Infrared barrier
according to
UNI 8612
series:
FE - FEP
FI - BF
GB F
QUESTO LIBRETTO È DESTINATO SOLO ALL'INSTALLATORE.
L'installazione dovrà essere effettuata solamente da personale professionalmente qualificato in conformità a quanto previsto dalla legge n°
46 del 5 marzo 1990 e successive modifiche ed integrazioni e nel pieno rispetto delle norme UNI 8612.
2
!!
!!
I
1° coppia
1st pair
1er couple
1. Paar
1ª pareja
- Installazzione con alimentazione continua
- Installation with direct current
- Installation avec alimentation continue
- Installation mit Gleichstrom
- Instalación con corriente continua
Fig. 2
- Installazzione con alimentazione alternata
- Installation with alternating current
- Installation avec alimentation alternée
- Installation mit Wechselstrom
- Instalación con corriente alterna.
Fig. 1
Centrale
Central
Centrale
Steuereinheit
Central
2° coppia
2nd pair
2ème couple
2. Paar
2ª pareja
1° coppia
1st pair
1er couple
1. Paar
1ª pareja
2° coppia
2nd pair
2ème couple
2. Paar
2ª pareja
Centrale
Central
Centrale
Steuereinheit
Central
GB
DESCRIZIONE:
I dispositivi della serie FE - FEP - FI - BF sono composti da un trasmettitore TX e da un
ricevitore RX. La barriera si realizza tramite l'emissione di luce all'infrarosso modulato.
Grazie alle sue dimensioni ridotteFE - FEP - BF può essere installata a parete senza più
necessità di fori o scanalature, non ha bisogno di alcuna regolazione di centratura. Il
perfetto allineamento della barriera viene visualizzato da un led sul ricevitore.
FI è stata disegnata per poter essere incassata a muro e effettuare le regolazioni di
allineamento con grande facilità grazie anche alla disponibilità di 2 test point.
FE-FEP- FI -BFsonostate progettate rispettando tutte le normativevigenti(UNI8612),
ildesigne i materiali impiegati la rendono particolarmenteaffidabile eduraturanel tempo.
POSSIBILITÀ DI IMPIEGO
Vieneimpiegataneisistemidiallarmeinternioesterni,per laprotezionediporteecancelli.
L'impiego e l'uso di questa apparecchiatura deve rispettare rigorosamente le norme di
sicurezza vigenti.
IL COSTRUTTORE NON PUÓ CONSIDERARSI RESPONSABILE PER EVENTUALI
DANNI CAUSATI DA USI IMPROPRI, ERRONEI ED IRRAGIONEVOLI.
INSTALLAZIONE
La nuova generazione di dispositivi dispone di un circuito di sincronismo che permette di
poter montare due coppie anche vicinissime senza che si interferiscano tra di loro.
Per poter usufruire di questa caratteristica:
- TAGLIARE il ponticello "A" (fig. 6) su entrambi i TX.
- ALIMENTARE le due coppie in corrente alternata, invertendo le polarità fra la prima e
la seconda coppia (fig. 1).
Il funzionamento sincronizzato può essere usato anche su una singola coppia, ottenendo
un più preciso funzionamento e un minor consumo di corrente.
N.B.: Nel caso l'alimentazione sia continua (c.c.) la funzione di sincronismo viene
annullata quindi è necessario installare i due ricevitori uno opposto all'altro come
pure i trasmettitori (fig. 2).
Data la elevata potenza del raggio emesso dal trasmettitore, quando la distanza dal
ricevitoreéinferiorea4-5mtpossonoavveniredeifenomenidiriflessioneconoggettinelle
vicinanze, compromettendone il corretto funzionamento.
Per risolvere questo problema sono previsti 2 livelli di portata.
1) 15 MT (STANDARD)
2) 30 MT (TAGLIARE IL PONTICELLO "B" SUL RICEVITORE fig. 6).
N.B.: La portata si può ridurre del 50 % in presenza di fenomeni atmosferici: nebbia
pioggia, polvere ecc.
Un'altra caratteristica della nuova generazione é l'alimentazione.
Grazie a un nuovo sistema di stabilizzazione é possibile alimentare i fotodispositivi
indifferentemente con una alimentazione che varia da 12 Vcc/ca a 30 Vcc/ca.
Itrasmettitorieiricevitoridovrannoesserefissatisullostessoassegeometricoeallastessa
altezza dal suolo, frontalmente.Per togliere il coperchio fare leva con un cacciavite sulla
ferritoia posta in basso (FE - FI).
Fissare la barriera fig. 3 - 4 - 5.
Effettuare i collegamenti come in fig. 1 o 2.
FE - FEP - BF:alimentare la barriera a 12 - 24 Vcc/ca, se la barriera risulta correttemente
collegata e allineata il led rosso sul ricevitore sarà spento.
