frieling MILKchiller 0501 User manual

OWNER’S MANUAL
Model No. 0501 and 0601
MILKchiller
by
™

2
Important Safeguards
When using an electrical appliance, basic safety precautions should
always be followed to reduce the risk of fire, electrical shock and injury to
persons, including the following:
1. Read all instructions before using appliance.
2. Close supervision is necessary when any appliance is used near
children.
3. This appliance is not for use by children.
4. The cord to this appliance should be plugged into a 120V AC
electrical outlet only.
5. Do not operate any appliance with a damaged cord or plug or after
the appliance malfunctions, or has been dropped or damaged in
any manner. Contact Consumer Service for return authorization,
examination, repair or adjustment.
6. If this appliance malfunctions during use, immediately unplug the
cord from the outlet. Do not attempt to repair the malfunctioning
appliance.
7. Unplug unit when not in use and before cleaning.
8. Do not let the power supply hang over edge of table or counter.
9. Use caution when transporting MILKchiller™.
10. Do not place on or near a hot gas or electric burner, or in a heated
oven.
11. The use of accessory attachments is not recommended by the
manufacturer as it may cause injuries.
12. Use MILKchiller™ unit only with the provided base and on a flat
surface.
SAVE THESE INSTRUCTIONS

3
Important Safeguards (cont.)
CAUTION: Do not block the cooling fan in the back of the unit nor the
exhaust ports on the side the MILKchiller™. Allow ample space for air
circulation.
CAUTION: Do not immerse the power-supply, cord, or appliance in
water or any other liquid.
CAUTION: Do not use metal scouring pads to clean the appliance.
Pieces of the pad may break off and touch electrical parts.
CAUTION: Do not pour water or any liquid into the chilling chamber
of the MILKchiller™.
CAUTION: The room temperature for normal operation of the
MILKchiller™ is below 30°C, 86°F. We cannot guarantee proper
functioning of the MILKchiller™ in a room or environment above these
temperatures.
Polarized Plug
This appliance has a polarized plug (one blade is wider that the other).
As a safety feature to reduce the risk of electrical shock, this plug is
intended to fit in a polarized outlet only one way. If the plug does not
fit fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician. Do not attempt to modify the plug in any way.
Power Cord Instructions
A long power cord is provided so that the MILKchiller™ can be located
away from the power outlet. Care must be taken to ensure the cord does
not become entangled or located where tripping can occur.

4
Parts List Item No.
1. MILKchiller™ unit 0501 or 0601
2. Power Supply and Plug 0713
3. Base with Drip Tray Cup 0721
4. Drip Tray Insert 0710
5. Drip Tray Metal platform 0711
6. Disposable Straw for Plastic Cartons
and MILKchiller™ Refillable Container
0702
7. Disposable Straw for Paper Cartons 0701
8. MILKchiller™ Refillable Container Lid
(available separately, not included)
0723
9. MILKchiller™ Refillable Container
(available separately, not included)
0724
10. Air Filter 0705
11. Wire tie 0725
12. Pipette
1
2
3
4
5
6
7
8
9
10
11
12
MILKchiller™
Parts and Accessories
Please see pages 20 - 23 for complete parts/accessory order details.

5
Congratulations!
MILKchiller™ is the unique solution for your beverage station because
it…
• Maintains dairy products at a safe temperature of 41ºF or below.
• Features an LCD displays 8 types of dairy products: whole;
cream; ½ & ½; 1%; 2%; skim; fat-free; and soy; in 5 different
languages: English, French, German, Italian and Spanish.
• Accommodates standard ½ gallon dairy cartons or plastic
containers.
• Will also accommodate the dishwasher safe, MILKchiller™
Refillable Container.
• Dispenses dairy products with a simple press of a button.
• Eliminates mess and waste.
• Is easy to operate and to replace the dairy container.
Before Using for the First Time
1. Carefully unpack the MILKchiller™ from the box.
2. Read all of the instructions included in this manual.
3. Remove all the packing material including the white wrappers
protecting the stainless steel components.
4. Make sure the MILKchiller™ is unplugged and the power switch
is in the OFF position.
5. Wipe exterior surfaces with a damp cloth. Dry thoroughly with a
soft cloth. DO NOT use harsh or abrasive cleansers as these can
damage the exterior surfaces.
CAUTION: Do not immerse the power supply, the cord, or the
appliance in water or any other liquid.
6. If purchased, remove the MILKchiller™ Refillable Container
and lid. Wash them in warm, soapy water or in the upper rack of
the dishwasher.
7. Thoroughly dry the MILKchiller™ Refillable Container and lid.

