Free Cool ALWI-882 User manual

Alkaline Water Ionizer
Healthy life comes from nice
water! Water is Vital to Life!
ALWI-882

2
User Manual TABLE
OF CONTENTS
Glossary ............................................................ . 3
Warnings............................................................ . 4
Parts & Accessories ................................................... . 5
Installation ....................................................... . 6 - 7
Control Panel ....................................................... . 8
LCD Indicator ....................................................... . 9
Production Of Alkaline Water ......................................... . 10
Function Setting .................................................... . 11
Code Display Of Fillter Chip And Sensor ................................ . 12
Cleansing Electrodes & Modes & Uses ................................. . 13
Customizing Settings ................................................ . 15
Operations ........................................................ . 14
Replacements ..................................................... 16
Troubleshooting .................................................... . 17
Specifications ...................................................... . 18
WELCOME
Thank you for your purchase of the Alkaline ALWI-882 Water Ionizer.
The Alkaline ALWI-882 Water Ionizer is simple to install, easy to use, and the
automatic cleaning feature makes the machine virtually maintenance free.
This manual will guide you through the Installations, Controls, Uses and other
features of your Alkaline ALWI-882 Water Ionizer. Read through it carefully to
ensure you achieve optimum results.
We hope you enjoy the endless benefits of alkaline water provided by your
Alkaline ALWI-882 Water Ionizer for many years to come.
ALWI-882

RECORDS
Please record the name and phone number of your Dealer.
Name: ________________________________________________________________________________
Phone #:______________________________________________________________________________
Please record the serial number of your pureWater Alkaline ALWI-882.
Serial #: _______________________________________________________________________________
3
GLOSSARY
technology and chemistry involved in producing alkaline water can be more
terms associated with water ionization.
pH: The pH scale measures the level of acidity or alkalinity of a substance.
The pH scale ranges from 0 to 14.
Alkaline: Having a pH value above 7.
Acidic: Having a pH value below 7.
Neutral: Having a pH value of 7.
Electrolysis: A process in which an electric current is used to ionize water.
pureWater Water Ionizers use electrolysis to oxidize or reduce the water
molecules from your tap with several titanium plates that act as cathodes and
anodes. This process separates the alkaline water from its byproduct (acid
water) and vice versa.
ORP (Oxidation Reduction Potential): The measure of the tendency of a
substance to either gain or lose electrons. If the ORP is above zero, the water
output is acidic. If the ORP is below zero, the water output is alkaline.

4
WARNINGS
Consult a doctor before use, especially if you have a
weak liver, kidneys orare under treatment for any
ailments.
Never use aluminum or copper containers to store your ionized water.
A chemical reaction may occur.
Acidic water is for external purposes only. Do not ingest.
Never take medicine with alkaline water. Always use the neutral setting.
Never use hot water (over 40°C/104°F) with your Alkaline Water Ionizer.
It will damage your machine.
Ensure the waste water hose drains properly at all times.
Avoid direct sunlight and high temperatures around your Alkaline
Water Ionizer.
Always use the automatic cleaning feature to clean your Alkaline Water
Ionizer. Never use volatile solvents such as alcohol to clean your machine.
Never run water through your Alkaline Water Ionizer when it is not
powered as this may damage your machine.
Replace your
Unplug unit during extended times of idle.
Do not disassemble machine beyond what is shown in this manual.

5
PARTS & ACCESSORIES
Diverter x 1
Adapter B x 1 Adapter C x 1 Adapter D x 1
Wall Mount x 1
Adapter Key x 1
Connector x 1
Clamps x 2
Screws x 3
Rubber
Tightener x 1
Outlet Hose x 1
pH Test Kit x 1
Inlet/Drain Hose x 2
Adapter A x 1
ALWI-882

6
INSTALLATION
1. Determine the faucet’s threading, choose approrpriate adapter and install as shown.
External Thread
Threadless (13-24mm)
1
1Tighten the adapter into place using
the locking key with the gasket and
nut above it.
Push the diverter and tightener over
the faucet and secure the clamp.
Twist the nut in clockwise direction.
Nut
Rubber Tightener Clamp
Tighten the nut and reserve 3-4mm
space between nut and thread of
the diverter. Place the clamp
around the tightener.
Nut
Clamp
3~4mm
2
2
Attach diverter to the adapter and
fasten the nut around it.
Nut
Waterproof Gasket
Adapter
Diverter
Internal Thread or
Adapter
(C)
Adapter
(D)
Nut
Waterproof Gasket
Adapter
Adapter
(A)
Adapter
(B)
or
Note: These directions apply to both External and Internal Threads.
Nut
Nut
ALWI-882

7
Push the connector into the diverter.
Cut the supplied hose in half. Connect and
secure them over the inlet and outlet with
the hose fasteners.
Place clamps over the hose ends leaving open space to fit
over the water supplies. Connect Hose A to Tap Water In (A)
and Hose B to Drain Water Out (B) on the base of your unit.
Twist into position in a counter-clockwise direction.
Tap Water In (A)
Power Cord
Drain Water Out (B)
Hose fasteners
Hose A
Hose B
Outlet (A)
Inlet (B)
1
1
Screw the Outlet Hose into position at the top of the unit.
Slide and secure the hoses over the Tap Water In
and Drain Water Out with the clamps.
3 4
2
2
INSTALLATION CONT.
2.Install the Connector.
Once installationis complete, plugyour unit in and refer to OPERATIONS (Page10) of this
manual to learn how to run your newly installed AlkalineALWI-882.
3.Install Hoses.
4.Power
ALWI-882

