Franklin PUMPTEC-PLUS Installation guide

PUMPTEC-PLUS
Pump Protection System
Installation and Operating Guide

s WARNING
!
s WARNING
!
Before Getting Started
Read and follow safety instructions. Refer to product data plate(s) for additional operating
instructions and specications.
s CAUTION
!
s CAUTION
!
RISK OF ELECTRIC SHOCK - This pump is supplied with a grounding conductor and grounding type
attachment plug. To reduce risk of electric shock, be certain that it is connected only to a properly
grounded, grounding-type receptacle. Disconnect power before working on or around the Inline system.
Do not use the Inline system in swimming areas.
This equipment should be installed by technically qualied personnel. Failure to install it in compliance
with national and local electrical codes and within Franklin Electric recommendations may result in
electrical shock or re hazard, unsatisfactory performance or equipment failure. Installation information
is available through pump manufacturers and distributors, or directly from Franklin Electric at our toll-
free number 1-800-348-2420.
This equipment must not be used by children or persons with reduced physical, sensory or mental
abilities, or lacking in experience and expertise, unless supervised or instructed. Children may not use
the equipment, nor may they play with the equipment or in the immediate vicinity.
If the power cord is damaged, it must only be replaced by qualied personnel.
• Keep work area clean, well-lit, and uncluttered.
• Keep safety labels clean and in good condition.
• Wear safety glasses while installing or performing maintenance on pump.
• Do not run pump dry. Fill pump with water before starting or pump will be damaged.
• Make sure all ELECTRICAL POWER IS OFF before connecting any electrical wires. Wire Inline
Pressure Boosting System for correct voltage. Follow all pump wiring instructions provided in the
"Wiring" section of this manual.
s WARNING
!
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for
one of the following signal words and be alert to the potential for personal injury:
s WARNING
!
DANGER
s WARNING
!
NOTICE
warns about hazards that will cause serious personal injury, death or major
property damage if ignored.
warns about hazards that can cause serious personal injury, death or
major property damage if ignored.
warns about hazards that will or can cause minor personal injury or major
property damage if ignored.
indicates special instructions which are imported but not related to hazards.
Carefully read and follow all safety instructions in this manual and on pump.

Table of Contents
Before Getting Started ............................................................2
Features ........................................................................4
Installation ......................................................................5
Operation .......................................................................8
Troubleshooting During Installation .................................................11
Troubleshooting After Installation...................................................12

4
PUMPTEC-PLUS Pump Protection System
Installation Information
Features
Technical Specications
Horsepower Rating 1/2 to 5 hp
Operating Voltage 230 VAC*
Operating Frequency 60 Hz
Power Consumption 5 Watts
Operating Termperature Range -15 °F to 140 °F
Over/Under Voltage Trip ±10%
Over/Underload Trip ±25%**
Rapid Cycle Trip 4 starts/min
Trip Response Time 2.5 sec
Automatic Restart Time 1 min to 4hr 15 min
Over/Under Voltage Retry 2 min
Calibration Abort Time 3 min
Calibration Memory 10 years
Contactor Rating 5 hp
s WARNING
!
WARNING To avoid possible fatal shock, disconnect power at the main power
panel before installing, wiring or servicing Pumptec-Plus.
■Over/Underload Protection ■Snapshot Calibration
■Over/Under Voltage Protection ■Continuous Calibration Memory
■Rapid Cycle Detection ■Works With All Single-phase Motors
■Fault Indicator Lights ■Transient Surge Protection
■Run Indicator Light ■UL Listed (E104778)
■5 hp Contactor ■Adjustable Automatic Restart Timer
■Heavy-Duty Terminal Blocks ■Toll-Free Customer Support (800-348-2420)
s WARNING
!
CAUTION
This product does not replace a motor control box or the need for
motor overload protection. Installation and motor overload protection
should be in accordance with National Electrical Code Article 430 or in
accordance with motor manufacturer’s recommendations.
NOTE: This unit requires calibration before operation. Calibration is described in step 7 of the
installation instructions.
* 220 Volt, 50 Hz for model #5800060500
** Percent of load time of calibration SNAPSHOT