6
The MILKchiller™ is now ready for use.
Plug the power supply connector into the Power Input on the
MILKchiller™ control panel. Connect the power supply to the power
cord and plug it into the wall outlet. Set the Power Switch to ON.
Upon start up, the LCD will alternately flash COOLING, LOW and
WHOLE until the MILKchiller™ has reached the safety standard
temperature. (The “LOW” message will disappear when the full carton
or container is inserted into the chilling chamber.)
When it has reached the safety standard temperature, the LCD will
display the default setting “WHOLE”.
For more information on the setting display, please see the section
DISPLAY SETTINGS and CONTROL PANEL FUNCTIONS.
Power Supply
Connector
Power Inlet
Power Switch

7
Fine Tuning the Low Level Indicator
1. Locate the calibration screw on
the underside of the MilkChiller™
just behind the drip tray.
2. Fill a container 1/4 full or more with liquid.
This is the approximate amount of dairy product
remaining in the container when the LOW indicator
flashes on the display.
Place container in the MilkChiller™ and close the lid.
3. Place the MilkChiller™ on a flat
surface that will provide access to the
calibration screw. We suggest using an
inside corner of a counter, or pushing two
tables together leaving 2 inches between
them for access to the screw.
4. Using a flathead screwdriver, SLOWLY
adjust screw on the bottom in a clockwise
manner just until the LOW indicator is
flashing.
5. Further adjust the screw ½ turn to
complete the calibration.
The Low Level Indicator has been calibrated
to trigger at approximately 18 ounces, 1/4 of
a carton. This is the minimum amount of
liquid remaining in the carton when the LOW
indicator flashes. The Low Level Indication
can be adjusted to trigger for more liquid
remaining in the carton if desired.
If, after time, the LOW indicator does not
flash at the desired liquid level, readjust the
calibration screw as outlined above.

8
How To Insert Disposable Straw into
MILKchiller™ Refillable Container:
1. Unscrew lid from container.
2. Fill container with dairy product up to the
MAX Fill Line.
3. Screw on lid.
4. Insert Disposable Straw for Plastic into
opening in lid orienting the holes front to back
as shown.
5. Press straw cap into opening for a tight fit.
How To Insert Disposable Straw into
Paper Half Gallon Container:
1. Unscrew the cap and remove the inner seal on
the pour spout.
2. Insert the Disposable Straw for Paper into the
pour spout.
3. Ensure the straw is pointing forward and
orient the holes side by side as shown.
4. Press straw cap into opening for a tight fit.
How To Insert Disposable Straw into
Plastic Half Gallon Container:
1. Remove the cap on the pour spout.
2. Pour out roughly 2 oz. of milk from plastic half
gallon container.*
3. Insert the Disposable Straw for Plastic into the
pour spout and orient the holes front to back as
shown.
4. Press straw cap into opening for a tight fit.
* Some dairy factories fill plastic containers to
the top. This overfilling can cause some liquid to
spill when the container is inserted into the chilling
chamber. Therefore we recommend pouring out
some liquid before inserting the straw.
If the Disposable Straw cap does not fit into the pour spout on the
container, please use the MILKchiller™ Refillable Container.
The MILKchiller™ can now be loaded with a ½ gallon paper carton or the
MILKchiller™ Refillable Container filled with dairy product.
It is required to refrigerate all dairy products prior to use in the MILKchiller™.
If using shelf stable milk, the MILKchiller™ will not operate until the milk has
cooled to the safe temperature specification.

9
Load Container into MILKchiller™
To load the container into the MILKchiller™, regardless of the type of
container:
1. Lift the lid by pulling upward on the dispensing spout.
2. Orient the container so that the Disposable Straw is pointing to the front
of the machine.
3. Reposition the Air Hose with Air Hose Fitting to clear the path for the
container.
4. Insert the container into the chilling chamber until it sits on the bottom
surface. Align the Disposable Straw to fit tightly in the forward channel.
PLEASE NOTE: If the liquid escapes from the straw while inserting the
container, please lift the container out of the chamber, remove the straw
and pour some liquid out. The container was overfilled.
5. Insert the Air Hose Fitting into the second hole in the Disposable Straw
by looping around the straw counter clockwise. See drawings for
orientation. Press down for a tight fit.
6. Lower the lid to close the machine.
MILKchiller™ Refillable Container
Air Hose

10
Please remember to pour out 2 oz. of
liquid prior to loading plastic ½ gallon
carton into MILKchiller™.
Plastic Half Gallon container
Paper Half Gallon container
Air Hose
Air Hose