13
CLEANSING ELECTRODES
MODES & USES
Each level of Acidic, Neutral, and Alkaline water has a general use based on its
pH level. Use our guide below to know what water mode you should use for a
certain situation.
Consult a doctor before use, especially if you have a weak liver, kidneys or are under treatment
for any ailments.
ALWI-882

14
OPERATIONS
How it works
Japanese made titanium plates where the water molecules are separated by an electric
charge. This is a process called electrolysis.
Upon selecting the desired level of alkalinity on the front of the unit, the alkaline water is
First, press the button of your desired (e.g. “Alkaline 1”). [When just beginning an alkaline
gradually progress to Alkaline 3].
The display will light up. Let the water run on the selected level for about 5-7 seconds
How to Use
Once you have completed installation of your Alkaline ALWI-882 Water Ionizer and it is
plugged into a power outlet you can begin to use your machine.
The water first travels from your tap through a Cardon filter where impurities like chlorine
are removed from your tap water.
ALWI-882

15
CUSTOMIZING SETTINGS
Electrolysis Intensity
Slower Flow = Higher pH Level.
Note: The conductivity of the water (measured in TDS) can affect the pH level.
Before setting Electrolysis Intensity, turn off tap (unit power should still be on).
Select the level you wish to adjust (i.e. “Alkaline 4, Alkaline 3, etc.) and hold the button for
5 seconds until the LED Display lights up.
Press the “RESET” and “CLEAN” buttons to adjust the electrolysis intensity.
Once the desired electrolysis intensity level is reached, press the same level button (i.e.
“Alkaline 4, Alkaline 3, etc.) once more to set the electrolysis intensity.
Using your pH Test Kit
Remove the test liquid from the container and place 2 small drops inside. Select your
card to check the accuracy of your setting.
Note: For better accuracy, allow 5-7 seconds of running water for your Ionizer to change its pH to the
desired setting before testing the water.
Filter Longevity
Before setting Filter longevity, turn off tap (unit power should still be on).
Press the “NEUTRAL” button and hold for 5 seconds until the LED Display lights up. Press the “NEUTRAL” button once
more to switch fromElectrolysis Intensity setting to Filter Longevity setting.
The Filter Longevity icon is now shown on the LED Display.
Press the “NEUTRAL” button again after completion of setting to resume normal operation.
The water first travels from your tap through a Carbon filter where, the Electrolysis Intensity
Setting is designed to help you calibrate each level of pH on your Alkaline ALWI-882 Water
Ionizer. Water quality can affect the output level of pH from your machine.
Use the pH test kit provided to ensure accurate pH output for each level. Use the Electrolysis
Intensity Setting to adjust if necessary.
ALWI-882

16
REPLACEMENTS
Replacing the Filter
In order to experience optimum performance and full functionality from your Alkaline
1. Open the back cover.
2. Unwind the filter counterclockwise and remove over a sink in case excess
water dripsout.
3. Set the new filter in the socket and turn clockwise to secure in place.
4. Replace the cover.
5. Plug in Power Cord.
6. Press and hold the “RESET” button for 5 seconds.
Reset is complete when the Filter Longevity Display (Page 8) has reset and the “RESET” light is off.
1 2 3 4
2
1
2
1
ALWI-882

17
TROUBLESHOOTING
LED backlight isn’t working.
Check to make sure the unit is plugged in. Water pressure may be too low. Check to see if
retailer for repair.
could be obstructing the hose. Contact your retailer for cleaning or repair.
Alkaline water is cloudy.
Alkaline water appears cloudy in general due to the air bubbles generated during
electrolysis. The water is safe to drink and will clear as it rests.
There are dark brown particles in the water.
These particles are ferrous (iron containing) content and are harmless to your health.
Perform cleaning to clear any particles out of the machine.
White substance in your Alkaline water container.
This is a calcium buildup caused by the calcium ions and carbonic acids in the air. It is
harmless to ingest. Clean your container using vinegar on any affected surfaces.
secured in its socket. If leak persists contact your retailer for repair or replacement.
Water from the unit has an odor.
ALWI-882

18
Filter The Iontech utilizes NSF Certified filter, ACF-3,
manufactured by Pentair.
The ACF-3 Carbon is tested and Certified by
NSF International against NSF/ANSI standard
42, for material requirements only.
5.0 liters/min and up to 6,000L Lifespan.
Residual salt and odor removal.
SPECIFICATIONS
Dimensions (mm) H310 x W220 x D125
Weight 4.5kg
Voltage/Frequency 110V/60Hz 220V/50Hz
Electrolysis 3/5 Titanium-Platinum Plates and Ceramic
Membrane Continuous Electrolysis (built-
gallon/min (2L/min)
Power Consumption 180W MAX / 230W MAX
Maximum Temperature 104°F (40°C)
Output .26 - .79 gallons/min (1-3L/min)
ORP -650 mV (MAX) / -850 mV (MAX)
ALWI-882

Multitasking Corporation Ltd
Multitasking Inductor Electronic LTD
647, Yeogsam-Dong, Gangnam-gu, Seoul, Korea,
289 Dagang san Road Beilun District Ningbo Zhejiang ,China. Email:
Table of contents
Popular Air Ionizer manuals by other brands

ESD SYSTEMS
ESD SYSTEMS Eliminator Plus Installation, operation and maintenance

ESD SYSTEMS
ESD SYSTEMS Auto-Ion Operation installation and maintenance

GPS
GPS iRIB-18 Start-Up Checklist

Hakko Electronics
Hakko Electronics FE-500 instruction manual

Bionizer
Bionizer Spa Star Instruction book

AirPlus