PUMPTEC-PLUS Pump Protection System
5
Timer Switch Settings
0) Manual Reset
1) 1 Minute
2) 2 Minutes
3) 4 Minutes
4) 8 Minutes
5) 16 Minutes
6) 32 Minutes
7) 1 Hour 4 Minutes
8) 2 Hours 8 Minutes
9) 4 Hours 16 Minutes
Installation
1. Remove Cover
Remove the Pumptec-Plus cover by removing the cover screw and sliding the cover up. Place
cover in a safe location.
2. Set the Timer Switch
Set the automatic timer switch to the desired reset time. This will determine the time after an
underload trip condition (dry well condition) has occurred until the Pumptec-Plus will try to restart
the motor.
FRONT COVER SCREW
7
8
9
0
1
3
2
4
5
6

6
PUMPTEC-PLUS Pump Protection System
3. Mount the Unit
Mount the Pumptec-Plus unit in a location convenient for wiring. Avoid direct sunlight, rain or snow.
4. Connect Power and Motor
Check to make sure the 230 Volt power has been disconnected. Connect Pumptec-Plus unit to the pump
motor and the 230 Volt AC line according to one of the two- or three-wire installation drawings below.
Pumptec-Plus may be wired into the circuit before or after the pressure switch, oat switch or other
system control switch.
MOUNTING SURFACE
SCREW
s WARNING
!
WARNING DISCONNECT POWER AT THE MAIN PANEL before installing, wiring
or servicing the Pumptec-Plus unit. Serious or fatal shock may occur if
power is not disconnected.
PRESSURE
SWITCH
OR OTHER
CONTROL
FUSED
DISCONNECT
OR
CIRCUIT
BREAKER
GND
GND
GND
L2
L2
M1
M2
L1 L1
GND
GND L2 L1
L2 L1
PUMP &
MOTOR
2-WIRE INSTALLATION

PUMPTEC-PLUS Pump Protection System
7
5. Replace Cover
Replace cover and secure with screw provided.
6. Apply Power
Once power is applied the Pumptec-Plus unit should trip, indicating an overload condition
(blinking yellow light) when the pump tries to run. This is normal and is a reminder that Pumptec-
Plus requires calibration.
NOTE: Some 1/2 hp motors will not trip in an overload condition upon the initial application of
power. The green light will blink instead. This is also a normal condition. Proceed to step 7.
FUSED
DISCONNECT
OR
CIRCUIT
BREAKER
GND
GND
GND
GND
L2
L2
L2
M1
M2
L1
L1
L1
GND L2 L1
RED
PUMP &
MOTOR
BLK
DELUXE
CONTROL
BOX
PRESSURE
SWITCH
OR OTHER
CONTROL
SW2 L2
L2
YEL
M2
PRESSURE
SWITCH
OR OTHER
CONTROL
FUSED
DISCONNECT
OR
CIRCUIT
BREAKER
GND
GND
GND
GND
L2
L2
M1
M2
M2
L1 L1
GND
GND M2 M1 M1
L2 L1
RED
PUMP &
MOTOR
BLK
YEL
CONTROL
BOX
L1 L2
3-WIRE INSTALLATION
3-WIRE INSTALLATION WITH DELUXE CONTROL BOX