11
Control Panel Functions
The MILKchiller™ is programmed for use worldwide. The LCD
displays the dairy contents in 5 different languages.
The MILKchiller™ must be initialized before use by first setting the
language, and then setting contents.
Language Button – Button 2
Sets the language in which the dairy
contents are displayed. Pressing
the button cycles through the 5
language options:
ENGLISH, GERMAN, ITALIAN,
FRENCH, SPANISH.
To set the LANGUAGE: Stop pressing the Language Button when the
desired language is displayed. After a few seconds the default content of
WHOLE (or the equivalent in another language) will be displayed.
Reset
Contents
Language
Temperature
Display
Power Input
Power Switch
0
ENGLISH

12
Contents Button – Button 1
Sets the display to show the
contents of the container in the
MILKchiller™.
Pressing the button cycles through
the 8 types of dairy product:
WHOLE, ½ & ½, 1%, 2%, SKIM,
FAT FREE, SOY, CREAM.
To set the CONTENTS: Stop pressing the Contents Button when the
desired dairy type is displayed.
To Change the CONTENTS display: press the CONTENTS button to
cycle through the dairy types, stopping on the desired type to display.
Reset Button – Button 3, internal button, for operator use only.
By pressing the internal button with a small sharp object such as a
paper clip, the display is reset to the manufacturer’s default settings.
The default settings are ENGLISH and WHOLE. After resetting the
MILKchiller™, the LANGUAGE button and CONTENTS button must be
set to the desired display settings.
Temperature Display Button – for operator use only.
Pressing and holding the
Temperature Display button shows
the temperature of the dairy product
on the LCD in ºF and ºC. This
is for inspection purposes only.
Releasing the button returns the
display to the last setting.
Power Input – connector of the power supply, provided with each unit.
Power Switch – ON / OFF power switch. When the MILKchiller™ is
powered off and on, the display retains its last setting.
41ºF, 5ºC
CREAM

13
If SERVICE is flashing on the
LCD, the MILKchiller™ should
be returned for service.
This indicates the machine is not
cooling to the safe temperature
specification, and the dairy
product may not be safe to ingest.
When the level of the liquid
becomes low, the machine
notifies the operator by flashing
LOW.
The operator is alerted that the
dairy product needs to be refilled
soon.
When the unit is first starting
up the LCD flashes COOLING
until it has reached cooling
temperature.
If after 2 hours the
MILKchiller™ does not reach
cooling temperature, SERVICE
is flashed on the LCD, and the
pump will not operate.
Display Settings
The LCD on the front of the machine has many uses.
1. It shows the contents of the MILKchiller™ in daily use.
2. It displays the temperature of the liquid when Temperature
Button is pressed.
3. It communicates the status of the machine:
COOLING
SERVICE
LOW

14
Removing Empty Carton or Container
The MILKchiller™ notifies the operator that the content of the container
is getting low by flashing LOW on the display. To remove an empty
carton or container:
1. Lift the lid by pulling upward on the dispensing spout.
2. Disengage the Air Hose Fitting and Air Hose from the Disposable Straw
Cap.
3. Lift the empty container from the chilling chamber.
4. Dispose of empty container and Disposable Straw according to local
recycling laws and policies.
5. Clean the Chilling Cavity as outlined in the Care and Cleaning Section.
To refill the MILKchiller™ with a full carton or container, follow the
instructions found in section INSERT DISPOSABLE STRAW and
LOAD CONTAINER.
Before Leaving for the Day
1. Remove the container from chilling chamber and place in refrigerator for
overnight storage.
2. Turn OFF the MILKchiller™ to save energy.
Dispensing Dairy Product
The push button on the left side of the MILKchiller™ causes the dairy
product to be delivered through the dispensing spout. Dairy product
will be delivered for as long as the button is depressed up to 60 seconds.
There might be a slight delay between pushing the button and the
delivery of the dairy product.
Dispensing
Spout
Push Button to
Dispense Dairy
Product
PLEASE NOTE: The force of depressing the Push Button may cause the LOW
level indicator to flash. When the button is released, the LOW level indicator
will disappear.

15
To move location of base:
1. Back out screws part way to unlock base.
2. Move base forward to clear screw head.
3. Lift base off counter top.
1. Place base at desired location
on counter top.
2. Mark screw locations at the
bottom of the keyhole.
3. Remove base. Drill pilot holes
into countertop.
4. Replace base, and drill screws
into countertop to lock down
base.
Fasten Base to Countertop
The base is equipped with two keyholes for locking
it to the countertop, if desired.

16
Lock MILKchiller™ to Base
Place the MILKchiller™ on the base, inserting the feet into the
corresponding holes in the base.
At the back of the unit and base, there are locking tabs that can be used
to secure the MILKchiller™ to the base. Insert the provided wire tie
through both openings in the locking tabs and fasten. A small pad lock
can be looped in the locking tabs for added security.
PLEASE NOTE: do not over tighten the wire tie, as some movement is
required.