FI: alimentarelabarriera,effettuarel'allineamento con l'ausilio di un tester postoa3-5Vcc
fondo scala: inserire i rispettivi puntali nelle sedi del ricevitore, rispettando la polarità
contrassegnata, agire sulle 3 viti di regolazione sia sul trasmettitore che sul ricevitore fino
ad ottenere la massima tensione sul tester. (valore minimo da ottenere 0,3 Vcc.
Qualoranon ci fosse la possibilità di utilizzare un tester,un ulteriore controllo di centratura
puòesserevisualizzatotramitel'appositoledpostosulricevitore,illedsarà +o- illuminato
asecondadellacentratura,selabarrierarisulteràallineataecentratailled avrà lamassima
intensità luminosa.
VERIFICA DI FUNZIONAMENTO
FE - FEP - BF: Interrompere il fascio più volte controllando la commutazione del relé e
l'accensione del led rosso sul ricevitore. - non allineato: LED ROSSO ACCESO
- allineato: LED ROSSO SPENTO
Inserireilfrontalinosullabarrieraverificandosempre il perfetto funzionamento. Con il filtro
di attenuazione inserito, la barriera deve essere ancora perfettamente funzionante.
Il filtro simula condizioni metereologiche avverse (nebbia, pioggia ecc.).
Togliere quindi il filtro di attenuazione al termine delle verifiche.
FI: interrompere più volte con una mano il fascio. - Il led rosso si spegne.
- Il relé commuta.
Inserire il frontalino sulla barriera, verificando sempre il perfetto funzionamento. Se si
dovesse installare la barriera a distanze superiori ai 30 mt. (fino a 100 mt.) é possibile
inserire una lente nell'apposito incastro (vedi fig. 5).
Per facilitare l’installazione la NICE fornisce gli accessori:
- COF : olonnina in metallo H 50 cm. FE - FEP
- PCF : piastra di fondazione per colonnina FE - FEP
- COB : colonnina in metallo H 50 cm. BF
- PCB : piastra di fondazione per colonnina BF
- CPI : contenitore plastica a murare FI
DESCRIPTION:
The devices in the series FE - FEP - FI - BF are composed of a TX transmitter and an RX
receiver. The barrier is made through the emission of modulated infra-red light. Thanks to
their reduced dimensions, FE - FEP - BF can be wall mounted without it being necessary
to make any holes or grooves, and it needs no centring adjustment. Perfect alignment of
the barriers can be visualized by a LED on the receiver.
FIhasbeendesignedtoberecessedinthewallandalignmentisadjustedextremelyeasily,
thanks also to the 2 test points available.
FE -FEP -FI -BF have been designed inconformitywithallstandardsinforce(UNI8612),
theirdesignandthematerials usedformanufacture meanthatthey areparticularlyreliable
and long lasting.
RANGE OF USE
They are used in indoor or outdoor alarm systems, to protect doors and gates. These
devices must be utilized and used in strict compliance with the safety regulations in force.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ANY DAMAGE
CAUSED BY IMPROPER, ERRONEOUS OR UNREASONABLE USE.
INSTALLATION
The new generation of devices are equipped with a synchronous circuit which allows two
pairs to be installed extremely close to each other without any interference between them.
To take advantage of this facility:
CUT the jumper “A” (fig. 6) on both TX;
SUPPLY the two pairs with alternating current, inverting the polarity between the first
and the second pair (fig.1).
Synchronousoperation mayalsobeusedon asinglepair,in order toobtainmoreaccurate
operation and consume less power.
N.B.: In the event of direct current (DC) supply synchronous operation is cancelled
anditisthereforenecessarytoinstallthetworeceiversandtransmittersonopposite
sides from each other (fig. 2).
As the beam emitted by the transmitter is extremely powerful, when there is a distance of
less than 4-5 m from the receiver correct operation could be affected by phenomena of
reflection with nearby objects.
To solve this problem 2 levels of range are possible:
1) 15 M (STANDARD)
2) 30 M (CUT JUMPER “B” ON THE RECEIVER - FIG. 6)
N.B.: Range may be reduced by 50% by bad weather conditions, such as fog, rain,
dust, etc.
Another feature of the new generation is the power supply.
Thanks to a new stablisation system, it is possible to supply the photoelectric devices