8
PUMPTEC-PLUS Pump Protection System
7. Calibrate
Before the Pumptec-Plus unit is ready for use it MUST BE CALIBRATED. The calibration
procedure is quick and as simple as taking a snapshot.
Calibration may be performed as many times as desired by following steps A, B, and C below.
A. Press and hold in the reset button on the bottom of the Pumptec-Plus enclosure until the
green, yellow, and red lights blink alternately. This should take approximately 10 seconds.
You will hear the Pumptec-Plus contactor engage and the motor should start. Release the
reset button. Steps B and C must be completed within three minutes or the calibration
procedure will be aborted.
B. Verify that the pump system is running normally (i.e. the system is pumping water and the
motor current is normal). Try to achieve maximum water ow rate. Calibration on a fully
recovered well is recommended.
C. Briey press the reset switch again and then release it. You have just taken a snapshot
of the motor load. All indicator lights will go o. After 2 to 3 seconds, the green light will
start ashing, indicating the system is running normally and calibration is complete. Over/
underload trips will occur at 125% and 75% of the snapshot load.
Operation
Under normal operating conditions, Pumptec-Plus requires no special attention. The power line
voltage and motor power draw are continuously measured. If a fault condition is detected, an
indication is given by a light on the front panel and the motor is disconnected from the power line.
Pumptec-Plus measures the actual motor power (Watts), not motor amps or power factor. The
motor power draw at the moment of calibration is permanently memorized by Pumptec-Plus. If the
motor power draw diers from the memorized calibration power by more than ± 25%, Pumptec-
Plus will turn o the pump motor. It is very important to make sure the pump system is running
normally during the calibration process.
There are three indicator lights (A, B, and C) visible through the front cover. Each light is a dierent
color and each has a special meaning. Also, on the bottom of the unit enclosure is a reset button
(D). The purpose of each light and the operation of the reset button are described on page 5.
NOTE: Continuous memory holds calibration snapshot even if power is absent.
s WARNING
!
CAUTION Pumptec-Plus should only be calibrated by qualied service personnel.
Calibration on a faulty pump system will not provide protection.

PUMPTEC-PLUS Pump Protection System
9
Operation cont.
A. Green Light
The green light (A) indicates that the status of the pump system is normal.
A SOLID GREEN LIGHT indicates that Pumptec-Plus has power and the contactor to the motor
is closed but the motor is not running. This may happen when the pressure switch is wired in
down-line from Pumptec-Plus and the switch is open. Pumptec-Plus is waiting for the pressure
switch to close.
A FLASHING GREEN LIGHT indicates the pump motor is running normally and drawing the
correct amount of power.
B. Yellow Light
The yellow light (B) indicates that a load fault has occurred.
A SOLID YELLOW LIGHT indicates an underload fault occurred. The Pumptec-Plus automatic
restart timer will restart the motor in accordance with the position of the automatic restart timer
switch setting. The switch should be set at the time of installation (refer to step 2). If set in the
manual position, Pumptec-Plus must be reset manually by pushing the RESET BUTTON (D).
A FLASHING YELLOW LIGHT indicates an overload condition occurred. This means that the pump
system power draw was greater than the normal operating power (calibration) by more than 25%
for more than 2.5 seconds. Pumptec-Plus will not run the pump system again until the RESET
BUTTON (D) is pressed.
A. GREEN LIGHT
B.YELLOW LIGHT
C. RED LIGHT
D. RESET BUTTON

10
PUMPTEC-PLUS Pump Protection System
C. Red Light
The red light (C) indicates a line voltage fault occurred and Pumptec-Plus has turned o the pump motor.
A SOLID RED LIGHT indicates an under voltage condition (line< 207 VAC) existed for more than 2.5
seconds. Pumptec-Plus will automatically try to reset the motor within two minutes. The RESET BUTTON
(D) may also be pressed to clear this condition.
A FLASHING RED LIGHT indicates an over voltage condition (line> 253 VAC) has existed more than 2.5
seconds. Pumptec-Plus will automatically try to reset the motor within two minutes. The RESET BUTTON
(D) may also be pressed to clear this condition.
B & C. Red and Yellow Flashing Lights
The red light (C) indicates a line voltage fault occurred and Pumptec-Plus has turned o the pump motor.
A SOLID RED LIGHT indicates an under voltage condition (line< 207 VAC) existed for more than 2.5
seconds. Pumptec-Plus will automatically try to reset the motor within two minutes. The RESET BUTTON
(D) may also be pressed to clear this condition.
A FLASHING RED LIGHT indicates an over voltage condition (line> 253 VAC) has existed more than 2.5
seconds. Pumptec-Plus will automatically try to reset the motor within two minutes. The RESET BUTTON
(D) may also be pressed to clear this condition.
D. Reset Button
The reset button is used to restart the Pumptec-Plus from a tripped condition. Pressing the reset button
for less than ten seconds has no eect on the calibration. Simply press and release the button. The unit
will reset.
Pressing the reset button for more than 10 seconds will cause the unit to go into the calibration mode. A
rotating light sequence from green to yellow to red will begin. At this point, the contactor closes and the
motor will start to run. The unit will stay in the calibration mode for 3 minutes or until the reset button is
pressed again.
If after three minutes the reset button is not pressed, the unit will revert back to its normal running mode,
making no changes to the calibration.
Pressing the reset button before the three minute period expires will cause the unit to recalibrate to the
motor load present at the time the reset button is pressed the second time.
RESET BUTTON