17
The Drip Tray is an integral
part of the base.
The Drip Tray insert is
provided so that when
the base is fastened to the
countertop, the insert can be
removed and emptied.
There is a fitting located on the
underside of the Drip Tray to
which a hose can be attached.
A Drain Hose can be routed
beneath the counter to a bin to
collect larger amounts of excess
liquid.
In this case, the Drip Tray Insert
is removed and not used.
Drip Tray Features
Hole in Drip Tray
Drip Tray Insert

18
To Replace the Air Filter:
1. Gently pull upwards on the tab extending above the plastic grill.
2. Lift filter out of grill and dispose.
3. Load replacement filter by sliding it along the back wall and into the
slot between the grill and the housing.
4. It may be necessary to loosen the 4 screws in the grill to free or load
the filter. Be sure to tighten the screws after loading the Air Filter.
Replace the Air Filter
The Air Filter located at the lower back of the MILKchiller™ filters
the air being used to dispense the dairy product. It is recommended
to change the filter at least once every three months, more often if the
environment requires and the Air Filter turns dark in color.
Air Filter
Screws

19
Care and Cleaning
CAUTION: Do not immerse the power supply, cord, or appliance in
water or any other liquid.
CAUTION: Do not use metal scouring pads to clean the appliance.
Pieces of the pad may break off and touch electrical parts.
CAUTION: Do not pour water or any liquid into the chilling chamber
of the MILKchiller™.
1. Unplug the MILKchiller™, open the lid and allow all parts to reach
room temperature before cleaning.
2. Clean the outside of the MILKchiller™ with a clean damp sponge.
Do not use an abrasive cleaner, as it may damage the exterior finish.
3. Clean the inside of the MILKchiller™ with a clean sponge and
a small amount of mild dish detergent. Wipe dry with a paper or
cloth towel.
4. The MILKchiller™ Refillable Container and Lid can be washed
with warm, soapy water or placed on the top shelf of the
dishwasher. Dry thoroughly before next use.
5. The base and drip tray insert can be washed with warm, soapy water
or placed in the dishwasher.
6. The Drip Tray Metal Platform can be washed with warm, soapy
water or placed in the dishwasher.
7. If using the drip tray and hose, run hot soapy water through the drip
tray and hose into the large bin to clean.
8. Do not clean the Disposable Straws. They are designed to be
thrown away with each carton, and re-use may risk contamination.
9. The pipette is provided to clean the Disposable Straws in an
emergency situation where there are no clean Disposable Straws.
Starting with a new straw each time the dairy product is replaced
eliminates contamination risks. The exchange is easy, fast, safe, and
compliant with health department regulations. Please recycle used
straws.
10. Let all parts dry thoroughly prior to plugging in the MILKchiller™
and using.
11. Regularly clean fan and fan grill with a damp cloth to remove dust.

20
Troubleshooting
The MILKchiller™ is plugged
in, however, the display is
blank.
Make sure the cord is securely plugged into
the power supply and the Power Switch is in
the ON position.
The MILKchiller™ is plugged
in and the Switch is in the ON
position and the display is
blank.
Call the MILKchiller™ HOTLINE for
service.
If the MILKchiller™ is turned
off will I lose my settings?
No, the MILKchiller™ will have the same
settings at the next start-up.
The display continues to
flash “COOLING” 2 hours
after powering ON the
MILKchiller™.
Remove and discard the contents of the
MILKchiller™.
Turn the MILKchiller™ OFF, wait 3 seconds
then turn ON.
Use a new container of dairy product that has
been refrigerated at the proper temperature.
If problem persists, call the MILKchiller™
HOTLINE for service.
There was a power failure for 2
or more hours, is the milk safe?
It is recommended not to serve dairy products
that have not been cooled for over 2 hours.
If there is a power failure during business
hours, remove the container from the chilling
chamber and place in refrigerator. Turn the
MILKchiller™ to OFF for the duration of the
power failure.
Please remember to remove the container
from the chilling chamber and store it
overnight in the refrigerator. This will avoid
the dairy product spoiling overnight in the
event of an extended power outage.
Power ON the MILKchiller™ ™ after the
power has been restored.
When loading a ½ gallon
carton, liquid escapes from the
Disposable Straw.
Some ½ gallon containers are filled to the
top, causing milk to escape.
Pour out 2 oz. of liquid prior to inserting the
Disposable Straw.
When the push button is
pressed, the LOW indicator
flashes, even with a full carton
of dairy product installed.
This is normal, the force of pressing the push
button triggers the LOW indicator. It will
disappear when the push button is released,
unless the liquid level is actually LOW.
This manual suits for next models
1
Table of contents
Other frieling Kitchen Appliance manuals