indifferently with a voltage which varies from 12V DC/AC to 30V DC/AC.
The transmitter and receiver must be fixed on the same geometrical axis and at the same
heightfrom theground,opposite eachother. Toremovethe coverinserta screwdriverinto
the slot positioned on the lower part and exert pressure (FE - FI).
Fix the barrier - figs. 3, 4, 5.
Make the connections as in figs. 1 or 2.
FE - FEP - BF: supply the barrier with 12 - 24V DC/AC; if the barrier is correctly connected
and aligned the red LED on the receiver will be off.
FI: supply the barrier, align with the aid of a tester positioned at 3-5V DC bottom of scale:
introducethecorrespondingprodsinthereceiverseats,observingthepolaritymarked,turn
the 3 adjustment screws on both the transmitter and the receiver until maximum voltage is
obtained on the tester (minimum value to obtain 0.3V DC).
Shoulditnotbepossibletouseatester,centringcanbecheckedbyobservingthe specific
LED on the receiver: the LED will be lit to a greater or lesser extent according to the level
of centring, if the barrier is aligned and centred the LED will be brightly lit.
CHECKING OPERATION
FE - FEP - BF: Interrupt the beam several times checking that the relay switches over and
that the red LED on the receiver lights up.
not aligned: RED LED ON
aligned: RED LED OFF
Fit the front to the barrier, checking that it still operates perfectly. With the attenuation filter
fitted, the barrier must still function perfectly.
The filter simulates bad weather conditions (fog, rain, etc.).
Remove the attenuation filter after checking.
FI: interrupt the beam several times with your hand: the red LED is switched off;
the relay switches over.
Fit the front to the barrier, checking that it still operates perfectly.
If the barrier is installed at a distance of over 30 m (up to 100 m) a lens may be fitted in the
specific housing (see fig. 5).
NICE supplies the following accessories to facilitate installation:
- COF : metal column H 50 cm FE - FEP
- PCF : base plate for column FE - FEP
- COB : metal column H 50 cm BF
- PCB : base plate for column BF
- CPI : masonry plastic container FI
12÷24 Vcc
12÷24 Vca
5
CARATTERISTICHE TECNICHE
RICEVITORE
PORTATA
ALIMENTAZIONE
LUNGHEZZA D'ONDA
FREQUENZA INFRAROSSO
ASSORBIMENTO
TEMPERATURA DI FUNZIONAMENTO
PORTATA RELE'
DIMENSIONI
I
La NICE spa si riserva il diritto di apportare modifiche in qualsiasi momento e senza preavviso alcuno.
FEP FE BF
38
64
77
32
77
54
84
27
64
: 15mt STANDARD - 30mt tagliando l'apposito ponticello sul RX
: FI- estendibile a 100 mt con apposita lente LE
: La portata si può ridurre del 50% in presenza di fenomeni atmosferici: nebbia, pioggia, polvere ecc.
: 12÷24 Vcc-ca
: 880 nm.
: 540 Hz
: RX 20 mA - TX 35 mA
: - 20° + 70° C
: 1 A MAX 24 V.
: 77X64X32 FE - 77X64X38 FEP - 54X84X27 BF - 80X77X64 FI (la parte incassabile: ø 60)
THECNICAL CHARACTERISTICS
RECEIVER
RANGE: : 15 m STANDARD - 30 m by cutting the specific jumper on RX
: FI: extensible to 100 m with specific LE lens
: Range can be reduced to 50% in bad weather conditions: fog, rain, dust, etc.
POWER SUPPLY : 12 to 24V DC/AC
WAVE LENGTH : 880 Nm
INFRA-RED FREQUENCY : 540 Hz
INPUT : RX 20 mA - TX 35 mA
OPERATING TEMPERATURE : - 20°C to 70°C
RELAY OUTPUT : 1A max 24V
DIMENSIONS: : 77X64X32 FE - 77X64X38 FEP - 54X84X27 BF - 80X77X64 FI (recessing part: diam. 60)
NICE spa reserves the right to make modifications at any time without prior notice.
CARATTERISTIQUES TECNIQUES
RECEPTEUR
PORTEE:
ALIMENTATION
LONGUEUR D’ONDE
FREQUENCE INFRAROUGE
ABSORPTION
TEMPERATURE DE FONCTIONNEMENT
PORTEE RELAIS
DIMENSIONS
F
: 15 m standard - 30 m en coupant le pontet prévu à cet effet sur RX
:FI - peut s’étendre à 100 m avec la lentille LE prévue à cet effet
: La portée peut se réduire de 50% en présence de phénomènes atmosphériques: brouillard, pluie, poussières, etc.
: 12÷24 Vcc-ca
: 880 nm.
: 540 Hz
: RX 20 mA - TX 35 mA
: - 20° + 70° C
: 1 A MAX 24 V.
: 77X64X32 FE - 77X64X38 FEP - 54X84X27 BF - 80X77X64 FI (la partie encastrable: Ø 60)
La ste NICE spa se reserve le droit d'apporter toutes modifications a tous moments sans aucun preavis.
GB