PUMPTEC-PLUS Pump Protection System
11
Troubleshooting During Installation
Symptom Possible Cause Solution
Unit Appears Dead
(No Lights) No Power to Unit
Check wiring. Power supply voltage should be applied
to the L1 and L2 terminals of the Pumptec-Plus. In some
installations, the pressure switch or other control device
is wired to the input of the Pumptec-Plus. Make sure this
switch is closed.
Flashing Yellow Light
Unit Needs to Be Calibrated
Pumptec-Plus is calibrated at the factory so that it will
overload on most pump systems when the unit is rst
installed. This overload condition is a reminder that the
Pumptec-Plus unit requires calibration before use. See
step 7 of the installation instructions.
Miscalibrated
Pumptec-Plus should be calibrated on a fully recovered
well with maximum water ow. Flow restrictors are not
recommended.
Flashing Yellow Light
During Calibration Two-Wire Motor
Step C of the calibration instructions indicates that a
ashing green light condition will occur 2 to 3 seconds
after taking the snapshot of the motor load. On some two-
wire motors, the yellow light will ash instead of the green
light. Press and release the reset button. The green should
start ashing.
Flashing Red
and Yellow Lights
Power Interruptor
During the installation of Pumptec-Plus, power may be
switched on and o several times. If power is cycled more
than four times within a minute, Pumptec-Plus will trip on
rapid cycle. Press and release the reset button to restart
the unit.
Float Switch
A bobbing oat switch may cause the unit to detect
a rapid cycle condition on any motor or an overload
condition on two-wire motors. Try to reduce water
splashing or use a dierent switch.
Flashing Red Light
High Line Voltage The line voltage is over 253 Volts.
Check line voltage.*
Unloaded Generator
If you are using a generator, the line voltage may become
too high when the generator unloads. Pumptec-Plus will
not allow the motor to turn on again until the line voltage
returns to normal. Over voltage trips will also occur if the
line frequency drops too far below 60 Hz.
Solid Red Light
Low Line Voltage The line voltage is below 207 Volts. Check line voltage.
Loose Connections Check for loose connections which may cause
voltage drops.
Loaded Generator
If you are using a generator, the line voltage may become
too low when the generator loads. Pumptec-Plus will trip
on under voltage if the generator voltage drops below 207
Volts for more than 2.5 seconds. Under voltage trips will
also occur if the line frequency rises too far above 60 Hz.
*Report high or low line voltage to the power company.

12
PUMPTEC-PLUS Pump Protection System
Troubleshooting After Installation
Symptom Possible Cause Solution
Solid Yellow Light
Dry Well
Wait for the automatic restart timer to time out. During
the time out period the well should recover and ll with
water. If the automatic reset timer switch is set to the
manual position, then the reset button must be pressed to
reactivate the unit.
Blocked Intake Clean or replace pump intake screen.
Blocked Discharge Remove blockage in plumbing.
Check Valve Replace check valve.
Broken Shaft Replace broken parts.
Severe Rapid Cycling Machine gun rapid cycling can cause an underload
condition. See ashing red and yellow lights section below.
Worn Pump Replace worn pump parts and recalibrate.
Flashing Yellow Light
Stalled Motor Repair or replace pump motor. Pump may be sand or mud
locked.
Float Switch
A bobbing oat switch can cause two-wire motors to stall.
Arrange plumbing to avoid splashing water. Replace oat
switch.
Ground Fault Check insulation resistance on motor and control box
cable.
Solid Red Light
Low Line Voltage
Step C of the calibration instructions indicates that a
ashing green light condition will occur 2 to 3 seconds
after taking the Snapshot of the motor load. On some two-
wire motors, the yellow light will ash instead of the green
light. Press and release the reset button. The green should
start ashing.
Loose Connections
Check for excessive voltage drops in the system electrical
connections (i.e. circuit breakers, fuse clips, pressure
switch, and Pumptec-Plus L1 and L2 terminals). Repair
connections.
Flashing Red Light High Line Voltage
The line voltage is over 253 Volts. Check line voltage.*
The Pumptec-Plus will try to restart the motor every two
minutes until line voltage is normal.
Flashing Red And
Yellow Lights
Rapid Cycle
The most common cause for the rapid cycle condition is
a waterlogged tank. Check for a ruptured bladder in the
water tank. Check the air volume control or snifter valve for
proper operation. Check the setting on the pressure switch
and examine for defects.
Leaky Well System Replace damaged pipes or repair leaks.
Stuck Check Valve Failed valve will not hold pressure. Replace valve.
Float Switch
Press and release the reset button to restart the unit. A
bobbing oat switch may cause the unit to detect a rapid
cycle condition on any motor or an overload condition on
two-wire motors. Try to reduce water splashing or use a
dierent switch.
*Report high or low line voltage to the power company.

