémen-
taire (Fig.A point 1) des dispositifs à contact normalement fermé (ex. contact magnétique filaire).
MOD-WL04
A
MOD-WL04

19
FRANÇAIS
ATTENTION: Si l’on veut utiliser le détecteur
magnétique seulement avec l’aimant interne,
sur la zone 4 on doit placer le cavalier sur la
borne 1.
Exemple d’acquisition:
Z1 : Détecteurs infrarouges WL04IR
Z2 : Télécommande WL04TC
Z3 : Contacts magnétiques WL04MB + RF45
Z4 : Contacts magnétiques WL04MB + contact magnétique filaire
Pour les détecteurs WL04MB2 et WL04MM2 on peut faire une acquisition similaire. Le canal pour le contact magnétique peut
être acquis dans toutes les zones. Le canal du détecteur externe RF45 peut être acquis seulement sur les zones Z1, Z2 et Z3.
ATTENTION: l’acquisition de différents types de détecteur dans la même zone produit que l’alarme générée par le
détecteur de fumée WL04RF sera considéré par la centrale comme une alarme générale. On conseille l’acquisition
des détecteurs de fumée dans une seule zone.
Procédure d’acquisition
1. L’interface est en mode de fonctionnement NORMAL, la led vert est allumée (Fig. 1: 1);
2. Accéder au mode d’acquisition en appuyant pendant 3 secondes le bouton LEARN (Fig. 1: 7), la led (Fig.1: 1) s’allumera
en rouge alors que la led Z1 (Fig.1: 2) s’allume en orange;
3. En appuyant le bouton LEARN passer dans la zone (Z1, Z2, Z3, Z4, Snd), dans laquelle on veut reconnaître le dispositif.
L’indicateur de la zone correspondante s’allume en orange; ATTENTION: La sirène sans fil et le transmetteur téléphonique
devront être acquis dans la zone «Snd»
4. Suivre la procédure d’acquisition des dispositifs sans fil;
5. L’interface confirme l’acquisition par une série de 5 BEEP;
6. Appuyer le bouton RESET une fois pour activer ou désactiver l’événement tamper de la zone sélectionnée:
Couleur led zone Z Fonction
Vert Protection tamper désactivée
Orange Protection tamper activée
7. Continuer l’acquisition des dispositifs dans la même zone ou passer à la zone suivante en appuyant sur le bouton LEARN;
8. Pour quitter le mode d’acquisition, appuyer sur le bouton LEARN et entrer dans le mode NORMAL (tous les LEDs sont
allumées en vert).
Mode de fonctionnement :
Par le bouton LEARN on peut accéder a 3 modalités de fonctionnement :
Mode Fonction
NORMAL Les led indiquent l’état des zones
TROUBLE Les led indiquent des possibles problèmes du système (divisés par zone)
LEARN
Acquisition des dispositif dans le système et activation/ désactivation du signal TAMPER des dispositifs
Fonctions des boutons de programmation:
Les boutons LEARN et RESET sont utilisés pour la programmation de l’interface MOD-WL04, et présentent des différentes
fonctions selon le mode d’utilisation:
Bouton Mode Opérations Fonction
LEARN
NORMAL Une pression Entre dans la mode TROUBLE pour révéler les problèmes du
système
Pression pendant 3 seconds Entre dans la mode LEARN pour l’acquisition des dispositifs;
TROUBLE Une pression Entre dans le mode NORMAL;
LEARN Une pression
Passe à la zone suivante Z1, Z2, Z3, Z4 en activant un BEEP.
A la fin du cycle une pression supplementaire restaure le
système en mode NORMAL;
Connect the cables
by a Normally Closed
connection
Connecter les câbles
par une connexion
Normalement Fermée
Collegare i cavi
in un contatto
NC

20
FRANÇAIS
RESET
LEARN
Une pression Active/désactive le signal du TAMPER de la zone sélectionnée
Pression pendant 3 seconds Reset de la zone sélectionnée
FONCTIONNEMENT NORMAL
Pendant le normal fonctionnement les LEDs de l’interface signalent l’état du système selon le tableau suivant.
Led Z1 ÷ Z4 Description
Rouge Au moins un des dispositifs est en alarme
Orange Au moins un des dispositifs a des problèmes de batterie déchargée ou tamper ouvert
Vert Etat normal des dispositifs
Eteint Pas de dispositif acquis
FONCTIONNEMENT DE LA TELECOMMANDE WL04TC
Par défaut, les boutons de la télécommande sont programmés pour effectuer les fonctions suivantes:
Bouton Fonction
Indication de l’état de la zone:
Système activé : 2 sons courts et la led clignote rouge.
Système désactivé : 3 sons courts et la led clignote vert.
Désactivation du système: on active pendant 2 secondes la sortie associée pour la désactivation
du système. Bouton lié à l’état de IN3
Activation du système: on active pendant 2 secondes la sortie associée pour l’activation du
système. Bouton lié à l’état de IN3
Activation ou Désactivation du système : on active pendant 2 secondes la sortie associée pour
l’activation ou désactivation du système. Cette fonction est activée quel que soit l’état dans lequel
se trouve l’entrée In3
Dans la zone où sont acquis les télécommandes on ne doit pas acquérir d’autres dispositifs.
Connexion à une centrale Defender 64:
Pour connecter une centrale filaire à l’interface MOD-WL04 ont doit connecter un câble entre la sortie de la zone où il a
acquis une télécommande (dans notre exemple, Z4) et une ligne de la centrale filaire où sera programmée comme ligne «clé»
de type «impulsif».
Aussi, il établira une connexion entre la sortie P_ON de la centrale et l’entrée « In3 » pour indiquer l’état de la centrale (Si elle
est activée ou désactivée) qui sera ensuite affiché sur la télécommande WL04TC.
AC/DC In1 In2 In3 Z1 Z2 GND Z3 Z4
Jumper
MODE
Z1 Z2 Z3 Z4
LEARN RESET
OUT1
Jumper
JP
OUT2
MOD-WL04CENTRALE
GND
+B
ESC
P_ON
TECN
L2
L1
La sortie « P_ON » doit être programmée comme Stable – Normalement inactive - Événements centrale : centrale insérée.
Le Jumper JP ne doit pas être inséré. La sortie P_ON est réglée par défaut comme normalement inactive.
Pour accéder à ce paramètre il est nécessaire d’activer le menu Avancé de la Defender 64.
Le Jumper JP permet le choix de la reconnaissance du niveau logique de la centrale filaire.
Jumper JP Ajouté Lorsque avec la centrale désactivée on a un niveau logique +12 V sur l’entrée In3
Jumper JP désengagé Lorsque avec la centrale activée on a un niveau logique à 0V sur l’entrée In3 (d’une
sortie collecteur ouvert)