Franka Emika Panda Instruction Manual

Franka Emika GmbH ©October 2018 1
USER HANDBOOK
PANDA
ENG

Franka Emika GmbH © October 2018
2

Franka Emika GmbH ©October 2018 3
ORIGINAL USER HANDBOOK
© Copyright 2018
Franka Emika GmbH
Infanteriestraße 19
80797 Munich
Germany
This document and extracts of it may only be reproduced or made available to third
parties with the explicit authorization of Franka Emika GmbH.
The content of this document has been carefully checked against compliance with the
hardware and software described. However, discrepancies cannot entirely be ruled out,
which is why we assume no liability for complete compliance.
In the interest of our customers, we reserve the right to undertake improvements and
corrections to hardware, software and documentation at any point in time without notice.
The English documentation is the ORIGINAL DOCUMENTATION. Other languages are
translations of this original document.
RELEASE VERSION: 1st of October 2018

Franka Emika GmbH © October 2018
4
LEGAL FRAMEWORK
• About this User Handbook
• Panda - CE out of the box soluons
• Noce of liability
• Sta
• Intended purpose of Panda
• Panda’s conformies
INTRODUCTION
• Terms
• About us - Franka Emika GmbH
• This is Panda
- The Panda Power Tool
- Some features
- Equipment overview
- Scope of delivery and addionally
required equipment
SPECIFICATIONS
• Technical specicaon
PRODUCT CONFORMITY
• Declaraon of Incorporaon
- Control with Arm
• Declaraon of Conformity
- Hand
• Further statements
8
20
40
48
CORRECT SITE OF INSTALLATION
• Ambient condions
- Arm and Hand
- Control
54
CONTENT OVERVIEW

Franka Emika GmbH ©October 2018 5
DELIVERY AND TRANSPORT
• Delivery & transport
• Handling & liing
MOUNTING AND INSTALLATION
• Preparing the installaon site
• Unpacking Panda
• Mounng the Arm
• Mounng the Hand
• Unpacking and mounng the Control
• Wiring and electrical installaon
SAFETY CONCEPT
• Sta
• Dangers that Panda may present
• Hazardous and safe areas
• Emergency stop installaon
• Stopping mechanisms
• Fail-safe safety locking system
- Manually moving the Arm in case of emergency
• Operang modes of Panda
- Teach Panda a task
- Step back & check - Check whether the task is being executed correctly
- Let Panda run a task
run your task - automacally
run your task - interacvely
• Carrying out a risk analysis
• Praccal ps for usage and posioning of Panda
• Labeling on the equipment
62
86
90

Franka Emika GmbH © October 2018
6
START-UP
• Switching on
• Connecng a user interface device
• Soware setup
• Guiding
• Tesng the emergency stop system
• Switching o
INTERACTING & PROGRAMMING
• Direct human-robot interacon
• Creang a task in Desk
- Desk overview
- An App for everything
- Conguring Apps
• Execung the task
- Manual unlocking of Arm and Hand
in cases of emergency
MAINTENANCE, SERVICE & SUPPORT
• Cleaning
• Updates
• Service & Support
- Troubleshoong
• Shut-down, storage and disposal
RIGHTS OF USE & PROPERTY RIGHTS
• Idencaon
• Rights of use and property rights
102
114
126
132
CONTENT OVERVIEW

Franka Emika GmbH ©October 2018 7

Franka Emika GmbH © October 2018
8
Safety
LEGAL FRAMEWORK
About this User Handbook
Before installaon, start-up and operaon of the device carefully read this manual
and any addional documentaon related to it. In parcular, take note of the safe-
ty instrucons and general indicaons, which are marked as follows:
Indications
DANGER indicates that nonobservance of instructions or measures will lead
to death or severe injury.
WARNING indicates that nonobservance of instructions or measures may
lead to death or severe injury.
CAUTION indicates that nonobservance of instructions or measures may lead
to minor or moderate injury.
Warnings marked with a yellow exclamation mark indicate general safety-
related information.
SAFETY INSTRUCTION indicates processes that need to be strictly observed.
A text section marked with NOTICE indicates that nonobservance of instruc-
tions or measures may result in damage other than physical injury.
Indicates where further information can be obtained.
DANGER
WARNING
CAUTION
SAFETY -
INSTRUCTION
NOTICE