STANDARD LIMITED WARRANTY
Except as set forth in an Extended Warranty, for twelve (12) months from the date of installation, but in no event more than twenty-four
(24) months from the date of manufacture, Franklin hereby warrants to the purchaser (“Purchaser”) of Franklin’s products that, for the
applicable warranty period, the products purchased will (i) be free from defects in workmanship and material at the time of shipment, (ii)
perform consistently with samples previously supplied and (iii) conform to the specications published or agreed to in writing between the
purchaser and Franklin. This limited warranty extends only to products purchased directly from Franklin. If a product is purchased other
than from a distributor or directly from Franklin, such product must be installed by a Franklin Certied Installer for this limited warranty to
apply. This limited warranty is not assignable or transferable to any subsequent purchaser or user.
a. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, STATUTORY, EXPRESS, OR IMPLIED,
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. PURCHASER’S SOLE AND
EXCLUSIVE REMEDY
FOR FRANKLIN’S BREACH OF ITS OBLIGATIONS HEREUNDER, INCLUDING BREACH OF ANY EXPRESS OR IMPLIED WARRANTY OR
OTHERWISE, UNLESS PROVIDED ON THE FACE HEREOF OR IN A WRITTEN INSTRUMENT MADE PART OF THIS LIMITED WARRANTY,
SHALL BE FOR THE PURCHASE PRICE PAID TO FRANKLIN FOR THE NONCONFORMING OR DEFECTIVE PRODUCT OR FOR THE
REPAIR OR REPLACEMENT OF NONCONFORMING OR DEFECTIVE PRODUCT, AT FRANKLIN’S ELECTION. ANY FRANKLIN PRODUCT
WHICH FRANKLIN DETERMINES TO BE DEFECTIVE WITHIN THE WARRANTY PERIOD SHALL BE, AT FRANKLIN’S SOLE OPTION,
REPAIRED, REPLACED, OR A REFUND OF THE PURCHASE PRICE PAID. Some states do not allow limitations on how long an implied
warranty lasts, therefore, the limitations and exclusions relating to the products may not apply.
b. WITHOUT LIMITING THE GENERALITY OF THE EXCLUSIONS OF THIS LIMITED WARRANTY, FRANKLIN SHALL NOT BE LIABLE TO
THE PURCHASER OR ANY THIRD PARTY FOR ANY AND ALL (i) INCIDENTAL EXPENSES OR OTHER CHARGES, COSTS, EXPENSES
(INCLUDING COSTS OF INSPECTION, TESTING, STORAGE, OR TRANSPORTATION) OR (ii) DAMAGES, INCLUDING CONSEQUENTIAL,
SPECIAL DAMAGES, PUNITIVE OR INDIRECT DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS, LOST TIME AND
LOST BUSINESS OPPORTUNITIES, REGARDLESS OF WHETHER FRANKLIN IS OR IS SHOWN TO BE AT FAULT, AND REGARDLESS
OF WHETHER THERE IS OR THERE IS SHOWN TO HAVE BEEN A DEFECT IN MATERIALS OR WORKMANSHIP, NEGLIGENCE IN
MANUFACTURE OR DESIGN, OR A FAILURE TO WARN.
c. Franklin’s liability arising out of the sale or delivery of its products, or their use, whether based upon warranty contract, negligence, or
otherwise, shall not in any case exceed the cost of repair or replacement of the product and, upon expiration of any applicable warranty
period, any and all such liability shall terminate.
d. Without limiting the generality of the exclusions of this limited warranty, Franklin does not warrant the adequacy of any specications
provided directly or indirectly by a purchaser or that Franklin’s products will perform in accordance with such specications. This limited
warranty does not apply to any products that have been subject to misuse (including use in a manner inconsistent with the design of
the product), abuse, neglect, accident or improper installation or maintenance, or to products that have been altered or repaired by any
person or entity other than Franklin or its authorized representatives.
e. Unless otherwise specied in an Extended Warranty authorized by Franklin for a specic product or product line, this limited warranty
does not apply to performance caused by abrasive materials, corrosion due to aggressive conditions or improper voltage supply.
f. With respect to motors and pumps, the following conditions automatically void this limited warranty:
1. Mud or sand deposits which indicate that the motor has been submerged in mud or sand.
2. Physical damage as evidenced by bent shaft, broken or chipped castings, or broken or bent thrust parts.
3. Sand damage as indicated by abrasive wear of motor seals or splines.
4. Lightning damage (often referred to as high voltage surge damage).
5. Electrical failures due to the use of non-approved overload protection.
6. Unauthorized disassembly.