This manual suits for next models

3

Other Nice Security System manuals

Nice HSSO1 Technical specifications

Nice

Nice HSSO1 Technical specifications

Nice HSSO User manual

Nice

Nice HSSO User manual

Nice HSMO - HSA1 User manual

Nice

Nice HSMO - HSA1 User manual

Nice HSCU1 Technical specifications

Nice

Nice HSCU1 Technical specifications

Nice HSSOC User manual

Nice

Nice HSSOC User manual

Nice HSDIW01 User manual

Nice

Nice HSDIW01 User manual

Nice numera 2GIG 2GIG-PHB1-345 User manual

Nice

Nice numera 2GIG 2GIG-PHB1-345 User manual

Nice Linear IV200 Series User manual

Nice

Nice Linear IV200 Series User manual

Nice HSDIW01 User manual

Nice

Nice HSDIW01 User manual

Nice M3BAR Technical specifications

Nice

Nice M3BAR Technical specifications

Nice HSSOC User manual

Nice

Nice HSSOC User manual

Nice MyNice MNS User manual

Nice

Nice MyNice MNS User manual

Popular Security System manuals by other brands

Mercury 1st Mate manual

Mercury

Mercury 1st Mate manual

Vigilant MX1 Operator's manual

Vigilant

Vigilant MX1 Operator's manual

Defender EL00017 quick start guide

Defender

Defender EL00017 quick start guide

ADT SafeWatch 3000 user guide

ADT

ADT SafeWatch 3000 user guide

Homa AL3 Original instruction manual

Homa

Homa AL3 Original instruction manual

SecurityMan Air-AlArm1 user manual

SecurityMan

SecurityMan Air-AlArm1 user manual

Goscam 8104JR user manual

Goscam

Goscam 8104JR user manual

Redarc HBA1224 instruction sheet

Redarc

Redarc HBA1224 instruction sheet

PNI House PTZ1350 user manual

PNI

PNI House PTZ1350 user manual

TeleCare24 Fall Alarm Plan user guide

TeleCare24

TeleCare24 Fall Alarm Plan user guide

SPY RF ALARM user manual

SPY

SPY RF ALARM user manual

Interlogix Simon XT installation guide

Interlogix

Interlogix Simon XT installation guide

Solon AL00009 manual

Solon

Solon AL00009 manual

Partizan Outdoor Wireless Kit LCD 1MP 4xIP manual

Partizan

Partizan Outdoor Wireless Kit LCD 1MP 4xIP manual

Pfannenberg BExBG05D-P instruction manual

Pfannenberg

Pfannenberg BExBG05D-P instruction manual

Bosch GVS1000 Operation manual

Bosch

Bosch GVS1000 Operation manual

Pyronix ENFORCER V11 Extended user guide

Pyronix

Pyronix ENFORCER V11 Extended user guide

EDM Solution-8 Operator's manual

EDM

EDM Solution-8 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.