Franka Emika GmbH ©October 2018 9
The present Panda system is intended exclusively for use as described in
this User Handbook.
Panda has been developed according to the quality standards of ISO 9001.
The producon of our devices is carried out in a producon company cered
according to ISO 9001. A risk assessment according to ANSI/ ISO 12100 has
been carried out through the course of development and is the basis for Panda
and this User Handbook. Misuse can, nevertheless, cause danger to life and
limb and impairments and damages to the robot and other material assets.
Therefore:
• Panda may only be used in perfect technical condion, for its intended
purpose and within the technical specicaons and operang condions,
with awareness of safety and possible dangers
• Use must comply with the instrucons of this User Handbook
• Malfuncons that may impair safety need to be reced immediately
• Modicaons of Panda are not permissible
The producer is not liable for damages caused by misuse as exemplied above.
This manual contains product descripons for the Panda system components Arm, Control and Hand (hereinaer the system
is also simply referred to as Panda).
If you have purchased a Panda – CE out of the box soluon, please be sure to take account of the supplementary documen-
taon including the CE check list provided, in addion to the present basic documentaon. The CE out of the box soluons
have already been assessed by Franka Emika as to their compliance with the Machinery Direcve so that you as a user merely
need to follow and conrm the steps in the CE check list. In this way, you can use Panda as an assembled machine according
to the EU Machinery Direcve 2006/42/EC. Find out more about CE out of the box soluons at:
www.franka.de/apps/

Franka Emika GmbH © October 2018
10
Operator
Researcher
Insufficiently qualified staff may cause severe damage to persons or ma-
terial damage to machinery and equipment!
Therefore:
• All persons that may enter the operang area of the Arm need to have
read and understood this documentaon, in parcular the chapter on
safety. They need to be able to use their knowledge and experience to
understand any risks the robot system may present and be adequately
prudent in their behavior.
• The operator has to inform these persons explicitly about the limitaons
and restricons of Panda.
WARNING
The operator of Panda can be e.g. the entrepreneur, director of the instute, the
employer or a delegate responsible for the use of Panda. The operator is respon-
sible for compliance with regulaons of occupaonal health and the operaonal
safety ordinance (e.g. for the US: e.g. OSHA regulaons and public laws).
These include the following things:
• The operator must fulll his monitoring obligaons.
• The operator must ensure that all sta members working with Panda are
suitably qualied to do so and have been informed about the possible
dangers Panda may present.
• The operator must provide training and instrucons in given intervals in
order to create and consolidate risk awareness.
In this regard, we refer you to the Franka Academy, where appropriate train-
ing courses on the handling of Panda are oered.
https://www.franka.de/training/
User of the Franka Control Interface (hereinaer also referred to as FCI) shall
also take note of further product documentaon on the use of the FCI https://
www.github.com/frankaemika/
LEGAL FRAMEWORK

Franka Emika GmbH ©October 2018 11

Franka Emika GmbH © October 2018
12
Intended purpose of Panda
The producer is not liable for damages caused by misuse. All the risk is borne
by the operator alone.
If applicable, already exisng, internal operang policies of the operator, such
as trainings, safety instrucons, operang policies and, possibly, country-
specic restricons are to be taken into account and respected.
The Arm and its control system (hereinaer: Control) with/without mounted
end-eector (e.g. Franka Emika’s Hand) are intended exclusively for industrial
use and use in research. The system may be applied only in the ambient and
operang condions described in this manual for the tasks of:
• tesng and inspecon
• handling
• mounng
When Panda is used for robocs research and the Franka Control Interface (FCI)
is acve, the intended purpose of Panda also includes:
• researching and tesng path planning algorithms
• researching and tesng control algorithms
• researching and tesng gripping strategies
• researching and tesng interacon scenarios
• researching and tesng machine learning algorithms
As long as the FCI is acve, Panda may not be used for commercial purposes.
Intended purpose - Panda
Intended purpose -
Panda research
LEGAL FRAMEWORK