NOTES:

NOTES:

223424101
Rev. 8
05.16
9255 Coverdale Road, Fort Wayne, IN 46809
Tel: 260.824.2900 Fax: 260.824.2909
www.franklinwater.com
TOLL-FREE HELP FROM A FRIEND
Phone Franklin’s toll-free Technical SERVICE HOTLINE for answers to your installation questions.
When you call, a Franklin expert will offer assistance in trouble shooting your pump protection
system and provide immediate answers to your motor application questions.
Franklin Electric Technical SERVICE HOTLINE (800) 348-2420

PUMPTEC-PLUS
Sistema de protección
de bombas
Guía de instalación y
funcionamiento

s ¡ADVERTENCIA
!
s ¡ADVERTENCIA
!
Antes de empezar
Lea y siga las instrucciones de seguridad. Vea las placas de datos del producto para obtener
instrucciones de operación y especicaciones adicionales.
s ¡PRECAUCIÓN
!
s ¡PRECAUCIÓN
!
RIESGO DE DESCARGA ELÉCTRICA - Esta bomba viene equipada con un conductor a tierra y un
enchufe del tipo con conexión a tierra. Para reducir el riesgo de descarga eléctrica, asegúrese que se
conecte solo a un receptáculo del tipo con conexión a tierra que esté conectado apropiadamente a
tierra. Desconecte la alimentación antes de trabajar en el sistema Inline o cerca de él. No use el sistema
Inline en áreas donde se practique natación.
Este equipo debe ser instalado por personal técnicamente calicado. El incumplimiento de las
regulaciones locales y nacionales, así como de las recomendaciones de Franklin Electric, puede
resultar en descargas eléctricas, riesgo de incendio, desempeño insatisfactorio o fallas en el equipo.
Puede obtener la información para la instalación de los fabricantes o distribuidores de la bomba, o
llamando directamente a Franklin Electric a nuestra línea gratuita, 1-800-348-2420.
Los niños o personas con habilidades físicas, sensoriales o mentales reducidas o sin experiencia, no
deben usar este equipo a menos que estén supervisados o se les den instrucciones. Los niños no
deben usar el equipo y no deben jugar con el equipo o en sus cercanías.
Si el cable de alimentación está dañado, solo debe ser reemplazado por personal calicado.
• Mantenga limpia, bien iluminada y despejada el área de trabajo.
• Mantenga las etiquetas de seguridad limpias y en buenas condiciones.
• Use gafas de seguridad mientras está instalando o dando mantenimiento a la bomba.
• No opere la bomba en seco. Llene la bomba con agua antes de arrancarla o se dañará la bomba.
• Asegúrese de que toda la ALIMENTACIÓN ELÉCTRICA ESTÁ APAGADA antes de conectar
cualquier cable eléctrico. Cablear el Sistema de presurización Inline al voltaje correcto. Siga todas
las instrucciones de cableado de la bomba que se proporcionan en la sección "Cableado" de este
manual.
s
!
Este es un símbolo de alerta de seguridad. Cuando vea este símbolo en su bomba o en este
manual, busque alguna de las siguientes palabras de señalización y esté alerta a la posibilidad de
lesiones personales:
s
!
PELIGRO
s
!
AVISO
Este símbolo advierte sobre peligros que ocasionarán lesiones personales
graves, muerte o daños mayores a la propiedad si son ignorados.
Este símbolo advierte sobre peligros que pueden ocasionar
lesiones personales graves, muerte o daños mayores a la propiedad si son ignorados.
Este símbolo advierte sobre peligros que ocasionarán o podrán
ocasionar lesiones personales menores o daños mayores a la propiedad si son ignorados.
Indica instrucciones especiales que son importantes pero no están
relacionadas a los peligros. Lea cuidadosamente y cumpla todas las instrucciones de seguridad en
este manual y en la bomba.