Franka Emika GmbH ©October 2018 13
Modifications of Panda (e.g. fittings, creation of drill holes, etc.) may lead to
damage to the system. This is considered misuse and will lead to the loss of
warranty and liability claims.
Any applicaon dierent to the intended purpose is considered to be misuse and
is not permied. This includes:
• transportaon of people and animals
• use outside of the specied operang limits
• use as climbing assistance or leaning against the roboc arm
• use in potenally explosive areas
• use below ground
• handling of radioacve objects
• use outdoors
• use as a medical product
• use as a service robot arm e.g. for care of the elderly
• use in the vicinity of children
Misuse

Franka Emika GmbH © October 2018
14
EU Machinery Direcve – Panda
– CE out of the box soluons
If you have purchased a Panda – CE out of the box soluon you are now the
proud owner of the rst smart assistant of its kind! Similar to any power tool
bought at a hardware store you can operate Panda aer a short check as a com-
plete machine according to the EU Machinery Direcve 2006/42/EC. It has the
corresponding CE marking and there is no need for a risk assessment, you can
get started straight away.
For CE out of the box soluons Franka Emika has already carried out the confor-
mity assessment procedure according to the Machinery Direcve. As long as the
user operates the CE out of the box soluon according to the intended purpose,
Franka Emika’s conformity assessment will remain valid. In order to verify that
Panda is being operated under the ambient and operang condions dened
in the manual, every CE out of the box soluon contains a CE check list. If all
quesons can be answered with “yes”, the enclosed declaraon of conformity is
valid and Panda can be used straight away.
LEGAL FRAMEWORK
user’s tasks
its

Franka Emika GmbH ©October 2018 15
EU Machinery Direcve – Panda
System Components
If one or several of the quesons on the CE check list for the CE out of the box
soluon have been answered with “no” or if you have not purchased a CE out of
the box soluon, the Panda system components (Arm, Control, Hand) are to be
assessed independently by the user as to their compliance with the Machinery
Direcve.
In this case the user needs to carry out a risk assessment independently based on the
contents and correct applicaon of the instrucons in this manual. The user is respon-
sible for implemenng the necessary measures resulng from this assessment before
operang the system and for declaring conformity with the Machinery Direcve.
The corresponding declaraon of incorporaon and the declaraons of conformity
are provided in the chapter: Product Conformity.
The operator is rsponsible for operang Panda and its possible integraon into
a larger installaon or into a larger research apparatus.
The operator is furthermore solely responsible for carrying out a risk assess-
ment based on the contents of this user handbook and implemenng and en-
suring appropriate or necessary measures (e.g. consturconal or oganizaonal
measures) resulng from it.
its

Franka Emika GmbH © October 2018
16
General safety measures In addition to the “general safety measures” described here, this documen-
tation includes information on safety during installation, start-up, operation,
maintenance, reparation and disposal, which must also be noted.
The system component Control in connecon with the Arm is CE-compliant
according to:
• to EMC Direcve (2014/30/EC)
• and to the Low Voltage Direcve (2014/35/EC).
The Hand is CE-compliant according to:
• to the Machinery Direcve (2006/42/EC)
• and to EMC Direcve (2014/30/EC)
For the declaraons of conformity see chapter: Product Conformity
Control, Arm, Hand and accessory parts are exempt from regulaons according
to RoHs, REACH and WEE direcves. Nevertheless, our products comply with
the requirements according RoHS.
For the corresponding conrmaon, see Chapter/Product Conformity/Further
Declaraons.
EMC Direcve
Low-Voltage Direcve
RoHS, REACH, WEEE
LEGAL FRAMEWORK
FCC In addion to the European EMC Direcve, Panda is also compliant to the US
regulaon FCC rule 47 CFR part 15 for electromagnec compability.
OSHA Within the United States of America, the operator is solely responsible to be
com pliant to the OSHA regulaons (29 CFR part 1910) and to be compliant to
public laws. Supporng the operator’s evaluaon we have added an addional
statement of conformity.
Herein we declare for eaxample that our power supply is NRTL cered by UL,
and the usage of internaonal Standards.
For the corresponding conrmaon, see chapter: Product Conformity/ Further
Informaon.