Índice
Antes de empezar ...............................................................18
Características..................................................................20
Instalación .....................................................................21
Funcionamiento.................................................................24
Solución de problemas durante la instalación.........................................27
Solución de problemas después de la instalación .....................................28

20
Sistema de protección de bombas PUMPTEC-PLUS
Información de instalación
Características
Especicaciones técnicas
Potencia nominal 1/2 a 5 hp
Voltaje de funcionamiento 230 VCA*
Frecuencia de funcionamiento 60 Hz
Consumo de potencia 5 Watts
Rango de temperatura de funcionamiento -15 °F a 140 °F
Disparo de sobre/bajo voltaje ±10%
Disparo de sobre/baja carga ±25%**
Disparo de ciclo rápido 4 arranques/min
Tiempo de respuesta de disparo 2.5 s
Tiempo de reinicio automático 1 min a 4 horas 15 min
Reintento de sobre/bajo voltaje 2 min
Tiempo de abandonar calibración 3 min
Memoria de calibración 10 años
Clasicación del contactor 5 hp
s ¡ADVERTENCIA
!
ADVERTENCIA Para evitar una posible descarga eléctrica fatal, desconecte la
alimentación en el panel de principal de alimentación antes de
instalar, cablear, o dar servicio a Pumptec-Plus.
■Protección sobre/bajo carga ■Calibración instantánea
■Protección sobre/bajo voltaje ■Memoria de calibración continua
■Detección rápida de ciclo ■Funciona con todos los motores monofásicos
■Luces de indicación de falla ■Protección momentánea de picos
■ Luz indicadora de operación ■UL Listada (E104778)
■Contactor 5 hp ■Contador de tiempo de reinicio automático ajustable
■Bloques de terminales de uso pesado ■Línea gratuita de soporte al cliente (800 348 2420)
s ¡ADVERTENCIA
!
PRECAUCIÓN
Este producto no reemplaza a una caja de control del motor
o la necesidad de protección de sobrecarga del motor. La
instalación y la protección de sobrecarga del motor deberá
de estar de acuerdo con el artículo 430 del Código Eléctrico
Nacional o de acuerdo con las recomendaciones del fabricante.
NOTA: Esta unidad requiere calibración antes de su funcionamiento. La calibración se describe en
el paso 7 de las instrucciones de instalación.
* 220 Voltios, 50 Hz para modelo #5800060500
**Porcentaje de tiempo de carga de calibración INSTANTÁNEA
Table of contents
Languages:
Popular Protection Device manuals by other brands

EMX
EMX PhotoeyeVault instruction manual

Val-Matic
Val-Matic VentSafe Security Cage Operation, maintenance and installation manual

GE
GE MiCOM P40 Agile Technical manual

American Innovations
American Innovations SurgeProtect Kit Quick reference guide

ABB
ABB REF601 Applications manual

Intermatic
Intermatic AG48013 installation instructions