Franka Emika GmbH ©October 2018 17
WARNING
Funconalies and Features of
Various Safety Levels
Panda oers funconalies and features of various safety levels. They are
described in the chapter “Safety Concept/ Operang modes of Panda”,
where a clear disncon is made between funconalies that are safe to
use and others which are only available as features. These features are
not classied as safety funcons according to EN ISO 13849-1. You may
therefore NOT rely on the availability of these funconalies. When they
are used, dangerous and uncontrolled movements of the roboc arm are to
be expected at any given moment! Such a malfunconing is to be regarded
as extremely rare and will only occur under very unfavorable condions.
Therefore, maintaining aenon focused and alert for any malfunconing
presents a challenge. The menoned movements can lead to risks of crush-
ing, shearing, impact, puncture or penetraon and may cause severe injury.
Therefore:
• When using these features the operator is solely responsible for con-
ducng a risk assessment based on the contents of this manual and
subsequently implemenng appropriate measures (construconal or
organizaonal measures).
• It needs to be ensured that the user is aware that the menoned fea-
tures could be not available.

Franka Emika GmbH © October 2018
18
Perfect condition
Modifications
Disruptions
Panda may only be used in perfect condition, according to its intended
purpose and with possible dangers and risks in mind. Misuse can cause
personal and material damage. The manufacturer is not liable for damages
caused by misuse.
The Arm is equipped with an ISO end eector ange. Dierent end eectors
can be mounted on it. In our risk assessment, we have only
considered our own gripper (Hand). Should other end eectors be mounted,
the operator is responsible for carrying out the appropriate risk assessment
and implement the corresponding measures. We are not liable for damages
caused by mounted equipment.
Apart from mounng end eectors, modicaons to Panda are not allowed.
Such modicaons may include:
• drilling holes, screw threads in the casing structures (modicaon
of the load carrying capacity of the casing, polluon or damage to
internal parts caused by chippings, etc.)
• varnishing (modicaon of drain-o capacity, contaminaon of the fail-
safe safety locking systems caused by entering of varnish, heang, etc.)
• enwrapping the roboc structure (prevenon of adequate convecon,
etc.)
• opening the devices (if devices are opened by the customer we will
assume that a modicaon has been carried out by the customer)
• etc.
If Panda indicates possible malfuncons or the user noces malfuncons,
these need to be reced before connuing operaon. Unl malfuncons
have been reced the system must remain shut down.
WARNING
WARNING
WARNING
LEGAL FRAMEWORK

Franka Emika GmbH ©October 2018 19
Dead weight
The Arm weighs approx. 18kg, the Control approx. 7kg, the Hand approx. 1kg.
Due to the dead weight and partly geometric design (e.g. mounting flanges),
lifting and handling the device can lead to back injury, and, should it fall, to
serious injury to fingers, hands, toes and feet.
Therefore:
• always wear personal protective equipment (e.g. safety shoes), when
transporting, mounting or demounting these devices
• the devices must be placed such as to prevent tilting or sliding
• when lifting or handling the devices, pay attention to lift correctly (lift
with your legs, not your back)
WARNING
The Arm contains sensive mechanical and mechatronic components. These
can be decalibrated or damaged due to wrong handling or misuse!
Therefore:
• The Arm may only be handled, lied and transported at the points
indicated in this manual in order to avoid overstressing the joints of the
Arm
• The Arm is to be handled gently even when set-up and switched on
or o. If, for example, the arm is moved by force when in stopped and
locked state, an internal safety system is triggered and will cause a
momentary slipping of internal parts. This slipping causes decalibraon
and damage to the Arm
The Arm and Control contain sensive electromechanical components. These
can be decalibrated or damaged by shock!
Therefore:
• Avoid shocks or seng the device down roughly.
• Always store and transport devices in their original packing, even
during transport inside buildings
NOTICE
NOTICE

Franka Emika GmbH © October 2018
20
INTRODUCTION
• Terms
• About us - Franka Emika GmbH
• This is Panda
- The Panda Power Tool
- Some features
- Equipment overview
- Scope of delivery and addionally
required equipment
Other manuals for Panda
1
Table of contents
Other Franka Emika Robotics manuals
Popular Robotics manuals by other brands

AndyMark
AndyMark TileRunner Original 6WD user guide

QB Robotics
QB Robotics qb SoftClaw General manual

SuperDroid Robots
SuperDroid Robots TP-262-000 quick start guide

Universal Robots
Universal Robots UR10 Service manual

Pro's Kit
Pro's Kit GE-895 Assembly & instruction manual

be bionic
be bionic steeper Technical manual